• Title/Summary/Keyword: Trailing Edge Noise

Search Result 64, Processing Time 0.018 seconds

Gust Response Alleviation of a Three-dimensional Flexible Wing using Sliding Mode Control (슬라이딩 모드 제어기법을 이용한 3차원 유연날개 돌풍응답 제어)

  • Lee, Sang-Wook;Suk, Jinyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.220-225
    • /
    • 2013
  • In this study, active control system using sliding mode control method is presented to achieve the gust response alleviation of a three-dimensional flexible wing model. For this purpose, aeroservoelastic model which is composed of aeroelastic plant, control surface actuator model, and gust model depicting the atmospheric turbulence is formulated in the state space. The aerodynamic force generated by the motion of a trailing edge control surface of a flexible wing is made use of as control means. An active control system combining state feedback sliding mode controller and state estimator based on measured responses such as wing tip acceleration and wing root strain is designed for gust response alleviation of a flexible wing aeroservoelastic model. The performance of the controller designed is demonstrated via numerical simulation for the representative flexible wing model under gust loading conditions.

  • PDF

A Study on the Optimization of Discharge Grille of Outdoor Unit of Air Conditioner (에어컨 실외기 토출그릴 형상 최적화)

  • Choi, Seok-Ho;Oh, Sai-Kee;Kim, Hyun-Jong;Jin, Geun-Ho;Oh, Si-Young;Kim, Byung-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.726-732
    • /
    • 2011
  • The aerodynamic and aeroacoustic performance of discharge grille of outdoor unit of air-conditioner was investigated in this study. Discharge grille is one of outdoor unit's important parts to affect the flow rate and Overall Sound Pressure Level(OSPL). New type of discharge grille was suggested based on the results of numerical simulation. To simulate the flow pattern near the propeller fan, commercial flow solver FLUENT was used. Sliding mesh method was used for rotating propeller fan and initial condition for unsteady model was calculated by Multiple Reference Frame(MRF) method. To minimize the interaction noise between fan blade wake and discharge grille, new discharge grille has radial rib which is aligned with trailing edge of fan blade. And inclined radial rib was adopted for reducing flow rate drop in discharge grille. The optimization of inclined angle of radial grille was performed experimentally.

A Study on the Propeller Blade Singing Place of an 86,000 Ton Deadweight Crude Oil Tanker (86,000톤 원유운반선 프로펠러 날개의 singing(명음) 발생위치 조사)

  • Dong-Hae Kim;Kyoon-Yang Chung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.59-64
    • /
    • 1994
  • A study was conducted to investigate the propeller singing place of an 86, 000 ton Deadweight Crude Oil Tanker. In preliminary study, proper use of finite element analysis was verified by comparing with the result of hammering test in the air. Then the finite element analysis was carried out for the blade in the water and compared with the noise measurement during sea trial, which enabled to confirm the local resonances of blade structure. Result of the study showed that the singing occurred most probably at trailing edges on the blade tip over 95% of propeller diameter. Owing to edge cutting of a successfoul remdial action, the singing excitation forces seemed to be reduced whereas the vibration characteristics of the blade was not changed.

  • PDF

Identification on Fatigue Failure of Impeller at Single Stage Feedwater Pumps During Commissioning Operation (단단 주 급수 펌프 임펠러에서 시운전 중 발생한 피로 절손에 관한 규명 연구)

  • Kim, Yeon-Whan;Kim, Kye-Yean;Bae, Chun-Hee;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.937-942
    • /
    • 2008
  • This paper presents a case history on failures of impeller and shaft due to pressure pulsation at single stage feed water pumps in 700 MW nuclear power plant during commissioning operation. The pumps had been service and had run for approximately $40{\sim}50$ hours. For the most part, the failures of impeller occurred with the presence of a number of fatigue cracks. All cracks were associated with the deleterious surface layer of impeller by visual and metallurgical examination. On-site testing and analytical approach was performed on the systems to diagnose the problem and develop a solution to reduce the effect of exciting sources. A major concern at high-energy centrifugal pump is the pressure pulsation created from trailing edge of the Impeller blade, flow separation and recirculation at centrifugal pumps of partial load. Pressure pulsation due to the interaction generating between impeller and casing coincided with natural frequencies of the impeller and shaft system during 1ow load operation. It was identified that dynamic stress exceeding the fatigue strength of the material at the thin shroud section due to the hydraulic instability at running condition below BEP.