• Title/Summary/Keyword: Transformer Oil-paper

Search Result 235, Processing Time 0.02 seconds

The Effect of Additive on the Electric conductivity of Insulating Oil (절연유의 전기전도에 미치는 첨가제의 영향)

  • 정광현;김영봉;김용운;임헌찬;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.158-161
    • /
    • 1996
  • The static charges are generated by streaming electrification phenomena in insulating oil flowing by force for the purpose of cooling at the internal of Ultra-high power transformer. In this thesis, their elimination method was studied. In this paper the effect of Additive on the electric conductivity of Insulating oil is studied. The variation of electric conductivity disappear when Additive is molten in insulating oil BTA(Benzotriazole) appear more variation of electric conductivity than that of SP-S10(Sorbitan mono-stearate). But the variation is not enough to decrease streaming electrification of insulating oil($\sigma$>10$\^$-12/[S/cm]).

  • PDF

Characteristics of Static Electrification on Insulation Oil Aging (변압기 절연유의 열화에 따른 대전특성)

  • Kweon, Dong-Jin;Kim, Han-Sang;Chong, Yong-Ki;Kim, Kyoung-Wha;Kim, Du-Seok;Kwak, Hee-Ro;Park, Tong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1615-1618
    • /
    • 1994
  • This paper studied the streaming electrification of the U.H.V. transformer with the spinning cylinder system, and compared and analyzed it with the conventional forced flowing system which uses a pump or gas for oil flowing. Also, accumulated surface voltage in its electrified material was measured with the electrostatic voltmeter, and the effect of insulation oil aging was measured. As results, in spinning cylinder system, characteristics of the streaming electrification to its rotational speed and oil temperature are same tendency as those of tile forced flowing system and it showed the spinning cylinder system is useful to study the streaming electrification. And, aging of insulation oil increases the electricity of streaming electrification at initial stage of aging.

  • PDF

Characterisrics of Dissolved Gas Distribution in Oil with Thermal and Electrical Degradation in Oil Imersed Paper Insulation (유침 절연에서 전기적 및 열적 열화에 따른 유중가스분포특성)

  • Sun, Jong-Ho;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.136-144
    • /
    • 2004
  • Dissolved gas in oil analysis has been used for fault diagnosis of oil immersed insulation. In this paper to improve the reliability in deciding the degradation causes of the oil immersed insulation, we carried out electrical and thermal degradations for the insulations, and analyzed the characteristics of dissolved gases distribution on each situation. As a result more reliable faults discrimination is possible if we use the interrelation of factors like key gases and gas compositions of hydrocarbon gases and ratios of CO/$CO_2$.

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

Overload Criteria of Distribution Transformers Considering the Electric Consumption Patterns of Customers (수용가 전력 소비 패턴을 고려한 배전용 변압기 과부하 판정기준)

  • 윤상윤;김재철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.9
    • /
    • pp.513-520
    • /
    • 2004
  • In the paper, we summarize the result of the experimental research for the overload criteria of domestic distribution transformers considering the electric consumption patterns of customers. For the basic characteristic data of distribution transformer overload, the actual experiments are accomplished. The field data of loads are surveyed from sample transformers for analyzing the consumption pattern of customer load. The load data acquisition devices are equipped, and the algorithm of load pattern classification is applied. In addition to this efforts, various load pattern data. in past are gathered. Then the representative load pattern of each customer type in domestic is extracted. The final results of overload criterions are presented as tabular form through the results of experiments and survey are combined. The field test of the experiment results is peformed using the special manufactured transformers, which can measure both the load and top-oil temperature of transformer. Through this, we verify that the results of field test are similar to the laboratory one and the Proposed overload criteria can be effectively applied to the real system.

Electrical Properties of Transformer Oils due to Electron Beam Irradiation (전자선 조사에 따른 변압기유의 전기적 특성)

  • 이용우;조돈찬;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.756-762
    • /
    • 1997
  • In this paper the change of electrical properties of transformer oil due to electron beam irradiation is investigated. The specimens are produced with a some different dose of 0.5[Mrad], 1[Mrad] and 2[Mard] except for original specimen. The physical properties of each specimen is analyzed by using the FT-IR spectrum. So it is confirmed that carbonyl groups are increased according to the increase of electron beam dose and also that the nitric compounds are disappeared. The magnitude of dielectric dissipation factor appears maximum value by the contribution of dipoles and ions in the low temperature low voltage region and it is stable due to the saturation of carriers in the high temperature high voltage region in the electric conduction characteristics. Volume resistivity is also measured one of original specimen is larger than irradiated specimen.

  • PDF

A Fault Diagnostic Expert System for Silicone Oil-filled Transformer Using Dissolved Gas Analysis (유중가스분석법을 이용한 실리콘 유입변압기 고장진단 전문가 시스템)

  • Moon, Jong-Fil;Kim, Jae-Chul;Choi, Joon-Ho;Jun, Young-Jae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.374-376
    • /
    • 2001
  • In this paper, we developed the fault diagnostic expert system of silicone-immersed transformer using dissolved gas analysis. The knowledge base module consists of the knowledge using the rule: if Then . The inference engine uses the fuzzy rule for the management of uncertainty of the boundary and rule and derivate the Belief and Plausibility of the normality and fault using Dempster-Shafer theory. The expert system is connected to the database and it can manages the history of gas-data of the transformer.

  • PDF

Dielectric Properties of Ultra-High Voltage Transformer Oils due to Streaming Electrification Suppressant (유동대전 억제제에 의한 초고압 변압기유의 유전 특성)

  • 이태훈;신종열;조경순;이용우;이수원;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.203-206
    • /
    • 1998
  • In this paper, specimens stirred with the several kinds of benzotriazole(following as BTA) addition which is very effective to decrease the streaming electrification, are tested to investigate the change of properties for insulating fluid using in ultra-high voltage transformer, and it will give a guideline to find out a proper quantity of BTA addition for the most effective suppression against the streaming electrification. In GC, we could not find out the change of the physical properties in an insulating fluid by BTA. In a flowing transformer oil, the characteristics on dielectric of specimen contained BTA 10[ppm] are superior to the others.

  • PDF

Development of Diagnosis Device for Pole and Pad Transformer using Wireless Data Communication (무선 데이터 통신을 이용한 주상 및 지상 변압기 진단 장치 개발)

  • 윤용한;민경래;최도혁;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.85-92
    • /
    • 2000
  • This paper has developed the system that can monitor the distribution transformers(pole and pad) using simplified deterioration detecting sensor in oil and wireless data communication. This system is made up by deterioration detecting sensor, oil level measuring system, deterioration measuring system and communication unit. To prove the usefulness of the system, the paper compared and analyzed the system with the existed system, and after studying the correlation of the both, the result proved goodness of the new system. The proposed monitoring system, when it is used on the pole and pad transformer, would make the reliable diagnoses possible with less rate.

  • PDF

Development of Phase Sensitive Detector for Diagnosis of Distribution Transformers (배전용 변압기의 진단을 위한 위상 검출 장치의 개발)

  • Kim, Young-Chun;Choi, Do-Hyuk;Yoon, Yong-Han;Min, Kyeoung-Rae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.547-549
    • /
    • 2000
  • This paper develops phase sensitive detector for diagnosis of distribution transformers. And to detect the $tan{\delta}$ more effectively, this paper used phase sensitive detector. The sensor in oil which could be placed inside of the distribution transformer can measures the $tan{\delta}$ in oil. This could be the important factor and information, and it could be used for the basic information for a precise diagnosis. Establishment of the proposed system helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF