• Title/Summary/Keyword: Tracer Test

Search Result 183, Processing Time 0.025 seconds

Comparison of the replicability of centric relation registration techniques using Arcus Digma (Arcus Digma를 이용한 하악 중심위 유도방법에 따른 하악위의 재현성에 관한 비교 연구)

  • Lim, Hyun-Pil;Cho, Young-Eun;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.201-210
    • /
    • 2009
  • The purpose of this study was to compare the replicability of centric relation made by means of self guided method, bimanual manipulation, chin-point guidance, leaf gauge method, gothic arch tracing. The EPA test of Arcus $Digma^{(R)}$ was employed for examining the reproducibility of centric relation. 10 adults with normal occlusion were participated in this study. In this limitation of study, the following results were obtained; Condyle position was different depending on different methods of guiding centric relation. Left and right temporomandibular joints showed a little different degree of repeatability. Bimanual manipulation using anterior jig was the most replicable. Chin point guidance provided the second most repeatable method, and Gothic arch tracing showed the third, the leaf gauge was the forth, the self-guided method was the worst.

Analysis of the applicability of parameter estimation methods for a transient storage model (저장대모형의 매개변수 산정을 위한 최적화 기법의 적합성 분석)

  • Noh, Hyoseob;Baek, Donghae;Seo, Il Won
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.681-695
    • /
    • 2019
  • A Transient Storage Model (TSM) is one of the most widely used model accounting for complex solute transport in natural river to understanding natural river properties with four TSM key parameters. The TSM parameters are estimated via inverse modeling. Parameter estimation of the TSM is carried out by solving optimization problem about finding best fitted simulation curve with measured curve obtained from tracer test. Several studies have reported uncertainty in parameter estimation from non-convexity of the problem. In this study, we assessed best combination of optimization method and objective function for TSM parameter estimation using Cheong-mi Creek tracer test data. In order to find best optimization setting guaranteeing convergence and speed, Evolutionary Algorithm (EA) based global optimization methods, such as CCE of SCE-UA and MCCE of SP-UCI, and error based objective functions were compared, using Shuffled Complex-Self Adaptive Hybrid EvoLution (SC-SAHEL). Overall results showed that multi-EA SC-SAHEL with Percent Mean Squared Error (PMSE) objective function is the best optimization setting which is fastest and stable method in convergence.

Analysis of solute transport in rivers using a stochastic storage model (확률론적 저장대모형을 이용한 하천에서의 물질혼합거동 해석)

  • Kim, Byunguk;Seo, Il Won;Kwon, Siyoon;Jung, Sung Hyun;Yun, Se Hun
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.5
    • /
    • pp.335-345
    • /
    • 2021
  • The one-dimensional solute transport models have been developed for recent decades to predict behavior and fate of solutes in rivers. Transient storage model (TSM) is the most popular model because of its simple conceptualization to consider the complexity of natural rivers. However, the TSM is highly dependent on its parameters which cannot be directly measured. In addition, the TSM interprets the late-time behavior of concentration curves in the shape of an exponential function, which has been evaluated as not suitable for actual solute behavior in natural rivers. In this study, we suggested a stochastic approach to the solute transport analysis. We delineated the model development and model application to a natural river, and compared the results of the proposed model to those of the TSM. To validate the proposed model, a tracer test was carried out in the 4.85 km reach of Gam Creek, one of the first-order tributaries of Nakdong River, South Korea. As a result of comparing the power-law slope of the tail of breakthrough curves, the simulation results from the stochastic storage model yielded the average error rate of 0.24, which is more accurate than the 14.03 and 1.87 from advection-dispersion model and TSM, respectively. This study demonstrated the appropriateness of the power-law residence time distribution to the hyporheic zone of the Gam Creek.

현장 Single Well Push-Pull 실험을 통한 탈질산화반응 각 단계의 반응속도 측정

  • Yeong, Kim;Jin Hun, Kim;Bong Ho, Son;Seong Uk, Eo
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.77-82
    • /
    • 2004
  • Quantifying rates of microbial processes under subsurface conditions is difficult, and is most commonly approximated by laboratory studies using aquifer materials. In this study a single-well, 'push-pull' test method is adapted for the in situ determination of denitrification rates in groundwater aquifers. The rates of stepwise reduction of nitrate to nitrite, nitrous oxide, and molecular nitrogen were determined by performing a series of push-pull tests at an experimental well field of Korea University. A single Transport Test, one Biostimulation Test, and four Activity Tests were conducted for this study. Transport tests are conducted to evaluate the mobility of solutes used in subsequent tests. These included bromide (a conservative tracer), fumarate (a carbon and/or source), and nitrate (an electron acceptor). At this site, extraction phase breakthrough curves for all solutes were similar, indicating apparent conservative transport of the solutes prior to biostimulation. Biostimulation tests were conducted to stimulate the activity of indigenous heterotrophic denitrifyinc microorganisms. Biostimulation was detected by the simultaneous production of carbon dioxide and nitrite after each injection. Activity tests were conducted to quantify rates of nitrate, nitrite, and nitrous oxide reduction. Estimated zero-order degradation rates decreased in the order nitrate '||'&'||'gt; nitrite '||'&'||'gt; nitrous oxide. The series of push-pull tests developed and field tested in this study should prove useful for conducting rapid, low-cost feasibi1ity assessments for in situ denitrification in nitrate-contaminated aquifers.

  • PDF

Consolidation Settlement of Capped Sediment (II): Advective Transport of Pore Water and Analytical Prediction of Settlement (캡이 설치된 퇴적층의 압밀 침하 (II): 간극수의 이동 및 침하의 해석적 예측)

  • Kim, Tae-Hyung;Hong, Won-Pyo;Moo-Young, Horace-K
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.3
    • /
    • pp.39-44
    • /
    • 2003
  • Centrifuge test was conducted to simulate the effects of consolidation settlement of capped contaminated marine sediment. A fluorescent dye was used to monitor the movement of pore water through the cap layer. Dye tracer study clearly showed the consolidation induced advective transport of contaminants. Thus, the capping layer must be appropriately designed to reduce the effects of consolidation induced advective transport. The results from the centrifuge test were compared to predictions made by the Primary consolidation, Secondary compression, and Desiccation of Dredged Fill (PSDDF) computer program, which can qualitatively estimate the consolidation settlement of capped marine sediment. Although PSDDF approximated closely the secondary compression in the centrifuge test (i.e., compare data points from 18 to 25 prototype years), the maximum deviation between centrifuge test result and PSDDF prediction was 20 % about prototype time 6 years. Thus, designers should utilize PSDDF consolidation settlement results with caution.

Assessment of chemical purity of [13N]ammonia injection: Identification of aluminium ion concentration

  • Kim, Ho Young;Park, Jongbum;Lee, Ji Youn;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.2
    • /
    • pp.80-84
    • /
    • 2018
  • $[^{13}N]$Ammonia or $[^{13}N]NH_3$ is one of the most widely used PET tracer for the measurement of MBF. To produce $[^{13}N]NH_3$, devarda's alloy which contains aluminum, copper and zinc is used for the purpose of reduction from $^{13}N$-nitrate/nitrite to $[^{13}N]NH_3$. Since aluminum has neurotoxicity and renal toxicity, the amount of it should be carefully limited for the administration to the human body. Although USP and EP provide a way to identify the aluminum ion concentration, there are some difficulties to perform. Therefore, we tried to develop the modified method for verifying aluminum concentration of test solution. We compared color between test and standard solutions using chrome azurol S in pH 4.6 acetate buffer. We also tested color change of test and standard solutions according to pH, amounts and the order of reagent and time difference These results demonstrated that the color change of the solution can reflect quantitatively measure aluminum ion concentration. We hope the method is to be used effectively and practically in many sites where $[^{13}N]NH_3$ is produced.

Emission Factor and Fuel Economy Calculation Using Vehicle Inspection and Maintenance Program (자동차 환경검사에 의한 대기오염물질 배출계수 및 연비 산출)

  • Lee, Tae-Woo;Keel, Ji-Hoon;Park, Jun-Hong;Eom, Myoung-Do;Kim, Jong-Choon;Lee, Dae-Yup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.97-106
    • /
    • 2009
  • An objective of this study is to give practical information that could be used for calculating pollutant emission factors and fuel economy from Korean Inspection & Maintenance program, which has been using steady state acceleration simulation mode. Concentration results from I/M test is adequately converted to mass emission factors and fuel efficiency data, which have unit of g/km and km/L, respectively. Exhaust volume flow(EVF), which is for converting emission result from concentration to mass, is measured by tracer method in various vehicle speed - power condition. It is found that there is an apparent second order relationship between EVF and vehicle inertia weight. EVF is expressed in function of vehicle inertia weight in order to estimate EVF in I/M site without measuring device. Converted mass emission results from measured EVF and raw emission analyzer show a satisfactory agreement with those from conventional CVS-bag type measurement system. Mass emission factors and fuel efficiency from measured EVF and estimated EVF also show good agreement to each other. Considering that an I/M program has great advantages to recruit-based emission test in terms of the number of test vehicle, the information in this study can be used for developing an alternative procedure to collect more various data to establish national database of mobile emission factors and fuel economy, even though the driving cycle in I/M program is steady state cycle rather than transient cycle.

The Radio-Immunoassay Method for Ginsenoside $Rg_1$ of Korean Ginseng

  • Han, Byung-Hoon;Han, Yong-Nam;Sankawa, Ushio;Akyama, Minko;Kawashima, Koichiro
    • Korean Journal of Pharmacognosy
    • /
    • v.11 no.3_4 s.43
    • /
    • pp.133-140
    • /
    • 1980
  • In order to develop the radio-immunoassay procedure for the ginsenoside $Rg_1$ we prepared the $Rg_1-BSA$ conjugate and $Rg_1-tyramine$ conjugate by condensing the $Rg_1-azide$, which was prepared by a series of six step chemical modification of the $Rg_1-side$ chain, with bovine serum albumin(BSA) or with tyramine. Rabbits were immunized by repeated injection of $Rg_1-BSA$ conjugate with Freund's Complete Adjuvant for 5 month long to obtain very potent $anti-Rg_1$ serum. The radio-labelled haptene was prepared by direct radio-iodination $(125_J)$ of $Rg_1-tyramine$ according to the chloramine-T method. The radio-immunoassay procedure was successfully furnished by using DCC method (dextran coated charcoal) and the anti-body titer of the anti-serum was found as being $1600{\sim}3200$ by using 15000cpm tracer per test. Calibration test using non-labelled $Rg_1$ showed linear competetive binding response in the $(8-300){\times}34pg$. range of non-labelled $Rg_1$. The cross reaction test using 19 ginsenoside analogues enabled us a full structure-activity analysis on the antigen-antibody reaction that the anti-body in the serum would recognize the full structure of ginsenoside $Rg_1$ except the side chain moiety.

  • PDF

Two-dimensional deformation measurement in the centrifuge model test using particle image velocimetry

  • Li, J.C.;Zhu, B.;Ye, X.W.;Liu, T.W.;Chen, Y.M.
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.793-802
    • /
    • 2019
  • The centrifuge model test is usually used for two-dimensional deformation and instability study of the soil slopes. As a typical loose slope, the municipal solid waste (MSW) landfill is easy to slide with large deformation, under high water levels or large earthquakes. A series of centrifuge model tests of landfill slide induced by rising water level and earthquake were carried out. The particle image velocimetry (PIV), laser displacement transducer (LDT) and marker tracer (MT) methods were used to measure the deformation of the landfill under different centrifugal accelerations, water levels and earthquake magnitudes. The PIV method realized the observation of continuous deformation of the landfill model, and its results were consistent with those by LDT, which had higher precision than the MT method. The deformation of the landfill was mainly vertically downward and increased linearly with the rising centrifugal acceleration. When the water level rose, the horizontal deformation of the landfill developed gradually due to the seepage, and a global slide surface formed when the critical water level was reached. The seismic deformation of the landfill was mainly vertical at a low water level, but significant horizontal deformation occurred under a high water level. The results of the tests and analyses verified the applicability of PIV in the two-dimensional deformation measurement in the centrifuge model tests of the MSW landfill, and provide an important basis for revealing the instability mechanism of landfills under extreme hydraulic and seismic conditions.

Development of Genetic Algorithm based 3D-PTV and its Application to the Measurement of the Wake of a Circular Cylinder (GA기반 3D-PTV 개발과 원주 후류계측)

  • Doh, D.H.;Cho, G.R.;Cho, Y.B.;Moon, J.S.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.548-554
    • /
    • 2001
  • A GA(Genetic Algorithm) based 3D-PTV technique has been developed. The measurement system consists of three CCD cameras, Ar-ion laser, an image grabber and a host computer. The fundamental of the developed technique was based on that one-to-one correspondence is found between two tracer particles selected at two different image frames taking advantage of combinatorial optimization of the genetic algorithm. The fitness function controlling reproductive success in the genetic algorithm was expressed by a kind of continuum theory on the sparsely distributed particles in space. In order to verify the capability of the constructed measurement system, a performance test was made using the LES data set of an impinging jet. The developed 3D-PTV system was applied to the measurement of flow characteristics of the wake of a circular cylinder.

  • PDF