• Title/Summary/Keyword: Total suspended particulate

Search Result 149, Processing Time 0.024 seconds

Classification of Ambient Particulate Samples Using Cluster Analysis and Disjoint Principal Component Analysis (군집분석법과 분산주성분분석법을 이용한 대기분진시료의 분류)

  • 유상준;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.1
    • /
    • pp.51-63
    • /
    • 1997
  • Total suspended particulate matters in the ambient air were analyzed for eight chemical elements (Ca, Co, Cu, Fe, Mn, Pb, Si, and Zn) using an x-ray fluorescence spectrometry (XRF) at the Kyung Hee University - Suwon Campus during 1989 to 1994. To use these data as basis for source identification study, membership of each sample was selected to represent one of the well defined sample groups. The data sets consisting of 83 objects and 8 variables were initially separated into two groups, fine (d$_{p}$<3.3 ${\mu}{\textrm}{m}$) and coarse particle groups (d$_{p}$>3.3 ${\mu}{\textrm}{m}$). A hierarchical clustering method was examined to obtain possible member of homogeneous sample classes for each of the two groups by transforming raw data and by applying various distances. A disjoint principal component analysis was then used to define homogeneous sample classes after deleting outliers. Each of five homogeneous sample classes was determined for the fine and the coarse particle group, respectively. The data were properly classified via an application of logarithmic transformation and Euclidean distance concept. After determining homogeneous classes, correlation coefficients among eight chemical variables within all the homogeneous classes for calculated and meteorological variables (temperature. relative humidity, wind speed, wind direction, and precipitation) were examined as well to intensively interpret environmental factors influencing the characteristics of each class for each group. According to our analysis, we found that each class had its own distinct seasonal pattern that was affected most sensitively by wind direction.ion.

  • PDF

Exposure to Fine Particle along Different Commuting Routes in Urban Area of Fukuoka, Japan

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.205-213
    • /
    • 2015
  • The objective of the current study was to assess the comparative risk associated with exposure to particulate matter (PM) while commuting via different public transport modes in Fukuoka, Japan. For the given routes and measuring days, a trip-maker carried a lightweight portable bag loaded the real-time measurement devices which take simultaneous measurement for size-fractioned particle number concentration, $PM_{2.5}$ mass concentration, and total suspended particle (TSP) collection. The results of the present study have shown significant differences between public transports as commuting modes in Fukuoka. The PM exposure levels on subway platform and inside subway train were overwhelmingly higher than those of other points on commuting route. The relative ratio between modes (i.e., the ratio of $PM_{2.5}$ inside subway to that inside bus) provides an idea for choosing a right commuting mode for our health. This study clearly provided evidence of the extremely high levels of iron exposure by subway uses compared to bus uses. The result of theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ collected on subway platform suggests that the PM of underground subway will be associated with PM both generated in subway system and inleakaged from outdoor environment.

A Study on the Status of Air and Water Pollutants Emission from Industries in Korea (전국(全國) 산업장(産業場)에서 배출(排出)되는 오염물질량(汚染物質量)에 관(關)한 연구(硏究))

  • Cha, Chul-Hwan;Jang, Chang-Supp;Kim, Hyung-Won;Sung, Young-Ja
    • Journal of Preventive Medicine and Public Health
    • /
    • v.6 no.1
    • /
    • pp.27-41
    • /
    • 1973
  • In order to provide some basic data for the control of air and water pollution in Korea, the authors have estimated the amount of air and water pollutants emitted from industries which are employed over 20 employees. This study have done from July 1, 1972 to the end of March 1973. The results are as followings; 1. Total number of establishments with over 20 employees is 5,197 in Korea and the largest group establishments was the manufacturing of textiles with 1,363 establishments (26.2%). 2. By order of number of employees it was observed that there 2,800 industries with 20-59(53.9%) employees, 1,101 with 50-99 (21.2%), 571 with 100-199 (11.0%), 501 with 200-499 (9.6%) and 225 with over 500 (4.3%) respectively. 3. By order of regional distribution, it was observed that there were 2,257 industries in Seoul (43.2%) and 736 industries in Pusan(14.2%). 4. Industrial coal consumption was 596,154 M/T in 1972, but it' 11 be 315,000 M/T in 1980. Fuel consumption was 4,972,000 K1 in 1972, and estimated volume will be 19,370,000 K1 in 1980. 5. Total amounts of air polutants entitled from industries by fuel combustion were sulfur oxides 79,459 tons, carbon monoxide 33,908 tons, particulate 31,304 tons and hydrocarbon 30,280 tons in 1972 but in 1990 there will be sulfur oxides 1,010,474 tons, nitrogen oxides 204,575 tons, carbon monoxide 68,014 tons, particulate 64,820 tons and hydrocarbon 67,622 tons, respectively. 6. Annual emitted air pollutants through the working processes were sulfur oxides 91,250 tons and nitrogen oxides 32,485 tons in 1972, but sulfur oxides 118,625 tons and nitrogen oxides 42,555 tons will be present in 1980, respectively. 7. Annual emitted air pollutants by national unit area amounted to $0.77ton/km^2/year$ in 1965 and $14.7ton/km^2/year$ in 1980. 8. Total industrial wastes from all industries in Korea were estimated at 810,360 tons/day in 1972; manufacturing of chemicals and plastic products showed the highest amount of wastes at 470,000 tons/day. 9. The amounts of water pollutants due to industrial wastes were the B.O.D., 471.5 tons/day, suspended solid 331.5 tons/day, CN, 2.3 tons/day, and Cr. 3.4 tons/day in 1972, but it might be evident of a B.O.D. of 3,388 tons/day, suspended solid 2,544 tons/day, CN 20.1 tons/day, and 26.5 tone/day in 1990. 10. Total population equivalent of B.O.D. was 943,000 in 1972, and the estimated value in 1950 will be 6,780,000.

  • PDF

Spatial Interpretation of Monsoon Turbid-water Environment in a Reservoir (Yongdam) Discharging Surface Water, Korea (표층수를 방류하는 저수지(용담호)에서 몬순 탁수환경의 공간적 해석)

  • Shin, Jae-Ki;Hur, Jin;Lee, Heung-Soo;Park, Jae-Chung;Hwang, Soon-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.933-942
    • /
    • 2006
  • In this study, temperature, turbidity, suspended paniculate matter (SPM) distribution and mineral characteristics were investigated to explain spatial distribution of the turbid-water environment of Yongdam reservoir in July, 2005. Six stations were selected along a longitudinal axis of the reservoir and sampling was conducted in four depths of each station. Water temperature was showed the typical stratified structure by the effects of irradiance and inflow. Content of inorganic matter in suspended particles increased with the concentration of suspended particulate matter (SPM) due to the reduction of ash-free dry matter (AFDM). Turbidity ranged from 0.6 to 95.1 NTU and the maximum turbidity value of each station sharply increased toward downstream from upstream. The high turbidity layers were located at the depth between 12~16 m. Particle size ranged from 0.435 to $482.9{\mu}m$. day and silt-sized particles corresponded 91.9~98.9% and 1.1~8.0% in total numbers of SPM, respectively. Turbidity showed high correlations with clay (r=0.763, p<0.05) and silt content (r=0.870, p<0.05).Inorganic matter content (r=0.960, p<0.01) was more correlated with turbidity than organic matter (r=0.823, p<0.05). Mineral characterization using x-ray diffraction and electron probe microanalyzer demonstrated that the major minerals contained in the SPM were kaolinite, illite, vermiculite and smectite. As results of this study, surface water discharge as well as small size of the SPM were suggested as long-term interfering factors in settling down the turbid water in the reservoir.

Source Identification of Ambient Size-by-Size Particulate Using the Positive Matrix Factorization Model on the Border of Yongin and Suwon (PMF 모델을 이용한 용인-수원경계지역에서의 부유분진의 크기별 오염원 확인)

  • Oh, Mi-Seok;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.2
    • /
    • pp.108-121
    • /
    • 2009
  • The suspended particulate matters have been collected on membrane filters and glass fiber filters by an 8-stage cascade impactor for 2 years (Sep. 2005${\sim}$Sep. 2007) in Kyung Hee University-Global Campus located on the border of Yongin and Suwon. The 20 chemical species (Al, Mn, Si, Fe, Cu, Pb, Cr, Ni, V, Cd, Ba, $Na^+$, ${NH_4}^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, ${NO_3}^-$, and ${SO_4}^{2-}$) were analyzed by an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on these chemical information, the PMF receptor model was applied to identify the source of ambient size-by-size particulate matters. The receptor modeling is the one of the statistical methods to achieve resonable air pollution management strategies. A total of 10 sources was identified in 9 size-ranges such as long-range transport, secondary aerosol, $NH_{4}NO_{3}$ related source, coal combustion, sea-salt, soil, oil combustion, auto emission, incineration, and biomass burning. Especially, the secondary aerosol source assorted in fine and coarse modes was intensively studied.

Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion (플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과)

  • Kim, Yoon-Shin;Kim, Ki-Youn;Cho, Man-Su;Ko, Moon-Suk;Ko, Han-Jong;Jung, Jin-Won;Oh, Mi-Seok;Youn, Baek;Kim, Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

Monitoring of Dust Concentration Generated during Peach Sorting Operations (복숭아 선별작업장의 미세먼지의 발생특성 모니터링)

  • Seo, Hyo-Jae;Seo, Il-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.237-245
    • /
    • 2022
  • Peach is a typical summer fruit which can be used for various food, processed food, and fragrance ingredients in Korea. Peach is also known as one of serious allergens which make difficulty for farm workers during peach sorting operations. After peach harvesting, it moves to the sorting operations for removing cover material, removing fuzz on peach surface, sorting by size, and packing. The air-samplers and optical particle counters were used to analyze the characteristics of fine dust generation by location and operation characteristics in the experimental peach farms. During removing peach fuzz, the dust concentrations were increased by 6.89 times on total suspended particulate (TSP), 2.13 times on PM-10 (particulate matter), and 1.30 times on PM-2.5 compared to non-working periods, respectively. During removing peach covering materials, the dust concentrations were increased by 3.14 times on TSP, 1.91 times on PM-10, and 1.43 times on PM-2.5 compared to non-working periods, respectively. This represents peach fuzz can be affected to farm workers during peach sorting operations.

A Study on Chemical Composition of Dustfall Samples in Cheju Area - 1. Chemical composition and deposition (제주지역 강하 먼지의 조성에 관하여 - 1. 화학적 조성 및 침적량)

  • 이기호;허철구;송문호;박용이
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.13-22
    • /
    • 1999
  • This study is carried out to investigate the chemical composition of atmospheric deposition in Cheju Island, Korea. For this purpose, dustfall matter samples are collected by dust jar from August, 1995 to July, 1996 at five sampling sites and total suspended particulate matters (TSP) and rain are also collected at one site from October, 1995 to July, 1996. All the samples collected are analyzed, and then the information of the 19 chemical species and deposition amount of each species is obtained. These data are used to determine the regional trends in dustfall chemistry and deposition, and compare the characteristics of chemical compositions between dustfall, TSP and rainwater.

  • PDF

Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility

  • Mi Sung Jo;Hoi Pin Kim;Boo Wook Kim;Richard C. Pleus;Elaine M. Faustman;Il Je Yu
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.114-117
    • /
    • 2024
  • A lithium-ion battery is a rechargeable battery that uses the reversible reduction of lithium ions to store energy and is the predominant battery type in many industrial and consumer electronics. The lithium-ion batteries are essential to ensure they operate safely. We conducted an exposure assessment five days after a fire in a battery-testing facility. We assessed some of the potentially hazardous materials after a lithium-ion battery fire.We sampled total suspended particles, hydrogen fluoride, and lithium with real-time monitoring of particulate matter (PM) 1, 2.5, and 10 micrometers (㎛). The area sampling results indicated that primary potential hazardous materials such as dust, hydrogen fluoride, and lithium were below the recommended limits suggested by the Korean Ministry of Labor and the American Conference of Governmental Industrial Hygienists Threshold Limit Values. Based on our assessment, workers were allowed to return to work.

Seasonal Variation of the Quantity and Quality of Seston as Diet Available to Suspension-Feeders in Gosung and Kangjin Bays of Korea (고성만과 강진만에서 현탁물 섭식자에 유용한 입자물질 양과 질의 계절 변동)

  • LEE Pil-Yong;KANG Chang-Keun;CHOI Woo-Jeung;YANG Han-Seob
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.4
    • /
    • pp.340-347
    • /
    • 2001
  • Seasonal variation of the elemental and biochemical composition of the suspended particulate matter (SPM) was investigated in terms of quantity and quality of diets for suspension feeders from July 1999 to August 2000 in two coastal bay systems of Gosung and Kangjin Bays in Korea. No clear patterns in the seasonal variations of SPM concentration were found in these two bay systems. The results indicated that the seasonal variation of SPM could not be considered the variation of food available to suspension-feeders. The simultaneous peaks in chlorophyll a and biochemical components in summer indicated that the quantity of the particulate organic matter primarily depended on phytoplankton productivity. However, no correlation between chlorophyll a and biochemical components [particulate protein (PPr), carbohydrate (PCHO) and lipid] were found, indicating that other processes might also contribute to the particulate organic matter in the period when the phytoplankton biomass was low. High C: Chl a and C:N, and carbohydrate peaks during the autumn to spring period suggested that resuspension of surface sediments was a probable process to supply the particulate organic matter. The food material, represented by summing up the total quantity of three biochemical components, was highest in spring with minor peaks during the period from autumn to the next spring, The food index, calculated as the ratio of food material to total SPM, did not generally exceed $6\%$ with short peaks during the year. Therefore, nutritional quality of SPM in the bays are relatively poor than in other more productive coastal waters in the world. Our results confirm that the measurement of a single chemical variable cannot describe fully the nutritive value of the seston available to suspension-feeders as previously proposed, and the biochemical composition of SPM can provide effective information on its origin and nutritive Quality.

  • PDF