• Title/Summary/Keyword: Total removal

Search Result 1,863, Processing Time 0.03 seconds

Treatment Characteristics of Wastewater with Flow Rate Variation in Anaerobic-Aerobic Activated Sludge Process

  • Lee Min-Gyu;Suh Kuen-Hack;Hano Tadashi
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.1 no.1
    • /
    • pp.11-17
    • /
    • 1997
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal efficiency of nitrogen and phosphorus compounds under experimental conditions. The average removal efficiency of total nitrogen gradually decreased as the influent total nitrogen concentration was increased. High C/N ratio of the wastewater was required for the complete removal of nitrogen. Glucose as a carbon source was more efficient than starch and the removal ability for all components become higher with the increase of the fraction of glucose.

  • PDF

Removal of Total Suspended Solids by a Foam Fractionator in a Simulated Seawater Aquaculture System

  • Peng, Lei;Jo, Jae-Yoon
    • Journal of Aquaculture
    • /
    • v.16 no.4
    • /
    • pp.216-222
    • /
    • 2003
  • In a simulated seawater aquaculture system, effects of different operating factors like the superficial air velocity (SAY), hydraulic residence time (HRT), protein concentration and foam overflow height on the removal of total suspended solids (TSS) by a foam fractionator, with 20 cm diameter and 120 cm height, were investigated. This experiment was performed on batch and consecutive modes for different combinations of the tested factors, using synthetic wastewater. In 5 consecutive trials, TSS concentration in culture tank water decreased faster, when the foam fractionator was operated at higher SAV and lower HRT. In batch trials, with increasing SAV, TSS removal rate increased, but decreased with increasing HRT. Higher protein concentration in the bulk solution resulted in higher TSS removal rate. TSS concentration in the collected foam condensates increased but the foam overflow rate decreased with increasing foam overflow height. Foam fractionation was effective for removing TSS in seawater aquaculture systems and its performance largely depended on the operating parameters, especially superficial air velocity.

Treatment Characteristics of Wastewater with Flow Rate Variation in Anaerobic-Aerobic Activated Sludge Process

  • Min-Gyu Lee;Kue
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.11-17
    • /
    • 1992
  • The treatment performances of anaerobic-aerobic activated sludge Process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal efficiency of nitrogen and phosphorus compounds under experimental conditions. The average removal efficiency of total nitrogen gradually decreased as the influent total nitrogen concentration was increased. High C/N ratio of the wastewater was required for the complete removal of nitrogen. Glucose as a carbon source was more efficient than starch and the removal ability for all components become hither with the increase of the fraction of glucose.

  • PDF

Serial Particle Size Fractionation and Water Quality in a Recirculating Aquaculture System for Eel

  • Lee, Jin-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.133-139
    • /
    • 2010
  • The effects of suspended solids size on culture water quality were determined in a commercial recirculating aquaculture system (RAS) for Japanese eel, Anguilla japonica. The particulate phase of the culture water was serially divided into six size fractions using 300, 200, 100, 75, 45, and 26 ${\mu}m$ pore size stainless sieves. The total, dissolved, and particulate nitrogen and phosphorus, and suspended solids for each fraction were determined. The concentration ranges in the fractions were: total nitrogen, 164-148 mg $L^{-1}$; total phosphorus, 20.4-15.5 mg $L^{-1}$; and total suspended solids, 8.1-6.1 mg $L^{-1}$. The concentration of total nitrogen and total phosphorus decreased significantly (P<0.05) with a 26 ${\mu}m$ and 200 ${\mu}m$ filter pore size, respectively. Nutrients from dissolved organic substances were much higher than from particulates. Analysis of particle size fractionation and its effects on water quality is useful to estimate removal efficiencies of a commercial effluent screening device for solid management and development of solid removal systems.

The pollutants removal and disinfection of secondary effluent from sewage treatment plant in loop reactor using silver nanoparticles coated on activated carbon (은나노 활성탄을 이용한 Loop Reactor에서 하수 2차 처리수 중의 오염물질 제거 및 소독 효과)

  • Seon, Yong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.361-367
    • /
    • 2016
  • Pollutants removal and disinfection effect of secondary effluent from final settling tank of sewage treatment plant of W city were investigated in Loop Reactor using ordinary granular activated carbon(GAC) and GAC coated with silver nanoparticles. The results showed that the removal efficiency of $COD_{Mn}$, T-N and T-P using GAC with silver nanoparticles were higher than using the ordinary GAC. The removal efficiency of T-P using GAC with silver nanoparticles is 45.4% and that of T-P using ordinary GAC is 30.9% in the same case of the input amount of 20 g/L of GAC. The total califorms is reduced according to increasing input amount of GAC with silver nanoparticles and ordinary GAC. The disinfection efficiency of total coliforms in case of GAC with silver nanoparticles is much higher than that in case of ordinary GAC. For all experiments using the silver nanoparticles, the total coliforms is under 26 cfu/mL and this shows very excellent disinfection effect.

Removal of Benzene and Toluene by Photo-catalyst Adsorbent Prepared from MSWI Fly Ash (소각비산재로 제조한 광촉매 흡착제의 벤젠과 톨루엔 제거특성)

  • Choi So-Young;Shim Young-Sook;Lee Woo-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.431-438
    • /
    • 2005
  • In order to apply the photocatalytic decomposition of aromatic VOCs, adsorbent prepared from MSWI fly ash was coated by $TiO_2$ solution to endow with photo-catalytic function. The effects of coating number, existence of light source and the type of $TiO_2$ solution used for coating were examined. Adsorbent coated with amorphous $TiO_2$ solution showed higher adsorptivity than adsorbent coated with crystal $TiO_2$ solution. Without light source, breakthrough curve of photo -catalyst absorbent for VOCs removal was similar to that of absorbent made from MSWI fly ash. On the other hand, breakthrough time was enlarged with light source and total removal efficiency of benzene and toluene was also increased. It can be explained as photo-decomposition effect of $TiO_2$ photo-catalyst. Total removal efficiency of benzene and toluene was increased according to the increase of coating number with light source. It was due to the effect of adsorption and photo reaction of photo-catalytic adsorbent. But total removal efficiency of benzene was lower than that of toluene. Because benzene was removed more effectively than toluene by adsorption, but photo - decomposition effect oi toluene was more high than benzene.

Organophosphorus Insecticide Residues in Fruits and Vegetables (과실 채소중 잔류농약(유기인제)에 관한 연구)

  • 윤숙자
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.83-92
    • /
    • 1990
  • Adapting two step aeration system to a waste water treatment of W-paper manufactory as Full-Scale Plants, we drew a following conclusion from its practical working. 1. Because BOD removal efficiency was 20% in A-Stage, 90% in B-Stage and total removal efficiency was 97%. It worked treatment plant well and was suitable for effluent water standard as well. Because COD removal efficiency was 42% in A-stage, 71% in B-stage and the total removal efficiency was 94% COD control was possible in effluent water quality. 2. Treatment efficiency according to a load capacity was average 20% in 1.401 BOD kg/m3/d load of A-Stage and average 90% in 0.273 BOD kg/$\textrm {m}^3$ / d load of B-Stage. 3. Treatment efficiency according to a ratio of F/M was 2.657--5.024 kg BOD/kg MLSS/d in A-Stage and BOD removal efficiency was 16-261 in the same stage. The ratio of F/M was 0.068-0.094 kg BOD /kg MLSS/d and BOD removal efficiency ratio was 85-94%. Therefore treatment efficiency could be kept stably and volume of aeration tank could be reduced wholly. 4. Treatment efficiency according to MLSS appeared BOD 20%. COD 42%, in A-Stage and removal efficiency appeared BOD 90%, COD 71% in B-Stage. They were suitable for plan condition. 5. Because of working of complemented treatment plant by AB-Process. 20,000,000 Won a month was saved than the ordinary working cost. Therefore, it was assumed that invested cost could be recollected in 19 months or so consequently.

  • PDF

Removal of Suspended Solids and Nitrification by Floating Bead Filter in Recirculating Aquaculture System (Floating Bead Filter에 의한 순환여과식 양식장의 부유고형물 제거와 질산화)

  • KIM Byong Jin;KIM Sung Koo;SUH Kuen Hack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.2
    • /
    • pp.163-169
    • /
    • 2003
  • The floating bead filter was tested for treatment of aquacultural water in a pilot-scale recirculating aquaculture system. Performance of floating bead filter on the removal of total suspended solids (TSS) and the treatment of nitrogen sourer such as total ammonia nitrogen (TAN), nitrite nitrogen and nitrate nitrogen were evaluated. The system was stocked with Nile tilapia at an initial rearing densities of $5\%\;and\;7\%$ over 30 days. The average TSS removal rates were $43.0\;g/m^2{\cdot}day\;and\;39.5\;g/m^2{\cdot}day$ for rearing density of $5\%\;and\;7\%$, respectively. As rearing density increased from $5\%\;to\;7\%$. the TAN removal efficiency decreased from $22.0\%\;to\;17.7\%$. At the rearing densities of $5\%\;and\;7\%$, the average TAN removal rates and removal efficiencies were $38.8\;g/m^2{\cdot}day,\;15.6\%\;and\;37.8\;g/m^2{\cdot}day.\;17.7\%,$ respectively. The average TAN removal rate was $37.8-38.8\;g/m^3{\cdot}day.$ The oxygen consumption by floating bead filter was higher than theoretical oxygen consumption rate by nitrification.

A Vegetation Purification System for Water Quality Improvement in Irrigation Reservoirs (저수지 수질개선을 위한 식생정화시스템)

  • 박병흔
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.4
    • /
    • pp.87-95
    • /
    • 2000
  • A vegetation purification system was applied to improve water quality of Masan Reservoir in Korea, which was composed of constructed wetlands in series. Five different kinds of macrophytes were planted in each wetland. The system was operated with the condition of low concentrations and high hydraulic loadings. Removal efficiencies(%) of chemical oxygen demand(COD) , total nitrogen(T-N) and total phosphorus(T-P) in this system were 9.0, 12.8, 20.1% , respectively. and removal rates(g/$m^2$/d) were 1.9(COD), 0.34(T-N) and 0.05(T-P) . Comparing this system with other wetlands operated at low hydraulic loadings, average removal efficiencies were low but removal rates were relatively high. Accordingly, this system could be applied to imporve reservoir water quality, because removal rates are more important than removal efficiencies in case of reservoir water quality improvement . However, the removal efficiencies and rates of this system are less than those of the hydroponic biofilter method which is a kind of a constructed wetland and utilize root zones of emergent macrophytes for trapping pollutants. Therefore, it is recommended that this system should be modified to utilize root zones of emergent macrophytes enough to improve reservoir water quality more efficiently.

  • PDF

Improved Coagulant for High Efficiency Phosphorus Removal in Secondary Effluent of Waste Water Treatment Plant (하수처리장 2차 처리수의 고효율 인 제거를 위한 응집제 개선)

  • Choi, Jeung-seung;Lee, Byung-ha;Kim, Ki-pal;Baek, Dae-jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.683-690
    • /
    • 2016
  • Modified coagulants were investigated for the removal of phosphorus from secondary effluent of wastewater treatment. The modified coagulants were prepared by mixing alkali earth metal ions such as calcium and magnesium. The basicity of a coagulant influenced on the removal of phosphorus, and coagulants with basicity of 5.9% showed a better removal of total phosphorus than that of 38.5%. Also, coagulants with alkali earth metals enhanced the performance of coagulation by 10% and resulted in 67.1% for total phosphorus removal. Moreover, the removal of suspended solids and chemical oxygen demand was improved using coagulants with low basicity and earth metal ions. Results of this study demonstrated that the use of coagulants with low basicity, and calcium and magnesium ions is recommended to improve wastewater effluent quality.