• Title/Summary/Keyword: Tracer-test

Search Result 183, Processing Time 0.026 seconds

Examining the Equality of Multi-Outlet Flow Rates within a Dual Open Channel (이중 수로 구조의 분배수로 내 다지점 유출 유량의 균등성 평가에 관한 연구)

  • Kim, Seong-Su;Park, No-Suk;Jeong, Woo-Chang;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.423-430
    • /
    • 2012
  • This study was conducted to qualify the equality of the flow distribution from open channel between rapid mixing basin and flocculation basins in a domestic S_ water treatment plant, and to suggest a remedy for improving the equality. In order to evaluate the feasibility of the suggested remedy, computational fluid dynamics (CFD) technique are used, and for verifying the CFD simulation results tracer tests were carried out. From the results of CFD simulation and tracer tests, it was investigated that the modification of hydraulic structure in the distribution channel, which is to install the longitudinal orifice baffle in flow direction, could improve the equality of the flow distribution over 75%.

Study on Methodology for Reducing Dead Zone Flow within Chlorine Contactor Installing Porous Baffles (유공벽을 이용한 우류식 염소접촉조 사류 저감 방안 연구)

  • Park, Hyun-Ho;Park, No-Suk;Cha, Min-Whan;Kim, Sa-Dong;Won, Chan-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.519-525
    • /
    • 2010
  • From the results of tracer test for the existing chlorine contactor in Y water treatment plant, $T_{10}$ and $T_{10}$/T were calculated as 130 min and 0.16, respectively. Therefore it required the modification schemes for improving hydraulic efficiency, surrogated by T10 and $T_{10}$/T, and disinfection performance. In this study, in order to reduce dead zone within contactor, the installation of porous baffles in the near of each corner was suggested and verified using transient CFD(Computational Fluid Dynamics) simulation technique and tracer tests on dynamic condition. From the results of simulation and tracer tests, it was revealed that porous baffles installed have been effective to reduce dead zone within contactor, and increase plug flow fraction.

Characterization of the Transport of Zero-Valent Iron Nanoparticles in an Aquifer for Application of Reactive Zone Technology (반응존 공법 적용을 위한 나노영가철의 대수층 내 이동 특성에 관한 연구)

  • Kim, Cheolyong;Ahn, Jun-Young;Ngoc, Tuan Huynh;Kim, Hong-Seok;Jun, Seong-Chun;Hwang, Inseong
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.3
    • /
    • pp.109-118
    • /
    • 2013
  • Characteristics of the transport of zero-valent iron nanoparticles (nZVI) in an aquifer were investigated to evaluate an application of nZVI-based reactive zone technology. Main flow direction of groundwater was north. Preferential flow paths of the groundwater identified by natural gradient tracer test were shown northeast and northwest. The highest groundwater velocity was $4.86{\times}10^{-5}$ m/s toward northwest. When the breakthrough curves obtained from the gravity injection of nZVI were compared with the tracer curves, the transport of nZVI was retarded and retardation factors were 1.17 and 1.34 at monitoring wells located on the northeast and northwest, respectively. The ratios of the amount of nZVI delivered to the amount of tracer delivered at the two wells mentioned above were 24 and 28 times greater than that of the well on the main flow direction, respectively. Attachment efficiency based on a filtration theory was $4.08{\times}10^{-2}$ along the northwest direction that was the main migration route of nZVI. Our results, compared to attachment efficiencies obtained in other studies, demonstrate that the mobility of nZVI was higher than that of results reported in previous studies, regardless of large iron particle sizes of the current study. Based on distribution of nZVI estimated by the attachment efficiency, it was found that nZVI present within 1.05 m from injection well could remove 99% of TCE within 6 months.

Infiltration Characteristics of Tracer Wetting Front through Effective Pores of Unsaturated Soil (불포화토 유효공극 내 추적자 침윤선 거동 특성 평가)

  • Kim, Man-Il;Nishigaki, Makoto
    • The Journal of Engineering Geology
    • /
    • v.17 no.1 s.50
    • /
    • pp.41-47
    • /
    • 2007
  • Geotechnical Phenomena such as landslide, groundwater recharge and groundwater fluctuation due to rainfall can be explain to use a dielectric response and infiltration variation by the movement of a wetting front in the subsurface. The infiltration of a wetting front is infiltrating to the connected pores which are distributed in unsaturated soil. In this study we carried out to laboratory experiment of a vertical infiltration column test using ethanol mix-ing tracer which has same the specific gravity of water. All physical values are detected to use a variation of dielectric constant and calculated to use a dielectric mixing model and tracer test model. This dielectric method measured by each dielectric constant of geological soil porous materials should be of for the geotechnical information and useful a field monitoring technique for detecting the variations of the volumetric water content and the wetting front, which are insignificant the key parameter to understanding the landslide by rainfall.

Tracer Tests on Transverse Mixing in Meandering Streams (사행하천에서 횡혼합에 관한 추적자 실험)

  • Seo, Il-Won;Baek, Kyung-Oh;Jeon, Tae-Myoung;Jin, Joo-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.4
    • /
    • pp.673-689
    • /
    • 2003
  • Field tests were conducted to investigate characteristics of the transverse mixing and to evaluate the dispersion coefficients in the meandering natural streams. The Sum River and the Cheong-mi Creek, tributaries of Han River, were selected as the test site, and measurements of the hydraulic and dispersion data were performed. In the tracer tests, the radioisotope was used as a tracer and injected into a flow on the instantaneous point source. Using the measured data, the longitudinal and transverse dispersion coefficients were evaluated and compared with the previous studies. The longitudinal dispersion coefficients, which were evaluated by application of the analytical solution, were about 0.5 $m^2$/s at the Sum River and 0.2 $m^2$/s at the Cheong -mi Creek. The transverse dispersion coefficients, which were evaluated by the analytical solution and the moment method, were ranging from 0.01 to 0.06 $m^2$/s for the Sum River and from 0.01 to 0.05 $m^2$/s for the Cheong-mi Creek.

Tracer Experiment for the Investigation of Urban Scale Dispersion of Air Pollutants - An Improved Method for the Release and Determination of Perfluorocarbon Tracers in the Urban Atmosphere (추적자 확산 실험에 의한 서울 도심 확산 현상 연구 - 도시규모 대기확산 실험을 위한 PFCs 추적자 방출 및 분석 시스템의 개발 및 적용 연구)

  • Yoo, Eun-Jin;Lee, Chong-Bum;Ro, Chul-Un;Kim, Hye-Kyeong;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.547-556
    • /
    • 2007
  • The release, sampling and analytical methods have been developed and tested for perfluorocarbons (PFCs) atmospheric tracers in order to gain insight into the atmospheric transport and dispersion over the urban conditions of Seoul, Korea. Although PFCs tracer experiments provide unique opportunities to test local and urban scale of transport and dispersion, no previous experiment with PFCs has been conducted in Korea. PMCH and PDCH were chosen as targeted tracers in our study due to their extreme low ambient concentrations and great sensitivities among various PFCs. For PFCs release system, a set of micro-metering pump, electronic balance, vaporizing furnace and high speed blower was constructed for precise and accurate release of tracers. The precision of released rate by this system was estimated to be 1%. Samplings of PFCs were carried out by fabricated portable air samplers with micro pumps and rotameters into glass tubes packed with 150 mg of Carboxen-569. The uncertainty of these sampling system was maintained below 14%. PMCH and PDCH were quantified in GC/ECD with preconditioned injection system to eliminate the interference compounds using traps and subsequent catalytic conversion system prior to column separation. Three intensive field test were undertaken during the springtime of 2002 to 2004 in eastern part of Seoul. Daily background samples were collected to characterize the background levels of PMCH and PDCH prior to their release. The observed background concentrations of PMCH ranged from 3.5 to 10.1 fL/L and varied randomly in location and time in this study. Its mean and standard variation of background concentration ($6.8{\pm}1.9\;fL/L$) are higher than those ($3.2{\sim}5.8\;fL/L$) of other historic tracer studies. Identified uncertainty for background PMCH was $1.7{\sim}2.0\;fL/L$ using this analytical system. Combined relative uncertainty in determining the tracer's concentrations was estimated as 17%. However, its background concentrations and uncertainty in concentration determination were found to be low and stable enough for tracer study.

Jansen Mechanism을 기반으로 한 보행로봇의 최적화와 Line tracer

  • Do, Seung-Hun;Choe, Ju-Yeong;Kim, Min-Su;Park, Hyeon-Su;Kim, Dong-Hwi;Lee, Chun-Yeol
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.506-510
    • /
    • 2017
  • Based on the Jansen mechanism theory, a walking robot is developed, which is able to trace a line. In order to find the optimized legs, GL(Ground Length), GAC(Ground Angle Coefficient) and Grashof criteria are utilized in m.sketch program as well as EdisonDesign program. Many types of design are applied to sensors and controls, and the functionality is checked. Finally, a prototype line tracer robot is manufactured using aduino parts and smart boards. The prototype robot is test run to check the validity of the design, and modifications are applied to improve the performance according to each test result until the best design is achieved.

  • PDF

A Clinical Study on the Development of a Simplified Fat Absorption Test by Simultaneous Administration of $^{125}I$-triolein and Chromic Oxide($^{51}Cr_2O_3$) ($^{125}I-triolein$$^{51}Cr_2O_3$의 동시투여(同時投與)에 의(依)한 지방흡수시험법(脂肪吸收試驗法)의 개발(開發)에 관(關)한 임상연구(臨床硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Hong, Chang-Gi;Kim, Byung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.33-39
    • /
    • 1969
  • The conventional triolen absorption test has its defect in that the stool collection was cumbersome, time and energy-wasting. In the present study, the triolen absorption test was carried out using double tracer technique with $^{125}I-triolen\;and\;^{51}Cr_2O_3$ to determine if it can overcome the defect of the conventional method also with satisfactory results. Following were the results: 1. The clinical significance of this double tracer method was essentially the same with that previously done by radioactive. triolen alone. With the fractional fecal samples, the equation, y=0.626x+2.010 was substantiated, hence, this method appears to be clinically valuable if the appropriate correction is applied. With the mixed fecal samples, the equation y=0.642x+1.468 was substantiated (p<0.005) which appears to be also clinically valuable. When these two data were compared, the equation y=0.975x+0.090 (P<0.05) was substantiated, hence, $x{\fallingdotseq}y$. 2. The normal ranges of the fecal triolen excretion rate in this double tracer method were $3.46{\pm}1.69%$, namely, less than 6.9%. 3. The samplings were done from the first to third defecation in cases of clinically normal, and from the first to second defecation in cases of diarrhea or malabsorption. 4. The intestinal malabsorption of triolen was not observed in whom the triolen absorption was supposed to be clinically normal, however. a good number of suspicious malabsorptive cases showed the normal values.

  • PDF

Performance Evaluation of Close Waste Landfill Vertical Slurry Wall(SCW) by Tracer Method (추적자조사기법을 활용한 사용종료매립장 연직차수벽 성능평가)

  • Lee, Dong-Geon;Oh, Young-In;Kim, Kwan-Ho;Cho, Sook-Hee;Bak, Eun-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1245-1252
    • /
    • 2010
  • Many industrialized countries are confronted with a difficulty about reuse of closed waste landfill. facilities. Especially, the demand of closed waste landfill maintenance and reuse nearby urban area has been increased, because of the shortage of usable land and extend of urban area. For the safe reuse of closed waste landfill, the most important check point is the effect of waste landfill on environment abound them. However, the non-sanitary closed waste landfill generally have no leachate lining system, therefore, the in-situ lining system such as sheet-pile, and vertical slurry wall etc. was needed to prevent the leachate outgoing from the waste landfill. In this paper present the case history of performance evaluation of vertical slurry wall by tracer tests.

  • PDF