Metal/Organic Films/Metal에서 계면특성에 관한 연구 (A Study on the Interface Properties of Metal/Organic Films/Metal)

  • 송진원;조수영;최영일;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.723-726
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-$\gamma$ Benzyl $_D$-Glutamate/Al; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF

스마트 디바이스를 위한 3D 파라메트릭 CAD 시스템 (A 3D Parametric CAD System for Smart Devices)

  • 강윤아;한순흥
    • 한국CDE학회논문집
    • /
    • 제19권2호
    • /
    • pp.191-201
    • /
    • 2014
  • A 3D CAD system that can be used on a smart device is proposed. Smart devices are now a part of everyday life and also are widely being used in various industry domains. The proposed 3D CAD system would allow modeling in a rapid and intuitive manner on a smart device when an engineer makes a 3D model of a product while moving in an engineering site. There are several obstacles to develop a 3D CAD system on a smart device such as low computing power and the small screen of smart devices, imprecise touch inputs, and transfer problems of created 3D models between PCs and smart devices. The author discusses the system design of a 3D CAD system on a smart device. The selection of the modeling operations, the assignment of touch gestures to these operations, and the construction of a geometric kernel for creating both meshes and a procedural CAD model are introduced. The proposed CAD system has been implemented for validation by user tests and to demonstrate case studies using test examples. Using the proposed system, it is possible to produce a 3D editable model swiftly and simply in a smart device environment to reduce design time of engineers.

진동모터로 구성된 햅틱 디바이스를 이용한 장애물 정보 전달 및 제어 방법 (Obstacle Information Transfer and Control Method using Haptic Device consist of Vibration Motors)

  • 이동혁;노경욱;강선균;한종호;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제20권10호
    • /
    • pp.1036-1043
    • /
    • 2014
  • In this paper, a new haptic device is proposed for the teleoperation, which can recognize the invisible environment of a mobile robot. With this new device, it is possible for the user to identify the location of an obstacle and to avoid it. The haptic device has been attached on the top of a joystick so that the user can remotely control the mobile robot to avoid the obstacles which are recognized by the ultrasonic sensors. Also, the invisible environment is recognized more accurately overlapping the data from the ultrasonic sensors. There are five vibration motors in the haptic device to indicate the direction of the obstacle. So the direction of the obstacle can be recognized by the vibration at the finger on each vibration motor. For various situations and surrounding environments, experiments are performed using fuzzy controller and overlapping ultrasonic sensors. The results demonstrate the effectiveness of the proposed haptic joystick.

LB박막의 전자이동 특성에 관한 연구 (A Study on the Electronic Properties of LB Thin Films)

  • 송진원;최영일;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2002
  • Abstract We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Al; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF

Dissipative Replaceable Bracing Connections (DRBrC) for earthquake protection of steel and composite structures

  • Jorge M. Proenca;Luis Calado;Alper Kanyilmaz
    • Steel and Composite Structures
    • /
    • 제46권2호
    • /
    • pp.237-252
    • /
    • 2023
  • The article describes the development of a novel dissipative bracing connection device (identified by the acronym DRBrC) for concentrically braced frames in steel and composite structures. The origins of the device trace back to the seminal work of Kelly, Skinner and Heine (1972), and, more directly related, to the PIN-INERD device, overcoming some of its limitations and greatly improving the replaceability characteristics. The connection device is composed of a rigid housing, connected to both the brace and the beam-column connection (or just the column), in which the axial force transfer is achieved by four-point bending of a dissipative pin. The experimental validation stages, presented in detail, consisted of a preliminary testing campaign, resulting in successive improvements of the original device design, followed by a systematic parametric testing campaign. That final campaign was devised to study the influence of the constituent materials (S235 and Stainless Steel, for the pin, and S355 and High Strength Steel, for the housing), of the geometry (four-point bending intermediate spans) and of the loading history (constant amplitude or increasing cyclic alternate). The main conclusions point to the most promising DRBrC device configurations, also presenting some suggestions in terms of the replaceability requirements.

디스플레이용 판유리 이송을 위한 양방향 이송 로봇장치 (Full Duplex Robot System for Transferring Flat Panel Display Glass)

  • 이동훈;김성동;이치범;조영학
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.996-1002
    • /
    • 2013
  • This study addresses the development of a full duplex robotic system for transferring flat-panel display glass. We propose to accomplish this using a bidirectional linear transfer mechanism in place of the conventional rotary transfer mechanism. The developed full duplex robot comprises a driving part that carries the glass panel laterally, vertical part that can be moved up and down by means of a ball screw and linear motion guide arrangement, and hand part that slides by the cylinder of the driving part along the guide rail with a V-guide bearing attached to the bottom of the support. In addition, an alignment part prevents the hand part from derailing and holds the hand part while the driving part moves horizontally. The full duplex robot lifts and drives a glass panel directly while transferring it to the buffer and does not require rotational motion. Therefore, both transferring and stacking are realized with a single device. This device can be used in existing industrial facilities as an alternative to existing industrial robots in current as well as future process lines. The proposed full duplex robot is expected to save considerable amounts of time and space, and increase product throughput.

격자형 금형의 냉각효과를 고려한 구형 LNG 탱크용 대형 알루미늄 후판의 열간성형해석 (FE-Analysis of Hot Forming of Al Large Thick Plate for Spherical LNG Tank Considering Cooling Performance of Grid-Typed Die)

  • 이정민;이인규;김대순;권일근;이선봉;김병민
    • 한국정밀공학회지
    • /
    • 제29권11호
    • /
    • pp.1190-1198
    • /
    • 2012
  • A hot forming of large thick Al plate using a grid-type hybrid die is a process to make a shell plate for the production of a spherical LNG tank. This process is characterized by using a grid-typed die with an additional air cooling system for reducing the cooling time of the heated plate after hot forming. The process consists of the plate's feeding, heating, forming and cooling in detail and each of them is continuously performed along the rail. This paper was designed to propose the analytical and experimental methods for determining the convection and interfacial heat transfer coefficients required in hot forming analysis of Al plate. These values in the analysis are to reproduce numerically the cooling performance of grid-typed die and cooling device. Interfacial heat transfer was obtained from the heat transfer experiments for different pressures and inverse analysis method. To verify the efficiency of the coefficient values obtained from above methods, FE analysis and experiment of the hot spherical-forming process were conducted for a small-scaled model. The convection coefficient was also calculated from flow analysis of air released by cooling device within grid-typed die using ANSYS-CFX.

Timed Artificial Insemination or Embryo Transfer using CIDR, Estradiol Benzoate and Prostaglandin $F_{2{\alpha}}$ for the Rebreeding of Korean Native Donor Cattle

  • Son, Dong-Soo;Choe, Chang-Yong;Cho, Sang-Rae;Choi, Sun-Ho;Kim, Hyun-Jong;Lee, Je-In;Kim, Ill-Hwa
    • 한국수정란이식학회지
    • /
    • 제23권2호
    • /
    • pp.81-86
    • /
    • 2008
  • This study compared the pregnancy rates of Korean native donor cattle after either a timed artificial insemination (TAI) or embryo transfer (TET) following the synchronization of ovulation using a controlled internal drug release (CIDR) device together with estradiol benzoate (EB) and prostaglandin $F_{2{\alpha}}$ ($PGF_{2{\alpha}}$). Fifty five cows and 8 heifers which had been previously used for embryo production were assigned to two treatments: (1) Thirty-two cattle received a CIDR device and 2 mg EB (Day 0), 25 mg $PGF_{2{\alpha}}$ injection at the time of CIDR removal on Day 7, and 1 mg EB injection on Day 8. All of the cattle received a TAI 30 h (Day 9) after the second EB injection (TAI group). (2) Thirty-one cattle received the same hormonal treatments as in the TAI group. The cattle with corpus luteum (CL) received a TET on Day 16 using frozen-thawed embryos (TET group). Ultrasonographic observations demonstrated that the proportion of cattle with synchronized ovulation on Day 10 and the concomitant formation of new CL on Day 13 did not differ between groups (p>0.05); the overall mean rates were 65.1 and 73.0%, respectively. The conception and pregnancy rates did not differ (p>0.05) between the TAI (12.5% and 12.5%) and TET groups (13.0% and 9.7%), respectively. We conclude that the pregnancy rate following TAI or TET in Korean native donor cattle was poor, which might be due in part to a poor synchrony of ovulation and concomitant CL formation.

디지털 방송 서비스를 위한 AXMEDIS 암호화 툴 전송 모듈 설계 및 구현 (The Design and Implement of Transport Module for Digital Broadcasting Service)

  • 황경민;안상우;이주영;남제호;홍진우;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.913-916
    • /
    • 2008
  • 디지털 콘텐츠 시장의 성장은 다양한 콘텐츠 소비 장치의 개발을 유도하였고, 이는 디지털 콘텐츠의 소비를 더욱 촉진시켰다. AXMEDIS(Automating Production of Cross Media Content for Multichannel Distribution)는 다양한 플랫폼에서의 디지털 콘텐츠 소비를 지원하기 위해 AXMEDIS 프레임워크를 통한 다양한 디지털 방송 솔루션을 제공하고 있다. AXMEDIS 프레임워크는 단말에서의 디지털 콘텐츠 보호 및 소비를 위해 암호화 툴을 사용한다. 그러나 단말간의 유동적인 암호화 툴의 전송이 불가능하여 단말에서의 암호화 툴 관리가 불가능하다. 이에 본 논문에서는 AMEDIS 프레임워크에서 디지털 방송 콘텐츠의 보호와 소비를 유동적으로 운용 가능하도록 AXMEDIS 암호화 툴 전송 모듈을 설계 및 구현하였다.

  • PDF

착용형 단말에서 다수 생체신호의 동시 측정을 가능하게 하는 플러그인 모듈 (The Plug-in Module for Simultaneous Monitoring of Multi Bio-signal in Wearable Devices)

  • 최문식;최동진;강순주
    • 정보과학회 컴퓨팅의 실제 논문지
    • /
    • 제22권4호
    • /
    • pp.195-200
    • /
    • 2016
  • 스마트 워치, 스마트 밴드 같은 웨어러블 디바이스가 개발됨에 따라, 웨어러블 디바이스 사용자의 건강상태를 측정할 수 있는 생체신호 모니터링 기술이 각광 받고 있다[1]. 하지만 한 개의 웨어러블 디바이스에서 여러 가지 생체신호를 측정하기 위해 웨어러블 디바이스에 여러 가지 생체신호 센서를 내장하게 되면 디바이스 자체 크기와 같은 제한적인 자원 측면에서 문제가 발생한다. 또한 새로운 생체신호 센서를 추가 할 때 문제가 발생한다. 본 논문에서는 웨어러블 디바이스 사용자의 요청이 있을 때 가속도 센서, ECG 센서, PPG 센서를 Cradle형태의 모듈에서 동작시킨 후 사용한 센서에서 측정되는 생체 신호를 실시간으로 수집하여 다른 웨어러블 디바이스로 전송할 수 있는 플러그인(Plug-in) 모듈인 Bio-Cradle을 제안한다. Bio-Cradle은 다른 웨어러블 디바이스에 플러그인하면, 디바이스의 종류에 무관하게 동기화 된 다수 생체신호를 전송할 수 있다. 즉 Bio-Cradle을 사용함으로써, 다수 생체신호의 동시 측정이 가능해지고, 웨어러블 디바이스 내부에 생체신호 센서를 내장 할 필요가 없어진다.