• 제목/요약/키워드: Total temperature measurement

검색결과 264건 처리시간 0.026초

실내 온도가 재실자의 주의집중력에 미치는 영향에 관한 연구 (The effect of indoor temperature on occupants' attention abilities)

  • 최유림;전정윤
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년 춘계학술발표대회 논문집
    • /
    • pp.199-203
    • /
    • 2009
  • The purpose of this research is to investigate how the indoor temperature has influence on occupants' attention abilities as a basis of productivity. To achieve the purpose, the experiment in chamber was conducted. In the experiment, temperature was controlled according to two levels ($20^{\circ}C$ or $23^{\circ}C$) and other of factors were controlled uniformly. Subjects were exposed to those two different thermal environments. Each participant was asked to mark their answers on the state of attention measurement sheets (FAIR and Trail making test), in two conditions. Total 60 times of experiments were conducted. The main results are as follows. First, subjects showed the better attention abilities in relation to Q score at $20^{\circ}C$. But on the other hand attention abilities in relation to C score were better at $23^{\circ}C$. Second, subjects showed the better attention abilities in relation to concentrate on one task at $20^{\circ}C$.

  • PDF

사파이어 광섬유를 이용한 용선 온도측정 (Measurement of the Molten Steel Temperature Using the Sapphire Fiber)

  • Kim, Hasul;Homun Bae
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.240-241
    • /
    • 2000
  • Sapphire fiber has been used to provide an optical path for the total radiation pyrometry. In measuring the temperature, we use the two-color detector, which consists of a high-performance Silicon detector mounted in a "sandwich" configuration over a Germanium detector. Sapphire fiber can withstand high temperature in the molten steel for two and a half hours. The maximum value of the error is the $\pm$2.5$^{\circ}C$ in the range of 152$0^{\circ}C$~1$600^{\circ}C$. This paper presents the simple scheme for measuring the molten steel temperature in the blast furnace of the iron & steel making process.g process.

  • PDF

Toward Next Generation Solar Coronagraph: Diagnostic Coronagraph Experiment

  • Cho, Kyung-Suk;Yang, Heesu;Lee, Jaeok;Bong, Suchan;Choi, Seonghwan;Kim, Jihun;Park, JongYup;Park, YoungDeuk;Kim, Yeon-Han
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.42.2-42.2
    • /
    • 2019
  • Korea Astronomy and Space Science Institute (KASI) has been developing a next-generation coronagraph (NGC) in cooperation with NASA to measure the coronal electron density, temperature, and speed using four different filters around 400 nm. To demonstrate technology for the measurement through the 2017 total solar eclipse across the USA, KASI organized an expedition team to demonstrate the coronagraph measurement scheme and the instrumental technology. The observation site was in Jackson Hole, Wyoming, USA. We built an eclipse observation system, so-called Diagnostic Coronal Experiment (DICE), which is composed of two identical telescopes to improve a signal to noise ratio. The observation was conducted with 4 wavelengths and 3 linear polarization directions according to the planned schedule in a limited total eclipse time of about 140 seconds.Polarization information of corona from the data was successfully obtained but we failed to get the coronal electron temperature and speed information due to a low signal-to-noise ratio of the optical system. In this study, we report the development of DICE and observation results. TSE observation and analysis by using our own developed instrument gave an important lesson that a coronagraph should be carefully designed to archive the scientific purpose. This experience through TSE observation will be very useful for a success of NASA-KASI joint missions called the Balloon-borne Investigation of the Temperature and Speed of Electrons in the Corona (BITSE) and COronal Diagnostic EXperiment (CODEX).

  • PDF

초기 지중온도 측정이 지중 열교환기 설계에 미치는 영향 (Effect of initial ground temperature measurement on the design of borehole heat exchanger)

  • 송윤호;김성균;이강근;이태종
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.600-603
    • /
    • 2009
  • We compared relative importance of thermal conductivity and initial ground temperature in designing borehole heat exchanger network and also we test accuracy of ground temperature estimation in thermal response test using a proven 3-D T-H modeler. The effect of error in estimating ground temperature on calculated total length of borehole heat exchanger was more than 3 times larger than the case of thermal conductivity in maximum 20% error range. Considering 10% of error in estimating thermal conductivity is generally acceptable, we have to define the initial ground temperature within 5% confidence level. Utilizing the mean annual ground surface temperature and the geothermal gradient map compiled so far can be a economic way of estimating ground temperature with some caution. When performing thermal response test for estimating ground temperature as well as measuring thermal conductivity, minimum 100 minutes of ambient circulation is required, which should be even more in case of very cold and hot seasons.

  • PDF

A Study on Blister Formation and Electrical Characteristics with Varied Annealing Condition of P-doped Amorphous Silicon

  • 최성진;김가현;강민구;이정인;김동환;송희은
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.346.2-346.2
    • /
    • 2016
  • The rear side contact recombination in the crystalline silicon solar cell could be reduced by back surface field. We formed polycrystalline silicon as a back surface field through crystallization of amorphous silicon. A thin silicon oxide applied to the passivation layer. We used quasi-steady-state photoconductance measurement to analyze electrical properties with various annealing condition. And, blister formed on surface of wafer during the annealing process. We observed the blister after varied annealing process with wafer of various surface. Shape and density of blister is influenced by various annealing temperature and process time. As the annealing temperature became higher, the average diameter of blister is decreased and total number of blister is increased. The sample with the $600^{\circ}C$ annealing temperature and 1 min annealing time exhibited the highest implied open circuit voltage and lifetime. We predicted that the various shape and density of blister affects the lifetime and implied open circuit voltage.

  • PDF

92 GHz Radiometer System for Remote Sensing Applications

  • Kim, Yong-Hoon;Kim, Sung-Hyun;Kang, Gum-Sil;Kim, Han-Sik;Yang, Ki-Seok
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.462-467
    • /
    • 1999
  • In this paper, very high performance millimeter-wave radiometer of 92 GHz is presented. Radiometer system design, brightness temperature measurement and calibration methods are described. The architecture of radiometer including data acquisition, storage and digital signal processing using a notebook computer are explained and some experimental data in the laboratory are introduced. The system noise figure and total gain of implemented radiometer are 12 dB and 56 dB, respectively. The system stability is evaluated from the experiment. The difference of the detector output voltage for two targets, whose brightness temperature are 80 K and 300K, is 4 mV. The mechanical scanning method is considered to get a brightness temperature Image of the earth surface scene.

  • PDF

온도 변화에 따른 진행파 전극형 광 변조기의 전기적 특성 변위에 관한 연구 (Temperature-dependent Electrical Characteristics of Traveling Wave Electro-absorption Modulator)

  • 류근호;윤일구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.63-64
    • /
    • 2006
  • Recently, researches for high-speed optical devices have been increased to provide mass data transmission and high-speed optical communication. Optical modulator in the transmission link is one of the crucial devices in total optical network system and it can affect a great effect to the whole transmission properties. In this paper, traveling wave electro-absorption modulator (TWEAM) is examined to ensure high efficiency in the RF range and wide bandwidth. In addition, the temperature-dependence electrical characteristics of TWEAM is investigated. Temperature dependent property variations were characterized using I-V and C-V measurement.

  • PDF

凝縮을 隨伴하는 超音速 노즐흐름의 全壓損失 (Total Pressure Loss in a Supersonic Nozzle Flow with Condensation)

  • 강창수;권순범
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.582-589
    • /
    • 1988
  • 본 연구에서는 작동유체로서 습공기를 사용하였을때 수반되는 응축에 의한 전 압손실을 실험과 수치해석을 통하여 정체점에 있어서의 습공기의 온도, 과포화도 및 노즐 팽창율의 효과와 액적 질량비 (g)과의 관계로서 구명하였다.

5kW급 투광형 박막 BIPV시스템의 실증연구 (Case Study on 5kWp Transparent Thin-Film BIPV System)

  • 안영섭;김성태;이성진;송종화;황상근;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.29-35
    • /
    • 2010
  • This study has been carried out empirical research on Transparent Thin-film BIPV modules, BIPV modules installed on the exterior of the building are applied a laminated module 1kWp, double-glazing module 3kWp and triple-glazing module 1kWp. Applied to the total capacity of BIPV modules are 5kWp. In this study, design and construction process of BIPV systems is presented. In addition, through monitoring of the BIPV system, the temperature and the power characteristics of each module were analyzed. During the measurement period, the module temperature measurement results, the maximum surface temperature of $51.5^{\circ}C$ triple-glazing BIPV module showed the highest, followed by double-glazing BIPV module $49.1^{\circ}C$, $44.7^{\circ}C$ laminated modules, respectively. Power output results, the daily average double-layer modules showed 4.10kWh/day, triple-glazing module 1.57kWh, respectively 1.81kWh laminated modules. In particular, the power efficiency of triple-glazing BIPV module was lower than the power efficiency of the laminated BIPV module. This phenomenon is considered to be affected by the module temperature. In the future, BIPV modules in this study the relationship between module temperature and power characteristics plans to identify.

탑상형 아파트의 배치방향별 봄철 실내온도 비교평가 (Comparative Evaluation of Indoor Temperature in Spring according to Sitting Orientation of Tower-Type Apartments)

  • 김준현;엄정섭
    • 환경영향평가
    • /
    • 제20권2호
    • /
    • pp.175-185
    • /
    • 2011
  • It is usual for energy consumption in accordance with facing and sitting direction of tower-type apartments to be calculated by the official statistics or computer simulation. Previous studies for energy consumption appear to be very limited due to the dependence on flat type of apartment. Acknowledging these constraints, an empirical study for a tower type apartment was conducted to demonstrate how a on-site indoor temperature measurement in spring can be used to assist in estimating the total energy consumption in terms of facing and sitting orientation specific settings. The results indicate that maximum temperature difference in spring was identified as $1.16^{\circ}C$ between south and eastern direction. It is known that raising $1^{\circ}C$ indoor temperature require 7% more energy consumption than normal. The $1.16^{\circ}C$ difference means that sitting direction of tower type apartment is a crucial explanatory variable as unit of analysis for energy consumption. It was demonstrated that the indoor temperature could be used effectively as an indicator to estimate energy consumption among various sitting direction of tower type apartments. It is anticipated that this research output could be used as a valuable reference to support more scientific and objective decision-making for facing and sitting orientation of tower type apartments.