• 제목/요약/키워드: Total heat exchanger

검색결과 147건 처리시간 0.03초

모듈형 쉘-관군 열교환기에서의 응축열전달 및 압력강하 특성에 관한 수치해석 (Numerical Analysis on the Condensation Heat Transfer and Pressure Drop Characteristics of the Horizontal Tubes of Modular Shell and Tube-Bundle Heat Exchanger)

  • 고승환;박형규;박병규;김찬중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.191-198
    • /
    • 2001
  • A numerical analysis of the heat and mass transfer and pressure drop characteristics in modular shell and tube bundle heat exchanger was carried out. Finite Concept Method based on FVM and $k-\varepsilon$ turbulent model were used for this analysis. Condensation heat transfer enhanced total heat transfer rate $4\sim8%$ higher than that of dry heat exchanger. With increasing humid air inlet velocity, temperature and relative humidity, and with decreasing heat exchanger aspect ratio and cooling water velocity, total heat and mass transfer rate could be increased. Cooling water inlet velocity had little effect on total heat transfer.

  • PDF

열교환기가 공기조화용 터보팬의 성능에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effect of heat exchanger on turbo fan for air conditioning)

  • 장승용;남임우;주원구;조강래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.615-618
    • /
    • 2002
  • Turbo-fan for ceiling cassette type air conditioner doesn't operate in general volute. It is operated by porous material, heat exchanger. Heat exchanger increases resistance of air conditioning system and disturbs exit-flow of impeller. Therefore it has some influences on impeller capacity. In this study, we want to how that influence of exchanger on impeller capacity for ceiling cassette type air conditioner. To research, we made circular case that didn't have asymmetric part unlike rectangular case. With and without heat exchanger we measured total pressure and static pressure of impeller and three-dimensional rear flow field From the result, a turbo fan , installed in the 35mm back of fan and operated in heat exchanger, experienced $2{\%}{\~}5{\%}$% total pressure loss over all flow rate. With heat exchanger impeller efficiency decrease as flow rate decrease when flow rate coefficient was below 0.18. Especially when flow rate coefficient was below 0.12, there was $20{\%}{\~}30{\%}$ decrease of impeller efficiency.

  • PDF

편평관군 열교환기에서의 응축 열전달 및 압력강하 특성해석 (Numerical Analysis on the Condensation Heat Transfer and Pressure Drop Characteristics of the Flat Tube-Bundle Heat Exchanger)

  • 박병규;이준식
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1177-1184
    • /
    • 2005
  • A numerical analysis was carried out on the heat and mass transfer, and pressure drop characteristics of the modular tube bundle heat exchanger. The finite volume method with a $k-\varepsilon$ turbulence model was used for the analysis. Due to condensation, the total heat transfer rate is observed about $4\~8\%$ higher than that on dry surfaces. Total heat transfer rate increases with increase in the velocity, temperature and relative humidity of incoming air. It also increases with decreasing the aspect ratio of heat exchanger tube. The inlet velocity of cooling water has little effect on the total heat transfer when the other conditions are fixed.

배기열 회수용 종이 열교환기의 성능에 관한 연구 (A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 유성연;정민호;최재호;권화길;이춘우;이기성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

멀티버너 보일러용 열교환기 모듈 특성 시험 - 부하별 특성 결과 - (Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler - Part Load Test Results -)

  • 김종진;최규성;기호충;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1025-1030
    • /
    • 2008
  • We develop heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 10 bar and tested steam pressure is 4 bar. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). The test results of 100% boiler load show that heat transfer rate of 1st module is 49.7 Mcal/h which is 34% of total heat transfer rate and that of 2nd module is 82.6 Mcal/h which is 57% of total heat transfer rate. The reason of higher the heat transfer rate of 2nd module than that of 1st module is that the 2nd heat exchanger module has finned tubes instead of bare tube. The boiler load 50% results show that only 2 heat exchanger modules are needed to extract the heat from the flue gas to water. From this result, it is very important of optimum design of the first finned tube among all water tubes.

  • PDF

배기열(排氣熱) 회수용(回收用) 축류(軸流) 회전형(回轉形) 현열교환기(顯熱交換器)의 최적설계(最適設計)에 관한 연구(硏究) (A Study on the Optimum Design of Axial Rotary Sensible Heat Exchanger for the Heat Recovery of Exhaust Gas)

  • 최영돈;박상동;우정선;태춘섭
    • 설비공학논문집
    • /
    • 제3권2호
    • /
    • pp.131-141
    • /
    • 1991
  • A method of optimum design of an axial rotary sensible heat exchanger for the heat recovery of exhaust gas from the air conditioning space was developed in consideration of economics of investment cost and profit according to the installation of heat exchangers. Leakage rate of exhaust gas was calculated and the correlation for the pressure drop due to leakage of exhaust gas was proposed. Heat transfer between the matrix and exhaust and intake gas was analysed to calculate the effectiveness of heat exchanger, which was used for the optimum design of rotary heat exchanger. The results show that optimum rotational speed increases as the length of rotor increases and there exists optimum NTU which maximizes the gain of total cost according to the installation of rotary heat exchanger.

  • PDF

루버형 휜을 가진 휜관형 열교환기의 착상현상 연구 (Study on the Frosting Phenomenon of the Fin and Tube Heat Exchanger with a Louvered Fin)

  • 김정국;코야마 시게루;쿠와하라 켄;박병덕
    • 한국산업융합학회 논문집
    • /
    • 제11권4호
    • /
    • pp.157-163
    • /
    • 2008
  • The present study investigated the pressure drop and the total frost mass of the louvered fin type heat exchanger, which is widely used at the air-conditioning system. The pressure drop due to the frosting phenomenon and the total frost mass were investigated by changing the wet bulb temperature condition of the inlet air. Hence the brain of 55wt% was used as a cooling solution instead of a common refrigerant. The temperature difference between the brine and the tube outside wall at the outlet of heat exchanger was $10^{\circ}C$, at maximum, higher than that at the inlet of heat exchanger. As the wet bulb temperatures were increased, the pressure drop was linearly increased due to the increment of frost mass. And the increment of heat exchange rate was smaller than that of inlet air enthalpy due to the increment of frost mass. The pressure drop of air side was rapidly increased due to the progress of frosting phenomena. The run time that the pressure drop occurred rapidly was decreased by the growth of frost.

  • PDF

배기열 회수용 종이 열교환기의 성능에 영향을 미치는 인자에 관한 연구 (A Study on the Factors Affecting the Performance of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 정민호;유성연
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.956-964
    • /
    • 2005
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery The purpose of this research is to find the factors affecting the performance of paper heat exchanger for exhaust heat recovery, which can be applied directly to the conventional ventilation unit, air-purifier, and air-conditioning system. In this study, thermal performance and pressure loss of the paper heat exchanger are measured and compared at various operating conditions. The effectiveness of sensible, latent and total heat at the face velocity of 0.75 m/s are $77\%,\;47\%\;and\;57\%$ in the cooling condition and $77\%,\;59\%,\;and\;\%$ in the heating condition, respectively. The effectiveness for sensible heat is only affected by velocity. On the other hand, the effectiveness for latent heat is affected. by temperature and relative humidity.

동관-알루미늄 휜 회전형 히트파이프 열교환기의 성능에 관한 연구 (A Study on the Performance of Rotary Heat Exchanger using Aluminum Finned Copper Tube Heat Pipe)

  • 박기호;이기우;이계중;전원표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.7-12
    • /
    • 2000
  • The purpose of this study is to develop heat transfer analysis program of heat pipe elements and design a revolving heat pipe exchanger by the performance experiment of hot air production by means of middle-temperature waste heat. Experimental variables are the revolution per minute, normal velocity of inlet air and the temperature of waste heat. The revolving heat exchanger has designed as $2^{\circ}$ in inclination angle of heat pipe bundle and as 20% in working fluid quantity and as water in working fluid. Experimental value of the total heat transfer coefficient was $20w/m^2-^{\circ}C$

  • PDF

다공의 전열판이 내장된 공기 대 공기 전열교환기의 성능 평가 (Performance Evaluation of Air-to-Air Total Heat Transfer with Rotating Porous Plates)

  • 임태우;조동현
    • 동력기계공학회지
    • /
    • 제11권2호
    • /
    • pp.20-25
    • /
    • 2007
  • The performance of air-to-air heat exchanger has been investigated with rotating porous plates newly developed in this study. With an equal interval of 18 mm, the rotating porous plates are installed inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. Dry bulb temperature is set by adjusting heat supply at heater. In order to measure the temperature distribution of the hot air side inside heat exchanger, the thermocouples are inserted between the plates. The first location of thermocouple is 10mm downstream from the inlet of heat exchanger, and succeeding ten locations are aligned at an equal interval of 18mm. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat transfer rate increased as both air flow rate and RPM of the rotating porous plate increased. It was found that the overall heat transfer coefficient increased with the increase in RPM of porous plate at the conditions of the same air flow rate.

  • PDF