• 제목/요약/키워드: Transfer Function Methods

검색결과 364건 처리시간 0.029초

Ladder 회로의 전달함수를 구하는 새로운 방법 (A Novel Method Finding Transfer Function of General Multimesh Ladder Network)

  • 한희;이상배
    • 대한전자공학회논문지
    • /
    • 제17권1호
    • /
    • pp.31-35
    • /
    • 1980
  • 일반적인 ladder회로의 전달함수를 구성하는 각항들 간의 관계로부터 전달함수의 전달함수의 수학적인 공식을 유도하였다. 이 공식의 성질로부터 단계적인 감절법을 개발하엿으며 관찰에 의해서 전달함수를 구할 수 있는 방법을 제시하였다.

  • PDF

Low Work Function and Sharp Field Emitter Arrays by Transfer Mold Fabrication Method

  • Nakamoto, Masayuki;Sato, Genta;Shiratori, Kohji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.1049-1052
    • /
    • 2007
  • Extremely sharp and uniform Transfer Mold FEAs with thin film low work function TiN emitter material have been fabricated by controlling the thickness of the coated emitter materials to realize high efficient, high reliable and low-cost vacuum nanoelectronic devices..Their tip radii are 8.3-13.8 nm. Turn-on electric fields of the Ni FEAs and TiN-FEAs resulted in the low electric field values of $31.6\;V/{\mu}m$ and $44.2V/{\mu}m$,respectively, at the short emitter/anode distance: less than $30\;{\mu}m$, which are lower than those of conventional FE As such as Spindt type FEAs and carbon nan otube FEAs The Transfer Metal Mold fabrication method is one of the best methods of changing emit ter materials with sharp and uniform emit ter shapes.

  • PDF

시간영역 설계명세를 위한 목표전달함수의 새로운 표준형 (New prototypes of target transfer functions for time domain specification)

  • 김신구;김영철
    • 제어로봇시스템학회논문지
    • /
    • 제5권8호
    • /
    • pp.889-897
    • /
    • 1999
  • This paper deals with a problem searching a target transfer function to meet the time-domain specifications for feedback system with given plant transfer function. For the Type I system, we first define three forms of transient response to unit step input, which are named by F, M, S-type. These are charaacterized as follows ; F-type has fast initial response and slow approach to the steady sate after reaching at 90% of the steady state value, S-type has slow initial response but fast approach to the steady state, and M-type is denoted by highly smooth response between F-type and S-type. Three prototypes corresponding to each form are proposed, time. For the order $n{\geq}4$, after determining admissible root structures of target characteristic polynomials empirically and expressing such polynomial coefficients by using special parameters ${\gamma}_i$ and $\epsilon$, the optimal prototypes that minimize the integral of the squared of the modified errors(ISME) have been obtained. Since the step responses of these prototypes have almost same wave forms irrespective to the order, the desired settling time or the rise time can be converted into the equibalent time constant $\tau$ and thus it is easy to obtain a target transfer function. It is shown through a design example that the present prototype is very useful for meeting the time-domain specifications and has been compared with different methods with a viewpoint of pertinence.

  • PDF

A Novel Imaging System for Removal of Underwater Distortion using Code V

  • Maik, Vivek;Daniel, Stella;Chrispin Jiji, A.
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제6권3호
    • /
    • pp.141-150
    • /
    • 2017
  • Images obtained from underwater are usually degraded due to the environmental conditions. Some of the typical degradation factors include turbidity and color degradation. These degradations can be attributed to the absorptive and scattering properties of underwater degradation in terms of optical parameters, such as modulation transfer function (MTF), optical transfer function (OTF),point spread function (PSF), and color constancy. In this paper, we use the CODE V optical simulation software to mimic underwater conditions and model the imaging platform, thereby studying various parameters, such as PSF and MTF, and we use the PSF to remove the underwater turbidity. Experimental results show increased performance with the algorithm, compared to other existing methods.

주파수영역에서 시가지연을 갖는 선형시스템의 모델축소 (A Model Reduction of Linear Systems with Time Delay in Frequency Domain)

  • 김주식;김종근;유정웅
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.176-182
    • /
    • 2004
  • 본 논문에서는 시간지연을 갖는 고차모델을 저차모델로 간소화하기 위한 주파수 전달함수 합성법을 제안한다. 모델축소는 축소시스템의 분자다항식에 의해 가중된 오차함수를 최소화하는 것에 기반을 두고 있다. 제안된 방법은 보다 우수한 저주파수 적합도를 제공한다. 그리고 네 개의 예제가 제안된 방식의 유용성을 나타내기 위해서 주어진다.

복잡한 배경 제거를 통한 치아 X-ray 영상의 선예도 개선 (Sharpness Enhancement of Tooth X-ray Images Through Elimination of Complicated Background)

  • 나건우;류근호
    • Journal of Information Technology Applications and Management
    • /
    • 제30권1호
    • /
    • pp.11-19
    • /
    • 2023
  • To remove unnecessary background from tooth X-ray images and enhance the sharpness of tooth and gum images, image processing techniques including contrast adjustment and histogram equalization are used. The introduction of two methods for detecting the boundary of the tooth and gum region and separating the tooth and gum from the background. In both cases, the background of the tooth X-ray images could be removed as a result, improving the quality of the images. The proposed method improves MTF (Modulation Transfer Function), an image performance indicator, as a result of measuring MTF. The original image's spatial frequency ranged from 4.73 to 11.40 lp/mm at the 10% response, whereas the proposed image's spatial frequency ranged from 10.90 to 11.85 lp/mm, giving uniformly enhanced results. In contrast, tooth and gums could not be completely separated from the background using Apple's Lift subject from background function.

변조전달함수 방법에서 엣지 장치 설정에 대한 각도 최적화 평가 (Evaluation of Angle Optimization on Edge Test Device Setting in Modulation Transfer Function)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권1호
    • /
    • pp.15-21
    • /
    • 2020
  • This study was purpose to evaluation of Modulation Transfer Function in Measurements by using the International electrotechnical commission standard(IEC 62220-1) which were edge device each angle by using edge method. In this study was Aero(Konica, Japan) image receptor which is a indirect Flat panel detector(FPD) was used. The size of matrix 1994 × 2430 (14"× 17" inch) which performed 12 bit processing and pixel pitch is 175 ㎛. The results of shown as MTF measurements at IEC standard. The amount of data seemed reasonable and at an MTF value of 0.1 the spatial frequencies were 2.56 cycles/mm at an angle of 2.4°. MTF value of 0.5 the spatial frequencies were 1.32 cycles/mm at an angle of 2.4°. This study were to evaluate MTF by setting each angle 2.0°~2.8° degrees the most effective optimal edge angle and to suggest the quantitative methods of measuring by using IEC.

Accuracy Enhancement of Reflection Signals in Impact Echo Test

  • Lho, Byeong-Cheol
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.924-929
    • /
    • 2003
  • A majority of infrastructures has been deteriorated over time. Therefore, it is very important to verify the quality of construction, and the level of structural deterioration in existing structures, to ensure their safety and functionality. Many researchers have studied non-destructive testing (NDT) methods to identify structural problems in existing structures. The impact echo technique is one of the widely used NDT techniques. The impact echo technique has several inherent problems, including the difficulties in P-wave velocity evaluation due to inhomogeneous concrete properties, deterioration of evaluation accuracy where multiple reflection boundaries exist, and the influence of the receiver location in evaluating the thickness of the tested structures. Therefore, the objective of this paper is to propose an enhanced impact echo technique that can reduce the aforementioned problems and develop a Virtual Instrument for the application via a thickness evaluation technique which has same technical background to find deterioration in concrete structures. In the proposed impact echo technique, transfer function from dual channel system analysis is used, and coherence is improved to achieve reliable data. Also an averaged signal -ensemble- is used to achieve more reliable results. From the analysis of transfer function, the thickness is effectively identified.

Initial On-Orbit Modulation Transfer Function Performance Analysis for Geostationary Ocean Color Imager

  • Oh, Eun-Song;Kim, Sug-Whan;Cho, Seong-Ick;Ryu, Joo-Hyung;Ahn, Yu-Hwan
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권2호
    • /
    • pp.199-208
    • /
    • 2012
  • The world's first geostationary ocean color imager (GOCI) is a three-mirror anastigmat optical system 140 mm in diameter. Designed for 500 m ground sampling distance, this paper deals with on-orbit modulation transfer function (MTF)measurement and analysis for GOCI. First, the knife-edge and point source methods were applied to the 8th band (865 nm) image measured April 5th, 2011. The target details used are the coastlines of the Korean peninsula and of Japan, and an island 400 meters in diameter. The resulting MTFs are 0.35 and 0.34 for the Korean East Coastline and Japanese West Coastline edge targets, respectively, and 0.38 for the island target. The daily and seasonal MTF variations at the Nyquist frequency were also checked, and the result is $0.32{\pm}0.04$ on average. From these results, we confirm that the GOCI on-orbit MTF performance satisfies the design requirements of 0.32 for 865 nm wavelength.