• Title/Summary/Keyword: Traction power supply system

Search Result 97, Processing Time 0.038 seconds

The Computer Algorithm for DC Traction Power Supply System Analysis Including Regenerative Braking Vehicles (회생차량을 포함한 급전시스템 해석 알고리즘)

  • 정상기;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.639-646
    • /
    • 2003
  • Nowadays traction motors in the urban rail transit vehicle are controlled by VVVF inverter and have capability of regenerative braking. The algorithms to deal with the regenerating vehicle in simulation for the DC traction power supply is introduced in this paper. Substations have to be separated from the system to represent reverse biased rectifiers in substations. The model of the trains in regenerative braking has to be changed from the ideal current source to the constant voltage source since the train input voltage has to be controlled below the certain train maximum voltage. Some mismatches are unevitable because the constraint of the regenerated power can not be imposed with the constant voltage source. The mismatches represent the unused regenerated power. A computer program is developed to verify the validity of the algorithm. The test run result shows the program behaves as it is expected and proves the algorithm's validity.

Controllable Harmonic Generating Method for Harmonic Impedance Measurement of Traction Power Supply Systems Based on Phase Shifted PWM

  • Liu, Qiujiang;Wu, Mingli;Li, Jing;Zhang, Junqi
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1140-1153
    • /
    • 2018
  • The harmonic impedance characteristic of a traction power supply system (TPSS) is necessary for taking actions to suppress the high-order harmonic resonances caused by AC electric locomotives. This paper proposes a controllable harmonic generating method (CHGM) for measuring the TPSS harmonic impedance by injecting harmonic disturbances of different frequencies and amplitudes into the TPSS. This method applies phase shifted pulse-width modulation (PSPWM) and ensures that the undesired sideband harmonics can be negligible while the desired harmonic is both controllable and adjustable. Multiple harmonics can be emitted at the same time. The implementation of the method is also presented. Simulations are carried out to validate the performance of the proposed method. Finally, experimental results on a 5 H-bridge converters platform verified the effectiveness and feasibility of the proposed method.

Investigation of Fault Current and Impedance according to Autotransformer Tap Changing (교류급전시스템의 단권변압기 탭변환에 따른 고장전류 및 고장임피던스 검토)

  • Kim, Joo-Rak;Han, Moon-Seob;Chang, Sang-Hoon;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1167_1168
    • /
    • 2009
  • This paper presents new configuration of a.c. traction power supply system. The proposed system includes autotransformer with variable tab. The voltage drop in traction power supply system can be reduced due to tap change of autotransformer. In this paper, fault current and Impedance is investigated, when fault occurs in traction power supply system.

  • PDF

Design of IEC 61850 Logical Nodes for Modeling Protective Elements of Selective-Breaking Integrated Protective Relay for DC Traction Power Supply System (DC 급전계통 선택차단형 통합보호계전기 보호요소 IEC 61850 Logical Node 설계)

  • Yun, Jun-Seok;Kim, In-Woong;Kim, Jin-Ho;An, Tae-Pung;Jung, Ho-Sung;Jung, Tae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.491-496
    • /
    • 2012
  • There are several protective relays used to protect DC traction power supply system for DC railway. These relays, however, are made by different manufactures and they have different ways for their operations. Therefore, there are difficulties for cooperation between the devices or the devices and an upper system. In order to increase interoperability and stability of the system composed of devices made by different manufactures, IEC 61850 international standards are applied to design logical nodes for modeling protective elements used in protective relays.

RESEARCH OF AN ACTIVE FILTER BASED BALANCED POWER SUPPLY SYSTEM FOR RAIL WAY TRACTION

  • Zeng, Guohong;Hao, Rongtai
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.797-801
    • /
    • 1998
  • This paper presents a balanced 3/1 supply scheme for electric railway. By employing an active filter, the current of the three-phrase delivery system is balanced while the load is single phrase, which makes it possible for the traction system to behave like a pure-resistance load, with unity power factor and no harmonics. Simulation results are present to verify the scheme's topology and control strategies.

  • PDF

Test and Analysis of Voltage Drop according to Load Capacity in Traction Power Supply System (전기철도 일형식 부하 크기에 따른 전압강하 측정 및 분석)

  • Kim, Joo-Rak;Jang, Dong-Uk;Chang, Sang-Hoon;Lee, Young-Heum
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.940-947
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

Measurement and Analysis of Voltage Drop in Traction Power Supply System (전기철도 급전시스템의 안정화를 위한 전압강하 측정 결과 분석)

  • Kim, Joo-Rak;Lee, Young-Heum
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2210-2211
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

Reliability Analysis of AC traction System Substation by using Bayes' Theory (베이즈 이론을 이용한 교류전철변전소의 신뢰도 분석)

  • Kim, Yong-Hyun;Koo, Bon-Hui;Cha, Jun-Min;Kim, Hyung-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.445-450
    • /
    • 2008
  • The primary role of traction power systems is to provide reliable and continuous electrical energy to satisfy traction loads. AC traction substation transforms power from generation company and supply the power to the electric railway power line. Forced outage rate(FOR) of the equipment of substation should be used in the evaluation. This paper proposes the fast and easy way to evaluate by using Bayes' theory when a new equipment is added to the existing substation facility.

  • PDF

A Study on DC Traction Power Supply System Using PWM Converter (PWM컨버터를 적용한 경전철 전력공급시스템에 관한 연구)

  • Kim, Joorak;Park, Chang-Reung;Park, Kijun;Kim, Joo-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.250-254
    • /
    • 2016
  • Currently, power conversion system which converts AC to DC Power is applied in domestic urban railway. The diode rectifier is used in most of them. However the diode rectifier can not control the output voltage and can not regenerate power as well. On the other hand, PWM (pulse width modulation) converter using IGBT (isolated gate bipolar transistor) can control output voltage, allowing it to reduce the output voltage drop. Moreover the Bi-directional conduction regenerates power which does not require additional device for power regeneration control. This paper compared the simulation results for the DC power supply system on both the diode rectifier and the PWM converter. Under the same load condition, simulation circuit for each power supply system was constructed with the PSIM (performance simulation and modeling tool) software. The load condition was set according to the resistance value of the currently operating impedance of light rail line, and the line impedance was set according to the distance of each substations. The train was set using a passive resistor. PI (proportional integral) controller was applied to regulate the output voltage. PSIM simulation was conducted to verify that the PWM Converter was more efficient than the diode rectifier in DC Traction power supply system.

Computer Algorithm for the Loadflow of the DC Traction Power Supply System (도시철도의 DC급전시스템 해석 알고리즘)

  • 정상기;홍재승
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.78-85
    • /
    • 2000
  • Computer algorithms for the loadflow of the DC traction power supply system are examined. Algorithms to solve the nodal equation are reviewed and the two iterative methods to solve the nonlinear nature of the loadflow are analyzed and tested, which are so called conductance matrix method and current vector iterative mettled. The result of the analysis tells that the current vector iterative method makes faster convergency and needs less computing time, and it is verified by the test running of the programs based on each of the iterative methods.

  • PDF