• Title/Summary/Keyword: Total ozone

Search Result 251, Processing Time 0.027 seconds

Studies on the Behaviour of Ozone Concentration and the Influencing Factors (오존농도의 動態 및 影響因子에 關한 硏究)

  • 金旻永;姜熙坤;李完宗;李相七;張鳳勳;朴聖培
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.55-71
    • /
    • 1989
  • This study was carried out to determine the ozone concentration to behaviour and the factors to be influenced the variation of its concentration in the ambient air in Seoul. Measurements of ozone concentrations were made at 10 monitoring station to take care of SIHE (Seoul Institute of Health & Environment) during December 1987 to November 1988, also measured the hourly average concentration of sulfur dioxide, total suspended particulate, nitrogen oxide $(NO & NO_2)$, carbon monoxide, hydro carbon $(n-CH_4 & THC)$ and meteorological factors, that is, temperature, humidity, wind velocity wind direction and ultraviolet intensity etc, for the same period at same place. The basis of the data obtained were analyzed statistically along with the various data. The results were as follows; 1. The annually arithmetic mean concentration of ozone for the 10 sites during one years was 10.0 ppb and ranged from 3.1 $\pm$ 4.5ppb at the Kuro industrial complex to 17.2 $\pm$ 18.7 ppb at the Ssangmun site. 2. The frequency of hours on which oxidant concentrations exceeded the present short term standard of ozone (100 ppb) were 78 times. 3. The diurnal patterns of hourly ozone concentrations in Seoul area was a typical bi-modal variation which have 4 to 5 a.m. peak and 3. to 4 p.m peak. 4. The time ozone of highest ozone concentration in a whole day and hight was 1 to 5 p.m and 90.9 percent of appearence rate. 5. The diurnal patterns of hourly ozone concentrations in Seoul were on the whole the order of daytime from 5.8ppb to 28.7 ppb evening from 1.7 to 18.7 ppb night time from 1.9 to 9.3 ppb daybreak from 1.4ppb according to measuring sites, and the highest that observed at the Ssangmun area while the lowest was the Kuro industrial complex monitor sites. 6. The weekly variation of ozone concentration was the higher level ozone concentration in the day of the week occured sunday-monday and weekend but the decrease were observed from wednesday to thursday.

  • PDF

A Study on the Bleaching of Cotton Fabrics by utilizing Ozone(($O_{3}$) (오존($O_{3}$)을 이용한 면직물의 표백에 관한 연구)

  • Cho, Hwan;Seo, Mal Young;Yu, Jae Sun;Lee, Byung Hyun;Huh, Man Woo;Lee, Kwang Woo;Cho, In Sul;Jong, Hee Cheon
    • Textile Coloration and Finishing
    • /
    • v.5 no.4
    • /
    • pp.49-59
    • /
    • 1993
  • In order to study the bleaching of cotton fabrics, ozone which has been produced by an ozone generator, has been contacted with cotton fabrics in water at various conditions. The equipments used for the ozone treatment of cotton fabrics were the ozone generator and a liquor/ozone contactor. For the examination of the ozone bleaching effect on cotton fabrics the whiteness, tensile strength, wettability and clark softness of the ozone treated cotton fabrics were measured. The conclusion obtained were, ozone concentration was increased, as the voltage was increased and flow rate was decreased and oxygen amount was increased. Bleaching effect of treated fabrics increased with increasing attributed more the net concentration of ozone rather than the total ozone amount of produced. The whiteness of treated fabrics was found to be best when treating temperature was 15~20<$^{\circ}C$, in acidic condition. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised, and the acidity increased. The wicking distance of treated fabrics increased slightly with increasing the treating time and the temperature. Clark softness of treated fabrics was not changed until passing 30min. of the treating time, then it decreasing linealy with increasing the treating time.

  • PDF

The study on the Removal of Metallic Impurities with using UV/ozone and HF cleaning (금속불순물 제거를 위한 UV/ozone과 HF 세정연구)

  • Lee, Won-Jun;Jeon, Hyeong-Tak
    • Korean Journal of Materials Research
    • /
    • v.6 no.11
    • /
    • pp.1127-1135
    • /
    • 1996
  • 반도체 소자가 고집적화 됨에 따라 단위공정의 수가 증가하게 되었고 동시에 실리콘 기판의 오염에 대한 문제가 증가하였다. 실리콘 기판의 주 오염물로는 유기물, 파티클, 금속분순물 등이 있으며 특히, Cu와 Fe과 같은 금속불순물은 이온주입 공정, reactive ion etching, photoresist ashing과 같은 실 공정 중에 1011-1013atoms/㎤정도로 오염이 되고 있다. 그러나 금속불순물 중 Cu와 같은 전기음성도가 실리콘 보다 큰 오염물질은 일반적인 습석세정방법으로는 제거하기 힘들다. 따라서 본 연구에서는 Cu와 Fe과 같은 금속불순물을 제거할 목적을 건식과 습식 세정방법을 혼합한 UV/ozone과 HF세정을 제안하여 실시하였다. CuCI2와 FeCI2 표준용액으로 실리콘 기판을 인위적 오염한 후 split 1(HF-only), split 2 (UV/ozone+HF), split 3 (UV/ozone + HF 2번 반복), split 4(UV/ozone-HF 3번 반복)를 실시하였고 TXRF(Total Reflection X-Ray Fluorescence)와 AFM(Atomic Force Microscope)으로 금속불순물 제거량과 표면거칠기를 각각 측정하였다. 또한 contact angle 측정으로 세정에 따른 표면상태도 측정하였다. TXRF 측정결과 split 4가 가장 적은 양의 금속불순물 잔류량을 보였으며 AFM 분석을 통한 표면거칠기도 가장 작은 RMS 값을 나타내었다. Contact angle 측정 결과 UV/ozone 처리는 친수성 표면을 형성하였고 HF처리는 소수성 표면을 형성하였다.

  • PDF

Comparison of Chlorine, Chlorine Dioxide and Ozone as Disinfectants in Drinking Water (정수소독공정에 이용되는 염소, 이산화염소, 오존 소독제의 비교, 고찰에 관한 연구)

  • Lee, Yoon-Jin;Lee, Sun-Jong;Lee, Dong-Chan;Kim, Hyun;Lee, Hwan;Lee, Cheol-Hyo;Nam, Sang-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.1-8
    • /
    • 2002
  • The experiments for the characterization of inactivation were performed in a series of batch processes with the total coliform as a general indicator organism based on chlorine, chlorine dioxide and ozone as disinfectants. The water sam-ples were taken from the outlet of settling basin in a conventional surface water treatment system that is provided with the raw water drawn from the mid-stream of the Han River. The inactivation of total coliform was experimentally ana-lyzed for the dose of disinfectant contact time, pH, Temperature and DOC. The nearly 2.4,3.0,3.9 log inactivation of total coliform killed by injecting 1 mか1 at 5 minutes for chlorine, chlorine dioxide and ozone. For the inactivation of 99.9%(3 log), Disinfectants required were 1.70, 1.00 and 0.60 mか1 for chlorine, chlorine dioxide and ozone, respec-tively. The higher the pH is, the poorer the disinfections effects are in the range of pH 6-9 by using chlorine and ozone. But the irfluence of pH value on killing effects of chlorine dioxide is weak. The parameters estimated by the models of Chick-Watson, Hom, and Selleck from our experimental data obtained for chlorine are: log(N/ $N_{0}$ )=-0.16 CT with n= 1, log(N/ $N_{0}$ )=-0.71 $C^{0.87}$T with n$\neq$1, for Chicks-Watson model, log (N/ $N_{0}$ )= -1.87 $C^{0.47}$ $T^{0.36}$ for Hom model. For chlorine dioxide are: log(N/ $N_{0}$ )= -1.53 CT with n = 1, log(N/ $N_{0}$ )= -2.29 $C^{0.94}$T with n$\neq$1,, for Chicks-Watson model, log(N/ $N_{0}$ )= -3.64 $C^{0.43}$ $T^{0.24}$ for Hom model and for ozone are: log(N/ $N_{0}$ )= -2.59 CT with n = 1, log(N/ $N_{0}$ )= -2.28 $C^{0.36}$T with n$\neq$1, for Chicks-Watson model, log(N/ $N_{0}$ )= -4.53 $C^{0.26}$ $T^{0.19}$ for Hom model.19/ for Hom model.

Monitoring of the Atmospheric Aerosol using TOMS Aerosol Index Data (TOMS(Total Ozone Mapping Spectrometer) Aerosol Index자료를 이용한 대기 에어로졸 모니터링)

  • 이권호;김영준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.441-442
    • /
    • 2001
  • TOMS (Total Ozone Mapping Spectrometer)는 Nimbus-7과 Meteor-3에 탑재되어 자외선 영역에서 오존의 양을 측정하는 임무를 가지고 1978년부터 1994년 12월까지 일별 오존자료를 제공하였다. 1996년 8월 17일에 발사된 일본의 ADEOS에 탑재된 TOMS는 1997년 6월 29일까지 자료를 생산했으며 1996년7월 2일 발사된 Earth Probe의 TOMS는 현재까지 실시간 자료를 보내오고 있다. TOMS는 지구의 대기에 의해 반사된 태양 광선중의 자외선 자료를 통해 오존의 양을 간접적으로 측정하는 것이 원리이다. (중략)

  • PDF

Effects of Fertilization on Physiological Parameters in American Sycamore (Platanus occidentalis) during Ozone Stress and Recovery Phase

  • Han, Sim-Hee;Kim, Du-Hyun;Lee, Jae-Cheon;Kim, Pan-Gi
    • Journal of Ecology and Environment
    • /
    • v.32 no.3
    • /
    • pp.149-158
    • /
    • 2009
  • American sycamore seedlings were grown in chambers with two different ozone concentrations ($O_3$-free air and air with additional $O_3$) for 45 days. Both the control and the $O_3$ chambers included non-fertilized and fertilized plants. After 18 days of $O_3$ fumigation, seedlings were placed in a clean chamber for 27 days. Seedlings under ozone fumigation showed a significant decrease in pigment contents and photosynthetic activity, and a significant increase in lipid peroxidation. Fertilization enhanced physiological damage such as the inhibition of photosynthetic activity and the increase of lipid peroxidation under ozone fumigation. During the recovery phase, the physiological damage level of seedlings increased with ozone fumigation. In addition, physiological damage was observed in the fertilized seedlings. Superoxide dismutase (SOD) and glutathione reductase (GR) activities of $O_3$-treated seedlings increased up to 33.8% and 16.3% in the fertilized plants. The increase of SOD activity was higher in the fertilized plants than in the non-fertilized plants. Negative effects of ozone treatment were observed in the biomass of the leaves and the total dry weight of the fertilized sycamore seedlings. The $O_3$-treated seedlings decreased in stem, root and total dry weight, and the loss of biomass was statistically significant in the fertilized plants. In conclusion, physiological disturbance under normal nutrient conditions has an effect on growth response. In contrast, in conditions of energy shortage, although stress represents a physiological inhibition, it does not seem to affect the growth response.

MONNTORING AIR QUALITY AND ACIDDEPOSITION IN SOUTHERN U.S.

  • Allen, Eric R.
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1997.10a
    • /
    • pp.1.1-32
    • /
    • 1997
  • Atmospheric monitoring capabilities were established in 1988 by the University of Florida at Duke forest, near Durham. NC: Cary forest, near Gainesville, FL: and Austin forest, near Nacogdoches, TX. Continuous (hourly averaged) measurements of air quality (ozone, nitrogen oxides and sulfur dioxide) and meteorological variables were made at these three low elevation (< 200 meters), rural locations in the southeastern U.S. for more than three years. During the same period at these sites wet and dry acid deposition samples were collected and analyzed on an event and weekly basis, respectively The monitoring locations were selected to determine actual atmospheric exposure indices for southern pine species in support of on-site surrogate exposure chamber studies conducted by Southern Commercial Forest Research Cooperative (SCFRC) investigators. Daily and quarterly averaged ozone maxima were higher (55 ppb) at the northernmost site in the network (Duke forest) in the second and third quarters (spring and summer seasons) and lower (35 ppb) in the first and fourth quarters (winter and fall seasons), when compared to ozone levels at the two southernmost sites (Cary and Austin forests). Seasonal ozone levels at the latter two sites were similar Nitrogen oxieds and sulfur dioxide levels were insignificant (< 5 ppb) most of the time at all sites, although soil emissions of NO at two sites were found to influence nighttime ozone concentrations. Typical maximum quarterly and annual aggregate ozone exposure indices were significantly higher at Duke forest (92.5/259 ppm-hr) than those values observed at the two southern sites (65.6/210 ppm-hr). Acid deposition (wet and dry) components concentrations and deposition fluxes observed at the Duke forest, NC piedmont site, were generally greater, dependent on site and season, than corresponding variables measured at either of the two southern coastal plain sites (Cary and Austin forests). Acid deposition variables observed at the latter two sites were remarkably similar, both qualitatively and quantitatively, although the sites were located 1300 km apart. A comparison of deposition fluxes of elemental nitrogen (NO3, NH4') and sulfur (5042-, SO3) components in wet and dry forms indicated that wet deposition accounts for approximately 70% of the total nitrogen and 73% of the total sulfur input on an annual equivalent basis at all sites.

  • PDF

The Characteristics of THMs Production by Different Disinfection Methods in Swimming Pools Water (수영장 욕조수의 소독방법에 따른 THMs 발생 특성)

  • Lee Jin;Ha Kwang-Tae;Zoh Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.171-178
    • /
    • 2006
  • The objectives of this study were to investigate the formation of trihalomethanes(THMs) and to compare the concentration level of THMs of swimming pools water by different disinfection methods such as chlorine, ozone-chlorine, and salt brine electrolysis generator (SBEG). The concentration of chloroform was the highest in the chlorine system, and the SBEG was the highest in the production of bromodichloromethane (BDCM), dibromochloromethane (DBCM) and bromoform. The average concentration of total trihalomethanes (TTHMs) in three disinfection systems were $64.5{\pm}27.4mg/l(SBEG),\;43.8{\pm}22.3mg/l(chlorine)$, and $30.6{\pm}16.1mg/l(ozone-chlorine)$, respectively. In chlorine and ozone-chlorine disinfection system, chloroform concentration was highest, followed by BDCN, then DBCM. In the SBEG, TTHMs was composed of 42% of chloroform, 28.9% of bromoform, 15.1% of BDCM and 14% of DBCM, respectively. The strongest correlation was obtained in the levels of chloroform and TTHMs in chlorine, and ozone-chlorine disinfection systems from both indoor and outdoor swimming pools ($r=0.989{\sim}0.999$, p<0.01). In the SBEG, the levels of BDCM and TTHMs showed a good correlation (r=0.913, p<0.01). In chlorine and ozone-chlorine disinfection systems at indoor swimming pools, pH, TOC and $KMnO_4$ consumption showed strong correlation with chloroform and TTHMs concentrations (p<0.01). In the SBEG, pH and TOC were also strongly correlated with chloroform (p<0.01). pH and TTHMs were correlated as well (p<0.05).

Multivariate Analysis for Classification of Smog Type during the Summer Season in Seoul, Korea (다변량해석을 이용한 서울시 하계 스모그의 형태 분류)

  • 홍낙기;이종범;김용국
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.278-287
    • /
    • 1993
  • In order to calssify smog type durnig the summer season in Seoul, air Quality and meterorological data were analyzed by multivariate analysis. Among 15 variables relating to visibility, 10 variables were selected by multiple regression analysis for clustering of smog types; total suspended particle, sulfur dioxide, ozone, ntrogen dioxide, total hydrocarbon, south-north wind component, ralative humidity, precipitable water, mixing height and air temperature. Somg types were grouped into three clusters using cubic clustering criterion and the mumbers of days in each cluster were contained 74, 28 and 16 days. Each cluster was seperated clearly by sulfur dioxide, precipitable water and air teperature. The first cluster was representative of high ozone concentration and prevailing meterological conditions for ozone formation. Therefore, visibility in the first cluster was considered to be affected by photochemical smog. The third cluster showed characteristics of sulphurous smog type due to the higher concentration of primary pollutant, based on the dry condition than that in another cluster. On the other hand, the characteristic of the second cluster was not relatively clear, but considered to be in an intermediate characteristic between photochemical smog and sulphurous smog type.

  • PDF

An Ozone Micro-bubble Technique for Seed Sterilization in Alfalfa Sprouts

  • Kwack, Yurina;Kim, Kyoung Koo;Hwang, Hyunseung;Chun, Changhoo
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.901-905
    • /
    • 2014
  • The efficacy of ozone micro-bubble water (OMBW) in reducing microbial populations on alfalfa seeds was investigated in this study. We observed the surface of alfalfa seeds using microscopy and found that many cracks and crevices existing on the surface could harbor pathogens. Alfalfa seeds were treated with tap water (TW), micro-bubble water (MBW), ozone water (OW), ozone micro-bubble water (OMBW), and chlorine water (CL) for 5 min, and total microbial population, E. coli and Salmonella spp. colonies were determined. Also, the sterilized seeds were germinated and cultivated for 5 d after sowing to investigate the percentage of germination and the growth of alfalfa sprouts. The treatments with OMBW and CL were most effective in reducing total microbial populations and E. coli was eliminated by OW, OMBW, and CL treatments. CL treatment reduced the percentage of germination and fresh weight of alfalfa sprouts, but OMBW did not cause any negative effects on the germination and growth of alfalfa sprouts. These results indicate that OMBW can be used as an effective sanitizer for eliminating seed-borne pathogens without detrimental effects on seed viability.