• 제목/요약/키워드: Total radiation flux

검색결과 60건 처리시간 0.026초

RCP 시나리오에 따른 미래 동아시아 지표복사에너지와 운량 변화 전망 (Future Changes in Surface Radiation and Cloud Amount over East Asia under RCP Scenarios)

  • 이철;부경온;심성보;변영화
    • 한국기후변화학회지
    • /
    • 제7권4호
    • /
    • pp.433-442
    • /
    • 2016
  • In this study, we examine future changes in surface radiation associated with cloud amount and aerosol emission over East Asia. Data in this study is HadGEM2-CC (Hadley Centre Global Environmental Model version 2, Carbon Cycle) simulations of the Representative Concentration Pathways (RCPs) 2.6/4.5/8.5. Results show that temperature and precipitation increase with rising of the atmosphere $CO_2$. At the end of $21^{st}$ century (2070~2099) relative to the end of $20^{st}$ century (1981~2005), changes in temperature and precipitation rate are expected to increase by $+1.85^{\circ}C/+6.6%$ for RCP2.6, $+3.09^{\circ}C/+8.5%$ for RCP4.5, $+5.49^{\circ}C/10%$ for RCP8.5. The warming results from increasing Net Down Surface Long Wave Radiation Flux (LW) and Net Down Surface Short Wave Radiation Flux (SW) as well. SW change increases mainly from reduced total Aerosol Optical Depth (AOD) and low-level cloud amount. LW change is associated with increasing of atmospheric $CO_2$ and total cloud amount, since increasing cloud amounts are related to absorb LW radiation and remit the energy toward the surface. The enhancement of precipitation is attributed by increasing of high-level cloud amount. Such climate conditions are favorable for vegetation growth and extension. Expansion of C3 grass and shrub is distinct over East Asia, inducing large latent heat flux increment.

Effects of radiation-modulated cooling on the momentum transfer from stellar feedback

  • Na, Chongsam;Kimm, Taysun
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.70.2-70.2
    • /
    • 2019
  • Strong radiation fields can change the ionization state of metals and hence cooling rates. In order to understand their effects on the momentum transfer from radiation and supernova feedback, we perform a suite of radiation-hydrodynamic simulations with radiation-modulated metal cooling. For this purpose, we pre-tabulate the metal cooling rates for a variety of spectral shapes and flux levels with the spectral synthesis code, Cloudy, and accurately determine the rates based on the local radiation field strength. We find that the inclusion of the radiation-modulated metal cooling decreases the total radial momentum produced by photo-ionization heating by a factor of ~3 due to enhanced cooling at temperature T~10^3-4 K. The amount of momentum transferred from the subsequent SN explosions, however, turns out to be little affected by radiation, as the main cooling agents at T~10^5-6 K are only destroyed by soft X-ray radiation which is generally weak. We further discuss the total momentum budget in various conditions.

  • PDF

태양열 집광기의 플럭스 밀도 분포 특성에 관한 연구 (An Experimental Study on the Characteristics of Flux Density Distributions produced by Solar Concentrating System)

  • 강명철;강용혁;윤환기;유창균
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.422-426
    • /
    • 2005
  • This experimental study represents the results of an analysis on the characteristics of flux density distribution in the focal region of solar concentrator. The characteristics of flux density distributions are investigated to optimally design and position a cavity receiver. This was deemed very useful to find and correct various errors associated with a dish concentrator. We estimated the flux density distribution on the target placed along with focal lengths from the dish vertex to experimentally determine the focal length. It is observed that the actual focal point exists when the focal length is 2.17m. The total integrated power and percent power was 2467W and $85.8\%$, respectively, in the case of small dish, and also 2095W and $79\%$, respectively, in the case of KIERDISH II. As a result of the percent power within radius, approximately $90\%$ of the incident radiation is intercepted by about 0.06 m radius. The minimum radius of receiver in KIERDISH II is found to be 0.15m and approximately $90\%$ of the incident radiation is intercepted by receiver aperture.

  • PDF

남극 세종기지의 에너지 평형 (Surface Energy Balance at Sejong Station, King George Island, Antarctica)

  • 김준;조희구;정연진;이윤곤;이방용
    • 대기
    • /
    • 제16권2호
    • /
    • pp.111-124
    • /
    • 2006
  • This study examines seasonal variability of the surface energy balance at the King Sejong Station, Antarctica, using measurements and estimates of the components related to the balance for the period of 1996 to 2004. Annual average of downward shortwave radiation at the surface is 81 $Wm^{-2}$ which is 37% of the extraterrestrial value, with the monthly maximum of 188 $Wm^{-2}$ in December and the minimum of 8 $Wm^{-2}$ in June. These values are relatively smaller than those at other stations in Antarctica, which can be attributed to higher cloudy weather conditions in Antarctic front zone. Surface albedo varies between ~0.3 in the austral summer season and ~0.6 in the winter season. As a result, the net shortwave radiation ranges from 117 $Wm^{-2}$ down to 3 $Wm^{-2}$ with annual averages of 43 $Wm^{-2}$. Annual average of the downward longwave radiation shows 278 $Wm^{-2}$, ranging from 263 $Wm^{-2}$ in August to 298 $Wm^{-2}$ in January. The downward longwave radiation is verified to be dependent strongly on the air temperature and specific humidity, accounting for 74% and 79% of the total variance in the longwave radiation, respectively. The net longwave radiation varies between 25 $Wm^{-2}$ and 40 $Wm^{-2}$ with the annual averages of 30 $Wm^{-2}$. Accordingly, the annual average energy balance is dominated by radiative warming of a positive net all-wave radiation from September to next March and radiative cooling of a negative net all-wave radiation from April to August. The net all-wave radiative energy gain and loss at the surface is mostly balanced by turbulent flux of sensible and latent heat. The soil heat flux is of negligible importance in the surface energy balance.

KIER 태양로의 열유속 분포 특성 (Characteristic of the Radiation Heat Flux Distribution for the KIER Solar Furnace)

  • 채관교;이현진;김종규;윤환기;이상남;강용혁;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.74-79
    • /
    • 2011
  • Concentration characteristics of the KIER solar furnace are analyzed with a heat flux measurement technique. Total heat capacity of 40kW was confirmed within 1.04% average error, and the normalized maximum heat flux of 3,452 $kW/m^2$ was proved. Non-Gaussian flux distribution in the vertical direction implies that reflectors should not be random rather inclined downwards. Moreover, we characterized flux distribution variations with furnace blind opening ratio, distance from the focal plane, and misalignment of the measurement system. Based on the results, the heat flux distribution can be simply estimated once reflectivity and direct normal insolation values are known. This study will be helpful to the design and the performance evaluation of receivers or chemical reactors.

  • PDF

LED광원에 의한 회화 전색제의 변색 영향 연구 (Discoloration Effects of LEDs on Painting Binder Materials)

  • 김지원;이유정;김규린;이화수;강대일
    • 보존과학회지
    • /
    • 제34권2호
    • /
    • pp.77-85
    • /
    • 2018
  • 유물에 대한 조명의 변색 영향을 파악하기 위해서는 유물을 구성하는 재질에 대한 빛의 반응특성을 우선 분석하여야 한다. 본 연구에서는 회화유물의 채색층을 구성하는 대표적인 전색제인 동물성 아교와 린시드유를 대상으로 하였으며, 파장 특성이 다른 White LED와 Blue LED 조명을 사용한 가속열화실험을 통해 변색 영향 정도를 확인하였다. 실험 결과, 동물성 아교 및 린시드유는 Blue LED 조명을 사용한 가속열화실험 조건에서 변색이 두드러지게 나타났으며, 두 종류의 LED 조명 중에서 전복사속(mW) 값이 큰 Blue LED에서 재질 변색 정도가 크게 나타났다. 이상의 결과로, 동물성 아교 및 린시드유 등 회화유물 전색제의 변색에 미치는 광원의 영향은 전광선속(lm)보다 전복사속(mW)이 주요하게 작용함을 파악하였다.

단일액적연소현상에서 비회색체복사에 관한 연구 (Investigation of a droplet combustion with nongray gas radiation effects)

  • 최창은;박재현;박승욱
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1363-1370
    • /
    • 1997
  • Single liquid droplet combustion processes including heating, evaporation, droplet burning and flame radiation were theoretically investigated by adopting nongray gas radiation model for the radiative transfer equation (RTE). n-Heptane was chosen as a fuel and the numerical results were compared with the experimental data available in the literature. The discrete ordinate method (DOM) was employed to solve the radiative transfer equation and the weighted sum of gray gases model (WSGGM) was applied to account for nongray effect by CO$_{2}$, and H$_{2}$0. Therefore, detailed effects by nongray gas and its comparison with the gray gas model could be figured out in the results. It is found that the radiative heat flux is higher when the nongray model is used, thereby reducing the maximum gas temperature and the flame thickness, but the total burning time increases due to the deceased conductive heat flux in nongray model. Consequently, a better agreement with experimental data could be obtained by using nongray model.

기상조건에 따른 온실의 전천일사량 및 광합성유효광량자속의 상관관계 및 투과율 (Relationship between Total Solar Radiation and PPF, and Transmittance in Greenhouse at Different Weather Conditions)

  • 이현우;이석건;이상호
    • 생물환경조절학회지
    • /
    • 제11권2호
    • /
    • pp.56-60
    • /
    • 2002
  • 온실의 경우 구조재가 광투과율에 많은 영향을 주기 때문에 기상조건에 따라 달라지는 산란광과 직달광의 비율에 따라 투과율이 달라질 수 있다 따라서 기상조건에 따른 온실내부의 광투과율을 구명할 필요가있다. 전천일사량은 기상청에서 제공하는 기상자료에서 쉽게 얻을 수가 있는 반면에 광합성유효광량자속의 자료는 직접 측정하지 않고는 구하기가 어렵다. 그러나 전천일사량과 광합성유효광량자속의 상관관계가 얻어지면 전천일사량으로부터 광합성유효광량자속을 쉽게 구할 수가 있을 것이다. 따라서 우리나라 온실에 대하여 기상조건에 따라 광합성유효광양자속을 산정할 수 있는 상관식의 개발이 필요하다. 본 연구는 실험을 통하여 온실의 수관부에서의 기상조건에 따른 광합성유효광량자속의 투과율을 산정하고 전천일사와 광합성 유효광량자속과의 상관관계를 구명하기 위하여 수행되었다. 산란광이 많은 흐린 날과 직달광이 많은 맑은날의 투과율 변화는 상당한 차이가 있음을 확인할 수 있었으며, 온실의 투과율은 기상조건에 따라 다르게 적용되어야 할 것으로 판단되었다. 온실의 전천일사량 투과율을 광합성유효광량자속의 투과량을 산정하는데 그대로 이용할 수 있을 것으로 분석되었다. 비록 맑은 날에 비하여 흐린 날의 상관도는 낮지만 상관식의 기울기는 큰 것으로 나타나 운량의 증가와 더불어 전천일사량 중에서 광합성유효광량자속의 비율이 증가하는 것을 확인 할 수 있었다. 시간당 광합성유효광량자속과 전천일사량의 상관식을 유도하였으며, 이러한 상관식을 이용한다면 시간당 전천일사량을 이용하여 시간당 광합성유효광량자속을 추정하는데 적절히 이용할 수 있을 것으로 판단된다.

KOREAN VLBI NETWORK CALIBRATOR SURVEY (KVNCS): 1. SINGLE DISH FLUX MEASUREMENT IN THE K AND Q BANDS

  • Lee, Jeong Ae;Sohn, Bong Won;Jung, Taehyun;Byun, Do-Young;Lee, Jee Won
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.32.2-32.2
    • /
    • 2016
  • We present the catalog of the KVN Calibrator Survey (KVNCS). This first part of the KVNCS is a single dish radio survey conducted at 22 (K band) and 43 GHz (Q band) simultaneously using the Korean VLBI Network (KVN) from 2009 to 2011. A total 2045 sources selected from the VLBA Calibrator Survey (VCS) with an extrapolated flux limit of 100 mJy at K band. The KVNCS contains 1533 sources in the K band with a flux limit of 70 mJy and 553 sources in the Q band with a flux limit of 120 mJy; it covers the whole sky down to -32. ${\circ}$ 5 in declination. Five hundred thirteen sources were detected in the K and Q bands, simultaneously; ~76% of them are flat-spectrum sources ($-0.5{\leq}{\alpha}{\leq}0.5$). From the flux-flux relationship, we anticipated that the most of the radiation of many of the sources comes from the compact components. Therefore, the sources listed in the KVNCS are strong candidates for high frequency VLBI calibrators.

  • PDF

접시형 태양열 집광 시스템의 에너지 분포 특성에 관한 연구 (A Study on Energy Distributions Produced by Dish Solar Concentrating System)

  • 현성택;강용혁;천원기
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.907-913
    • /
    • 2002
  • An experimental study on energy density distributions produced by dish solar concentrating system was performed to optimally design and rightly position a cavity receiver. This deemed also very useful to find and correct various errors associated with a concentrator. It is observed that the actual focal length is 2.17 m with a maximum energy density of 1.89 MW/$m^2$. By evaluating the position of flux centroid, it was found that there are errors within 2 cm from the target center. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06 m radius. The area concentration ratio normalized to 800 W/$m^2$ insolation and 90% mirror reflectivity was 347 suns. The total integrated power of 2467 W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%.