• 제목/요약/키워드: Transfer Floor

검색결과 204건 처리시간 0.033초

전달함수법을 이용한 장비가진력과 바닥진동응답의 예측 (Prediction of the Exciting Force of Machine and the Vibration Response of Floor Using Transfer Function Method)

  • 김석홍;김준호;이홍기
    • 소음진동
    • /
    • 제2권4호
    • /
    • pp.273-280
    • /
    • 1992
  • The prediction of vibration response of floor is necessary in order to check whether the floor vibration level will satisfy the allowable vibration standard of precise machinery such as electronic microscopes in semiconductor manufacturing plant before the installation of various neighboring equipment facility. In conventional vibration isolation, we were mainly interested in minimization of vibration transmissibility and stabilization of vibration isolation system. But in order to predict vibration response of floor, it is necessary to know exciting force of equipment installed on the floor and the mobility of the floor. We measured the exciting force of the dropped mass assumed as equipment and the mobility of some practical building floor using large impact hammer. And from this we predicted the vibration response of floor on which the mass dropped. This predicted vibration response of floor is compared with measured vibration response. Through upper procedure, we examined the possibility of predicting vibration response of floor from the information of exciting force of equipment and the mobility of floor.

  • PDF

진입과 전이공간 특성에 따른 단독주택 평면류형 변화 연구 - 충주시, 제천시, 원주시 사례를 중심으로 - (Changes of Floor Plans in the Entry and Transfer Spaces of Single Detached Houses - A Case of the City of Chungju, Checheon and Wonju -)

  • 신동규
    • 한국주거학회논문집
    • /
    • 제14권4호
    • /
    • pp.39-48
    • /
    • 2003
  • The purpose of this study was to analyze the changes of floor plans in the entry and transfer spaces of single detached houses. The sample size was 185 households in Chungju, Jechon and Wonju Which are small cities in the central region of Korea. The results of the study are as follows: Firstly, the approach and transfer spaces show various changes and those are important factors which symbolize the housing plane typology transformations of the research areas. Secondly, the approach direction to the indoor space was more adopted a front approach in 1960's and 1970's, it is a side approach in 1980's, and a back side approach in 1990's. Thirdly, as the stage of the transfer space increased, the detached house planes have been changing to the direction, the depth of space comes to be deep, spatial function to be fixed, and privacy of bed rooms to be increased.

흐름 영각에 따른 강제공랭 모듈 주위의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics Around a Surface-Mounted Air-Cooled Module for the Flow Angle-of-Attack)

  • 박상희;신대종
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1267-1275
    • /
    • 2002
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around a module cooled by forced air flow. The flow angle of attack to the module were 0$^{\circ}$and 45$^{\circ}$. In the first method, inlet air flow(1~7m/s) and input power.(3, 5, 7W) were varied after a heated module was placed on an adiabatic floor(320$\times$550$\times$1㎣). An adiabatic wall temperature was determinated to use liquid crystal film. In the second method to determinate heat transfer coefficient, inlet air flow(1~7m/s) and the heat flux of rubber heater(0.031~0.062W/$m^2$) were varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. Additional information is visualized by an oil-film method of the surface flow on the floor and the module. Plots of $T_{ad}$ and $h_{ad}$ show marked effects of flow development from the module and dispersion of thermal wake near the module. Certain key features of the data set obtained by this investigation may serve as a benchmark for thermal-design codes based on CFD.

주상복합건물의 효율적인 지진해석 (Efficient Analysis of Building Structures with a Rigid Floor System)

  • 황현식;이동근
    • 한국지진공학회논문집
    • /
    • 제1권1호
    • /
    • pp.79-88
    • /
    • 1997
  • 주상복합건물의 강체거동을 보이는 연결층은 인접한 층에 비해 큰 질량과 강성차에 의해서 수치해석상의 문제점을 일으킨다. 강체거동을 보이는 구조물의 정적해석은 상부와 하부구조물을 별개의 구조물로 보고 2단계에 걸쳐서 근사적으로 수행될수 있지만, 동적해석은 구조물을 분리해서 행해질 수 없다. 이러한 주상복합건물의 동적해석을 위한 효율적인 모형화기법이 본 연구에서 제시된다. 자유도수를 줄여서 컴퓨터해석시간을 대폭 감소시키는 행렬의 응축기법과 연결층을 모형화하기 위해서 일반적인 보요소에 강체가 연결된 요소를 도입한다. 제안된 모형화기법의 효율성과 정확성을 입증하기 위해서 몇가지 구조해석을 한다.

  • PDF

VIRTUAL CONSTRUCTION OF TRANSFER FLOORS IN REINFORCED CONCRETE BUILDING USING BIM

  • Kwangho So;Bohwan Oh;Yongjik Lee;Hyungeun Lee;Taehun Ha
    • 국제학술발표논문집
    • /
    • The 4th International Conference on Construction Engineering and Project Management Organized by the University of New South Wales
    • /
    • pp.12-16
    • /
    • 2011
  • Building Information Modeling (BIM) is being widely spread in AEC industry worldwide and also in South Korea. Although the creation of digital model is better to be started at design stage, it can also improve the productivity of construction by simulating the actual construction process and environment. This paper presents application of BIM-based simulations related with design changes to transfer floors in 58-storey reinforced concrete office building. Transfer floor is not only a structurally important part of the building but also a challenging part of the actual construction in terms of sequence and period due to the complexity of the work. Preconstruction of rebar, mechanical, and plumbing is performed to review the construction drawings and to perform clash detection. Each item of application is evaluated for its effectiveness on actual construction and for the development potential.

  • PDF

거주자의 거동으로 발생하는 바닥진동의 층간 전달 및 바닥충격음의 음압레벨 특성 평가 (Characteristics of Transmission of Floor Vibration and Floor Impact Noise Due to Human Activities)

  • 이민정;최현기
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.5-13
    • /
    • 2017
  • Noise complaints among neighbors in apartment building are mainly caused by floor impact noise that is structure born noise due to occupant induced floor vibration. To control this noise problems many researchers have investigated floor systems and finishing materials. Light-weight impact noise affects by finishing materials, but heavy-weight impact noise induced by heel impacts during normal walking or jumping of children is concerned with structural system and floor vibration. To figure out the characteristics of floor impact noise and transmission of floor vibration due to human activities, vibration tests were conducted in apartment buildings. Impact hammer, heel drop and walking activities were loaded at center of upstairs living room, and accelerations of slabs for both upstairs and downstairs and sound pressure levels for downstairs were measured. The acceleration ratio of transmitted floor vibration to downstairs and human induced vibration in upstairs was between 0.5 and 1.0 according to slab size, wall, and load type. And floor impact noise occurred in the range of natural frequency of slab.

바닥난방 시스템의 열환경 개선을 위한 제어방안 연구 (A Study on Thermal Heating Control Performance of Automatic Thermostatic Valves in Floor Radiant Heating System)

  • 송재엽;안병천;김경철;장사윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.973-978
    • /
    • 2009
  • In this study, the thermal environment characteristics of On-Off control and thermal difference proportional control method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on two control methods, conventional on-off control and temperature error based time control(T.E.B.T.C.) method, are performed to compare thermal heating control performances, respectively.

  • PDF

바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구 (Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System)

  • 안병천;송재엽;이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

연직 및 횡하중이 작용하는 상부벽식-하부골조구조물의 벽체 배치유형에 따른 거동 해석 (Behavior Analysis According to the Shear Wall Layout of Column-Supported Wall System Subject to Vertical and Lateral Loads)

  • 이대현;김호수
    • 한국공간구조학회논문집
    • /
    • 제4권2호
    • /
    • pp.53-61
    • /
    • 2004
  • 최근 도심지에 건설되고 있는 대부분의 주상복합건물과 아파트들은 다양한 공간을 구성하기 위해 주로 복합구조형식을 채택하고 있다. 특히, 이러한 구조형식들 중의 하나인 상부벽식-하부골조시스템은 전이층에서 서로 연결되는 전단벽형식과 골조형식을 모두 포함하고 있다. 그러나 이 시스템은 구조적인 안전성 측면에서 볼 때 매우 불합리하며, 전이층에서의 응력분포를 파악하기 매우 어렵다. 따라서 본 연구에서는 연직 및 정적 횡하중이 작용하는 전이보 시스템의 전단벽 배치에 따른 구조적인 거동과 응력분포를 분석하고자 함에 있으며, 또한 해석결과를 바탕으로 전이층부근에서의 하중의 전달경로 및 응력집중현상을 파악하고, 전단벽과 전이보의 효율적인 설계를 위한 방안을 제시하고자 한다.

  • PDF