• Title/Summary/Keyword: Transfer unit

Search Result 847, Processing Time 0.027 seconds

A Study on Perimeter Load Transfer Fuctions of the Large Diameter Drilled Shafts Depending on Soil Types During the Static Pile Load Tests (정재하시험시 지반종류별 대구경 현장타설말뚝의 주면하중전이함수에 관한 연구)

  • Jung, Ho-Young;Hwang, Seong Chun;Choi, Yongkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5C
    • /
    • pp.163-170
    • /
    • 2011
  • Perimeter load transfer functions were developed by an analysis of the static pile load test results of the 7 large diameter drilled shafts constructed in domestic areas. Using the pile axial load distributions obtained from the static pile load tests of large diameter drilled shafts, the unit skin frictions were analyzed and, based on unit skin friction test data, perimeter load transfer functions could be suggested. The load transfer distributions calculated by suggested functions and the load transfer functions obtained from the bi-directional pile load tests were compared. As a result, the 2 load transfer distributions were coincided, respectively.

development of Underwater Data Communication System (I) -Echo Signal Transfer System- (수중 데이터 통신 시스템의 개발에 관한 연구 (I) -에코 신호 전송 시스템-)

  • 신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.284-290
    • /
    • 1999
  • This paper describes a Frequency Shift Keying (FSK) modulator and demodulator and the experimented underwater data ommunication equipment to transfer the analog echo signal in real-time from an underwater vehicle to the mother ship. The system consists of an echo signal transfer unit equipped to the vehicle and an ultrasonic receiver equipped on the ship. The former includes an ultrasonic transceiver unit of 180kHz for echo detection and a continuous wave transmitter of 50kHz with a FSK modulator for echo transmission to the ship. The latter includes an ultrasonic receiver of 50kHz and the FSK demodulator. The results of experiment are as follows. 1. The characteristics of the FSK modulating and demodulating circuits designed with the use of C-MOS IC 4046 was good and confirmed its usefulness in underwater data communication system.2. The prototype ultrasonic transceiver unit shows profitable driving power while the pulse duration was short less than 3 msec, but it was found that the driving power is not sufficient while the long pulse duration or continuous wave is used. The gain of the ultrasonic receiver was 80 dB and the receiving bandwidth 700Hz (at - 3 dB point).3. It was found that the system designed by the author has some possibility to use in underwater echo transfer.4. At the FSK modulator, the widths of voltage and frequency which represent linearity were 3.5 V, 1600Hz, respectively, at the FSK demodulator 2.6 V, 700Hz, respectively.

  • PDF

development of Underwater Data Communication System (I) -Echo Signal Transfer System- (수중 데이터 통신 시스템의 개발에 관한 연구 (I) -에코 신호 전송 시스템-)

  • 신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.285-285
    • /
    • 1999
  • This paper describes a Frequency Shift Keying (FSK) modulator and demodulator and the experimented underwater data ommunication equipment to transfer the analog echo signal in real-time from an underwater vehicle to the mother ship. The system consists of an echo signal transfer unit equipped to the vehicle and an ultrasonic receiver equipped on the ship. The former includes an ultrasonic transceiver unit of 180kHz for echo detection and a continuous wave transmitter of 50kHz with a FSK modulator for echo transmission to the ship. The latter includes an ultrasonic receiver of 50kHz and the FSK demodulator. The results of experiment are as follows. 1. The characteristics of the FSK modulating and demodulating circuits designed with the use of C-MOS IC 4046 was good and confirmed its usefulness in underwater data communication system.2. The prototype ultrasonic transceiver unit shows profitable driving power while the pulse duration was short less than 3 msec, but it was found that the driving power is not sufficient while the long pulse duration or continuous wave is used. The gain of the ultrasonic receiver was 80 dB and the receiving bandwidth 700Hz (at - 3 dB point).3. It was found that the system designed by the author has some possibility to use in underwater echo transfer.4. At the FSK modulator, the widths of voltage and frequency which represent linearity were 3.5 V, 1600Hz, respectively, at the FSK demodulator 2.6 V, 700Hz, respectively.

Characteristics of Contaminant Transfer in a Clean Space for the Location of Product and Fan Filter Unit (청정공간에서 제품과 팬필터유닛의 위치에 따른 오염물질의 전파 특성)

  • Kim, Hyouk-Soon;Noh, Kwang-Chul;Lee, Young-Koo;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.452-457
    • /
    • 2008
  • We performed a study on the contaminant transfer in a clean space for the location of product and fan filter unit using computational fluid dynamics analysis. To simplify the real product moving process, three different non-moving cases regrading the locations of product were selected: no product, at the lower side, and at the upper and lower sides. And to investigate the characteristics of the contaminant transfer, the arrangement of fan filter units was varied. Local mean air-age and contaminant distribution were used as evaluation indices. From the results, the contaminant transfer to the product was the most when the products were simultaneously located at the upper and lower sides. And the contaminant was easily exhausted regardless of the location of product when the fan filter units were properly arranged at the top side of the clean space.

  • PDF

Heat Transfer Performance Variation of Condenser due to Non-uniform Air Flow (불균일한 풍속분포에 따른 응축기의 열전달 성능 변화)

  • Lee, Won-Jong;Jeong, Ji Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.193-198
    • /
    • 2014
  • Heat transfer performance variation of a condenser caused by non-uniform distribution of air flow was investigated using a numerical simulation method. A heat exchanger used for a outdoor unit of a commercial heat pump system and represented by a numerical model was selected. Non-uniform profile of air-velocity was constructed by measuring the air velocity at various locations of the outdoor unit. Simulation was conducted for various refrigerant circuits and air flow conditions. Simulation results show that the heat transfer capacity was reduced depending on the air-flow rate and the refrigerant circuit configuration. It is also shown that the capacity reduction rate is increased as the average air velocity decreases.

Insulation Performance Evaluation of the Curtain Wall Anchoring Unit by 3D Heat Transfer Simulation and Life Cycle Cost Analysis (3차원 전열해석 및 생애비용 분석을 통한 커튼월 앵커링 유닛의 단열성능 향상 방안 평가)

  • Kang, Seung-Hee;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.63-70
    • /
    • 2003
  • It is very important to improve the insulation performance of curtain wall anchoring unit since it is composed of materials with high thermal conductivity, such as aluminium, steel and so on. This study aims to evaluate the heating energy performance and economical efficiency of various alternatives which are different in position and material of insulation. As results, alternative of inserting the urethane washer & pad and coating the anchoring unit with urethane foam can improve the heating energy performance and L.C.C(Life Cycle Cost) by 6.33% and 0.95%, respectively, as compared with the existing case.

A Comparison of Roughness Measurement and Load Transfer Test for the Calculation of Unit Skin Friction of Pile Foundation in Soft Rocks (기초 연암부 벽면거칠기 시험과 하중전이 시험 결과의 비교 및 단위주면마찰력의 산정에 대한 연구)

  • Hong, Seok-Woo;Hwang, Geun-Bae
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.6
    • /
    • pp.21-30
    • /
    • 2023
  • One of the methods for calculating unit skin friction of soft-rock-socket parts for cast-in-place piles involves the roughness measurement of the parts. The measurements are conducted during the excavation stage. A roughness measuring device is installed in the excavation hole and the unit skin friction is calculated from the measured surface roughness of the rock socket. Herein, the results of roughness measurement of rock-socket parts in cast-in-place piles and that of load transfer tests are analyzed and compared. The unit skin friction from the roughness measurements can be converted into unit skin friction corresponding to the displacement of a pile generated in a load transfer test. A reduction factor is given as Rf = -0.14n + 1.48.

A Study on Dynamic Characteristics Analysis of Spindle Unit for Two-for-One Twister (투포원 연사기용 스핀들 유니트의 동특성 해석에 관한 연구)

  • Kim, Gwang-Yeong;Kim, Jong-Su
    • 연구논문집
    • /
    • s.27
    • /
    • pp.127-139
    • /
    • 1997
  • Two-for-one twister is a kind of textile machine and makes special fancy yarn which is twisted two times per one revolution in order to increase tensile strength and wear resis-tance of yarn. Spindle mechanism has to be stable and continuous motion in high speed revolution, and then optimal design is necessary to analyze dynamic characteristics of spindle unit. Spindle unit is consist of blade and rotary disc that are cylindrical body of revolution. For analysis of the dynamic characteristics of spindle unit, transfer matrix method is used and a numerical code SPINDLE also. Torsion and natural bending frequency of the spindle unit are examined. Its displacement mode is studied in function of variable revolutions.

  • PDF

EP Based PSO Method for Solving Multi Area Unit Commitment Problem with Import and Export Constraints

  • Venkatesan, K.;Selvakumar, G.;Rajan, C. Christober Asir
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.415-422
    • /
    • 2014
  • This paper presents a new approach to solve the multi area unit commitment problem (MAUCP) using an evolutionary programming based particle swarm optimization (EPPSO) method. The objective of this paper is to determine the optimal or near optimal commitment schedule for generating units located in multiple areas that are interconnected via tie lines. The evolutionary programming based particle swarm optimization method is used to solve multi area unit commitment problem, allocated generation for each area and find the operating cost of generation for each hour. Joint operation of generation resources can result in significant operational cost savings. Power transfer between the areas through the tie lines depends upon the operating cost of generation at each hour and tie line transfer limits. Case study of four areas with different load pattern each containing 7 units (NTPS) and 26 units connected via tie lines have been taken for analysis. Numerical results showed comparing the operating cost using evolutionary programming-based particle swarm optimization method with conventional dynamic programming (DP), evolutionary programming (EP), and particle swarm optimization (PSO) method. Experimental results show that the application of this evolutionary programming based particle swarm optimization method has the potential to solve multi area unit commitment problem with lesser computation time.