• Title/Summary/Keyword: Tracker Device

Search Result 37, Processing Time 0.018 seconds

WOI : Determining Area of Interest and Gaze Analysis for Task Switching in a Window Unit Behavior Measurement in Windowing System GUI (WOI : 윈도윙 시스템 GUI에서의 창 단위 작업 전환 행위 측정을 위한 관심영역 지정 및 시선 분석)

  • Ko, Eunji;Choi, Sun-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.5
    • /
    • pp.963-971
    • /
    • 2016
  • This paper is a research of gaze analysis for measuring task switching behavior at multiple windows in GUI of windowing system. Previous methods that define area of interest for categorizing gaze had difficulties to define dynamic content that disappears or changes over time. On the other hand, this study suggests a new method to categorize gaze that defines Area of interest in a unit of window during the eye tracking experiment. In this paper, we constructed the conception of WOI(Window of Interest) in GUI of windowing system. Therefore, we developed a system using an eye tracker device and implemented a number of experiments. In addition, we analyzed the number of task switching and proportion of watched content. The method in the study comprehend from previous researches as it can measure and analyze the multi-tasking behaviors using multiple numbers of windows.

A Study on Long Range Image Monitoring and Tracking System Using Laser Range-Gate Method in Inclement Weather Conditions (악천후 상황에서 Laser Range-Gate 방식을 이용한 원거리 영상 감시 및 추적 시스템에 대한 연구)

  • Oh, Sung-Kwun;Yoo, Sung-Hoon;Ku, Kyong-Wan;Kim, Su-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.257-263
    • /
    • 2013
  • In case of image observation equipments, CCTV for short distance visual field is usually installed and operated mostly as the means of crime-prevention. However, the extensive demand for monitoring problems in case of the increase in intelligent crimes and disasters has led to the necessity of the development of long-distance observation equipments embedded with Night View functions. In case of the Night View equipments, the relevant market is set up to be focused mostly on Thermal Observation Device(hereinafter, TOD), but some shortcomings such as the limitation of image visibility and excessive maintenance cost, etc. have actually caused the necessity of new long distance Night View equipment. Moreover there might follow lots of difficulties in long-distance visualization in the event that irregular reflection is generated by minute particles in the atmosphere such as fog, smog, and dust, etc. These factors are motivate the work presented in this study. Our study is aimed at the realization of Pulsed Laser Illuminator and newly proposed Range-Gated image acquisition technology. And also the implementation of Tracker for continuous trace of the objects of interest from the obtained sequence images.

The Design of Content using IR-Tracking System in the Spatial Virtual Reality Metaverse (공간 가상현실 메타버스내에서 IR-트래킹 시스템을 이용한 컨텐츠 설계)

  • Tae-Won Kim;Sang-Yoon Lee;Hyun-Woong Kim;Dae-Sol Lee;Dae-Sik Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.247-255
    • /
    • 2023
  • In order to create a virtual reality space in the metaverse, accurate tracking sensors and implementation are required. Most government agencies and corporations performs tracking to use their own tracking sensors and a base stations, such as VIVE. The VIVE method may have tracking problems due to spatial constraints and obstacles or nearby structures, and it is also that the number of people that can be accommodated within the space is also limited. In this paper, we designed and implemented metaverse using an IR sensor tracking system to freely track the spatial virtual reality metaverse, and we experimented contents in metaverse by placing IR sensors additionally on the floor and ceiling if needed in order to flexibly configure the metaverse space. As a result of the experiment, the tracking stability of the IR-tracking system was approximately 12% higher than the VIVE method. Additionally, adding more tracking sensors on the floor increases tracking stability and allows for a stable representation of virtual space.

A Study on Controlling IPTV Interface Based on Tracking of Face and Eye Positions (얼굴 및 눈 위치 추적을 통한 IPTV 화면 인터페이스 제어에 관한 연구)

  • Lee, Won-Oh;Lee, Eui-Chul;Park, Kang-Ryoung;Lee, Hee-Kyung;Park, Min-Sik;Lee, Han-Kyu;Hong, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.6B
    • /
    • pp.930-939
    • /
    • 2010
  • Recently, many researches for making more comfortable input device based on gaze detection have been vigorously performed in human computer interaction. However, these previous researches are difficult to be used in IPTV environment because these methods need additional wearing devices or do not work at a distance. To overcome these problems, we propose a new way of controlling IPTV interface by using a detected face and eye positions in single static camera. And although face or eyes are not detected successfully by using Adaboost algorithm, we can control IPTV interface by using motion vectors calculated by pyramidal KLT (Kanade-Lucas-Tomasi) feature tracker. These are two novelties of our research compared to previous works. This research has following advantages. Different from previous research, the proposed method can be used at a distance about 2m. Since the proposed method does not require a user to wear additional equipments, there is no limitation of face movement and it has high convenience. Experimental results showed that the proposed method could be operated at real-time speed of 15 frames per second. Wd confirmed that the previous input device could be sufficiently replaced by the proposed method.

A Study on the Performance Improvement of Bar Code Reader for the Automatic Processing of the Mail Items (우편물 자동처리를 위한 바코드 판독기 성능개선에 관한 연구)

  • Park, Moon-Sung;Nam, Yun-Seok;Kim, Hey-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.04b
    • /
    • pp.731-734
    • /
    • 2001
  • 우편물을 집배원이 배달하는 순서로 자동구분 처리하기 위한 요소기술 줌에서 4-state 바코드 시스템이 개발되고 있으며 우편번호, 배달순서코드, 고객정보 등이 적용될 예정이다. 기존의 고객 바코드 판독 시스템은 우편물상의 바코드 심볼로지가 존재하는 판독대상 영역의 기울기가 ${\pm}4.47^{\circ}$ 이하이고, 심볼의 훼손과 잡영이 없을 경우에 $79{\sim}100msec(35,000{\sim}45,000$통/시간)의 속도로 자동 구분 정보가 판독된다. 본 논문에서는 판독범위 및 판독성능을 개선을 위하여 CCD(Charge Coupled Device) 센서로부터 획득된 이미지상에서 존재하는 심볼로지 정보의 고속판독 방법을 제시한 것이다. 이 판독방법은 그레이(gray) 이미지 바탕면의 경계값(threshold) 기울기 분포를 기준으로 2개의 경계값을 설정하여 판독대상 정보를 획득하였다. 또한, 4-state 바코드 심볼로지의 존재 가능성 영역만을 탐색하고, 판독대상 영역에서 트래커(tracker)를 탐색하여 심볼로지의 기울기값, 심볼로지 경계값, 심볼위치 좌표값을 생성한 후 심볼값이 판독한 것이다. 판독시험 결과는 판독대상 영역의 심볼로지가 ${\pm}45^{\circ}$ 기울어지고, 잡영이 존재할 경우에도 $30{\sim}60msec(58,000{\sim}l16,000$통/시간) 이내에 판독되었다. 우편물 자동구분용 바코드 판독기로써 적용될 경우에 판독속도가 평균 57.25% 이상 개선되고, 판독범위의 확장으로 0.2%의 기계적인 오류(이송과정예서의 Jam 발생 비율)를 제외할 경우에 거의 99.8% 우편물을 판독하여 자동구분 처리할 수 있게 될 것으로 기대된다.onebook 엑세스 모들(Server Phonebook Access Module)로 구성되어 있다.외 보다 높았다(I/O ratio 2.5). BTEX의 상대적 함량도 실내가 실외보다 높아 실내에도 발생원이 있음을 암시하고 있다. 자료 분석결과 유치원 실내의 벤젠은 실외로부터 유입되고 있었고, 톨루엔, 에틸벤젠, 크실렌은 실외뿐 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되었다. 답이 없는 문제, 문제 만

  • PDF

A Study on the Method of High-Speed Reading of Postal 4-state Bar Code for Supporting Automatic Processing (우편용 4-state 바코드 고속판독 방법에 관한 연구)

  • Park, Moon-Sung;Kim, Hye-Kyu;Jung, Hoe-Kyung
    • The KIPS Transactions:PartD
    • /
    • v.8D no.3
    • /
    • pp.285-294
    • /
    • 2001
  • Recently many efforts on the development of automatic processing system for delivery sequency sorting have been performed in ETRI, which requires the use of postal 4-state bar code system to encode delivery points. This paper addresses the issue on the extension of read range and the improvement of image processing method. For the improvement of image processing procedure, applied information acquisition method through basic two thresholds onto the horizontal axial line of gray image based on reference information of 4-state bar code symbology. Symbol values are computed after creating two threshold values based on the obtained information through search of horizontal axial values. The implementation result of 4-state bar code reader are obtained the symbol values within 30~60 msec (58,000~116,000 mail item/hour)without noise removal or image rotation in spite of the incline $\pm 45^{\circ}$.

  • PDF

Smartphone vs Wearable, Finding the Correction Factor for the Actual Step Count - Based on the In-situ User Behavior of the Two Devices - (스마트폰 vs 웨어러블, 실제 걸음 수 산출을 위한 보정계수의 발견 - 두 기기의 In-situ 활용 행태 비교를 바탕으로 -)

  • Han, Sang Kyu;Kim, Yoo Jung;An, A Ju;Heo, Eun Young;Kim, Jeong Whun;Lee, Joong Seek
    • Design Convergence Study
    • /
    • v.16 no.6
    • /
    • pp.123-135
    • /
    • 2017
  • In recent mobile health care service, health management using number of steps is becoming popular. In addition, a variety of activity trackers have made it possible to measure the number of steps more accurately and easily. Nevertheless, the activity tracker is not popularized, and it is a trend to use the pedometer sensor of the smartphone as an alternative. In this study, we tried to find out how much the number of steps collected by the smartphone versus the actual number of steps in actual situations, and what factors make the difference. We conducted an experiment to collect number of steps data of 21 people using the smartphone and wearable device simultaneously for 7 days. As a result, we found that the average number of steps of the smartphone is 62% compared to the actual number of steps, and that there is a large variation among users. We derived a regression model in which the accuracy of smartphone increases with the degree of awareness of smartphone. We expect that this can be used as a factor to correct the difference from the actual number of steps in the smartphone alone healthcare service.