• Title/Summary/Keyword: Total heat

Search Result 2,430, Processing Time 0.024 seconds

Oplimum Design Conditions for a Basic Refrigeration Cycle (냉동사이클의 최적 설계조건)

  • Cho, Sung-Whan
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.356-361
    • /
    • 1986
  • An optimum design condition for a basic refrigeration cycle is defined as the condition which minimizes the total cost of heat exchanges (condenser and evaporator) and compressor for the refrigeration effect. Thermodynamic properties of ammonia (R717) are approximated by rational functions in order to obtain the optimum condition for a basic refrigeration cycle. Optimum condition depends on the heat capacity rates (mass flow rate times specific heat) of cooling water and brine used in condenser and evaporator. The difference between the cooling water temperature and condensation temperature at the optimum condition increases as the heat capacity rates and the coat of heat exchangers relative to the cost of compressor increase. Numerical examples of optimum conditions are obtained when the condensation temperature is $30^{\circ}C$ and the evaporator temperature is $-10^{\circ}C$.

  • PDF

Performance Tests on an Air Solar Heating System (공기식 태양열 난방계통의 성능실험)

  • Nam, Pyeong-Woo;Cha, Jong-Hee
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.8 no.2
    • /
    • pp.81-88
    • /
    • 1979
  • The performance of air type solar heating system has been investigated for a system which has been operating continuously for two years. Design factors of a collector, such as the effective transmittance-absorptance and heat transfer factor were also determined experimentally. The flat plate collector is fabricated from steel sheet metal with two sealed glass covers. Solar heat is stored in a pebble bed of primarily granitic rock approximately 20-40 mm in diameter. The system is controled by automatically driven motors and dampers. The ratio of useful collected solar heat divided by the total solar radiation on the collector dropped was the range of 35 to 42 percent in monthly average. As it result, the air system was found fairly competitive with the water system, however, the heat supply from storage was limited because of using the pebble as the heat storage media.

  • PDF

Analysis of Heat Transfer Characteristics in Response to Water Flow Rate and Temperature in Greenhouses with Water Curtain System (수막하우스의 유량 및 수온에 따른 열전달 특성 분석)

  • Kim, Hyung-Kweon;Kim, Seoung-Hee;Kwon, Jin-Kyeong
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.270-276
    • /
    • 2016
  • This study analysed overall heat transfer coefficient, heat transmission, and rate of indoor air heating provided by water curtain in order to determine the heat transfer characteristic of double-layered greenhouse equipped with a water curtain system. The air temperatures between the inner and outer layers were determined by the water flow rate and inlet water temperature. Higher water flow rate and inlet water temperature resulted in the increased overall heat transfer coefficient between indoor greenhouse air and water curtain. However, it was found that with higher levels of water flow rate and inlet water temperature, indoor overall heat transfer coefficient was converged about $10W{\cdot}m^{-2}{\cdot}^oC^{-1}$. The low correlation of overall heat transfer coefficient between water curtain and air within double layers was likely because the combination of greenhouse shape, wind speed and outdoor air temperature as well as water curtain affected the heat transfer characteristics. As water flow rate and inlet water temperature increased, the heat transferred into the greenhouse by water curtain also tend to rise. However it was demonstrated that the rate of heat transmission from water curtain into greenhouse with water curtain system using underground water was accounted for 22% to 28% for total heat lost by water curtain. The results of this study which quantify heat transfer coefficient and net heat transfer from water curtain may be a good reference for economical design of water curtain system.

Summertime Heat Waves and Ozone : an Interaction on Cardiopulmonary Mortality? - Based on the 1994 Heat Wave in Korea - (1994년 하절기의 심혈관계 및 호흡기계 초과사망 - 이상고온 및 대기오염의 영향을 중심으로 -)

  • Sung, Joo-Hon;Kim, Ho;Cho, Soo-Hun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.4
    • /
    • pp.316-322
    • /
    • 2001
  • Objectives : To explore the possible effect of an interaction between summertime heat waves and ozone on cardiopulmonary mortality during the 1994 heat wave in Korea. Methods : The unusually hot summer of 1994 in Korea was defined as the heat wave in this study. We examined the associations of air pollutants with daily cardiopulmonary deaths between 1991-1995, considering the product term of the heat wave and each pollutant, weather and time trends. Results : During the heat wave, while temperatures were uniformly higher than those of other summers, the within-heat-wave difference in mortality paralleled that in the regional ozone levels. In terms of the influence of the heat wave, the results of ozone were different to those of total suspended particles (TSP) and sulfur dioxide $(SO_2)$. The ozone association (relative risk (RR) : 1.036; 95% confidence interval (CI) = 1.018-1.054) was observed only under heat wave conditions, while the TSP (RR : 1.006, 95% CI = 0.999-1.012) and the $SO_2$ (RR = 1.018, 95% CI : 1.011-1.024) associations were found under normal weather conditions (per interquartile increase of each pollutant; results of three pollutants model). The ozone association under heat wave was attributable to the statistical interaction between the heat wave and ozone. Conclusions : These results support the possibility of a biological synergy between the heat wave and ozone, one that is not evident between the heat wave and other major pollutants like particles or $SO_2$.

  • PDF

Influences of Wearing Different Thermal Insulated Clothings on Thermoregulatory Responses from $25^{\circ}C$ Environment to 18$^{\circ}C$ Environment ($25^{\circ}C$환경에서 $18^{\circ}C$환경으로 노출시 보온력이 상이한 의복의 착용이 체온조절 반응에 미치는 영향)

  • 이종민
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.7
    • /
    • pp.826-832
    • /
    • 1998
  • In order to understand the influences of wearing clothings with different thermal insula-tions when men were exposed from $25^{\circ}C$ environment to 18$^{\circ}C$ environment, thermoregulatory responses were measured on 4 healthy female college students. Subjects rested wearing T-shirts, trousers, and socks called LC(total weight 541g) at 25$\pm$1$^{\circ}C$, 50$\pm$5% R.H. and then exposed to the room conditioned in 18$\pm$1$^{\circ}C$, 50$\pm$5$^{\circ}C$ R.H. with LC as it was(LC Type) or with T-shirts, trousers, socks, training wear upper garment, the training wear lower garment called HC (total weight 1368g)(HC Type) for 120 min. The results can be summarized as follows: 1) When subjects were exposed from $25^{\circ}C$ environment to 18$^{\circ}C$ environment, decrease of rectal temperature was significantly smaller in LC Type than in HC Type. 2)Increase of heat production and weight loss had no significant difference between two types of clothing. 3)Internal thermal conductance was higher in HC Type and external thermal conductance was higher in LC Type. Therefore total thermal conductance was higher in LC Type than in HC Type. 4)Decrease of skin temperature was greater in LC Type than in HC Type. 5)Subjects felt colder with LC Type than with HC Type, but did not feel differently in comfort sensation between two types of clothing. It was suggested that less decrease of rectal temperature in LC type inspite of more dry heat loss from body might be ascribed to a shift of blood from the shell area to the core area originating in the vasoconstriction and the lowered internal thermal conductance. In conclu-sion, the importance of the state of internal heat distribution in the homeostasis seemed to be reaffirmed.

  • PDF

The Thermal Characteristics of Tree Branches, Barks, Living Leaves and Dead Leaves in Pinus Densiflora and Quercus Dentata (소나무와 떡갈나무의 주요 부위별 열적특성에 관한 연구)

  • Park, Young-Ju;Lee, Si-Young;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.84-92
    • /
    • 2008
  • Disclosed is a study related to the thermal characteristics of Pinus densiflora and Quercus dentate identifying the presence of any significant difference in the above trees, which are native to Young Dong Province of Korea, according to different regions of the trees such as branches, barks, living leaves and dead leaves. For this purpose, we have carried out a cone calorimeter test focusing on the variables such as mass loss, heat release, ignition time, flame holding time and concentrations of CO and $CO_2$. The results showed that the total mass loss was greatest in tree branches, whereas the ignition time of dead leaves was fastest both in Pinus densiflora and Quercus dantata. The flame holding times of dead leaves and barks were about $640{\sim}1,016s$ and the total heat release of dead leaves was around 60.1 $MJ/m^2$, twice the total heat release of living leaves. In addition, the maximum exhaust concentrations of CO and $CO_2$ in tree branches of Quercus dentata was 2.82 times higher than those of Pinus densiflora, respectively. From the foregoing, it was confirmed that there exist region-specific differential thermal characteristics in Pinus densiflora and Quercus dentata.

Experimental Study on Thicknesss of Heat Storage Zone in Small Solar Pond (소형실험태양(小型實驗太陽)연못에서 열저장층(熱貯藏層)의 두께에 관(關)한 실험적(實驗的) 연구(硏究))

  • Pak, Ee-Tong;Seo, Ji-Weon
    • Solar Energy
    • /
    • v.7 no.2
    • /
    • pp.22-29
    • /
    • 1987
  • This paper dealed with thickness variation of bottom heat sotrage zone due to salinity and flow rate of extration hot brine in small test solar pond (0.5m wide, 0.5m high, 1.0m long). Testing apparatus and situation were follows: 7.1 cm of height of suction diffuser and 1.8cm of height of discharge diffuser above the test pond respectively, 0.3cm of slot size of suction diffuser, 1.0cm of slot size of discharge diffuser, 47cm of length of the slot; heating of hot water ($75^{\circ}C$) through separated hot water tank, discharge of the brine into storage zone through discharge diffuser, the extration of the brine through suction diffuser, circulation of the extracted brine through a heat exchanger (cooler). Following results were obtained through the experiments. 1. In small test solar pond, the typical three zone which showed up in real solar pond were established. 2. Richardson Number was used more effectively to confirm hydrodynamic stability of the stratified flow. 3. The thickness of non convective layer had a great effect on the heat storage of the bottom convective layer, then the temperature of bottom convective layer had a relation to that of upper convective layer. 4. Optimum operating condition in the test pond was on 10%-15% of salt concentration and $0.05m^3/hr$ of flow rate of extraction hot brine. 5. Following thickness of 3 zones were available to obtain under optimum operation condition: o bottom storage zone: $30%{\pm}10%$ of total pond depth o non-convective zone: $40%{\pm}10%$ of total pond depth o Upper surface zone: $20%{\pm}10%$ of total pond depth.

  • PDF

Relief of the negative effects of heat stress on semen quality, reproductive efficiency and oxidative capacity of rabbit bucks using different natural antioxidants

  • El-Ratel, Ibrahim Talat;Attia, Kandil Abdel Hai;El-Raghi, Ali Ali;Fouda, Sara Fikry
    • Animal Bioscience
    • /
    • v.34 no.5
    • /
    • pp.844-854
    • /
    • 2021
  • Objective: The potential of extra virgin olive oil (EVOO), betaine (BET), and ginger (GIN), as natural antioxidants, in reducing negative effects of heat stress on physiological responses, antioxidant capacity, semen quality and fertility of bucks under heat stress were investigated. Methods: Forty adult Animal Production Research Institute line rabbit bucks were distributed randomly into four experimental treatments of ten rabbits each. The first treatment was fed the commercial pellet diet (CPD) without supplementation and served as a control. The other three treatments were fed CPD supplemented with EVOO (300 mg), BET (1,000 mg), and GIN (200 mg) per kg diet for 3 consecutive months during the summer season. Results: Supplementation of EVOO, BET, or GIN improved (p<0.05) the sexual desire, progressive motility, vitality, intact acrosome and membrane integrity, sperm cell concentration, sperm outputs and fertility. Seminal plasma total proteins, globulin, total antioxidant capacity, glutathione and glutathione S-transferase, and initial fructose increased (p<0.05), while total lipids, aspartate and alanine aminotransferases and malondialdehyde decreased (p<0.05) compared with the control. In comparing the natural antioxidants treatments, GIN evoked the largest improvement. Conclusion: The inclusion of GIN (200 mg/kg diet) appeared to improve the sexual desire, semen quality and oxidative stress of bucks. This may be a beneficial supplement for the management of rabbit bucks used in natural mating or artificial insemination.

BOTANI: High-fidelity multiphysics model for boron chemistry in CRUD deposits

  • Seo, Seungjin;Park, Byunggi;Kim, Sung Joong;Shin, Ho Cheol;Lee, Seo Jeong;Lee, Minho;Choi, Sungyeol
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1676-1685
    • /
    • 2021
  • We develop a new high-fidelity multiphysics model to simulate boron chemistry in the porous Chalk River Unidentified Deposit (CRUD) deposits. Heat transfer, capillary flow, solute transport, and chemical reactions are fully coupled. The evaporation of coolant in the deposits is included in governing equations modified by the volume-averaged assumption of wick boiling. The axial offset anomaly (AOA) of the Seabrook nuclear power plant is simulated. The new model reasonably predicts the distributions of temperature, pressure, velocity, volumetric boiling heat density, and chemical concentrations. In the thicker CRUD regions, 60% of the total heat is removed by evaporative heat transfer, causing boron species accumulation. The new model successfully shows the quantitative effect of coolant evaporation on the local distributions of boron. The total amount of boron in the CRUD layer increases by a factor of 1.21 when an evaporation-driven increase of soluble and precipitated boron concentrations is reflected. In addition, the concentrations of B(OH)3 and LiBO2 are estimated according to various conditions such as different CRUD thickness and porosity. At the end of the cycle in the AOA case, the total mass of boron incorporated in CRUD deposits of a reference single fuel rod is estimated to be about 0.5 mg.

Effects of Dietary Fiber on Water Balance, Blood Acid-Base Balance, Body Temperature, and Metabolic Rate of Adult Roosters under Heat Stress (사료 섬유질이 고온 스트레스를 받는 수탉 성계의 수분 출납, 혈액의 산-염기 평형, 체온 및 대사율에 미치는 영향)

  • 이지훈;이봉덕;이수기;유동조;현화진
    • Korean Journal of Poultry Science
    • /
    • v.22 no.3
    • /
    • pp.133-144
    • /
    • 1995
  • One metabolism trial(Experiment I) and another respiration trial(Experiment II) were conducted to investigate the effects of dietary fiber supplementation(20% wheat bran) on the water balance, blood acid-base balance, body temperature, and metabolic rate of heat-stressed adult roosters. In Experiment I, twenty 20-wk-old SCWL roosters(BW 1.6 kg) were randomly alloted to 4 treatments with 5 birds per treatment and one per replicate. The 4 treatments were consisted of two temperature(21~22˚C vs. 34~35˚C) and two dietary fiber treatment(0% and 20% wheat bran), making Experiment I a 2x2 factorial. After 4 d of preliminary period, birds we subjected to 3-d collection period. Sixteen 20-wk-old SCWL roosters(BW 1.6 kg) were employed Experiment H, with two temperature(21~22˚C vs. 34~35˚C) and two wheat bran levels(0% and 20%). Brids were housed in individual metabolism cages under normal temperature(21~22˚C), at fed one of the experimental diet. After 4 d of preliminary period, a respiration trial with open-circuit gravimetric respiratory apparatus was carried out for each bird for 6 h, one by one, normal(20~21˚C) and hot(34~35˚C) temperatures. The ANOVA test and comparisons among treatment means were done at 5% probability level for both experiments. Results obtained from Experiment I and, II were summarized as follows, 1.The amounts of DM intake and excretion were significantly(P<.05) decreased by heat stress. The DM intake was not affected by the addition of 20% wheat bran, however, the amount of DM excretion was significantly increased by the high fiber diet. Thus, the DM metabolizability decreased significantly by the addition of 20% wheat bran. 2. The heat-stressed roosters increased the water intake and excreta moisture content significantly. Although not significant, the water intake tended to increase in roosters fed the 20% wheat bran diet. 3. The amounts of total water input and evaporative water loss were increased significantly by heat stress, and the addition of 20% wheat bran did not exert any influence on the total water input and evaporative water loss. However, roosters fed the 20% wheat bran diet increased the excreta water output significantly. 4. Neither the heat stress nor the dietary fiber did affect the blood pH, pCO2, and HCO$_3$- significantly. 5. The body temperature increased significantly by the heat stress. However, the high fiber deit failed to decrease the body temperature. 6. The heat-stressed roosters decreased the 02 consumption and C0$_2$ production, and increased the evaporative water loss significantly. However, the high fiber diet did not exert any infulence in this regard. It appears that the beneficial effect, if any, of high fibrous diet during heat stress episode may be due to the increased heat loss through the enhanced excreta water.

  • PDF