• Title/Summary/Keyword: Transcatheter closure

Search Result 24, Processing Time 0.03 seconds

The efficacy and safety of transcatheter closure of atrial septal defect with Amplatzer septal occluder in young children less than 3 years of age (3세 미만 심방중격결손 소아에서 Amplatzer 기구 폐쇄술의 안전성 및 효용성)

  • Lee, Soo Hyun;Choi, Deok Young;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.494-498
    • /
    • 2009
  • Purpose : Applicability of transcatheter closure of atrial septal defect (ASD) has been expanded by accumulation of clinical experiences and evolutions of the device. This study was performed to evaluate the safety and efficacy of transcatheter closure of ASD with Amplatzer septal occluder (ASO) in young children less than 3 years of age. Methods : From May 2003 to December 2005, 295 patients underwent transcatheter closure of ASD with ASO in the Severance Cardiovascular Hospital, Yonsei University Health System. Among them, 51 patients less than 3 years of age were enrolled in this study. We investigated procedural success rate, rate of residual shunt, frequency of complications, procedure/fluoroscopy time, and need of modified techniques for device implantation. Results : The median age was 2.1 years and median body weight was 12 kg. Implantation of device was successful in 50 patients (98%). Seven patients (15%) showed a small residual shunt 1 day after the procedure, but complete occlusion had been documented at 6 month follow-up in all patients (100%). The pulmonary to systemic flow ratio (Qp/Qs), peak systolic pulmonary artery pressure, and peak systolic right ventricular pressure had decreased significantly after closure of ASD. There were 2 complications including device embolization (1, 2%) and temporary groin hematoma (1, 2%). Conclusion : Transcatheter closure of ASD with ASO can be performed with satisfactory results and acceptable risk even in young children less than 3 years of age. We could suggest that even in very young children with ASD, there is no need to wait until they grow to a sufficient size for the transcatheter closure.

Complications of transcatheter closure of atrial septal defects using the amplatzer septal occluder (심방 중격 결손의 경피적 폐쇄술 후 발생한 합병증에 관한 연구)

  • Jea, Seo Jin;Kwon, Hyo Jin;Jang, Gi Young;Lee, Jae Young;Kim, Soo Jin;Son, Chang Sung;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.401-408
    • /
    • 2008
  • Purpose : Transcatheter closure of atrial septal defects (ASD) is currently established therapy as an alternative to surgery. But rarely, complications are reported in some studies. We report early and intermediate term complications associated with transcatheter closure of atrial septal defects using the Amplatzer septal occluder (ASO). Methods : From June 2003 to May 2006, 64 patients underwent transcatheter closure of secundum ASD or patent foramen ovale using the ASO. The ratio of male to female was 1:2.4, the median age was 17 years (range: 2.6-64 years) and their median weight was 47.5 kg (range: 2.6-64 kg). Results : The median diameter of ASD measured with transthoracic or transesophageal echocardiography was 15 mm (range: 6-28 mm), the median balloon stretched diameter was 18 mm (range: 6.5-34 mm), and the median size of device was 19.5 mm (range: 6-36 mm), was little difference with balloon stretched diameter. There were 10 cases of complications: arrhythmia (2), device malformation (2), aorta to right atrial fistula (1), hemolytic anemia (1), mitral valve encroachment (1), malposition (1), residual shunt (1), and inferior vena cava perforation (1). Conclusion : Transcatheter closure of ASD using ASO is effective and safe therapy. However, significant complications such as aorta to atrial fistula, atrial erosion, or device embolization can happen, so an appropriate selection of patient and device in relevance to size and anatomy of ASD is important for successful closure.

PDA Clipping by Using 2mm Thoracoscope (2 mm 흉강경을 이용한 동맥관 개존증 폐쇄술 -1례보고-)

  • Moon, Seung-Chul;Yang, Jin-Young;Koo, Won-Mo;Lee, Gun;Lee, Hyeon-Jae;Lim, Chang-Young
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.85-87
    • /
    • 2000
  • Patent ductus arteriosus(PDA) is a common congenital heart disease encountered in premature neonates infants and children. Patent ductus arteriosus was the first surgically managed congenital heart disease,. Classic surgical interruption of patent ducturs arteriosus was partially replaced by a transcatheter endovascular closure, After a 5-7 mm video-assisted thoracoscopic interruption of the patent ductus arteriosus first applied in 1991, this minimally invasive technique came to be used in many centers, Video-assisted thoracoscopic interruption of the patent ductus arteriosus is feasible in low-weight infants whereas transcatheter endovascular closure of the ductus is usually not possible. We experienced successful outcome for the treatment of patent ductus arteriosus with 2 mm video-assisted thoracoscopic titanium clipping, We believed that this technique is a simple safe and rapid method for closure of the patent arteriosus.

  • PDF

Transcatheter Closure of Patent Ductus Arteriosus with a Amplatzer$^{(R)}$ Vascular Plug in Two Dogs (개에서 Amplatzer$^{(R)}$ vascular plug를 이용한 동맥관개존증의 폐쇄 2 증례)

  • Kang, Min-Hee;Kim, Jung-hyun;Moon, So-Jeung;Kim, Seung-gon;Yeo, Jung-Jin;Lee, Chang-Min;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.591-594
    • /
    • 2011
  • A 9-month-old, intact female Maltese dog and one-year-old, intact female beagle dog were presented with continuous heart murmur. These 2 dogs were diagnosed as patent ductus arteriosus (PDA) based on the two-dimensional echocardiography and angiography. Due to the large shunt size, commercially available ductal occlude device was used for transcatheter occlusion of PDA. After Amplatzer$^{(R)}$ vascular plug placement, cardiac murmur was abruptly disappeared in Maltese dog and mildly decreased in beagle dog. Complications and safety after the procedure were evaluated regularly in these 2 dogs. This is first clinical application of Amplatzer$^{(R)}$ vascular plug for transcatheter closure of PDA in two dogs in Korea.

Transcatheter Closure of Patent Ductus Arteriosus with a Coil Embolization in a Dog (개에서 Coil색전술을 이용한 동맥관개존중의 폐쇄 증례)

  • Kang, Min-Hee;Kim, Jung-Hyun;Moon, So-Jeung;Kim, Seung-Gon;Yeo, Jung-Jin;Lee, Chang-Min;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.28 no.2
    • /
    • pp.236-239
    • /
    • 2011
  • A 10 month-old female (intact) Maltese dog was presented due to continuous heart murmur. The dog was diagnosed with patent ductus arteriosus (PDA) based on two-dimensional echocardiography, computed tomography (CT) and angiography. Transarterial coil embolization was used for transcatheter occlusion of the PDA. A single coil was placed successfully and effectively occluded the blood flow through the ductus. Continuous heart murmur disappeared immediately the coil placement and no residual flow was detected. Complications and safety following the procedure were evaluated regularly based on clinical signs, cardiac examinations and serum troponin-I concentrations. This is the first clinical application of coil embolization for transcatheter closure of PDA in a dog in Korea.

Fistula of Ascending Aorta and Right Atrium Following Percutaneous Transcatheter Atrial Septal Defect Closure (경피적 카테타 심방중격결손 폐쇄술 후 발생한 상행 대동맥-우심방루)

  • Um Hong Gook;Seo Hong Joo;Kim Chong Whan;Kim Jun Seok;Lee Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.150-153
    • /
    • 2006
  • Percutaneous transcatheter closure of atrial septal defects as a therapeutic alternative in appropriate patients provides superior cosmetic results, is less invasive, and allows for shorter hospital stays. Unfortunately, however, such percutaneous procedures can be associated with catastrophic procedure complications that may require immediate surgical intervention. We report a case of aorta-to-right atrial fistula two months after transcatheter occlusion of an atrial septal defect by an Amplatzer septal occluder. Revealed by dyspnea, palpitation and hemolysis, this complication needed an emergency surgical operation. The fistula between the noncoronary Valsalva sinus of the aorta and the right atrium was repaired. The atrial septal defect was closed by patch. The cause of this serious complication appears to be erosion into the aorta by the right atrial disk.

A new strategy for transcatheter closure of patent ductus arteriosus with recent-generation devices (경피적 동맥관 폐쇄술에서 최근의 기구들의 전략적 이용과 결과)

  • Kim, Sang Yee;Lee, Soo Hyun;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.488-493
    • /
    • 2009
  • Purpose : The aim of this study was to assess the efficacy and safety of recent-generation patent ductus arteriosus (PDA) closure devices applied by a new selection strategy according to the characteristics of each PDA. Methods : From February 2003 to January 2006, 138 patients underwent transcatheter closure of PDA (study group). According to the size and morphology of each ductus, a COOK Detachable Coil or 'flex' PFM Nit-Occlud was used for a small ductus (group 1, n=43); 'medium' PFM Nit-Occlud (group 2, n=49) for a moderate ductus; and an Amplatzer Duct Occluder (group 3, n=46) for a large ductus. The 83 patients who underwent transcatheter closure of PDA from February 2000 to January 2003 were defined as the comparison group. The Qp/Qs ratio, pulmonary/aorta pressure ratio, and MD of the ductus were compared. Immediate and follow-up results including residual shunts and complications were also evaluated and compared among groups. Results : In all 138 patients, complete occlusions were confirmed without major complications, while procedure failure (n=2, 2.2%), device embolization (n=1, 1.1%), and persistent residual shunt (n=4, 4.5%) were documented in the comparison group. Total complication rates were lower in the study group than in the comparison group (study group, 1.4%; comparison group, 9.0%; P<0.05). Conclusion : A novel strategy adopting the merits of various recent-generation devices for transcatheter closure of PDA provides excellent clinical results with minimal risk.

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.

Closure of patent ductus arteriosus with a vascular plug in a German Shepherd dog

  • Han-Joon Lee;Taehyung Kwon;Gyeonggook Park;Dong-Kwan Lee;Joong-Hyun Song;Kun-Ho Song
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.1
    • /
    • pp.55-59
    • /
    • 2024
  • A 4-year-old, spayed female German Shepherd dog (GSD) weighing 22.4 kg was referred to Chungnam National University Veterinary Medicine Teaching Hospital with the chief complaint of a cardiac murmur. A continuous murmur was detected at the left basilar region upon auscultation. In the thoracic radiographs, slight bulging of the aorta, the main pulmonary artery, and the left atrium were observed. Echocardiography revealed continuous turbulent flow directed from the main pulmonary artery towards the pulmonary valve and consistently within the main pulmonary artery. Based on all the results, a diagnosis of type II A patent ductus arteriosus (PDA) was made, and plans were established to treat it with transcatheter occlusion. Transcatheter occlusion was performed using a vascular plug and successfully deployed at the PDA. The patient did not exhibit any complications. GSDs are relatively less common compared to small-breed dogs in South Korea. Considering that GSDs are predisposed to PDA, it is crucial to periodically assess the presence of PDA through auscultation and echocardiography, even in the absence of clinical signs. Transcatheter occlusion using a vascular plug can be an option for treatment and can yield favorable outcomes.

Patent Ductus Arteriosus Occlusion with an $Amplatz^{(R)}$ Canine Duct Occluder in a Dog (개에서 $Amplatz^{(R)}$ Canine Duct Occluder를 이용한 동맥관개존증의 폐쇄 증례)

  • Kang, Min-Hee;Kim, Seung-Gon;Hahn, Tae-Yeon;Park, Hyun-Ah;Min, Sa-Hee;Park, Ji-Hwan;Kim, Tae-Woo;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.498-501
    • /
    • 2012
  • A 10-month-old intact male Maltese dog (body weight, 1.6 kg) presented with intermittent cough and abnormal heart sounds. The dog was diagnosed with a left-to-right patent ductus arteriosus (PDA) on the basis of the results of transthoracic echocardiography, color flow Doppler examination, and angiography. Transcatheter occlusion of the PDA was performed using the $Amplatz^{(R)}$ Canine Duct Occluder (ACDO) via the femoral artery. The device was placed under fluoroscopic guidance and successfully occluded the PDA. The continuous heart murmur disappeared immediately after the correction and no residual flow was detected. The dog was discharged the following day and regularly examined for complications and safety. This is the first report demonstrating the clinical application of ACDO for the transcatheter closure of PDA via the femoral artery in a small-breed dog in Korea.