• 제목/요약/키워드: Total pressure recovery

검색결과 140건 처리시간 0.027초

젖소의 초음파 유도 채란율에 대한 FSH 전처리 효과의 비교 (Effect of FSH Pretreatment on Follicle Development and Oocyte Recovery by Ultrasound-guided Aspiration in Holstein Heifers)

  • 박충생;조성근;이정규;강태영;박성재;공일근;최민철
    • 한국가축번식학회지
    • /
    • 제21권2호
    • /
    • pp.147-156
    • /
    • 1997
  • Ultrasound-guided follicular aspiration was performed in Holstein heifers once weekly with or without pretreatment of single or multiple decreasing doses using a total of 400 mg FSH. Oocytes were aspirated with a 6.5 MHz convex-array ultrasound trasducer designed for intravaginal use. All the visible follicles larger than 4 mm in diameter were punctured with a 17 gauge, 55 cm needle at each aspiration session and the follicular fluids containing oocytes were obtained by vacuum suction. The results obtained were as follows: As a preliminary experiment, the recovery rates of folicular oocytes by ultrasound-guided aspiration from the isolated ovaries of Korean native cows were compared between suction methods using manual syringe or vacuum pump. The recovery rate of oocytes using vacuum pump (80.7%) was significantly (P<0.05) higher than that using manual syringe (47.1%). The follicles were counted by their size in diameter with ultrasound image, and recovery rates and grades of follicular oocytes collected by ultrasound-guided aspiration were investigated in Holstein heifers pretreated with or without FSH. A group of heifiers were injected with multiple decreasing doses (twice a day for 3 days) of a total of 400 mg FSH. The other 2 groups were injected with a single dose of 400 mg FSH mixed with 25% PVP. Ultrasound observation of follicle population and/or ultrasound-guided transvaginal oocyte aspiration were performed 12 hrs following the last FSH injection in the multiple dose group, and 48 or 60 hrs after FSH injection in the single dose groups. Most of the visible follicles had small size of less than 3 mm in diameter in unstimulated heifers (71.0%), but medium size in all the heifers treated with FSH. (70.5 to 92.8%). The number of OPU follicles per session (4.6$\pm$1.9) were much less, compared to the vilsible follicle counts (9.7$\pm$2.2), in the nustimulated heifers due to the small dominant follicles. Among 4 goups of heifers the most visible as well as OPU follicles were observed in the heifers at 60 hrs following treatment of a single dose of 400 mg FSH (21.2$\pm$2.3 and 21.0$\pm$2.0), and the differences in both the follicle counts between the groups was found significant (P<0.05) The rates of oocyte recovery from the follicles by ultrasound-guilded aspiration were varied 46.3 to 75.0% in the heifers unstimulated and treated with a single dose of 400 mg FSH, but the group difference was not significant. The number of recovered oocytes per session a, pp.ared to be highest at aspiration at 60 hrs following single FSH (10.6$\pm$2.2) than at aspiration at 48 hrs after single FSH (7.8$\pm$2.7) or in the unstimulated heifers (3.4$\pm$3.0). The proportion of grade I and II oocytes to all oocytes collected was varied 31.8 to 64.0% between the groups. However, there was found no significant difference in both the number of oocytes recovered per session and the percentage and the percentage of grade I and II oocytes. From the above results it was concluded that the more oocytes of superior quality might be recovered economically by ultrasound-guided aspiration at 60 hrs following the pretreatment of a single dose of 400 mg FSH and by suction using a vacuum pump system of about negative pressure of 75 to 85 mmHg.

  • PDF

인공호흡기 사용 신생아의 폐쇄형과 개방형 기관흡인에 관한 연구 (A Comparative Study on Closed vs. Open Endotracheal Suctioning on the Newborn Infants Treated with Ventilator)

  • 박정원;박영애
    • 아동간호학회:학술대회논문집
    • /
    • 아동간호학회 1997년도 정기총회 및 학술대회
    • /
    • pp.61-74
    • /
    • 1997
  • Endotracheal suctioning is a routine procedure used for clearing secretions from the airway of the intubated infant. This procedure is not without complications. Endotracheal suctioning has been associated with decreases in $PaO_2$, decreases in systemic venous oxygenation, alterations in mean arterial Pressure, disturbances in cardiac rhythm and development of nosocomial pneumonia. So several endotracheal suctioning techniques have been developed to prevent these blown complications. Another method of Endotracheal suctioning eliminates the risk associated with disconnecting the infant from the ventilatior to perform the suctioning procedure. Studies examining closed endotracheal suctioning methods reported that the closed method results in less arterial oxygen saturation, and less systemic venous oxygen desaturation. However those studies have focused on adult patients, and there have been no published studies for newborn infants. The specific purpose of this study is to investigate the two methods and to make a comparison in terms of (1)variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning; (2)difference in occurrence of nosocomial infection; (3)difference in recovery time to arrive at pre-suction baseline after suctioning and in nursing time taken for the suctioning. The present study is based on the data obtained from two groups of newborn infants : one group comprises 8 infants with closed suctioning (a total of 304 suctions) among 17 infants treated with ventilator and the other group 9 infants with open method (a total of 629 suctions). The data were analyzed using the SPSS statistical program package. As the distribution test on dependent variables with the Skewnesser Shapiro Wilk test showed an asymmetric distribution, the Wilcoxon Matched-pairs Singled- Ranks test was used for the test of variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning. The difference in $SaO_2$ recovery time and nursing time was analyzed with the Mann-Whitney U-Test. The difference in physiologic consequences and occurrence of nosocomial infection between the two groups was analyzed with the Fisher's Exact Test. The results of the study are summarized as follows. For the hypothesis 1 (There would be a difference in $SaO_2$, heart rate, and respiration rate before and after suctioning between the two suctioning methods), the difference in $SaO_2$ turns out to be statistically significant (P=0.015), but heart rate and respiration rate do not procedure a notable difference (P=0.630). The hypothesis 2 (There would be a difference in rates at which a complication arises after suctioning between the two groups) does not prove to be statistically valid (P=0.246). For the hypothesis 3(There would be a difference in $SaO_2$ recovery time and nursing time between the two groups), the average $SaO_2$ recovery time after suctioning turned out to have somewhat significant difference (P=0.064), however the difference in nursing time taken for the suctioning was not statistically significant (P=0.610). The analyses indicate that the closed endotracheal suctioning is more efficient as compared with the open method, in maintaining pre-suction baseline $SaO_2$ and a rapid recovery of newborn infants. Based on these results we suggust to apply the closed method to newborn infants in the ventilation treatment. We also suggest to extend the investigation to include the comparison of suction cost taking into account the case in which a complication arises after endotracheal suctioning between the two groups.

  • PDF

세라믹 정밀여과막 공정을 위한 최적 약품세척 방안 (Optimum Chemical Cleaning Conditions for Ceramic Microfiltration Membrane Process)

  • 임재림;이경혁;이영주;박종율
    • 멤브레인
    • /
    • 제22권6호
    • /
    • pp.461-469
    • /
    • 2012
  • 본 연구는 Y 정수장의 세라믹 정밀여과막 공정을 위한 최적의 약품세척 조건을 도출하고자 수행되었다. 세라믹 막 공정의 전처리로 오존과 응집공정이 있는 A계열의 경우 응집공정만 있는 B계열에 비해 9배 정도 잦은 약품세척(CIP)를 실시하였다. 이는 전처리 공정의 차이로 인하여 A와 B계열의 막오염현상이 다르게 나타난 근본적인 원인 이외에 막제조업체가 제시한 CIP 방법이 부적절한 것으로 조사되었다. 즉, CIP 회복률이 보정여과유속이 아니라 보정차압을 기준으로 계산되어 과대평가되었을 뿐만 아니라 구연산이 철산화물에 의한 파울링을 효과적으로 제거하지 못했기 때문이었다. 따라서 1단계 산세척 약품종류를 달리하여 CIP 효율을 평가한 결과 황산(0.1 N)과 구연산(1%)를 혼합하여 사용한 경우 회복률이 가장 높았고, 황산(0.1 N)만을 사용한 경우 회복률이 가장 낮은 것으로 나타났다. 그러나 황산의 농도를 0.3 N로 높인 결과 산세척 효율은 증가하였으나 알칼리세척 회복률이 낮아져 총회복률은 0.1 N 황산을 사용한 것과 유사하였다. 산과 알칼리세척 순서를 바꿔서 CIP를 수행한 결과 산세척을 먼저 수행시 CIP 효율이 더 높은 것으로 나타났다.

A numerical study of scale effects on performance of a tractor type podded propeller

  • Choi, Jung-Kyu;Park, Hyoung-Gil;Kim, Hyoung-Tae
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권2호
    • /
    • pp.380-391
    • /
    • 2014
  • In this study, the scale effect on the performance of the podded propeller of tractor type is investigated. Turbulent flow computations are carried out for Reynolds numbers increasing progressively from model scale to full scale using the CFD analysis. The result of the flow calculation for model scale Reynolds numbers agrees well with that of the experiment of a large cavitation tunnel. The existing numerical analysis indicates that the performance of the podded propeller blades is mainly influenced by the advance coefficient and relatively little by the Reynolds number. However, the drag of pod housing with propeller in operation is different from that of pod housing without propeller due to the acceleration and swirl of propeller slipstream which is altered by propeller loading as well as the pressure recovery and friction according to Reynolds number, which suggests that the pod housing drag under the condition of propeller in operation is the key factor of the scale effect on the performance between model and full scale podded propellers. The so called 'drag ratio', which is the ratio of pod housing drag to total thrust of podded propeller, increases as the advance coefficient increases due to accelerated flow in the slipstream of the podded propeller. However, the increasing rate of the drag ratio reduces continuously as the Reynolds number increases from model to full scale progressively. The contribution of hydrodynamic forces, which acts on the parts composed of the pod housing with propeller operating in various loading conditions, to the thrust and the torque of the total propeller unit are presented for a range of Reynolds numbers from model to full scales.

지구 평균 질량 변화를 포함한 GRACE 중력 모델 보정 (Refinement of GRACE Gravity Model Including Earth's Mean Mass Variations)

  • 서기원;엄주영;권병두
    • 한국지구과학회지
    • /
    • 제35권7호
    • /
    • pp.537-542
    • /
    • 2014
  • GRACE는 2002년 발사된 이래로 지하수, 빙하, 해수면의 변동에 의한 지구의 질량 재배치를 관측해오고 있다. GRACE 관측으로부터 추정된 지구 중력 모델은 기압보정을 거쳐 대기 질량이 제거된 지구 표면과 그 하부의 질량 변화를 나타낸다. 그러나 대기 총 질량은 지표면과 대기 사이의 물 교환에 의해 변한다. 그 결과 GRACE 중력 모델은 구면 조화 함수의 계수 degree 0, order 0 ($C_{00}$)에 해당하는 총 대기 질량 변화에 관련된 중력 스펙트럼을 가져야 한다. 주로 계절적인 시간 척도 안에서 변하는 수증기 때문에 $C_{00}$의 변화(${\delta}C_{00}$)는 특히 해수면의 계절적 변동과 북반구와 남반구 사이의 질량 균형에 매우 중요하다. 이 결과는 ${\delta}C_{00}$가 기후변동과 관련된 대륙 규모의 질량 변화 연구에 꼭 고려되어야 함을 뜻한다.

저강도 운동프로그램이 여성노인의 운동에 대한 사회.심리적 및 신체적 요인에 미치는 효과 (The Effects of a Low Intensity Excercise Program on Psychosocial Factors of Excercise and Physical Factors in Elderly Women)

  • 남미라;김영희;안옥희;양복순
    • 지역사회간호학회지
    • /
    • 제18권3호
    • /
    • pp.373-381
    • /
    • 2007
  • Purpose: An exercise program, which was composed of motions simple and easy to follow, was developed and applied to aged women as a way to improve their health conditions. Method: To ascertain the effects of the exercise, which was conducted twice a week and 16 times in total for 8 weeks from September 10 to November 5, 2005 in two experimental groups (31 Persons) and a control group (31 persons), this study conducted quasi-experiments of nonequivalent control group pre-post test design. Data were analyzed using SPSS/PC Win 10.0, the reliability of the measuring tools using Cronbach's alpha, the verification of equivalence for general properties and dependent variables using Chi-square test and t-test, and the verification of hypotheses using t-test and ANCOVA. Results: After the exercise program. the aged women showed profitable evaluation of decisional balance, high feeling of self-efficacy as well as improved subjective awareness of health. Their diastolic blood pressure and total cholesterol were also reduced significantly after the exercise. Conclusion: After the conduct of the exercise program for 8 weeks, aged women showed increased profitable decisional balance, self-efficacy and subjective awareness of health. This suggests that continuous and proper exercise is effective as an intervention for health improvement for the aged as well as the prevention of and recovery from geriatric diseases.

  • PDF

Optimization of VIGA Process Parameters for Power Characteristics of Fe-Si-Al-P Soft Magnetic Alloy using Machine Learning

  • Sung-Min, Kim;Eun-Ji, Cha;Do-Hun, Kwon;Sung-Uk, Hong;Yeon-Joo, Lee;Seok-Jae, Lee;Kee-Ahn, Lee;Hwi-Jun, Kim
    • 한국분말재료학회지
    • /
    • 제29권6호
    • /
    • pp.459-467
    • /
    • 2022
  • Soft magnetic powder materials are used throughout industries such as motors and power converters. When manufacturing Fe-based soft magnetic composites, the size and shape of the soft magnetic powder and the microstructure in the powder are closely related to the magnetic properties. In this study, Fe-Si-Al-P alloy powders were manufactured using various manufacturing process parameter sets, and the process parameters of the vacuum induction melt gas atomization process were set as melt temperature, atomization gas pressure, and gas flow rate. Process variable data that records are converted into 6 types of data for each powder recovery section. Process variable data that recorded minute changes were converted into 6 types of data and used as input variables. As output variables, a total of 6 types were designated by measuring the particle size, flowability, apparent density, and sphericity of the manufactured powders according to the process variable conditions. The sensitivity of the input and output variables was analyzed through the Pearson correlation coefficient, and a total of 6 powder characteristics were analyzed by artificial neural network model. The prediction results were compared with the results through linear regression analysis and response surface methodology, respectively.

유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가 (Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography)

  • 홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.229-235
    • /
    • 2015
  • 유방확대수술이 미용을 위한 성형뿐만 아니라 유방암 절제술 후 재건의 목적으로 받는 등의 증가 추세이다. 유방확대수술을 받은 여성은 유방에 삽입한 보형물이 유방실질을 가려 유방질환을 진단하기 어려운 경우가 점점 증가하고 있고, 압박대로인한 보형물 파열 우려로 환자의 두려움은 증가하고 있다. 그러므로 유방보형물 삽입 여성에게 적용 가능한 압박대를 개발하여 그 유용성을 알아보고자 하며, 기존의 압박대와 새롭게 개발한 압박대를 유방보형물 삽입 환자모형의 phantom에 적용시켜 영상을 얻은 후 유방의 Inner, Outer 부분과 유두후방길이(Posterior Nipple Line; PNL), 전체적인 포함면적을 비교하여 그 유용성을 비교해보고자 한다. 개발한 압박대로 압박 시 전체 면적은 CC view에서 $9,813.797mm^2$로 10.09% 증가하였고, CC-ID view에서 $7,621.531mm^2$로 3.88% 증가하였으며, PNL은 CC view에서 90.916mm로 3.41% 증가, CC-ID view에서 75.357mm로 1.64% 증가하였다. 또한 흉벽 측 유방조직은 CC view에서 177.725mm로 3.53% 증가하였고, CC-ID view에서 152.510mm로 6.57% 증가되는 것으로 나타났으며, 기존의 압박대에 비해 개발한 압박대의 CC-ID 영상에서는 보형물이 완전히 제거된 것을 확인할 수 있었다.

저체온순환정지와 역행성 뇌관류에 의한 대동맥궁을 침범한 급성 대동맥 박리증의 수술결과 (Repair of Acute Aortic Arch Dissection with Hypothermic Circulatory Arrest and Retrograde Cerebral Perfusion)

  • 이삼윤
    • Journal of Chest Surgery
    • /
    • 제37권1호
    • /
    • pp.43-49
    • /
    • 2004
  • 배경: 급성 대동맥 박리증 중 대동맥궁의 박리 및 수술을 요하는 경우 진단, 수술방법, 수술결과에 있어 차이가 있을 수 있다. 대동맥궁의 박리를 교정하기 위해서 저체온 순환정지하에서 뇌관류를 시행한다. 대동맥궁의 수술이 필요한 대동맥 박리증에서 역행성 뇌관류에 의한 수술결과를 조사하고 그 안정성을 알아보았다. 대상 및 방법: 1996년 1월부터 2002년 6월까지 대동맥궁을 침범한 급성대동맥 박리증의 수술 환자 22예를 대상으로 하였다. 22예 중 20예에서 저체온 순환정지 하에 역행성 뇌관류를 시행하였다. 역행성 뇌관류를 시행한 20예 중 19예에서는 상대정맥을 통해 뇌관류를 시행하였고 1예에서는 상대정맥의 접근이 어려워 역행성 체정맥 관류를 시행하였다. 직장온도 16∼18도에서 순환정지를 시행했고 역행성 관류압 20∼30 mmHg에서 평균 관류량은 분당 481.1$\pm$292.9 $m\ell$이었다. 결과: 병원사망은 2예(9.1%)였으며 만기사망은 1예(4.5%)였다. 평균 순환정지(역행성 뇌관류) 시간은 54.0$\pm$13.4분(범위, 7∼145분)이었다 역행성 뇌관류 시간은 의식 및 지남력 회복, 호흡기 탈거 시간과 상관관계가 없었고(각각 p=0.35, 0.86, 0.92), 의식출현과 지남력 회복이 빠른 환자에서 호흡기 탈거도 빨랐다(각각 r=0.850, r=926; p=0.000). 70분 이상의 역행성 뇌관류가 의식출현, 지남력 회복, 호흡기 탈거 시간, 운동력회복 및 입원기간에 영향을 주지 않았다(각각 p=0.42, 0.57, 0.60, 0.83, 0.51). 결론: 저체온 순환정지하에 역행성 뇌관류로써 대동맥궁을 포함한 대동맥박리증 수술 시 뇌관류 시간은 의식회복과 호흡기 탈거, 신경학적 합병증, 수술 후 회복기간에 영향을 주지 않는다고 생각된다.

Safety and efficacy of target controlled infusion administration of propofol and remifentanil for moderate sedation in non-hospital dental practice

  • Douglas Lobb;Masoud MiriMoghaddam;Don Macalister;David Chrisp;Graham Shaw;Hollis Lai
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권1호
    • /
    • pp.19-28
    • /
    • 2023
  • Background: Fearful and anxious patients who find dental treatment intolerable without sedative and analgesic support may benefit from moderate sedation. Target controlled infusion (TCI) pumps are superior to bolus injection in maintaining low plasma and effect-site concentration variability, resulting in stable, steady-state drug concentrations. We evaluated the safety and efficacy of moderate sedation with remifentanil and propofol using TCI pumps in non-hospital dental settings. Methods: A prospective chart review was conducted on 101 patients sedated with propofol and remifentanil using TCI pumps. The charts were completed at two oral surgeons and one general dentist's office over 6 months. Hypoxia, hypotension, bradycardia, and over-sedation were considered adverse events and were collected using Tracking and Reporting Outcomes of Procedural Sedation (TROOPS). Furthermore, patient recovery time, sedation length, drug dose, and patient satisfaction questionnaires were used to measure sedation effectiveness. Results: Of the 101 reviewed sedation charts, 54 were of men, and 47 were of women. The mean age of the patients was 40.5 ±18.7 years, and their mean BMI was 25.6 ± 4.4. The patients did not experience hypoxia, bradycardia, and hypotension during the 4694 min of sedation. The average minimum Mean Arterial Pressure (MAP) and heartbeats were 75.1 mmHg and 60.4 bpm, respectively. 98% of patients agreed that the sedation technique met their needs in reducing their anxiety, and 99% agreed that they were satisfied with the sedation 24 hours later. The average sedation time was 46.9 ± 55.6 min, and the average recovery time was 12.4 ± 4.4 min. Remifentanil and propofol had mean initial effect-site concentration doses of 0.96 µ/.ml and 1.0 ng/ml respectively. The overall total amount of drug administered was significantly higher in longer sedation procedures compared to shorter ones, while the infusion rate decreased as the procedural stimulus decreased. Conclusion: According to the results of this study, no patients experienced adverse events during sedation, and all patients were kept at a moderate sedation level for a wide range of sedation times and differing procedures. The results showed that TCI pumps are safe and effective for administering propofol and remifentanil for moderate sedation in dentistry.