• Title/Summary/Keyword: Transfer-in

Search Result 25,802, Processing Time 0.05 seconds

Recipient S-CSCF Assured (RSA) Session Transfer for IMS based NGN

  • Yun, Chang-Ho;Cho, A-Ra;Kim, Seung-Geun;Park, Jong-Won;Lim, Yong-Kon
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.4
    • /
    • pp.355-364
    • /
    • 2010
  • A session transfer method, referred to as a Recipient Serving-call session control function (S-CSCF) Assured (RSA), is proposed in order to support both session mobility and consistency in IP multimedia subsystem (IMS) based next generation network (NGN). RSA session transfer simplifies a basic session transfer operation specified in [1] by using the user agent client (UAC) like characteristics of an S-CSCF. To show its efficiency, the session transfer delay and the traffic cost of RSA session transfer are investigated and compared with those of existing session transfer applications, including Assured and Consultative session transfers, by practically considering multiple session transfer failures. It is shown that RSA session transfer can further improve user experience by reducing session transfer delay as well as traffic cost than Assured and Consultative session transfers.

A Study on the influence of job transfer in E&T programs characteristics & organizational situational characteristics of the medium and small-sized hospitals (중소병원의 교육훈련 프로그램 특성 및 조직상황적 특성이 직무전이에 미치는 영향에 관한 연구)

  • Kim, Young-Hyuk
    • Korea Journal of Hospital Management
    • /
    • v.16 no.4
    • /
    • pp.131-160
    • /
    • 2011
  • The purpose of this study was 1) to understand the job transfer in education & training(E&T) programs & organizational situational characteristics, and 2) to analyze the effects of the E&T programs & organizational situational characteristic groups on each of the levels of job transfer. There is intimate relationship between E&T programs characteristics & organizational situational characteristics and job transfer, so we can't think of them separately. With this point of view the most frequently discussed problem is how to apply the theory in actual job, but in reality it's true that the improvement of job transfer can't reach the expectations of the E&T programs. In literature view study, the concepts of job transfer in E&T, the general theory on E&T, and the actual condition and points at issue of the existing E&T practices in the medium and small-sized hospitals were defined. As the results from empirical analysis, we could find followings: First, in evaluation of the job transfer, demographic characteristics (seniority, occupational category, position) variables have a significant different. Second, in degree of the job transfer, E&T programs characteristics(contents of E&T, design of E&T, conditions of E&T, teaching ability of lecturer, methods of E&T) variables have a different influence upon each of the evaluation levels of E&T. Third, support of CEO variables have a different influence on the job transfer according to contents, design, conditions of the E&T programs. Fourth, support of co-works variables have a different influence on the job transfer according to design, conditions, method of the E&T programs. Fifty, support of organizational atmosphere variables have a different influence on the job transfer according to contents, design, conditions of the E&T programs.

  • PDF

Cross modal Transfer in Infancy : Transfer from Touch to Vision (유아의 감각양식간 전이 - 촉각에서 시각으로의 전이 -)

  • Hong, Hee Young
    • Korean Journal of Child Studies
    • /
    • v.7 no.1
    • /
    • pp.67-84
    • /
    • 1986
  • The purpose of the present research was to investigate cross-modal transfer, especially tactual-to-visual transfer in infancy and to study the relation between failure of cross-modal transfer performance and length of familiarization period. The subjects of this study were 60 infants, 10 boys and 10 girls at each level: six, nine, and twelve months of age. All were normal, healthy, full-term babies. The mothers' educational achievement was controlled at more than 12 years of schooling. There were two separate experimental conditions, one 30-sec and one 60-sec familiarization period. Each experimental condition consisted of a tactual familiarization and a visual recognition memory test. Each child was presented with these 2 sets of cross-modal stimuli in one of the 2 experimental conditions. Infants' visual responses in the visual recognition memory test were videotaped for 20 seconds. Visual fixation time to novel and familiar stimuli was observed throughout the test. The data was analyzed with t-test, percentage of total fixation time to novel stimuli, and ANOVA. The results showed that: 1) Significant differences were found in the cross-modal transfer performance from touch to vision between the 3 age groups. This is, 6 and 9 month old infants didn't show cross-modal transfer in the 30-sec condition, but 12 month old infants did show cross-modal transfer in the 30-second. 2) In all 3 age groups, no significant differences were found in cross-modal transfer performance between the two conditions.

  • PDF

Measuring Convective Heat Transfer Coefficient Around a Heated Fine Wire in Cross Flow of Nanofluids (나노유체의 수직유동 속에 놓인 가는 열선주위의 대류열전달계수 측정)

  • Lee, Shin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.2
    • /
    • pp.117-124
    • /
    • 2008
  • Recent researches on nanofluids have mainly focused on the increase of thermal conductivity of nanofluids under static condition. The ultimate goal of using nanofluids, however, is to enhance the heat transfer performance under fluid flow. So it has been highly necessary to devise a simple and accurate measuring apparatus which effectively compares the heat transfer capability between the base and nanofluids. Though the convective heat transfer coefficient is not the complete index for the heat transfer capability, it might be one of useful indications of heat transfer enhancement. In this article, the working principles of experimental system for convective heat transfer coefficient around a heated fine wire in cross flow of nanofluids and its application example to three samples of nano lubrication oils are explained in detail.

The Effect of Fiber Type, Compressional Resilience and Moisture Transport Properties of Fiber on the Heat Transfer of Insulating Nonwovens (섬유의 종류와 압축특성 및 수분전달특성이 보온용 부직포의 열전달에 미치는 영향)

  • 김희숙;김은애
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.4
    • /
    • pp.647-654
    • /
    • 1996
  • The purpose of this study was to analyze the effect of fiber type, compressional resilience and moisture transport properties of wool and polyester fiber on the heat transfer of insulation nonwovens. The results obtained were as follows: 1) Overall heat transfer of wool nonwoven was slightly higher than that of polyester nonwovens. Warmability of wool nonwoven was lower than that of polyester nonwovens. The radiative heat transfer was in the range of 11~18% of overall heat transfer in polyester nonwovens and 25% in wool nonwoven. 2) As wool nonwoven compressed, overall heat transfer was increased by increasing radiative heat transfer and wamability was decreased due to the poor compressional resilience. 3) Increasing rate of heat transfer by moisture absorption in wool nonwoven was lower than that of polyester nonwovens. Thickness and compressional resilience of wool nonwoven were reduced extremely by moisture absorption.

  • PDF

Performance and Heat Transfer Characteristics of Heat Pump System Using Refrigerant Mixtures (혼합냉매를 사용한 열펌프 시스템의 성능과 열전달 특성)

  • Kim, T.S.;Shin, J.Y.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.360-369
    • /
    • 1992
  • A heat pump system is constructed to evaluate its performance and heat transfer characteristics with mixtures of R22/R142b as working fluids. The heat transfer in the evaporator and the overall performance are measured and analyzed in terms of the compositions and relevant variables. Possibility of capacity modulation by changing composition is observed without degradation of heat transfer coefficients and coefficient of performance. The cooling capacity is varied continuously within 200 percent based on minimum capacity at constant compressor speed. For similar cooling capacity, COP is improved by mixing two refrigerants and shows maximum value at 60% mass fraction of R22. Average heat transfer coefficients of mixtures decrease in comparison with pure refrigerants at similar cooling capacity and mass flow rate. However, the overall heat transfer coefficients decrease moderately. A cycle simulation is performed in order to manifest the advantages of using refrigerant mixtures, considering experimentally observed heat transfer characteristics.

  • PDF

Characteristics of Vertical Vibration Transfer in Vertical Way according to Shear Wall Apartment Structures due to Heel-drop Impact (발 뒤꿈치 충격에 의한 전단벽식 공동주택 수직진동의 수직방향 진동전달 특성)

  • Chun, Ho-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.70-73
    • /
    • 2006
  • Recently, several researches have been performed on the prediction of vertical vibration on structures by using an analytical method. However, these studies have been focused on mainly the vibration analysis through analytical modeling of structures. This study aims to investigate the characteristics of vertical vibration transfer in terms of the directions of transfer(upward transfer and downward transfer) on the shear wall building structures due to heel-drop impact forces. In order to examine the characteristics of vertical vibration transfer, the mode analysis and the impact experiment were conducted several times on two shear wall building structures. The results of this study suggest that the characteristics of vertical vibration transfer are similar in terms of the directions of transfer.

  • PDF

Effect of S on Arc Stability of MAG Welding (MAG용접의 Arc안정성에 미치는 S의 영향)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • v.17 no.1
    • /
    • pp.55-61
    • /
    • 1999
  • The effect of S content in welding wires on the arc stability was investigated, in the region of short circuit transfer and spray transfer. In the region of short circuit transfer, with increasing S content, average arcing time and average short circuit time were decreased. Therefore, droplet transfer frequency was increased, due to the reduction of arcing time and peak current at the moment of arc-reiginition was decreased, due to the decrease of short circuit time. In the region of spray transfer, the fluctuation degree of arc current and arc voltage became more stable, with increasing S content.

  • PDF

Multiple Hint Information-based Knowledge Transfer with Block-wise Retraining (블록 계층별 재학습을 이용한 다중 힌트정보 기반 지식전이 학습)

  • Bae, Ji-Hoon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.2
    • /
    • pp.43-49
    • /
    • 2020
  • In this paper, we propose a stage-wise knowledge transfer method that uses block-wise retraining to transfer the useful knowledge of a pre-trained residual network (ResNet) in a teacher-student framework (TSF). First, multiple hint information transfer and block-wise supervised retraining of the information was alternatively performed between teacher and student ResNet models. Next, Softened output information-based knowledge transfer was additionally considered in the TSF. The results experimentally showed that the proposed method using multiple hint-based bottom-up knowledge transfer coupled with incremental block-wise retraining provided the improved student ResNet with higher accuracy than existing KD and hint-based knowledge transfer methods considered in this study.

The Experimental Study on Mist Cooling Heat Transfer (초음파진동을 이용한 미세분무냉각 열전달에 관한 실험적 연구)

  • Kim, Yeung-Chan
    • Journal of ILASS-Korea
    • /
    • v.15 no.4
    • /
    • pp.202-207
    • /
    • 2010
  • Mist cooling is widely employed as a cooling technique of high temperature surfaces, and it has heat transfer characteristics similar to boiling heat transfer which has the convection, nucleate and film boiling regions. In the present study, mist cooling heat transfer was experimentally investigated for the mist flow impacting on the heated surfaces of mico-fins. The mist flow was generated by supersonic vibration. Experiments were conducted under the test conditions of droplet flow rate, $Q=6.02{\times}10^{-9}{\sim}3.47{\times}10^{-8}\;m^3/s$ and liquid temperature, $T_f=30{\sim}35^{\circ}C$. From the experimental results, it is found that an increase in the droplet flow rate improves mist cooling heat transfer in the both case of smooth surface and surfaces of micro-fins. Micro-fins surfaces enhance the mist cooling heat transfer. Besides, the experimental results show that an increase in the droplet flow rate decrease the heat transfer efficiency of mist cooling.