• Title/Summary/Keyword: Transformation power

Search Result 691, Processing Time 0.025 seconds

Analytic Solution to Mild Slope Equation for Transformation of Waves Propagating over an Axi-symmetric Pit (축대칭 함몰지형 위를 진행하는 파의 변형에 관한 완경사 방정식의 해석 해)

  • Jung, Tae-Hwa;Suh, Kyung-Duck
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.4
    • /
    • pp.308-320
    • /
    • 2006
  • An analytic solution to the mild-slope equation is derived for waves propagating over an axi-symmetric pit. The water depth inside the pit varies in proportion to a power of radial distance from the pit center. The governing equation is transformed into ordinary differential equations by using separation of variables, and the coefficients of the equations are transformed into explicit forms by using Hunt's (1979) approximate solution. Finally, by using the Frobenius series, the analytic solution is derived. Due to the feature of Hunt's equation, the present analytic solution is accurate in shallow and deep waters, while it is less accurate in intermediate depth water. The validity of the analytic solution is demonstrated by comparison with numerical solutions. The analytic solution is also used to examine the effects of pit geometry and relative depth on wave transformation.

Transformation Method for a State Machine to Increase Code Coverage (코드 커버리지를 높이기 위한 상태 머신 변환 방법)

  • Yoon, YoungDong;Choi, HyunJae;Chae, HeungSeok
    • Journal of KIISE
    • /
    • v.43 no.9
    • /
    • pp.953-962
    • /
    • 2016
  • Model-based testing is a technique for performing the test by using a model that represents the behavior of the system as a system specification. Industrial domains such as automotive, military/aerospace, medical, railway and nuclear power generation require model-based testing and code coverage-based testing to improve the quality of software. Despite the fact that both model-based testing and code coverage-based testing are required, difficulty in achieving a high coverage using model-based testing caused by the abstraction level difference between the test model and the source code, results in the need for performing model-based testing separately. In this study, to overcome the limitations of the existing model-based testing, we proposed the state machine transformation method to effectively improve the code coverage using the protocol state machine, one of the typical modeling methods is used as the test model in model-based testing, as the test model. In addition, we performed a case study of both systems and analyzed the effectiveness of the proposed method.

The Strategic Decision Supports using Knowledge Transformation Process (지식변환과정을 활용한 전략적 의사결정지원 방법론에 관한 연구)

  • Park, Ki-Nam
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.13 no.5
    • /
    • pp.55-65
    • /
    • 2008
  • The strategic decision makers of the firm have faced with uncertainty and complexity. Although they must make decision under these environments, they can't have enough time, man power, budget and knowledge that they need to decide. They can't, therefore, help getting supports by experts who have implicit knowledge about the domain. But it is difficult for them to find any other procedures and methods to create, transform, combine, and apply new knowledges, whenever decision makers face the problem This paper provides a new method to support a strategic decision making by using the knowledge transformation process suggested by Nonaka. We illustrate an application case of the strategic decision making in consulting industry. This paper uses cognitive map as a decision support technology based on the suggested method.

  • PDF

A Review Method of Calculation Results on Cable Ampacity using the Transformation to Electric Equivalent Circuit from Cable Thermal Circuit (케이블 열회로의 전기적 등가회로 변환을 이용한 케이블 허용전류 검토 방법)

  • Kang, Yeon-Woog;Kim, Min-Ju;Jang, Tae-In;Park, Jin-Woo;Park, Hung-Sok;Kang, JI-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.738-744
    • /
    • 2016
  • Current rating of a power cable can be calculated by the maximum allowable temperature in an insulating material considering the heat transfer from cable conductor. Therefore, it is very important to calculate the current rating using electrical equivalent circuit by calculated cable thermal circuit parameters but, it has not been fully investigated yet. In this paper, in order to determine the current rating of power cable, conventional calculation method has been reviewed considering the conductor resistance, loss factor of sheath, dielectric losses and thermal resistances based on the maximum allowable temperature of 345 kV $2500mm^2$ XLPE cable. To confirm the calculation result of the current rating, the conductor temperature should be examined whether it reaches the maximum allowable temperature by the thermal equivalent circuit of the cable. Then, utilizing EMTP (Electro-Magnetic Transient Program) which is a conventional program for electrical circuit, the thermal equivalent circuit was transformed to an electric equivalent circuit using an analogous relationship between thermal circuit and electrical circuit, and temperature condition including cable conductor, sheath, cable jacket could be calculated by the current rating of 345 kV $2500mm^2$ XLPE cable.

Non-linear Regression Model Between Solar Irradiation and PV Power Generation by Using Gompertz Curve (Gompertz 곡선을 이용한 비선형 일사량-태양광 발전량 회귀 모델)

  • Kim, Boyoung;Alba, Vilanova Cortezon;Kim, Chang Ki;Kang, Yong-Heack;Yun, Chang-Yeol;Kim, Hyung-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.113-125
    • /
    • 2019
  • With the opening of the small power brokerage business market in December 2018, the small power trading market has started in Korea. Operators must submit the day-ahead estimates of power output and receive incentives based on its accuracy. Therefore, the accuracy of power generation forecasts is directly affects profits of the operators. The forecasting process for power generation can be divided into two procedure. The first is to forecast solar irradiation and the second is to transform forecasted solar irradiation into power generation. There are two methods for transformation. One is to simulate with physical model, and another is to use regression model. In this study, we found the best-fit regression model by analyzing hourly data of PV output and solar irradiation data during three years for 242 PV plants in Korea. The best model was not a linear model, but a sigmoidal model and specifically a Gompertz model. The combined linear regression and Gompertz curve was proposed because a the curve has non-zero y-intercept. As the result, R2 and RMSE between observed data and the curve was significantly reduced.

Active Frequency with a Positive Feedback Anti-Islanding Method Based on a Robust PLL Algorithm for Grid-Connected PV PCS

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.360-368
    • /
    • 2011
  • This paper proposes an active frequency with a positive feedback in the d-q frame anti-islanding method suitable for a robust phase-locked loop (PLL) algorithm using the FFT concept. In general, PLL algorithms for grid-connected PV PCS use d-q transformation and controllers to make zero an imaginary part of the transformed voltage vector. In a real grid system, the grid voltage is not ideal. It may be unbalanced, noisy and have many harmonics. For these reasons, the d-q transformed components do not have a pure DC component. The controller tuning of a PLL algorithm is difficult. The proposed PLL algorithm using the FFT concept can use the strong noise cancelation characteristics of a FFT algorithm without a PI controller. Therefore, the proposed PLL algorithm has no gain-tuning of a PI controller, and it is hardly influenced by voltage drops, phase step changes and harmonics. Islanding prediction is a necessary feature of inverter-based photovoltaic (PV) systems in order to meet the stringent standard requirements for interconnection with an electrical grid. Both passive and active anti-islanding methods exist. Typically, active methods modify a given parameter, which also affects the shape and quality of the grid injected current. In this paper, the active anti-islanding algorithm for a grid-connected PV PCS uses positive feedback control in the d-q frame. The proposed PLL and anti-islanding algorithm are implemented for a 250kW PV PCS. This system has four DC/DC converters each with a 25kW power rating. This is only one-third of the total system power. The experimental results show that the proposed PLL, anti-islanding method and topology demonstrate good performance in a 250kW PV PCS.

Lane Detection Algorithm for Night-time Digital Image Based on Distribution Feature of Boundary Pixels

  • You, Feng;Zhang, Ronghui;Zhong, Lingshu;Wang, Haiwei;Xu, Jianmin
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.188-199
    • /
    • 2013
  • This paper presents a novel algorithm for nighttime detection of the lane markers painted on a road at night. First of all, the proposed algorithm uses neighborhood average filtering, 8-directional Sobel operator and thresholding segmentation based on OTSU's to handle raw lane images taken from a digital CCD camera. Secondly, combining intensity map and gradient map, we analyze the distribution features of pixels on boundaries of lanes in the nighttime and construct 4 feature sets for these points, which are helpful to supply with sufficient data related to lane boundaries to detect lane markers much more robustly. Then, the searching method in multiple directions- horizontal, vertical and diagonal directions, is conducted to eliminate the noise points on lane boundaries. Adapted Hough transformation is utilized to obtain the feature parameters related to the lane edge. The proposed algorithm can not only significantly improve detection performance for the lane marker, but it requires less computational power. Finally, the algorithm is proved to be reliable and robust in lane detection in a nighttime scenario.

Earth Reflection Effect Analysis in the Environment of Line Source Induction (전력선 유도 환경에서의 지면 반사계 영향 분석)

  • Lee, Sangmu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.26-32
    • /
    • 2013
  • The earth reflection effect on the induced voltage by line source such as power line occurring induction inteference is analyzed to scrutinize how much it would reduce the induced voltage. Using hankel transformation including bessel function, directly calculation formulae for extracting a refelction coefficient is a most important technical application in this paper since the reflection coefficient on the earth cannot be deduced by a general coefficient calculation formulae according to a plain wave. The electric field is utilized to transform the electromagnetic field into an induced voltage. The composed efficiency to a source induction voltage by an earth reflection is about a range of 60~70% for the axis constellation of each object like observation point, source position and other material parameters.

Development of Boost Type Bidirectional ZCS DC/DC Converter For EV of Transformer Series Construction (변압기 직렬구조의 EV용 승압형 양방향 ZCS DC/DC 컨버터 개발)

  • Choi, Jung-Sik;Park, Byung-Chul;Chung, Dong-Hwa;Song, Sung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.37-46
    • /
    • 2013
  • This paper proposes the boost type bidirectional zero current switching(ZCS) DC/DC converter of transformer series construction for electric vehicle operation using low voltage battery. This converter can high boost through the double voltage circuit and series construction of output part using two converters. This converter system has the advantages that bidirectional power transfer is excellent, size and making of transformer because of this converter keeps the transformation ratio to 1:1. Proposed DC/DC converter uses the ZCS method to decrease the switching loss. By replacing reactance ingredients of L-C resonance circuit for ZCS with leakage inductance ingredients of high frequency transformer and half-bridge capacitor it reduces system size and expense because of not add special reactor. It can confirm to output of high voltage to operate the electric vehicle with low voltage of input and operation of ZCS in all load region through the result of PSIM simulation and experiment.

Rank Transformation Technique in a Two-stage Two-level Balanced Nested Design (이단계 이수준 균형지분모형의 순위변환 기법연구)

  • Choi Young-Hun
    • The Korean Journal of Applied Statistics
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2006
  • In a two-stage two-level balanced nested design, type I error rates for the parametric tests and the rank transformed tests for the main effects and the nested effects are in overall similar to each other. Furthermore, powers for the rank transformed statistic for the main effects and the nested effects in a two-stage two-level balanced nested design are generally superior to powers for the parametric statistic When the effect size and the sample size are increased, we can find that powers increase for the parametric statistic and the rank transformed statistic are dramatically improved. Especially for the case of the fixed effects in the asymmetric distributions such as an exponential distribution, powers for the rank transformed tests are quite high rather than powers for the parametric tests.