• Title/Summary/Keyword: Transducer 트랜스듀서

Search Result 313, Processing Time 0.018 seconds

Focal Length Control of Line-focus Ultrasonic Transducer Using Bimorph-type Bending Actuator (바이몰프형 밴딩 액츄에이터를 이용한 선집속형 초음파 트랜스듀서의 초점 거리 제어)

  • 채민구;하강열;김무준
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.202-207
    • /
    • 2003
  • For medical ultrasonic transducer, phase-weighting method has been used for controlling focal length with electric circuit at each vibrating element. However, the electric circuit is complex as the number of vibrating elements is increased. In this paper, we fabricated line-focus transducer with a bimorph-type piezoelectric actuator. The polyvinylidene fluoride (PVDF) piezoelectric type polymer film is used for transmitting and receiving of ultrasonic signal. Using this transducer, focal length of the transducer can be controlled mechanically by changing voltage of the actuator. It is confirmed that focal length of the transducer can be controlled in range of 1095 to radius of curvature.

Design of piezoelectric micro-machined ultrasonic transducer for wideband ultasonic radiation in air (공기 중 광대역 초음파 방사용 압전 박막 기반 초소형 초음파 트랜스듀서의 설계)

  • Ahn, Hongmin;Jin, JaeHyeok;Moon, Wonkyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.2
    • /
    • pp.87-97
    • /
    • 2020
  • In this paper, the design of piezoelectric Micro-machined Ultrasonic Transducer (pMUT) for wideband ultrasonic radiation in air was investigated. One of the methods to achieve wide frequency bandwidth in single device is modeling the transducer to multi-resonance system. The new pMUT was designed as a multi-resonance system with the addition of a suitable acoustic structure to the front and back of a thin film structure. A new pMUT consisting of thin film parts, radiation parts, and packaging parts is designed with a Lumped Parameter Model (L.P.M). Finally, it was validated as a Finite Element Method (FEM) simulation. The final designed pMUT achieved a frequency band of 102 kHz ~ 132 kHz (-3 dB).

A Prediction of Radiation Power for the Planar Array Acoustic Transducer Considering Mutual Coupling Effects (상호 간섭 영향을 고려한 평면 배열형 음향 트랜스듀서의 방사 출력 예측)

  • Lee, Jong-Kil;Seo, In-Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.17-22
    • /
    • 1996
  • Planar array of acoustic transducer is normally used in a sonar system. Acoustic radiation makes beam pattern in underwater uses. The main source of the beam pattern is due to the transducer array. Therefore, estimation of the acoustic radiated power is necessary to predict the performance and efficiency of the transducer. As an example of the acoustic radiation power, nine acoustic transducers mounted to a rigid infinite baffle are considered in a theoretical model. Each piston's acoustic radiation consists of self- and mutual-radiation impedances. Total radiation impedances and acoustic radiation power of the transducers are extracted using on the theory of an equivalent electric circuit. The theoretical results reveal that acoustic radiation power of the transducer depends on the mutual coupling effects.

  • PDF

Analysis of the Radiation Pattern in Relation to the Head Mass Shape Applicable to a Tonpilz Transducer (Tonpilz 트랜스듀서에 적용 가능한 전면추 형상에 따른 방사 패턴 해석)

  • Kim, Hoe-Yong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.7
    • /
    • pp.422-430
    • /
    • 2010
  • The radiation property of a Tonpilz transducer is influenced by the structural variables of the transducer. In this study, with respect to a single mode Tonpilz transducer, the radiation patterns were calculated for different head mass geometries of the same effective radiation area. The shapes of the head mass analyzed were the most popular circular, regular triangular, square, regular hexagonal and regular octagonal types, and radiation pattern equations were derived for each of the head mass shapes. Based on the derived equations, radiation patterns in accordance with the shape and size of the head mass were calculated and the results were compared with each other. Validity of the calculation results were confirmed by means of finite element analysis.

Power Supply of Ultrasonic Phased Array for Focus Control of Acoustic Pressure (음압 초점제어를 위한 초음파 위상배열의 전원 장치)

  • Jung, Hyung-Jon;Kim, Ui-Young;You, Bum-Jae;Choy, Ick
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.137-146
    • /
    • 2019
  • The ultrasonic phased arrays are used for treating tumors in the human body by the focus control of the acoustic pressure at the desired position. The magnitude and phase of the surface acoustic pressure in each ultrasonic transducer is controlled by the magnitude and phase of the applied voltage to it. In this paper, the relationship between the applied voltage and the surface acoustic pressure of the ultrasound transducer is modelled, and the desired voltage is realized by PWM technique. The validity of the proposed method is verified by computer simulation of the focus control of a ultrasonic phased array composed of 61 ultrasonic transducers.

Development of an Janus-type Ultrasonic Transducer for Underwater Doppler Log Applications (수중 도플러 로그용 야누스형 초음파 트랜스듀서 개발)

  • 이수성;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.7
    • /
    • pp.77-84
    • /
    • 2000
  • In measurement of ship speed with a Doppler log sensor, we encounter the nonhorizontal movement of a ship, i.e. pitching and rolling, and that causes inaccuracy of the measurement. In this study, we develop a Janus type ultrasonic transducer that can resolve the problems in accuracy due to the pitching and other environmental factors of common ultrasonic sensors attributed to the underwater usage. For the development, we analyze the operation mechanism of the transducer, fabricate a prototype of the sensor, and evaluate its performance through experiments.

  • PDF

Design of Isolation-Type Matching Network for Underwater Acoustic Piezoelectric Transducer Using Chebyshev Filter Function (체비셰프 필터함수를 이용한 수중 음향 압전 트랜스듀서의 절연형 정합회로 설계)

  • Lee, Jeong-Min;Lee, Byung-Hwa;Baek, Kwang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.491-498
    • /
    • 2009
  • This paper presents the design method of an impedance matching network using an isolation transformer and the Chebyshev filter function for the high efficiency and the flat power driving of an underwater acoustic piezoelectric transducer. The proposed impedance matching network is designed for minimizing the reactance component of transducer and having the flat power response in the wide frequency range. We design a low pass filter with ladder-type circuit using the Chebyshev function as standard prototype filter function. In addition, we design the impedance matching network which is suitable for the equivalent circuit of transducer and the turn ratio of transformer through the bandpass frequency transformation. The proposed method is applied to the simulated dummy load of the tonpilz-type transducer operating in the middle frequency range. The simulation results are compared with the measured characteristics and the validity of the proposed method is verified.

A transducer array for focusing the ultrasound setting angle (초음파 집속을 위한 트랜스듀서 어레이 집속 각도 설정)

  • Lee, Sang-sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.1
    • /
    • pp.45-48
    • /
    • 2016
  • The treatment of obesity have been developed various devices for the treatment of obesity, the ultrasound is to be made after the state changes to become easy fat decomposition by heat and vibrations to facilitate the flow of blood and lymph fatty acid released into the blood. There is such ultrasonic transducer array is used in obesity therapy focusing angle of the transducer array and the frequency may have a significant impact on the degradation of fat. In this paper, we set the frequency that reaches the shortest time to a set temperature 27kHz, 1MHz, by applying a transducer with a diameter of 5mm, 10mm, 16mm for the frequency of 3MHz, obtain the wavelength and near the stomach in order to set the frequency of the transducer array, which was set to the focusing angle of the transducer with three contact surfaces. As a result, the time to reach the set temperature was short days when 3MHz frequency, the focusing angle is titrated is $40^{\circ}$.

Design and Fabrication of Multi-mode Wideband Tonpilz Transducers (다중모드 광대역 Tonpilz 트랜스듀서의 설계 및 제작)

  • Kim, Jinwook;Kim, Hoeyong;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.191-198
    • /
    • 2013
  • In this paper, we designed a wideband Tonpilz transducer, and verified the validity of the design through experiments. The wide frequency bandwidth was achieved by coupling the fundamental longitudinal mode of the transducer with a flapping mode of the head mass. Structure of the Tonpilz transducer was optimized by means of the finite element method and genetic algorithm to achieve the widest fractional bandwidth under design constraints. The optimized structure showed a far wider -6 dB fractional bandwidth of transmitting responses than that of single mode transducers. For verification of the design result, we manufactured a transducer prototype of the designed structure and characterized its performance, which showed good agreement with the design results.

Analysis and verification of the characteristic of a compact free-flooded ring transducer made of single crystals (압전단결정을 이용한 소형 free-flooded ring 트랜스듀서의 성능 특성 예측 및 검증)

  • Im, Jongbeom;Yoon, Hongwoo;Kwon, Byungjin;Kim, Kyungseop;Lee, Jeongmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.278-286
    • /
    • 2022
  • In this study, a 33-mode Free-Flooded Ring (FFR) transducer was designed to apply piezoelectric single crystal PIN-PMN-PT, which has high piezoelectric constants and electromechanical coupling coefficient. To ensure low-frequency high transmitting sensitivity characteristics with a small size of FFR transducer, the commercial FFR transducer based on piezoelectric ceramics was compared. To develop the FFR transducer with broadband characteristics, a piezoelectric segmented ring structure inserted with inactive elements was applied. The oil-filled structure was applied to minimize the change of acoustic characteristics of the ring transducer. It was verified that the transmitting voltage response, underwater impedance, and beam pattern matched the finite element numerical simulation results well through an acoustic test. The difference in the transmitting voltage response between the measured and the simulated results is about 1.3 dB in cavity mode and about 0.3 dB in radial mode. The fabricated FFR transducer had a higher transmitting voltage response compared to the commercial transducer, but the diameter was reduced by about 17 %. From this study, it was confirmed that the feasibility of a single crystal-applied FFR transducer with compact size and high-power characteristics. The effectiveness of the performance prediction by simulation was also confirmed.