• Title/Summary/Keyword: Total removal

Search Result 1,863, Processing Time 0.023 seconds

A Study on The Effectiveness of Watertreatment Using Activated Carbons and Membranes (활성탄과 Membrane을 이용한 수처리효과에 관한연구)

  • 김영진;김영규;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.67-72
    • /
    • 1997
  • To evaluate the effectiveness of water treatment using nanofiltration, ultrafiltration, and microfiltration systems, tapwater contaminated by bacteria and nitrate nitrogen was filtered, and then the rates of removal for many kinds of contaminants were comp.ared and investigated. The rates of turbidity removal by these systems are around 80% all of them. However, nanofiltration system is the most effective as hardness removal is 80%, suspended solids 90%, total residual chlorine 90% and nitrate nitrogen 69%. Among nanofiltration, ultrafiltration and microfiltration systems, nanofiltration system is the most stable in flow rate of permeate. Comparing hollow and spiral type of ultrafiltration, microfiltration each, spiral type is more stable than hollow type owing to rinsing effect of brine. The values of pH in ultrafiltration and microfiltration systems are between 7, 0 and 7.5, and that of nanofiltration system is low to 6.2-7.0. The effectiveness of heterotrophic bacteria removal is the most excellent in the nanofiltration system.

  • PDF

Optimal Conditions for Mist Sensing and Removal in Automobile (자동차 내부의 김서림 감지 및 제거를 위한 최적의 조건)

  • You, Do-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.763-769
    • /
    • 2012
  • For mist sensing, temperature-humidity sensor is attached on six positions of front glass and rearview mirror in automobile. Bottom-left side of front glass is the best position where mist is sensing. For mist removal, air conditioner is turned on intensity 1, 3 and is set the temperature at 17[$^{\circ}C$], 25[$^{\circ}C$]. And heater is turned on intensity 1, 3 and is set the temperature at 25[$^{\circ}C$], 32[$^{\circ}C$]. The best condition which mist is removed is temperature at 17[$^{\circ}C$] and intensity 3 of air conditioner mode. At this condition, total average value of humidity output voltage difference is 0.561[V]. Also, air conditioner mode is effective than heater mode for mist sensing and removal.

Waste treatment with the pilot scale ATAD and EGSB pig slurry management system followed by sequencing batch treatment

  • Lee, Young-Shin;Han, Gee-Bong
    • Environmental Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.277-284
    • /
    • 2015
  • Experiments for highly concentrated contaminants in pig waste slurry were carried out for the feasibility test of a pilot-scale innovative process scheme of engaging autothermal thermophilic aerobic digestion (ATAD) and expended granular sludge bed (EGSB) followed by sequencing batch reactor (SBR) system. Contaminants in pig waste slurry such as organic substance, total nitrogen (TN), ammonia nitrogen and total phosphorus (TP) contents were successfully reduced in the system. Total volatile solids (TVS) and chemical oxygen demands (COD) for organic matter in the feed were 32.92 g/L and 42.55 g/L respectively, and they were reduced by about 98.7% and 99.2%, respectively in the system. The overall removal efficiencies for TN and ammonium nitrogen were found to be 98.1 and 98.5%, respectively. The overall removal efficiency for total phosphorus was also found to be 92.5%. Faecal coliform density was reduced to <$1.2{\times}10^4CFU/g$ total solids. Biogas and $CH_4$ were produced in the range of 0.39-0.85 and $0.25-0.62m^3/kg$ [VS removed], respectively. The biogas produced in the system comprised of $295{\pm}26ppm$ (v/v) [$H_2S$].

Intracranial Chordomas and Chondrosarcomas : The Effectiveness of Surgery and Radiation Therapy (두개강내 척삭종 및 연골육종 : 수술 및 방사선 치료의 효능)

  • Chung, Young-Seob;Gwak, Ho-Shin;Jung, Hee-Won;Park, Hong-Jun;Paek, Sun Ha;Kim, Dong Gyu;Kim, Hyun Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.7
    • /
    • pp.910-917
    • /
    • 2000
  • Introduction : The management of chordomas and chondrosarcomas in the skull base is difficult due to the critical location, locally aggressive nature, and high recurrence rate. The authors present the effectiveness of surgical removal and radiation therapy on survival and tumor recurrence. Material and Methods : Thirty cranial base chordomas and chondrosarcomas from 23 patients(14 patients with chordomas and 9 patients with chondrosarcomas) were operated in our institution between 1985 and 1998. There were 15 men and 8 women, with a mean age of 40.7 years. The largest diameter of tumors ranged from 15 to 70mm (mean 41.5). The extent of surgical removal was subtotal or total in a half(15 operations). In nineteen operations, tumors were removed by conventional approaches and skull base approaches were applied in 11 operations. Postoperative radiation therapy was performed in 16(70%) patients. The mean duration of follow up is 50 months(1- 156 months). Results : The 3- and 5-year survival rates(YSR) of overall patient are 75% and 67%, respectively. The analysis showed that 1) skull base approach to chordomas and chondrosarcomas showed a tendency to remove more portion of the tumors(p=0.058) but leave more frequent incidence of new deficits(p=0.047) : 2) larger tumor diameter af-fected the extent of removal(p=0.028) : 3) the extent of removal seemed to be the determining factor for overall survival and recurrence-free survival(the 5-YSR and RFSR of subtotal or total removal group are 92% and 80% vs. 40% of partial removal or biopsy group) : 4) conventional radiation therapy improved patient survival(5-YSR of patients who received RT is 76% whereas 5-YSR of those who didn't receive RT is 43%) but failed to prolong long-term recurrence-free survival. Conclusion : The extent of removal and postoperative radiation therapy are determining factors of patients' survival in skull base chordomas and chondrosarcomas. However, none of these factors significantly influenced the survival in multivariate analysis. Aggressive surgical removal of more than subtotal resection combined with postoperative radiation therapy seems to be the choice of therapy in the management of these tumors.

  • PDF

The Effect of the Formaldehyde Removal of Fore Temperate Ground Cover Plants (4가지 온대성 지피식물의 실내 포름알데이드 제거효과)

  • Ju, Jin-Hee;Bang, Kwang-Ja;Lee, Jin-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.2 s.121
    • /
    • pp.49-54
    • /
    • 2007
  • This research was performed to investigate the effect of formaldehyde removal and confirm the utility of plants as indoor environment improvement systems. The plant materials used in this study were Fatsia japonica, Ardisia japonica, Ardisia pusilla and Davallia mariesii. Plants were placed in an airtight chamber under artificial formaldehyde. The initial formaldehyde concentration in the chamber was $500{\pm}30ppb$, and the conditions of $1,500{\sim}2,000lux$ light, $25{\pm}5^{\circ}C$ temperature and $80{\sim}90%$ humidity were maintained. Each chamber was treated as no plant, plant-only and Plant+soil. The total leaf number for Davallia mariesii, Ardisia japonica, Ardisia pusilla, and Fatsia japonica was 40.8, 48.6, 62.3, and 11.8 respectively. The total leaf space n of those plant materials were $2,385cm^2,\;1,252cm^2,\;2,468cm^2\;and\;1,262cm^2$ respectively. The formaldehyde concentration was reduced to $80{\sim}90%$ of the initial concentration in plant-only and Plant+Soil treatment chamber of all species in 12 hours. In the plant-only chamber, Fatsia japonica had removed formaldehyde density by 95% after 12 hours while Ardisia japonica had removed 90%. In the case of Ardisia pusilla, the early removal rate was higher in the plant-only treatment chamber than the Plant+Soil treatment chamber. The formaldehyde removal rate of Davallia mariesii was 98% after 12 hours. In the Plant+Soil treatment chamber, the amount of removal of formaldehyde per time of Davallia mariesii, Ardisia japonica, Ardisia pusilla, and Fatsia japonica was 20.42ppb/hr, 16.28ppb/hr, 2.5.42ppb/hr, 10.28ppb/hr respectively. In the plant-only, That was 22.50ppb/hr, 20.97ppb/hr, 20.83ppb/hr, 20.97ppb/hr respectively.

Water Treatment Using Constructed Wetlands and Research Perspectives in Korea (인공습지를 이용한 수처리 효율 및 향후 연구제언)

  • Gang, Ho-Jeong;Song, Geun-Ye
    • Journal of Wetlands Research
    • /
    • v.6 no.2
    • /
    • pp.57-63
    • /
    • 2004
  • More than 1000 natural and constructed wetlands have been used to improve water quality. The general results showed that the highest removal efficiency was 84% for BOD and the lowest one was 48% for total nitrogen concentration. In addition, total phosphous removal efficiency was 67%, and the removal efficiencies are related to inflow loading. Researches donducted in Korea have focused on input-output mass balance and uptake by aquatic plant. As such little information if available about complex processes regulating water quality and role of microbes. Therefore, to determine the optimal design for construct, and methods to operate constructed wetland, researches about complex mechanisms of contaminant removal and interdisciplinary researches are necessary.

  • PDF

Microbial Community Analysis of 5-Stage Biological Nutrient Removal Process with Step Feed System

  • Park, Jong-Bok;Lee, Han-Woong;Lee, Soo-Youn;Lee, Jung-Ok;Bang, Iel-Soo;Park, Eui-So;Park, Doo-Hyun;Park, Yong-Keun
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.6
    • /
    • pp.929-935
    • /
    • 2002
  • The 5-stage biological nutrient removal (BNR) process with step feed system showed a very stable organic carbon and nutrient removal efficiency ($87\%\;COD\,;79\%\;nitrogen,\;and\;87\%$ phosphorus) for an operation period of 2 years. In each stage at the pilot plant, microbial communities, which are important in removing nitrogen and phosphorus, were investigated using fluorescence in-situ hybridization (FISH) and 165 rDNA characterization. All tanks of 5-stage sludge had a similar composition of bacterial communities. The totat cell numbers of each reactor were found to be around $2.36-2.83{\times}10^9$ cells/ml. About $56.5-62.0\%$ of total 4,6-diamidino-2-phenylindol (DAPI) cells were hybridized to the bacterial-specific probe EUB388. Members of ${\beta}$-proteobacteria were the most abundant proteobacterial group, accounting for up to $20.6-26.7\%$. The high G+C Gram-positive bacterial group and Cytophaga-Flexibacter cluster counts were also found to be relatively high. The beta subclass proteobacteria did not accumulate a large amount of polyphosphate. The proportion of phosphorus-accumulating organisms (PAOs) in the total population of the sludge was almost $50\%$ in anoxic-1 tank. The high G+C Gram-positive bacteria and Cytophaga-Flexibacter cluster indicate a key role of denitrifying phosphorus-accumulating organisms (dPAOs). Both groups might be correlated with some other subclass of proteobacteria for enhancing nitrogen and phosphorus removal in this process.

Removal of Nutrients Using an Upflow Septic Tank(UST) - Aerobic Filter(AF) System (부패조와 호기성 여과공정을 이용한 영양염류 제거)

  • Park, Sang-Min;Jun, Hang-Bae; Bae, Jong-Hun;Park, Woo-Kyun;Park, Noh-Back
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.3
    • /
    • pp.232-238
    • /
    • 2010
  • The objective of this study was to investigate a small sewage treatment system. This system was developed to improve a nitrogen and phosphorus removal efficiency and generate less solid using upflow septic tank(UST) - aerobic filter(AF) system. The UST equipped with an aerobic filter, the filter was fed with both raw sewage and recycled effluent from the UST to induce the denitrification and solid reduction simultaneously. Overall removal efficiencies of COD and total nitrogen(TN) were above 96% and 73% at recycle ratio of 200%, respectively. Critical coagulant dose without the biochemical activity was found to be 40 mg/L. Removal efficiency of total phosphorus(TP) in influent was above 90% by chemical and biological reactions. Although the phosphorus concentration was low under the high alkalinity in raw sewage, the pH value was unchanged by the coagulant dose.

Characteristics of Natural Organic Matter (NOM) on Han River and Criterion of Enhanced Coagulation (한강원수 자연유기물의 특성분석 및 강화응집 기준 평가)

  • Jeong, Youngmi;Kweon, Jihyang;Lee, Sanghyup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.653-661
    • /
    • 2007
  • The Disinfectants/Disinfection By-products (D/DBP) Rule proposed by the US Environmental Protection Agency requires the implementation of enhanced coagulation as a control strategy for natural organic matter (NOM) removal and as a means of limiting the formation of all DBPs, i.e., not just the trihalomethanes and haloacetica acids. To control DBP formation, several best available technologies (BATs) were determined for removal of DBPs and DBP precursors. The enhanced coagulation is one of the BATs for DBP precursors removal. Treatment facilities that achieve a specified percent removal of total organic carbon (TOC) prior to the application of a continuous disinfectant or that achieve a residual TOC concentration < 2mg/L prior to the application of a continuous disinfectant are considered to be in compliance with enhanced coagulation. The enhanced coagulation was applied to raw water in Korea, the Han River. Raw water were examined and effects of different raw water qualities on enhanced coagulation were investigated. Three analyses were used for raw water characteristics, water quality measurement, molecular weight distributions, hydrophobic/hydrophilic fractionation. The Han River had the relatively low alkalinity and low organic carbon concentration. The results of molecular weight distributions showed significant portions of low molecular weight organics, which is very different from most water in USA. The alum doses for the required TOC removal guided from USEPA manual were quite low (i.e. 10~30 mg/L alum) for the water, probably due to the specific water quality of the Han River.

Characterization of Humic Acid in the Chemical Oxidation Technology(I) - Characteristics by Photocatalytic Oxidation Process - (화학적 산화법에 의한 부식산의 분해 처리기술에 관한 연구(I) - 광산화공정을 통한 부식산의 분해특성 분석 -)

  • Kim, Jong Boo;Rhee, Dong Seok
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.234-240
    • /
    • 2000
  • The efficiency of Photocatalytic Oxidation Process were investigated for the treatment of Aquatic Humic Substances (AHS). In UV-only system, pH 7-9 was the optimum pH range for TOC removal, and alkali range was the optimum pH for absorbance decrease. In UV/$TiO_2$ system, the optimum $TiO_2$ dosage was 50ppm and over 50ppm of $TiO_2$ dosage was not effective for removal of AHS. In UV/$H_2O_2$ system, optimum $H_2O_2$ dosage was 20mM, when over 20mM dosage, removal of TOC (Total Organic Carbon) and absorbance was decreased. Radical scavenger affected on the photo-oxidation of AHS. Removal rate of TOC and absorbance was decreased by addition of carbonate ions and TOC removal was more effected than that of absorbance.

  • PDF