• 제목/요약/키워드: Total removal

검색결과 1,863건 처리시간 0.026초

RBC 반응조를 이용한 2단 A/O 공정에서 유기물질 및 질소제거 (Removal of Organics and Nirtogen in Wastewater Using 2 Stage A/O(RBC) Process)

  • 최명섭;손인식
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.59-64
    • /
    • 2003
  • This study was conducted to investigate anoxic-RBC-anoxic-RBC process and its application to remove biologically organics and nitrogen. BOD and total-nitrogen(T-N) removal efficiencies were decreased as volumetric loading rate increased. But, the removal efficiency changes of T-N were little, as compared to BOD. Increase of internal recycle rate had few affect of BOD and T-N removal rates. Also, influent allocation(to 2nd anoxic reactor) had few affect of BOD removal efficiency rate. However, when the influent allocation rate was 30%, T-N removal efficiency was increased to 84.1 %. BOD/N ratio applied to 2nd anoxic reactor was increased to range of 3.65-4.37 as influent allocation rate increased to range 20∼35%. But, it might also cause adverse effect such as decrease of denitrification rate in excessive influent allocation rate.

간헐폭기식 활성슬러지 공법에 의한 질소, 인 제거 (Removal of N and P by Intermittented Aeration Activated Sludge Process)

  • 김동밀;이영신
    • 한국환경보건학회지
    • /
    • 제18권2호
    • /
    • pp.57-61
    • /
    • 1992
  • This study was made for enhanced removal of N and P by intermittented aeration Activated Sludge Process. Experiment were conducted to find the effects of aeration interval and nutrient removal efficiency. When applied aeration interval were 30~60 min, 2~4 h, 4~8 h, organic matter was not affected while phosphorous removal was aeration interval 30~60 min. Also, when applied mixing intensity were 15, 30, 45 and 60 rpm, organic matter was not affected while removal was maximum at 15 rpm. Total nitrogen and phosphorous removal were in the range of 76 and 85%. Density and MLSS of Sludge were in the range of 2.3~2.6 and 7198~7810 mg/l. Release of phosphorous from activated sludge under unaerobic condition was increased as pass time.

  • PDF

효과적인 구리 제거제 합성 및 처리 기술 개발에 관하여 (Synthesis of Removal Agent and Developement of Treatment Technology on Copper)

  • 조병락
    • 한국산업융합학회 논문집
    • /
    • 제16권2호
    • /
    • pp.35-39
    • /
    • 2013
  • This paper synthesized the new copper removal agent(PW-2001) and investigated removal efficiency of copper, COD, calcium, SS and sludge amounts. Removal efficiency of copper were 96.1% and 99.1% with the lime and PW-2001, respectively while COD removals reached up to 38% and 69.6% with the use of lime and PW-2001. The concentrations of calcium and SS with PW-2001 were decreased 2.68 and 4.95 times lower than those with lime. Amount of sludge with PW-2001 was 60% smaller than lime. Quantity of PW-2001 needed for coagulation only reached 58.7, compared to lime standard quantity(100), and total cost of copper removal with PW-2001 was saved 25% more than lime.

향류 공기 구동식, 고속 폭기식 및 벤튜리식 포말분리기에 의한 양어장수의 단백질 및 부유 고형물의 제거 특성 (Characteristics of Proteins and Total Suspended Solids Removal by Counter Current Air Driven Type, High Speed Aeration Type and Venturi Type Foam Separator in Aquacultural Water)

  • 서근학;김병진;김성구
    • 한국수산과학회지
    • /
    • 제33권3호
    • /
    • pp.205-212
    • /
    • 2000
  • 공기 구동식, 고속 폭기식 및 벤튜리식 포말분리 장치를 동일한 용량으로 제작하여 양어장 순환수 중의 단백질,총 부유 고형물 및 탁도를 제거하는데 있어 각 포말 분리장치의 운전 특성을 알아보고자 하였다. 공기구동식 포말분리기의 유략감소가 거의 없었으나 벤튜리식 포말분리기는 $66.1{\%}$정도의 유량감소가 발생하였으며 고속 폭기식 포말분리기는 $77.2{\%}$의 유량감소가 발생하였다. 공기 구동식, 고속 폭기식 및 벤튜리식 포말분리 장치의 단백질 제거속도는 수력학적 체류시간이 증가함에 따라 지수적으로 감소 하였다. 0.32 분 이상의 수력학적 체류시간에서는 공기 구동식 포말분리장치의 제거속도와 제거율이 가장 높게 나타났으며 그 이하의 수력학적 체류시간에 대해서는 고속 폭기식 포말분리 장치의 제거속도와 제거율이 가장 높은 것으로 나타났다. 수력학적 체류시간의 변화에 따른 총 부유 고형물과 탁도의 제거속도와 제거율의 변화는 단백질 제거속도 및 제거율의 변화와 거의 비슷하였으며 벤튜리식 포말분리기는 짧은 수력학적 체류시간에서는 총 부유고형물의 제거 효율이 다른 두 포말분리기에 비해 떨어지는 것으로 나타났다. 탁도의 제거는 공기 구동식 포말 분리기가 가장 우수한 것으로 나타났다.

  • PDF

인공 저류지를 이용한 축산 지역 비점오염물질 유출 저감 효율 분석 (Analysis on the Runoff Reduction Efficiency of Non Point Pollutants in Animal Feeding Area Using Artificial Reservoir)

  • 어성욱
    • 한국습지학회지
    • /
    • 제20권4호
    • /
    • pp.417-423
    • /
    • 2018
  • 축산 지역 하류에 위치한 농업용 저수지의 강우시 유입, 유출수 분석을 통해 축산지역의 강우 유출 특성과 저류지에 의한 축산계 비점 오염물질의 저류형 시설에 의한 유출 저감 효율을 분석하였다. 급경사지에 위치한 한우 축산 지역의 비점 오염물질 유출은 주로 초기세척현상에 의해 발생됨을 알 수 있었으며 강우시의 유입수 농도는 비강우시에 비해 SS농도가 가장 높게 발생하고 있으며 T-P도 4배 이상 증가하는 양상을 보인다. 반면 총질소는 평균 30% 증가하는 것으로 나타나는데 질소항목으로 보면 질산성 질소는 거의 변화가 없는 반면에 암모니아성 질소가 2배 이상 증가하고 있다. 저류형 비점 제거시설 효율 분석 결과 비강우시 총인 제거효율이 53%로 가장 높고 부유물질은 37% 제거되고 있다. 유기물질은 10% 내외, 총질소는 5% 이내로 제거되며 부영양화로 녹조가 번성하는 하절기에는 오히려 유출수의 질소농도가 더 높아지는 경우도 빈번히 발생하고 있다. 강우시의 유입수 농도는 비강우시에 비해 SS농도가 가장 높게 발생하고 있으며 T-P도 4배 이상 증가하는 양상을 보인다. 강우시 부유물질의 제거효율은 60%로 나타나고 있으며 총인은 22% 제거되어 비강우시에 비해 제거효율은 감소하고 있다. 환경부의 비점제거시설 기준보다 9배 이상의 용량을 지니고 있지만 비점 전용 시설로 활용되지 못하는 탓에 장마철에 거의 만수 상태로 담수하여 비점제거 효율에 있어서는 충분한 효과를 보이지 못하고 있는 것으로 나타나 저수지의 용량 뿐 아니라 수문관리 등 유지관리도 비점 제거효율에 영향을 미치는 중요 인자로 분석되었다.

휘발성 지방산의 주입을 통한 생물학적 영양염류 제거공정의 효율증진에 관한 연구 (Enbancement of Treatement Efficiency in a Biological Nutrient Removal Process by addition of Volatile Fatty Acids)

  • 정연규;고광백;김수진;임성균
    • 상하수도학회지
    • /
    • 제10권3호
    • /
    • pp.73-82
    • /
    • 1996
  • The removal efficiencies of organic substrates, nitrogen and phosphorus in the anaerobic-aerobic biological phosphorus removal process were investigated by addition of acetic acid, propionic acid and butyric acid which are normal volatile fatty acids contained in anaerobic digester supernatants. Substrate utilization coefficients for the phosphorus release and uptake were also estimated. The effect of a VFA, which showed higher phosphorus removal efficiency than the other VFAs did, was also studied in an anaerobic-aerobic-anoxic biological nutrient removal process. For the anaerobic-aerobic process added by VFA, the phosphorus removal efficiencies were up to about 68%, 55% and 61% for the reactors of acetic acid, propionic acid and butyric acid added, respectively, which indicates the efficiencies were increased by about 8-21%, comparing to that of 47% for the reactor with no VFA added. There were no significant difference in removal efficiencies for organic substrate and $NH_3-N$ without regard to addition of VFA. However, the removal efficiency of total nitrogen was increased in the case of VFA added, since $NO_3-N$ was less produced. For the anaerobic-aerobic-anoxic process added VFA, the removal efficiencies for $NH_3-N$ and $PO{_4}^{3-}-P$ were increased by 5% and 13%, respectively, comparing with them in the reactors not added VFA.

  • PDF

Surgical Results of Intramedullary Spinal Cord Ependymomas in Adults : Retrospective Analysis of 51 Cases

  • Son, Young-Je;Chung, Chun-Kee;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권3호
    • /
    • pp.164-168
    • /
    • 2006
  • Objective : The goal of treatment for spinal cord ependymoma is complete removal without postoperative neurological deficit. The authors analyzed the surgical results and factors influencing the postoperative prognosis. Methods : Fifty-one cases of primary spinal cord ependymoma, surgically treated between 1979 and 2003, were retrospectively analyzed. The mean follow-up period was 44 months. Results : Gross total removal was achieved in 42 patients and incomplete removal in nine. The proportion of complete surgical removals was influenced by tumor location and histology. Disease progression was observed in five cases [9.8%], the mean progression free interval after surgical removal was 48 months and the 5-year progression free rate was 68%. Disease progression was found in none of the 42 cases who underwent complete removal, and in 5 of 9 cases who hadincomplete removal group [P<0.001]. Statistically significant disease-progression factors by multivariate analysis were the surgical extent of removal [P=0.012]. preoperative functional status [P=0.032] the presence of intratumoral cysts [P=0.007] and postoperative radiation therapy [P=0042]. Of those patients who underwent incomplete removal, radiation therapy was found to significantly improve the clinical result [P=0042]. Conclusion : In the surgical treatment of spinal cord ependymoma, preoperative functional status, the presence of intratumoral cysts, the extent of removal, and postoperative radiation therapy were found to be significant prognostic factors of postoperative outcome.

수생식물에 의한 폐수의 오염물질제거에 관한 연구 (A Study on the Removal of Pollutants from Wastewater by Aquatic Macrophytes)

  • 조해용
    • 한국산학기술학회논문지
    • /
    • 제13권2호
    • /
    • pp.941-946
    • /
    • 2012
  • 수생식물은 폐수정화에 있어서 중요한 역할을 한다. 수생식물은 뿌리로 영양물질을 흡수해 수질개선을 할 수 있는 능력을 가지고 있다. 본 연구에서는 실험실에서 수생식물인 물상추, 자라풀, 생이가래를 각각의 수조와 혼합한 수조에서 영양물질 제거뿐만 아니라 유기물에 관해 관찰하였다. 단일수조에서 가장 많이 제거된 총 질소는 물상추가 86.47%이고, 생이가래와 물상추가 혼합 식재된 수조가 76.11%로 관찰되었다. 총인의 경우 단일수조에서 가장 많이 제거된 것은 물상추가 75.60%이고, 생이가래와 물상추가 식재된 수조가 71.11%로 관찰되었다. 암모니아제거의 경우도 두 개의 수조에서 유사한 결과가 나타났다. 또한 물상추 식재된 단일수조가 유기물이 가장 많은 68.46%로 제거를 보였다. 반면 혼합수조에서는 유기물의 제거가 생이가래와 물상추가 식재된 수조가 가장 많은 82.73%로 나타났다.

인공습지에 의한 농촌오수처리에 관한 연구 (Study on Natural Wastewater Treatment Systems by Constructed Wetland for Rural Area)

  • 윤춘경;권순국;김형중
    • 한국농공학회지
    • /
    • 제39권4호
    • /
    • pp.55-63
    • /
    • 1997
  • Constructed wetland system which can be applied to the rural wastewater treatment system was examined by pilot plant in Kon-Kuk University. Hydraulic loading rate of wastewater was about 0.16m$^3$/m$^2$. day and theoretical detention time in the system was 1.38 days. The effluent of the septic tank for the school building was applied as inflow to the system. The influent concentration of DO was zero but effluent was up to 4.37mg/${\ell}$ which implies that oxygen was supplied enough from atmosphere by reaeration to support biological activity of the system. Average influent concentration of BOD was 104mg/${\ell}$ and effluent was 24mg/${\ell}$ with average removal rate of 76%. Average influent concentration of COD was 215mg/${\ell}$ and effluent was 63mg/${\ell}$ with average removal rate of 70 % . Average influent concentration of SS was 78mg/${\ell}$ and effluent was 10mg/${\ell}$ with average removal rate of 87%. Two components, BOD and SS, are regulated by law to keep maximum water quality standard of 80mg/${\ell}$ when daily outflow rate is less than 100$m^3$/day which is the case of most rural communities. Therefore, the results from the experiment showed that constructed wetland system can meet the water quality standard easily. Average influent concentration of total nitrogen was 165mg/lwhich is relatively higher than normal wastewater, and effluent was about 156mg/${\ell}$ with average removal rate of only 6%. Average influent concentration of total phosphorus was 41 mg/${\ell}$ and effluent was 6mg/${\ell}$ with average removal rate of 87%. Overall, constructed wetland system was thought to be effective to treat wastewater if nitrogen removal mechanism is improved. Considering low cost, less maintenance, and high treatability, this system can be a practical alternative for the wastewater treatment in rural area The experiment was performed during the summer and fall season, and treatment efficiency of the system is expected to decrease in low temperature. therefore, further study including temperature is required to evaluate feasibility of the system more in detail.

  • PDF

해수의 포말분리시 공기분산기 기공크기 영향 (Effect of Air Distributor Pore Size in Foam Separator of Sea Water)

  • 서근학;김병진;이정훈;임준혁;이경범;김용하;조재윤
    • 한국수산과학회지
    • /
    • 제36권3호
    • /
    • pp.254-262
    • /
    • 2003
  • Effect of the air distributor pore size for the removal of aquacultural waste, such as protein, total suspended solids (TSS), chemical oxygen demand (COD), turbidity and total ammonia nitrogen (TAN) from sea water was investigated by using foam separator. With the increase of pore size of air distributor, removal rates and efficiency of protein decreased. Removal rate by commercial air stone was in the range between the removal rates by G2 and G4 sintered glass discs. Within the range of pore size distributor from Gl to G4, the removal efficiency of protein were ranged from 21 to $42\%.$ The changes of removal rates and efficiencies of TSS, COD and turbidity were similar to proteins. TAN was removed by stripping. The pore size of air distributor for a higher overall oxygen mass transfer coefficient and saturation efficiency provided the condition for higher protein removal rate. Also the foam separator could be used as an aerator.