• Title/Summary/Keyword: Total heat

Search Result 2,414, Processing Time 0.03 seconds

Evaluation of Fire Characteristics for Particle-board with Exfoliated Graphite Nanoplatelets Added (탄소재료의 적용 방법에 따른 파티클 보드의 연소 특성)

  • Seo, Hyun Jeong;Jo, Jeong Min;Hwang, Wuk;Lee, Min Chul
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.4
    • /
    • pp.1-8
    • /
    • 2017
  • This study was conducted to evaluate the fire retardant performance of exfoliated graphite nanoplatelets (xGnP) applied for particleboard. This work measured heat release rate(HRR), total heat release(THR) and smoke production rate(SPR) of xGnP added particleboard, using cone calorimeter to assess its fire characteristics according to the KS F ISO 5660-1 standard code. Heat release rates of all specimens treated by xGnP were less than the $200kW/m^2$ for a total experiment period of five minutes. Heat release rates of the specimens coated with xGnP were lower than those of the specimens made by mixing wood particles with xGnP directly. Meanwhile, the total heat release rates of xGnP coated specimen maintained quite lower level than the uncoated so the xGnP coating were effective in improving the fire retardant performance of particleboard. However, the smoke emission peaking problem at the initial combustion period, which was caused by adding base coating materials, should be resolved for further satisfaction as a fire retardant materials.

A Computer Simulation of the Combustion and Flueway of a Pulse Combustion Water Heater (맥동연소온수기의 연소실과 노도의 컴퓨터 시뮬레이션)

  • Kang, Kun;Shin, Sei-Kun;Kim, Min-Sik
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.64-72
    • /
    • 1989
  • In this study, the computer simulation for the heat transfer in pulse combustion water heater is performed. The attention is focused to the effects of the installation of corebuster in the flue tube on heat transfer. The energy equations are established for both wall and gas side in the combustion chamber, flue way, exhaust chamber and muffler, and the numerical calculation is executed. Zone method takes longer computer calculation time compared with semi-zone method. Semi-zone method is chosen for numerical calculation. As a result of this study, it is found that the installation of the core buster in flue tube increases total heat transfer. It is also found that the total heat transfer is increased with the increasing of the ratio of the cross section area of corebuster to that of the flue tube. However, the heat transfer effect is negligible for the area ratio above 0.5.

  • PDF

Drained End Shield Effects on Heat Deposition Rate Distribution in CANDU 6 Reactor End Shield Structure

  • Jin, Yung-Kwon;Kim, Kyo-Youn;Hwang, Hae-Ryong
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.570-577
    • /
    • 1994
  • The loss of water in the carbon steel balls and water region of the end shield for CANDU 6 reactor could lead to significant temperature gradient through the end shield structure which amy result in the excessive deformation. With an assumed end shield drained scenario, the heat deposition rates were calculated through the end shield associated with the central fuel channel during full power operation as an initial step to thermal stress analysis. The drained case was compared with that of water present normal case in therms of heat deposition rater and the total heating throughout the end shield regions. The compared results show that the heat deposition and the total heating remain almost the same between the two cases. It was found that the change of volume integrated flux in the end shield regions due to the loss of water contribute a negligible effect on the heat deposition in this region.

  • PDF

Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler - Part Load Test Results - (멀티버너 보일러용 열교환기 모듈 특성 시험 - 부하별 특성 결과 -)

  • Kim, Jong-Jin;Sung, Choi-Kyu;Ki, Ho-Choong;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1025-1030
    • /
    • 2008
  • We develop heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 10 bar and tested steam pressure is 4 bar. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). The test results of 100% boiler load show that heat transfer rate of 1st module is 49.7 Mcal/h which is 34% of total heat transfer rate and that of 2nd module is 82.6 Mcal/h which is 57% of total heat transfer rate. The reason of higher the heat transfer rate of 2nd module than that of 1st module is that the 2nd heat exchanger module has finned tubes instead of bare tube. The boiler load 50% results show that only 2 heat exchanger modules are needed to extract the heat from the flue gas to water. From this result, it is very important of optimum design of the first finned tube among all water tubes.

  • PDF

Total bilirubin level as a biomarker for dampness-heat differentiation in traditional Korean treatment for jaundice

  • Sohn, Ki Cheul;Jung, Hyun-Jung;Lee, A-Jin;Kim, Sang-Gyung;Shin, ImHee;Kwak, Sang Gyu
    • The Journal of Korean Medicine
    • /
    • v.34 no.4
    • /
    • pp.46-55
    • /
    • 2013
  • Objectives: Classifying the pattern of jaundice during diagnosis will significantly improve the outcome of common KM interventions. This study aimed at determining an objective index for accurately diagnosing heat and dampness KM patterns in patients with jaundice. Methods: We systematically reviewed laboratory findings from case reports published in the scientific literature of Korean medicine. Cases were classified as following either the heat or dampness pattern. Biochemical indices were compared using a Bayesian factor (BF) analysis and standard t-tests. Results: The laboratory findings of 32 patients were evaluated. The heat pattern was observed in 17 patients and the dampness pattern in 15. No significant differences were observed between the 2 groups in terms of white blood cell count (BF=1.659); hemoglobin concentration (BF=2.627); platelet count (BF=1.019); or levels of direct bilirubin (BF=1.453), aspartate aminotransferase (BF=1.226), alanine aminotransferase (BF=1.340), alkaline phosphatase (BF=2.344), or gamma-glutamyl transpeptidase (BF=2.782). However, total bilirubin levels were significantly higher in the dampness pattern group (BF=0.854, P-value=0.070). Conclusions: Patients with high total bilirubin levels may predominantly follow the dampness pattern, while those with low levels may predominantly follow the heat pattern. These results are expected to be useful for the development of timely and efficient KM treatments as well as new integrative therapeutic approaches for jaundice. However, further studies are essential to fully validate the utility of total bilirubin as a biomarker for differentiating between heat and dampness patterns.

Effect of Heat Treatment, Ethanol Content, Extraction Time and Ratio of Solvent on the Efficiency of Polyphenol Extraction from Licorice Root (Glycyrrhizauralensis) (감초폴리페놀 추출효율에 있어 열처리, 에탄올 농도, 추출시간 및 용매비율이 미치는 영향 탐색)

  • Chae, Jung-Il;Ryu, Kyeong-Seon;Seo, Kang-Seok;Kim, Kyung-Hoon;Oh, Young-Kyoon;Jang, Sun-Sik;Choi, Chang-Weon;Choi, Nag-Jin
    • Korean Journal of Organic Agriculture
    • /
    • v.20 no.3
    • /
    • pp.399-409
    • /
    • 2012
  • Effects of pretreatment and extraction conditions on total polyphenol yield from licorice root were investigated using statistical method. For pretreatment, heat treatment at $121^{\circ}C$ for 10 min was applied. Licorice root content in solvent (10, 20, and 30%) ethanol concentration (20, 40, and 60%) and reaction time (1, 2, and 3 h) were used as variables for extraction conditions. Two experiments, with heat treated and no treated licorice, were prepared with same experimental design. Box behnken design was employed and produced a total of 15 trials. Total polyphenol yield from licorice root was not affected by heat treatment. Among variables, licorice content in solvent showed most significant effect regardless of other variables (p<0.05). Finally, optimum conditions for the extraction of total polyphenol from licorice root was detected as following: 10% of licorice in solvent, 52% ethanol as solvent, 2 h of reaction time and non-heat treatment and the extraction yield from optimized condition was 17.6 mg/g licorice root.

Changes in the Antioxidant Activity of Onion (Allium cepa) Extracts with Heat Treatment

  • Woo, Koan-Sik;Hwang, In-Guk;Kim, Tae-Myoung;Kim, Dae-Joong;Hong, Jin-Tae;Jeong, Heon-Sang
    • Food Science and Biotechnology
    • /
    • v.16 no.5
    • /
    • pp.828-831
    • /
    • 2007
  • We evaluated the effects of heat treatment on various properties of onion extracts (Allium cepa). Onion was heated at various temperatures ($110-150^{\circ}C$) for various times (1-5 hr), and the total polyphenol, flavonoid, and free sugar contents, and antioxidant activity were investigated. With increased heating temperatures and exposure times, the total contents of polyphenols and flavonoids, as well as antioxidant activity increased. The highest total polyphenol content (189.80 mg/100g) occurred after heating for 2 hr at $140^{\circ}C$. The highest total flavonoid content (252.51 mg/100g) occurred after heating for 3 hr at $150^{\circ}C$. The antioxidant activity assessed using the DPPH method was highest, at 2.1 mg/mL ($IC_{50}$ value), after heating for 2 hr at $150^{\circ}C$. Correlations between antioxidant activity and the total polyphenol, total flavonoid, and fructose contents were highly significant (all p<0.01). The optimal heating time and temperature were 2 hr and $130^{\circ}C$.

A Study on Heat Transfer Performances of a Heat Pipe Heat Sink for Power Control Semiconductors (전력제어 반도체용 히트파이프 냉각기의 열전달 성능 연구)

  • 강환국;김재진;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.701-709
    • /
    • 2001
  • In this days, heat pipe heat sink has been widely applied to power controllers for railway substations to remove heat from power semiconductors(diodes or thyristors). The heat pipe heat sink consists of a aluminum heating block for mounting the thyristor, 2~3 heat pipes and large number of aluminum fins. The present study was to get fundamental informations of the structure, design parameters and heat transfer performances of heat pipe heat sink. Series of operational test for a unit with 3 heat pipes were performed and its heat flow circuit was analysed from the experimentally obtained data on wall temperature distribution. Total resistance was ranged 0.02~$0.03^{\circ}C$/W for a power range from 40W to400W. The time to get the steady state was approximately longer than 20 minutes, and overshooting was not occurred during start up operation.

  • PDF

A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능에 관한 연구)

  • Yoo, Seong-Yeon;Chung, Min-Ho;Choi, Jae-Ho;Kwon, Hwa-Kil;Lee, Chun-Woo;Lee, Ki-Seong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

The heat transfer characteristics of a desorber for 150 RT absorption heat pump (150 RT급 흡수식 열펌프용 고온재생기의 열전달 특성)

  • 박찬우;정종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.369-376
    • /
    • 1999
  • Experiments were carried out to study the heat transfer characteristics of a disrober for 150 RT LiBr-water absorption heat pump. An experimental apparatus was divided into four sections, a combustion chamber area, two bare-tube areas, and finally a finned-tube area to quantify the heat transfer rate of each section by measuring the generation rate of vapor. Dividing plates was installed at the upper inside part of deserter to prohibit the moving of vapor generated at heating tubes of a section to another section near. In the first bare-tube area, the generation rate of vapor was the largest among the four sections. The finned-tube area only contributed to give sensible heat increase of solution to the saturation temperature. The heat transfer area of the finned-tube area was 52.2%, which absorbed only 9.2% of the total heat from the combustion gas. On the contrary, the heat transfer area of the first bare-tube area was 16.6%, but it absorbed 52.4% of the total absorbed heat. The temperature of the solution at upper part at the finned-tube area was lower than that of the lower part, because weak solution came in upper part of the finned-tube area. But, this tendency was changed at the first and second bare-tube area due to the vigorous heat transfer and fluid flow enhanced by vapor generation through heating tubes. The overall heat transfer coefficient and heat flux were the largest at the first bare-tube area among the other sections.

  • PDF