• Title/Summary/Keyword: Transfer resistance

검색결과 1,293건 처리시간 0.028초

KS F 2278을 적용한 대면적 시료 열관류율 시험 실측에 관한 연구 (An Experimental Study on Thermal Resistance of Large-scale Specimen Using KS F 2278)

  • 문재식;이원균;김영봉;조병영;노상태
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.306-307
    • /
    • 2018
  • In Korea, The thermal resistance test of window sets is performed according to KS F 2278 standard, and is performed only on a specimen size of 2000 × 2000 (mm). In this study, a standard panel measuring 4000 × 3000 (mm) size was used to measure the heat flux in each part of the specimen, and to calculate the resistance to heat transfer And to seize whether the KS F 2278 standard is applicable to large Specimen.

  • PDF

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석 (Analysis of energy consumption of office building by thermal resistance-capacitance method)

  • 이창선;최영돈
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF

하천에서 분리한 비소 내성세균의 유전적 특성 (Genetic Characteristics of Arsenic Compounds-Resistant Bacteria Isolated from Stream Water)

  • 정미경;이호자
    • 미생물학회지
    • /
    • 제29권1호
    • /
    • pp.63-68
    • /
    • 1991
  • Several arsenic compound-resistant bacteria were isolated from Jung-Rang stream. The isolates, D-3, D-12, and D-14 were characterized phenotypically and genetically, and identified as Serratia liquefaciens, Klebsiella oxytoca, and Klebsiella pneumoniae, respectively. A plasmid of 67kb was found in Klebsiella oxytoca D-12 and designated as pMH12. Transfer of this plasmid from D-12 to E. coli HB101 was occurred, and the resulting transconjugant strains expressed the same level of heavy metal resistance as the donor strain. The physical presence of this plasmid in transconjugant was detected with agarose gel electrophoresis. Arsenite-sensitive derivatives of isolate D-12 were obtained with Mitomycin C treatment which cured pMH12. Antibiotics and heavy metal resistances were also examined to be used as a proper marker for the isolates in gene cloning. Isolate D-12 has resistance to several heavy metal ions such as $Cd^{2+}$ , $Zn^{2+}$ and $Hg^{ 2+}$ Also, all the other arsenite resistant isolates showed resistance to several heavy metal ions and antibiotics.

  • PDF

은 박막이 코팅된 베어링 표면의 구름 저항 거동 고찰 (An Experimental Study on the Rolling Resistance of Bearing Surfaces Covered by Pure Silver Film)

  • 양승호;공호성;윤의성;권오관
    • Tribology and Lubricants
    • /
    • 제13권3호
    • /
    • pp.85-92
    • /
    • 1997
  • An experimental study was performed to discover the tribological behaviors of pure silver coated 52100 bearing steel. Pure silver coatings ranging from 80 nm to several micrometers were produced by a thermal evaporation coating method. Experiments using a thrust ball bearing-typed rolling test-rig were performed for the investigations of the influence of coating thickness on the tribological rolling behavior. The existence of optimum film thickness which revealed minimum rolling resistance was discovered. A careful analysis on the contact surfaces for the optimum film thickness has been performed. The contact patches produced by the transferred silver films played an important role for the rolling resistance to keep low.

An Experimental Investigation of Heat Transfer in Forced Convective Boiling of R 134a, R 123 and R 134a/R 123 in a Horizontal Tube

  • Lim, Tae-Woo;Kim, Jun-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • 제18권3호
    • /
    • pp.513-525
    • /
    • 2004
  • This paper reports an experimental study on flow boiling of pure refrigerants R l34a and R l23 and their mixtures in a uniformly heated horizontal tube. The flow pattern was observed through tubular sight glasses with an internal diameter of 10㎜ located at the inlet and outlet of the test section. Tests were run at a pressure of 0.6 MPa in the heat flux ranges of 5-50㎾/㎡, vapor quality 0-100 percent and mass velocity of 150-600㎏/㎡s. Both in the nucleate boiling-dominant region at low quality and in the two-phase convective evaporation region at higher quality where nucleation is supposed to be fully suppressed, the heat transfer coefficient for the mixture was lower than that for an equivalent pure component with the same physical properties as the mixture. The reduction of the heat transfer coefficient in mixture is explained by such mechanisms as mass transfer resistance and non-linear variation in physical properties etc. In this study, the contribution of convective evaporation, which is obtained for pure refrigerants under the suppression of nucleate boiling, is multiplied by the composition factor by Singal et al. (1984). On the basis of Chen's superposition model, a new correlation is presented for heat transfer coefficients of mixture.

복사에너지를 이용한 TIM소재의 방열 특성 향상을 위한 연구 (Study on Improvement of Heat Dissipation Characteristics of TIM Material Using Radiant Energy)

  • 황명원;김도형;정우창;정원섭
    • 한국표면공학회지
    • /
    • 제52권2호
    • /
    • pp.58-61
    • /
    • 2019
  • The aim of this study is to quantitatively demonstrate the possibility of heat transfer by thermal radiation by comparing heat transfer by conventional heat transfer and radiation by radiation. 1) The heat transfer was measured by using filler of TIM material with low thermal conductivity (CuS). As a result, heat transfer was easier than ceramic with high thermal conductivity ($Al_2O_3$ and $Si_3N_4$). 2) The reason for this is thought to be that the infrared wave due to radiation of the air diaphragm has moved easily. 3) From the above results, the heat dissipation of the TIM material indicates the possibility of heat transfer by thermal radiation.

정상상태(定常狀態)에 있어서 목재(木材)의 습기전달(濕氣傳達)과 투습속도(透濕速度) (Moisture Transfer and Velocity of Moisture Transmission by Wood in Steady State)

  • 이원희
    • Current Research on Agriculture and Life Sciences
    • /
    • 제10권
    • /
    • pp.41-47
    • /
    • 1992
  • 목재투습성에 관하여 다음과 같은 결과가 밝혀졌다. 1) 시편두께 0mm에 외삽한 투습저항값이 정(正)이므로 목재표면에서의 수분전달현상을 고려함이 인정되었다. 2) 목재내부의 함수율분포는 함수율 9%를 경계로 두 개의 직선으로 나타났다. 또 시편양측의 공기중 평형함수율이 9%이상일 때는 한 개의 직선으로 나타났다. 수분확산계수는 함수율 9%를 경계로 두 개의 일정한 값을 가지며, 이 값들은 오직 함수율에만 관계한다. 4) 수분이동량은 목재내의 함수율구배에 의존한다. 4) 목재의 수분전달계수는 시편두께에 의존하였다. 이 현상의 기구에 대해서는 아직 알 수 없다.

  • PDF

혹명나방 저항성벼(Cry1Ac1)의 병해 저항성 및 병원균으로의 유전자 전이 (Evaluation of Disease Resistance of a Leaffolder-resistant (Cry1Ac1) Rice Event and Gene Transfer to Plant Pathogens)

  • 남효송;심홍식;유상미;이세원;권순종;김명곤;이용훈
    • 식물병연구
    • /
    • 제15권3호
    • /
    • pp.202-208
    • /
    • 2009
  • 유전자 변형 혹명나방 저항성벼의 주요 병해에 대한 저항성 변화를 온실과 포장에서 모본으로 사용된 낙동벼와 비교하였다. 포장에서 벼잎집무늬마름병과 벼깨씨무늬병의 발병 정도는 큰 차이가 없었다. 온실에서 인위적으로 병원균을 접종하여 벼도열병과 흰잎마름병에 대해 저항성 변화여부를 조사한 결과에서도 두 품종간에 큰 차이를 보이지 않았고, 인위접종한 벼잎집무늬마름병에 대한 감수성도 두 품종간에 비슷하여 포장에서의 결과와 같은 경향을 보였다. 형질전환 벼의 제초제 저항성 유전자(Bar 유전자)와 혹병나방 저항성유전자(Cry1Ac1 유전자)가 병원균으로 전이되는가의 여부를 조사하기 위하여 포장에서 발병한 도열병과 키다리병원균을 분리한 후 DNA를 추출하여 PCR을 실시한 결과 두 유전자 모두 병원균으로 전이되지 않은 것으로 확인되었다. 또한, 병원균과 저항성벼의 지속적인 접촉에 의한 유전자 전이 가능성을 확인하기 위하여 잎집무늬마름병균과 흰잎마름병균을 계대 접종한 후 DNA를 분리하여 조사한 결과에서도 저항성 유전자의 전이는 일어나지 않은 것으로 확인되어, 본 실험에서는 자연상태와 인위적인 조건 모두에서 유전자 전이를 찾아 볼 수 없었다.

Chip-on-board 형 세라믹-메탈 하이브리드 기판을 적용한 50와트급 LED 어레이 모듈의 제조 및 방열특성 평가 (Fabrication and Evaluation of Heat Transfer Property of 50 Watts Rated LED Array Module Using Chip-on-board Type Ceramic-metal Hybrid Substrate)

  • 허유진;김효태
    • 마이크로전자및패키징학회지
    • /
    • 제25권4호
    • /
    • pp.149-154
    • /
    • 2018
  • 가로등 및 방폭등용 고출력 LED 조명 시스템의 광원으로서, 다수의 LED 칩이 실장된 50와트급 LED 어레이 모듈을 chip-on-board형 고방열 세라믹-메탈 하이브리드 기판을 사용하여 제작하였다. 고방열 세라믹-메탈 하이브리드 기판은 고열전도 알루미늄 금속 열확산 기판에 저온소결용 글라스-세라믹 절연 페이스트와 은 전극 페이스트를 후막 스크린 공정에 의해 도포한 다음, 건조 후 $515^{\circ}C$에서 동시소성하여 LED 칩을 실장할 세라믹 절연층과 은전극 회로층을 형성하여 제조하였다. 이 하이브리드 기판의 방열특성 평가를 위한 비교 샘플로서 기존의 에폭시 기반 FR-4 복합수지로 만든 써멀비아형 PCB 기판에도 동일한 디자인의 LED 어레이 모듈을 제작한 다음, 다중채널 온도측정장치와 열저항 측정기로 방열특성을 비교 분석하였다. 그 결과, $4{\times}9$ type LED 어레이 모듈에서 세라믹-메탈 하이브리드 기판의 열저항은 써멀비아형 FR-4 기판에 비하여 약 1/3로 나타났으며, 이것은 곧 방열성능이 적어도 3배 이상 높은 것으로 볼 수 있다.