• 제목/요약/키워드: Transformer Noise

검색결과 203건 처리시간 0.029초

Sagnac형 광섬유 배열센서를 이용한 유증 음답 탐지 연구 (Investigation of the Acoustic Detection in Transformer Oil Using Sagnac Fiber Optic Sensor Array)

  • 이종길;이승홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.533-534
    • /
    • 2010
  • Fiber optic sensor has bee widely used in the industrial applications. For the application of acoustic detection of the high voltage electric transformer Sagnac interferometer can be used. In this paper several different materials of mandrel were used in the fiber sensor array. Based on the transformer oil fiber optic sensor is more sensitive than in the air.

  • PDF

대형 변압기의 밀폐장치용 소음기 개발 (Development of a Silencer for an Acoustic Enclosure of a Large Transformer)

  • 이준신;이욱륜;이대성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.786-789
    • /
    • 2005
  • An acoustic total or partial enclosure is widely used to reduce the sound pressure level propagating from a noise source. However, the performance of the acoustic enclosure is decreased by its inherent limitations such as temperature rise or acoustic pressure build up inside the enclosed acoustic field. In general, a silencer is installed to overcome these limitations, for large amount of air can be exchanged through the silencers. In this reason, a parallel baffle type duct silencer with acoustic resonators is studied to reduce the transmitted noise from a transformer. In this silencer, the high frequency components of the transmitted noise over 360Hz are effectively absorbed by the parallel baffles and the other ones, 120 and 240 Hz, are reduced due to the presence of Helmholtz resonators. Large sound attenuation is achieved by applying the sound resonating barrier to the large transformers in a substation.

  • PDF

옥외 전력선 통신을 위한 저압 변압기 노이즈에 대한 연구 (A Study of Low Voltage Transformer Noise in Outdoor Power Line Communication)

  • 조성민;김재철;김용성;이양진;정범진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.127-128
    • /
    • 2006
  • The noise is major obstacle element in power line communication. However, because power supply networks are not designed for communication, there are various noise sources. Accordingly, a study of characteristic and cause of noise generated in low voltage transformer is important for outdoor power line communication. In this paper, we measure low voltage transformer noise in 1-30MHz using spectrum analyzer. We analyze cause and pattern of noise considering partial discharge.

  • PDF

154[kV] 저소음 변압기의 현장적용 (The Field Applica1ion of The 154[kV] low Noise Transformers)

  • 권동진;구교선;우정욱
    • 조명전기설비학회논문지
    • /
    • 제23권8호
    • /
    • pp.124-129
    • /
    • 2009
  • 최근 생활수준의 향상과 세계적인 녹색성장 정책으로 환경에 대한 관심이 고조되어, 전력분야에서도 환경친화적인 설비가 요구되어 지고 있다. 이에 따라 전력용 변압기도 소음저감에 대한 연구가 진행되어, 최근 55[dBA]급 154[kV] 저소음 변압기가 개발되었다. 저소음 변압기는 소음레벨은 저감되었지만, 중량 및 부피의 증가, 고무댐퍼의 적용 등이 변화가 있다. 이로 인하여 현장적용시 시험, 수송, 설치 및 운용 등에 대한 면밀한 검토가 필요한 실정이다. 따라서 본 논문에서는 효과적인 현장적용을 위해 소음레벨 기준치, 수송중량, 설치공간, 장기운용에 대한 사항을 검토하였다.

의료용 SMPS 개발 및 노이즈 감소 대책에 대한 연구 (A Study on the Low Noise Medical SMPS)

  • 이정우;김응석;김기만;윤형로
    • 한국산학기술학회논문지
    • /
    • 제2권1호
    • /
    • pp.53-58
    • /
    • 2001
  • Switching Mode Power Supply(SMPS)에서 전자파 노이즈 발생의 주된 요인은 스위칭 소자, 2차측 정류 다이오드, 그리고 출력 트랜스포머 및 쵸크 코일의 세부분이다. 본 논문에서는 노이즈 특성을 정량화 하기 어려운 트랜스포머에 초점을 맞추고, 보빈의 형태, 권선 방법에 따른 노이즈를 분석하고 최적 트랜스포머를 설계 하였다. 이들의 비교 분석을 위해 전자파 전도노이즈, 스위칭 소자의 스위칭 파형, 출력의 리플/노이즈 전압, 누설 전류의 4가지 특성을 측정하였다. 이 결과 수직 형태의 보빈과 1ㆍ2차 병렬 샌드위치 권선법을 사용한 트랜스포머의 경우가 가장 좋은 특성을 나타냄을 알 수 있었고, 이를 바탕으로 최적의 트랜스포머를 제안하였다. 전기적 특성과 안전 규격에 대한 실험을 통해 개발된 SMPS가 의료기용 국제 규격인 IEC 601-1을 만족함을 확인하였다.

  • PDF

외부 코로나 노이즈를 제거한 내부 부분방전 측정기법 (An internal partial discharge measurement method excepted an external corona noise)

  • 권동진;진상범;곽희로
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.44-50
    • /
    • 2001
  • 현재까지 운전중인 변압기에 전기적인 부분방전 측정기법을 적용하기 위한 가장 큰 문제점은 외부 코로나 노이즈를 제거하는 것이다. 본 논문에서는 외부 코로나 노이즈를 제거하고 변압기 내부의 결함에 의한 부분방전 신호만을 측정하는 기법에 대하여 연구하였다. 현장에서 운전중인 변압기에서의 부분방전과 코로나 노이즈의 발생 형태를 모의하기 위하여 모의 변압기 내에 침-평판 전극을 이용하여 변압기 내부 부분방전을 발생시켰으며, 동시에 변압기 외부의 공기 중에 봉-구 전극을 이용하여 외부 코로나 노이즈를 발생시켰다. 변압기 접지선에 설치한 로고우스키 코일에는 변압기의 내부 결함에 의해 발생되는 부분방전 신호와 외부 코로나 노이즈가 동시에 측정되었다. 변압기 외부에 안테나 센서를 이용하여 외부 코로나 노이즈를 별도로 측정하여, 코로우스키 코일에서 측정된 신호에서 코로나 노이즈를 제거한 결과, 변압기 내부의 부분방전에 의한 신호만을 효과적으로 검출할 수 있었다.

  • PDF

Vibration Analysis of Transformer DC bias Caused by HVDC based on EMD Reconstruction

  • Liu, Xingmou;Yang, Yongming;Huang, Yichen
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.781-789
    • /
    • 2018
  • This paper proposes a new approach utilizing empirical mode decomposition (EMD) reconstruction to process vibration signals of a transformer under DC bias caused by high voltage direction transmission (HVDC), which is the potential cause of additional vibration and noise from transformer. Firstly, the Calculation Method is presented and a 3D model of transformer is simulated to analyze transformer deformation characteristic and the result indicate the main vibration is produced along axial direction of three core limbs. Vibration test system has been built and test points on the core and shell of transformer have been measured. Then, the signal reconstruction method for transformer vibration based on EMD is proposed. Through the EMD decomposition, the corrupted noise can be selectively reconstructed by the certain frequency IMFs and better vibration signals of transformer have been obtained. After EMD reconstruction, the vibrations are compared between transformer in normal work and with DC bias. When DC bias occurs, odd harmonics, vibration of core and shell, behave as a nonlinear increase and the even harmonics keep unchanged with DC current. Experiment results are provided to collaborate our theoretical analysis and to illustrate the effectiveness of the proposed EMD method.

전력용 변압기 소음저감을 위한 차음판 기술에 관한 연구 (A Study on the Soundproofing Plate Techniques for Noise Reduction of Power Transformers)

  • 권동진;구교선;김정찬;김진
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.47-55
    • /
    • 2008
  • 전력수요의 증가와 도심지역의 확대로 주거지역에 새로운 변전소를 건설하거나, 기존 변전소에 변압기 증설이 필요하다. 그러나 변전소의 변압기 소음으로 인한 불만이 증가하고 있다. 지금까지 한전에서는 변압기의 소음전달을 차단하기 위하여 옥외 변전소의 경우에는 방진패드 설치, 다양한 방음벽 설치, 변압기 본체 밀폐 등을 시행하여 왔으며, 옥내 변전소의 경우에는 방음문, 방음서터 및 풍도형 방음장치 설치 등을 시행하여 왔다. 그러나 현재의 소음 저감대책은 만족할 정도에 이르지 못하는 실정이다. 따라서 변압기 자체의 소음발생 억제에 대한 근본적인 대책이 요구되고 있다. 본 연구에서는 변압기 외함의 보강제 사이를 강판으로 막아 변압기 외함에서 방출되는 소음을 차단하기 위한 차음판 기술을 개발하였다. 차음판을 변압기 외함에 적용하기 위하여 변압기 외함의 진동 특성과 차음판의 적용에 따른 음의 감쇄를 해석하고, 실변압기에 차음판을 적용하여 소음의 저감효과를 측정하여 약 11[dB]의 소음저감 효과를 확인하였다.

고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터 (Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise)

  • 이성호;권정민;권봉환
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

변압기 부분방전과 노이즈에 의한 초음파 신호 분석 (Analysis of the Ultrasonic Signals by the Partial Discharge and Noises from the Transformer)

  • 권동진;정길조;진상범;곽희로
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.354-360
    • /
    • 2002
  • The partial discharge detecting method using the ultrasonic technique has been investigated to monitor the insulation ageing of a transformer. However, the result of the studies on the ultrasonic technique for detecting of partial discharge in the operating transformer is not enough yet to utilize. This paper presents the analysis of the ultrasonic signals due to the partial discharge in a model transformer and the corona in air at a shielded high voltage room. In addition, the ultrasonic signals due to the vibration from the core, operation of the cooling pump, the fan and the OLTC at the 345㎸ power transformer, were analyzed and corona noise from overhead transmission line in 345㎸ substation were measured to remove the electrical and mechanical noises from the transformer. Furthermore, ultrasonic signal due to the partial discharge in the 154㎸ power transformer with in $C_2$$H_2$ gas warning condition was measured. The inside of the transformer was examined with care. which confirms the existence of the partial discharge source.