• Title/Summary/Keyword: Trans-illumination

Search Result 12, Processing Time 0.032 seconds

EARLY CARIES DETECTION WITH DIGITAL IMAGING FIBER-OPTIC TRANS-ILLUMINATION (Digital Imaging Fiber-Optic Trans-Illumination을 이용한 초기우식의 탐지)

  • Lee, Jun-Seok;Kim, Jong-Soo;Yoo, Seung-Hoon
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.3 no.2
    • /
    • pp.87-90
    • /
    • 2007
  • It's important that detect early caries of deciduous and permanent teeth to prevent dental caries and prevserve teeth, especially on proximal surface of deciduous teeth. The reason is that their prominent pulp horn lead to pulp treatment easily due to rapid caries progression. There are conventional exploring, visual inspection and radiographic exam for early caries detection. But, the standard method for diagnosing dental caries is subject and cavitation may be accelerated during exploring procedure. Caries can be diagnosed up to 40% mineral loss with radiograph. $DIFOTI^{(R)}$ (Digital Imaging Fiber-Optic TransIllumination) is diagnostic imaging system for early caries detection using fiber-optic illumination. It is possible that remineralize the tooth surface without tooth preparation and conserve the tooth structure by using $DIFOTI^{(R)}$.

  • PDF

COMPARATIVE STUDY ON THE EFFICACY OF DIGITAL IMAGING FIBER-OPTIC TRANS-ILLUMINATION AND LASER FLUORESCENCE IN MONITORING THE REMINERALIZATION PROCESS OF INCIPIENT SMOOTH SURFACE ENAMEL LESIONS (Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 평활면 초기우식증의 재광화에 관한 비교 연구)

  • Hwang, Kyu-Seon;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.183-191
    • /
    • 2007
  • Through out the world dental caries seems to be decreased as it is difficult to make an accurate diagnosis for dental caries. The traditional diagnostic method which is probing and x-ray taking has many limitations to diagnose the early caries, so there were recommendations for the needs of new equipments such as laser fluorescence(LF), digital imaging fiber-optic trans-illumination(DIFOTI), and quantitative light fluorescence (QLF) which were developed from various study results. Also confocal laser scanning microscopy(CLSM) and ultrasonics are used for research progression. This study is to evaluate whether it is possible to monitor accurately for remineralization amount of enamel surface early caries using DIFOTI or LF After inducing artificial caries to bovine teeth to 10 participants remineralization was enhanced by 0 ppm and 500 ppm fluoride mouth rinse solution for 3 weeks. Then they were cross sectioned and analyzed using gold standard of the lesion depth measured by CLSM. The following results were obtained: 1. The measured percentage of light intensity(luminosity ratio) by DIFOTI increased with remineralization period, and showed significant reverse correlation with lesion depth measured by CLSM (p<0.01). 2. The measurement of laser fluorescence increased with remineralization period, and showed significant correlation with lesion depth measured by CLSM (p<0.01). 3. To the result for CLSM, 500 ppm fluoride mouth rinse group showed rapid rate for decreased tendency of lesion depth than 0 ppm fluoride mouth rinse group. In conclusion DIFOTI system was used to measure accurately for the remineralization amount of early surface caries, it is a very useful equipment to detect precisely the changes for early enamel caries remineralization during treatments.

  • PDF

DEVELOPMENT OF DIGITAL IMAGING FIBER-OPTIC TRANS-ILLUMINATION SYSTEM (Digital Imaging Fiber-Optic Trans-Illumination System 개발)

  • Lee, Sang-Min;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.199-208
    • /
    • 2009
  • This study was performed to improve the conventional $DIFOTI^{TM}$ system(EOS Inc., USA) by developing the prototype of DIFOTI system which consists of light emitting diode(LED) and digital camera. The images of enamel surfaces treated under Carbopol 907 de-mineralizing solution were taken daily during 7 days of experimental periods by both DIFOTI systems. The results of comparative analyses of obtained images can be summarized as follows: 1. Trans-illumination indices of images taken from sample enamel surfaces were decreased with time in both systems. 2. The difference of intensity of luminance between sound and de-mineralized enamel surface in prototype DIFOTI system was shown to be relatively smaller than conventional $DIFOTI^{TM}$ system. The application of LED light source in prototype DIFOTI system could possibly reduce the amount of current consumption and that could ultimately lead us to the successful development of wireless model with battery. The innovative development of digital camera is undoubtedly expected to create much clearer image despite of wireless transfer. LED and digital camera can be combined into a smaller size but a very important task of improving image manager and analyzing program into a simpler and easier one to manipulate has to be solved.

  • PDF

Synthesis and Characterization of an Organometallic Ruthenium Complex Bearing 4-Picolinic Acid Ligands for Dye-Sensitized Solar Cells (DSSCs) (피콜리닉산 리간드를 갖는 염료감응형 태양전지용 루테늄 염료 합성과 특성분석)

  • Jung, Hye-In;An, Byeong-Kwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.3
    • /
    • pp.192-197
    • /
    • 2016
  • A novel heteroleptic ruthenium(II) complex bearing a 4-picolinic acid unit as anchoring ligands (trans-dithiocyanato bis(4-picolinic acid)ruthenium(II) (trans-H1)) was synthesized and its chemical structure was identified by $^1H$-NMR, FT-IR and mass spectroscopy. The optical, thermal, electrochemical and dye adsorption properties of trans-H1 dye were investigated and compared with those of the gold standard ruthenium complex, Ru(4,4'-dicarboxy-2,2'-bipyridine)$_2cis(NCS)_2$ (N3). DSSCs based on trans-H1 dyes were examined under the illumination of AM 1.5 G, $100mWcm^{-2}$ and exhibited typical photovoltaic properties with an open-circuit voltage ($V_{OC}$) of 0.46 V, a short-circuit current ($J_{SC}$) of $4.10mA{\cdot}cm^{-2}$, a fill factor (FF) of 60.4%, and a conversion efficiency (PCE) of 1.14%.

STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE (Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구)

  • Kim, Jae-Tae;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The purpose of this study were to evaluate the efficacy of the newly developed Digital Imaging Fiber-Optic Trans-illumination (DIFOTI) system in detecting carious lesions in vivo as gold standard with confocal laser scanning microscopy and compared the efficacy of traditional radiography and DIFOTI system in vito as gold standard with confocal laser scanning microscopy, too. For the in vivo study, the subject pool consisted of 23 grammar school age patients just prior to entering the mixed dentition phase Each patient was given a DIFOTI examination of the anterior and posterior teeth. During $6{\sim}8$ months, the naturally expire primary teeth were collected and the efficacy of DIFOTI system was compared with confocal laser scanning microscopy. For in vitro study, 40 primary teeth were collected and decalcified by Carbopol decalcification solution for 1, 2, 4 and 8 days. Every experiment period, all teeth were DIFOTI examined and sectioned to take an image of confocal laser scanning microscopy Sensitivity and specificity were calculated from the result of DIFOTI examine and confocal laser scanning microscopy analysis. The results are as follows : 1. From the in vivo study, the sensitivity of DIFOTI examine was 0. 61 and specificity was 0.63. 2. From the in vivo study, the sensitivity of DIFOTI examine was 0.71 and specificity was 0.75.

  • PDF

Application of Bender Elements in Consolidation, Tomography, and Liquefaction Tests (압밀, 토모그래피, 액상화시험에서 벤더엘리먼트의 적용)

  • Lee, Jong-Sub;Lee, Chang-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.8
    • /
    • pp.43-54
    • /
    • 2006
  • The scope of this paper covers the applications of bender element tests in consolidation, tomography, and liquefaction. Loading and unloading time during consolidation are evaluated based on shear wave velocity. As S-wave velocity is dependent on effective stress, the loading step may be determined. However, cautions are required due to the different mechanism between the settlement and effective stress criteria. The stress history may be evaluated because the S-wave shows the cement controlled regime and stress controlled regimes. A fixed frame complemented with bender elements permits S-wave tomography The tomography system is tested at low confinement within a true triaxial cell. Results show that shear wave velocity tomography permits monitoring changes in the velocity field which is related to the average effective stress. To monitor the liquefaction phenomenon, S-wave trans-illumination is implemented with a high repetition rate to provide detailed information on the evolution of shear stiffness during liquefaction. The evolution of shear wave propagation velocity and attenuation parallel the time-history of excess pore pressure during liquefaction. Applications discussed in this paper show that bender elements can be a very effective tool for the detection of shear waves in the laboratory.

COMPARATIVE STUDY ON THE EARLY DETECTION OF ENAMEL LESIONS USING DIFOTI AND LASER FLUORESCENCE (Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 법랑질 우식증의 조기 진단에 관한 비교 연구)

  • Maeng, Myoung-Ho;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.207-220
    • /
    • 2006
  • The newly developed equipments for the early detection of carious lesion are LFD (laser fluorescence device), Ultrasonic diagnostic system, CLSM(confocal laser scanning microscopy), QLF(quantitative light-induced fluorescence) and DIFOTI (digital imaging fiber-optic trans-illumination) system. In this study, DIFOTI system and LFD were used for the detection of early enamel caries. Twenty five primary teeth extracted from twenty one children at around the dentitional exchanging period were selected as samples. The results obtained from DIFOTI imaging and LFD measurement were compared with those of CLSM and comprehensive evaluations were made for the diagnostic capacity of each device. In vitro test, 40 sample teeth with their buccal & lingual surface formed by a window of $2{\times}3mm$ in diameter were immersed in artificial demineralizing solution for the period of 4, 8, 12 and 16 days. The results obtained from the experimental groups (DIFOTI, LFD) were compared to control group (CLSM) and we have reached to the following conclusions. 1. The sensitivity and specificity of DIFOTI system operated in oral environment was 88.2% and 76.9% respectively. 2. The sensitivity and specificity of LFD measured in oral environment was 76.5% and 69.2% respectively. 3, Regression analysis on the light transparent rate of DIFOTI showed its decrease according to the length of primary enamel decalcification performed in vitro(r=-0.96, p<0.05). 4. No statistically significant difference between LFT measurement and the length of in vitro decalcification was found in regression analysis (p>0.05). 5. The correlation coefficient of DIFOTI image transparent rate and the lesion depth of CLMS was -0.6988 (p<0.05), whereas no statistically significant difference was found for LFD measurement.

  • PDF

A STUDY ON THE OPTIMAL ILLUMINATION POWER OF DIFOTI (DIFOTI 영상 최적화를 위한 광량에 대한 연구)

  • Kim, Jong-Bin;Kim, Jong-Soo;Yoo, Seung-Hoon;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.13-23
    • /
    • 2010
  • This study was performed to compare the quality of image processing between the newly developed prototype using light emitting diode(LED) and the conventional $DIFOTI^{TM}$ system(EOS Inc., USA). To estimate the optimal light emitting power for the improved images, primary enamel surfaces treated under Carbopol 907 de-mineralizing solution were taken daily during 20 days of experimental periods by both DIFOTI systems. The results of comparative analyses on the images obtained from both systems with polarized image as gold standard can be summarized as follows: 1. Trans-illumination indices of images taken from primary enamel surfaces were decreased with time in both systems. 2. The differences of intensity of luminance between sound and de-mineralized enamel surface in prototype DIFOTI system was shown to be relatively smaller than conventional $DIFOTI^{TM}$ system. 3. From the comparative analysis of images from both DIFOTI system with polarized images as gold standard, the difference between sound and de-mineralized enamel surface of intensity of luminance of $DIFOTI^{TM}$ system was more correlated to polarized images than prototype of DIFOTI system. With the optimal LED emitting power, the control of aperture of digital camera is considered as the another key factor to improve the DIFOTI images. For the best image quality and analysis, the development of the improved image processing software is required.

FTIR spectroscopy of the two-photon product of sensory rhodopsin I

  • Sasaki, Jun;Kannaka, Masato;Kandori, Hideki;Tokunaga, Fumio
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.534-536
    • /
    • 2002
  • A halophilic archaeon, Halobacterium salinarum, exhibits phototactic behaviors, by which the organism is guided to red-orange light and evades shorter wavelengths of light. The phototaxis is mediated by two retinal proteins, sensory rhodopsin I and II (SRI and SRII), whose structures are analogous to the cognate protein bacteriorhodopsin, a light-driven proton pump. SRI mediates both attractant and repellent swimming behaviors to orange light and near- UV light, respectively. The two different signaling through the single photoreceptor have been ascribed to the presence of two active structures of SRI (S$\_$373/ and P$\_$520), which are produced upon orange light illumination of SRI and upon subsequent near-UV illumination of S$\_$373/, respectively. In the present study, we have measured the difference FTIR spectra of S$\_$373/ and P$\_$520/ states. In P$\_$520/, the isomeric structure of the chromophore is assignable to all-trans, and the Schiff base of the chromophore is protonated with concomitant deprotonation of Asp76, a combination which allows for the formation of a salt bridge between them. It was suggested that the way of interaction between the Schiff base and the counterion, which is different among SRI$\_$587/, S$\_$373/ and P$\_$520/ and which has been shown to drive the conformational changes in the cognate protein, bacteriorhodopsin, is the key to controlling conformational changes for the attractant and the repellent signaling by SRI.

  • PDF

Automatic detection of tooth cracks in optical coherence tomography images

  • Kim, Jun-Min;Kang, Se-Ryong;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.41-50
    • /
    • 2017
  • Purpose: The aims of the present study were to compare the image quality and visibility of tooth cracks between conventional methods and swept-source optical coherence tomography (SS-OCT) and to develop an automatic detection technique for tooth cracks by SS-OCT imaging. Methods: We evaluated SS-OCT with a near-infrared wavelength centered at 1,310 nm over a spectral bandwidth of 100 nm at a rate of 50 kHz as a new diagnostic tool for the detection of tooth cracks. The reliability of the SS-OCT images was verified by comparing the crack lines with those detected using conventional methods. After performing preprocessing of the obtained SS-OCT images to emphasize cracks, an algorithm was developed and verified to detect tooth cracks automatically. Results: The detection capability of SS-OCT was superior or comparable to that of trans-illumination, which did not discriminate among the cracks according to depth. Other conventional methods for the detection of tooth cracks did not sense initial cracks with a width of less than $100{\mu}m$. However, SS-OCT detected cracks of all sizes, ranging from craze lines to split teeth, and the crack lines were automatically detected in images using the Hough transform. Conclusions: We were able to distinguish structural cracks, craze lines, and split lines in tooth cracks using SS-OCT images, and to automatically detect the position of various cracks in the OCT images. Therefore, the detection capability of SS-OCT images provides a useful diagnostic tool for cracked tooth syndrome.