• 제목/요약/키워드: Transfer resistance

검색결과 1,291건 처리시간 0.027초

대기질 - 강우산성도 관계식의 개발 (Development of Relationship between Air Quality and Rain Acidity)

  • 구자공;유동준
    • 한국대기환경학회지
    • /
    • 제2권3호
    • /
    • pp.45-51
    • /
    • 1986
  • The simple and precise model for the estimation of rain acidity from the ambient air quality was developed using the theory of wet scrubber and the chemical equilibria of $SO_2, CO_2, and H_2O$ system. From the measured mixing height, and from the developed relationship between NTU (=number of transfer units) and the concentration of $SO_2$(aq) in rain drops, the HTU (= height equivalent to one transfer unit, i.e. mass transfer resistance) was estimated, and validated with the field-measured data. In Seoul, Korea where the effect of $SO_2$ on rainfall acidity is as high as 84% and the average mixing height is 1 km, the average HTU of $SO_2$ system was found to be 191.5m. The important parameters affecting HTU were identified as rainfall intensity and initial ambient concentration of $SO_2$, and their effects on the value of overall volumetric mass transfer coefficient were quantified.

  • PDF

스크린 메쉬 윅을 삽입한 8mm 히트파이프에서 열전달 성능에 관한 실험적 연구 (An Experimental Study on Heat Transfer Performances in 8mm-diameter Heat Pipes with Screen Mesh Wick)

  • 박기호;이기우;노승용;이계중;유성연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.48-53
    • /
    • 2001
  • This experimental study is to research heat transfer characteristics in copper-water heat pipes with screen wick, the 150 and 200-mesh. Recent advances in the miniaturization and large capacity of electronic devices have had a major impact on the design of electronic equipment. As a result, a high-performance cooling system is needed. Experimental variables are inclination angle, number of layer and temperature of cooling water. The distilled water was used for the working fluid. At a inclination angle $6^{\circ}$, the 200-mesh screen wick 3-layer is shown the best heat transfer performance.

  • PDF

적층 스크린의 압력강하 및 열전달 특성 (Pressure Drop and Heat Transfer Characteristics of Multi-Layer Screen)

  • 송태호;안철우;김창기;고현진
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.419-425
    • /
    • 2000
  • Multiple layer of wire screen is widely used in many compact devices to filter particulates and to heat or cool fluids. However, data of flow resistance and heat transfer through such layers are rare to find and thus they are experimentally investigated in this study. Compressed air is made to flow through it to find the Ergun constants over a wide range of the Reynolds number. Also, unsteady heating of the wire screen is performed to find the equivalent heat transfer coefficient between the screen and the air by fitting the unsteady air temperature. The obtained coefficients are expressed in terms of the Reynolds number and the Prandtl number.

Dialysis in parallel-flow rectangular membrane modules with external reflux for improved performance

  • Yeh, Ho-Ming;Cheng, Tung-Wen;Chen, Kuan-Hung
    • Membrane and Water Treatment
    • /
    • 제1권2호
    • /
    • pp.159-169
    • /
    • 2010
  • The effect of external recycle on the performance of dialysis in countercurrent-flow rectangular membrane modules was investigated both theoretically and experimentally. Theoretical analysis of mass transfer in parallel-flow device with and without recycle is analogous to heat transfer in parallel-flow heat exchangers. Experiments were carried out with the use of a microporous membrane to dialyze urea aqueous solution by pure water. In contrast to a device with recycle, improvement in mass transfer is achievable if parallel-flow dialysis is operated in a device of same size with recycle which provides the increase of fluid velocity, resulting in reduction of mass-transfer resistance, especially for rather low feed volume rate.

Comparison between Water and N-Tetradecane as Insulation Materials through Modeling and Simulation of Heat Transfer in Packaging Box for Vaccine Shipping

  • Dao, Van-Duong;Jin, Ik-Kyu;Hur, Ho;Choi, Ho-Suk
    • 청정기술
    • /
    • 제22권1호
    • /
    • pp.45-52
    • /
    • 2016
  • This study reports on the modeling and simulation of heat transfer in packaging boxes used for vaccine shipping. Both water and n-tetradecane are used as primary insulation materials inside a multi-slab system. The one-dimensional model, which is a spherical model using a radius equivalent to the rectangular geometry of container, is applied in this study. N-tetradecane with low thermal diffusivity and proper phase transition temperature exhibits higher heat transfer resistance during both heating and cooling processes compared to water. Thus, n-tetradecane is a better candidate as an insulating material for packaging containers for vaccine shipping. Furthermore, the developed method can also become a rapid and economic tool for screening appropriate phase change materials used as insulation materials with suitable properties in logistics applications.

V형 원형휜-원형관의 강제대류 열유동 특성 (Forced Convection Characteristics of V type Circular-finned Tube Heat Exchanger)

  • 이종휘;임무기;강희찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1348-1354
    • /
    • 2009
  • The purpose of the present study is to investigate the flow resistance and the heat transfer characteristics of V type circular fin-tube heat exchanger. Four kinds of V type fin having the same fin area and the different span wise angle tested numerically. Test data for the heat transfer, pressure drop and fin temperature were shown and discussed. The pressure drop and heat transfer increased for decreasing the span wise angle up to 58% and 25% respectively.

  • PDF

화력발전소에서 용융회가 열전달 감소에 미치는 영향에 관한 연구 (A Study on the Heat Transfer Reduction due to the Clinker in the Thermal Poorer Plant)

  • 강희찬;이규욱
    • 동력기계공학회지
    • /
    • 제4권1호
    • /
    • pp.13-19
    • /
    • 2000
  • This study was conducted for the heat transfer reduction due to the clinker formed in the furnace of the thermal power plant. The thermal properties of clinker such as thermal conductivity, specific heat, density and void fraction were measured. The thermal conductivities of the clinker were ranged $0.32-0.54W/m{\cdot}K$ and the average specific heat and the void fraction were $930J/kg{\cdot}K$ and 0.36 respectively. The thermal resistance of clinker was the greatest among the thermal resistances. It was found that the clinker reduces more than 90% of the heat transfer if the clinker is thicker than 10 cm.

  • PDF

An Experimental Investigation of the Interfacial Condensation Heat Transfer in Steam/water Countercurrent Stratified Flow in a Horizontal Pipe

  • Chu, In-Cheol;Yu, Seon-Oh;Chun, Moon-Hyun;Kim, Byong-Sup;Kim, Yang-Seok;Kim, In-Hwan;Lee, Sang-Won
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.565-570
    • /
    • 1998
  • An interfacial condensation heat transfer phenomenon in a steam/water countercurrent stratified flow in a nearly horizontal pipe has been experimentally investigated. The present study has been focused on the measurement of the temperature and velocity distributions within the water layer. In particular, the water layer thickness used in the present work is large enough so that the turbulent mixing is limited and the thermal stratification is established. As a result, the thermal resistance of the water layer to the condensation heat transfer is increased significantly. An empirical correlation of the interfacial condensation heat transfer has been developed. The present correlation agrees with the data within $\pm$15%

  • PDF

착상을 수반한 멀티 가변속 열펌프의 동특성 (A Dynamic Characteristic of the Multi-Inverter Heat Pump with Frosting)

  • 박병덕;이주동;;황일남;장세동;황정하
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.337-345
    • /
    • 2003
  • In the case of heat exchangers operating under frosting condition, the growth of frost layer causes the heat exchanger to increase the thermal resistance and pressure loss of the air flow. In this paper, a transient characteristic prediction model of the heat transfer for multi inverter heat pump with frosting on its surface was presented taking into account the change of the fin efficiency due to the growth of the frost layer. In this dynamic simulation program, which was peformed for a basic air conditioning system model, such as evaporator, condenser, compressor, linear electronic expansion valve (LEV) and bypass circuit. The theoretical model was driven from the obtained heat transfer coefficient and mass transfer coefficient, independently. And we consider heat transfer performance was only affected by a decrease of the wind flow area. The calculated results were compared with some cases of experiments for frosting conditions.

불균일한 풍속분포에 따른 응축기의 열전달 성능 변화 (Heat Transfer Performance Variation of Condenser due to Non-uniform Air Flow)

  • 이원종;정지환
    • 설비공학논문집
    • /
    • 제26권4호
    • /
    • pp.193-198
    • /
    • 2014
  • Heat transfer performance variation of a condenser caused by non-uniform distribution of air flow was investigated using a numerical simulation method. A heat exchanger used for a outdoor unit of a commercial heat pump system and represented by a numerical model was selected. Non-uniform profile of air-velocity was constructed by measuring the air velocity at various locations of the outdoor unit. Simulation was conducted for various refrigerant circuits and air flow conditions. Simulation results show that the heat transfer capacity was reduced depending on the air-flow rate and the refrigerant circuit configuration. It is also shown that the capacity reduction rate is increased as the average air velocity decreases.