• Title/Summary/Keyword: Total Measuring Accuracy

Search Result 142, Processing Time 0.028 seconds

A Study on Emergency Monitoring Robot System by Back-Propagation Algorithm

  • Yoo, Sowol;Kim, Miae;Lee, Kwangok;Bae, Sanghyun
    • Journal of Integrative Natural Science
    • /
    • v.7 no.1
    • /
    • pp.62-66
    • /
    • 2014
  • This study aims to implement the emergency monitoring robot system which predicts the current state of the patients without visiting the medical institutions by measuring the basic health status of the user's blood pressure, heartbeat, and basic health status of body temperature in the disaster emergency situation based on the Smart Grid. By arranging a large number of sensor(blood pressure, heartbeat, body temperature sensor) and measuring the bio signs, so the attached wireless XBee sensor can be stored in DB of robot, and it aims to draw the current state of the patients by analysis of stored bio data. Among 300 data obtained from the sensor, 1st data to 100th data were used for learning, and from 101st data to 300th data were used for assessment. 12 results were different among the total 300 assessment data, so it shows about 96% accuracy.

Influence of Zero Reading on Predicting Crown Displacement of Tunnel (초기계측 시점이 터널 내공변위 예측에 미치는 영향분석)

  • Kim, Kwang-Yeom;Kim, Ho-Geun;Seo, Youg-Seok
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.214-220
    • /
    • 2012
  • Deformation behaviour of rock mass around an opening measured during tunnel excavation is very important in order to assess the stability of the tunnel. Unfortunately displacement measured only after the installation of displacement measuring device can be acquired, which results in inevitably excluding the pre-displacement occurred and accumulated before the displacement measuring devices are installed. So it is very important to consider the pre-displacement based on the elapsed time before zero reading after deformation behaviour started. In this study, the accuracy of total estimated displacement depending on the distance between face and measurement position is calculated by statistical non-linear fitting on measurable displacement data. Besides, the influence of the unavoidable measurement error is considered by using Monte-Carlo simulation. As a result, the faster the initial reading started and the smaller the measurement error is, the higher the accuracy of estimating total displacement is obtained.

Analysis of Body Surface Change from 3D Scan Data of Men's Upper Bodies in Twenties - Focus on Application of Motorcycle Jacket Pattern - (3차원 인체데이터에 의한 20대 성인남성 상반신 체표변화 분석 - 모터사이클복 패턴설계시 적용을 중심으로 -)

  • Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.4
    • /
    • pp.530-541
    • /
    • 2008
  • The early stage of 3D anthropometry data has been used to obtain qualitative rather than quantitative information. However recent 3D body scanners as a common research tool for anthropormatric measurments have made it possible to obtain body surface data of sufficient resolution and accuracy. The purpose of this study is finally to develop motorcycle jacket for enhanced comfort and fit, to test the accuracy and reliability of 3D measurments of motorcycle riding posture, and to analyze the change in 20's adult male's body surface measurements between the standard anthropometric position and motorcycle riding posture. The results of this study were as follows: There were no significant differences between the study and Size Korea measurments in total traditional measuring items and most of measuring items, such as length, circumference antropometric items and interscye items though not waist back length and upper arm circumference. A comparison of 3D body surface measurments in the two different measuring postures, the bodysurface measurments such as waist front length, biacromion length, front interscye, arm length, underarm length in the motorcycle riding posture decreased than that in basic posture, whereas waist back length, back interscye, C.T.W length increased. The body surface measurments such as chest, bust, upper circumference in the motorcycle riding posture decreased than that in basic posture, whereas neck, waist, hip, elbow circumference increased.

Validation of an Extraction Method for the Determination of Airborne MWFs using Alternative Solvents (대체용매를 이용한 금속가공유 측정방법 타당성 평가)

  • Jeong, Jee Yeon;Baek, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.91-100
    • /
    • 2006
  • The purpose of this study was to validate alternative method by using non-carcinogenic, and less toxic solvents than NIOSH analytical method 5524 for measuring the airborne MWFs in workplaces. In laboratory tests, the ETM solvents(mixture of same volume for ethyl ether, toluene, and ethanol) were selected. The alternative method of analyzing MWFs, referred to as the ETM solvent extraction method, showed 0.04 mg/sample as LOD, and 0.15 mg/sample as LOQ. The analytical precision (pooled CV, coefficient of variation) of the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was 1.5%, 2.0%, 2.6%, 1.6%, respectively, which was similar to the precision (2.6%) of NIOSH analytical method (NIOSH 0500) for total dust. The analytical accuracy by recovery test, spiked mass calculated as extractable mass, was almost 100%. As the result of storage stability test, metalworking fluid samples should be stored in refrigerated condition, and be analyzed in two weeks after sampling. The 95% confidence limit of the estimated total standard error for the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was ${\pm}12.6%$, ${\pm}12.5%$, ${\pm}14.0%$, and ${\pm}13.6%$, respectively, which satisfied the OSHA sampling and analytical criteria.

Development of Tunnel Convergence Measuring System (터널의 내공변위 계측 시스템 개발)

  • 정성혁;박찬홍;이재기
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.607-612
    • /
    • 2004
  • Together with the requirements of tunnels, its construction methods and technologies have been pretty much developed, but frequent accidents happened under the constructions are just one of important problems which should be improved. To detect the potential hazardous factors in or ahead of time, speedy and accurate measurement are absolutely required, but currently surveying method using tapes, level and total station, has been generally taken in measuring of tunnel convergence and crown. The purpose of this study is, as using of 'Industrial photogrammetry' system which is supplying more accuracy and speedy in the measure of tunnel convergence, aimed at promotion of tunnel measurement technique and development in unmanned automatic measuring system in the future finally.e finally.

  • PDF

Evaluation of the Method for Total Homocysteine in Plasma Using LC-MS/MS (LC-MS/MS를 이용한 Homocysteine 측정과 그 유용성 평가)

  • Jun, Sun-Hee;Lim, Mi-Suk;Jung, Yong-Sun;Song, Jung-Han
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.22-26
    • /
    • 2005
  • Total homocysteine is now considered a risk factor for cardiovascular diseases. I increased interest has led to a multitude of studies requiring the determination of total homocysteine in conjunction with other factor. There are various methods for measuring total homocysteine, including HPLC, FPIA, GC-MS and LC-MS/MS. The most recent method for measuring total homocysteine uses a deuterium-labelled internal standard and tandem mass spectrometry. This development requires no derivatization and therefore leads to an increase in sample throughput compared to other techniques. We have evaluated the method for homocysteine by the LC-MS/MS method, and the correlation between the FPIA method and the LC-MS/MS method. The standard curve (0, 5, 10, 20, 50, 100 uM) was linear over the range examined (up to 100 uM). The lower limit of quantification (CV < 10 %) was 0.5 uM/L and the lower limit of detection (S/N >3) was 0.1 uM/L. Intra-assay variation and inter-assay variation were both <6 %. The comparision study for homocysteine concentration showed good correlation (r=0.9684) between the FPIA method and LC-MS/MS methods. Our conclusion is that the method showed relatively good precision, and was rapid and accurate.

  • PDF

Development of Automatic Displacement Measuring System Using 3D Digital Photogrammetry Image and Its Application (수치사진영상을 이용한 자동 변위계측시스템의 개발과 적용)

  • Han, Jung-Geun;Kim, Young-Seok;Cho, Sam-Duk;Kwak, Ki-Seok;Hong, Ki-Kwon
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.5
    • /
    • pp.53-62
    • /
    • 2007
  • Recently, for the stabilization estimation of structures, many automatic measuring instruments with expensiveness and high accuracy have been developed and utilized. However, the existing manual measuring systems are almost impossible to measure the real-time for the whole surface of large-scale structures and an automatic measuring system has disadvantages with demanding enormous expense. In this study, 3D digital visual monitoring system was developed by using digital photogrammetry technique. To confirm application of developed system, it was applied to the measurement of the wall displacement of concrete surface and displacement measurement of reinforced-soil wall block. Then, the result of the test was compared with measuring value of total station. Based on the results of the comparison, the application of visual monitoring system was evaluated. The results show that the developed visual monitoring system could be available in displacement measure of structures.

The Accuracy of the ICD-10 Code for Trauma Patients Visiting on Emergency Department and the Error in the ICISS (응급센터에 내원한 외상 환자에 있어 ICD-10 (International Classification of Disease-10)입력의 정확성과 ICISS (International Classification of Disease Based Injury Severity Score)점수의 오류)

  • Lee, Jae Hyuk;Sim, Min Seob
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.108-115
    • /
    • 2009
  • Purpose: We designed a retrospective study to measure the accuracy of the ICD-10 (International Classification of Disease-10) code for trauma patients. We also analyzed the error of the ICISS (International Classification of Disease based Injury Severity Score) due to a missing or an incorrect ICD-10 code. Methods: For the measuring the accuracy of the ICD-10 code for trauma patients in a tertiary teaching hospital's emergency department, two board certified emergency physician performed a retrospective chart review. The ICD-10 code was classified as a main code or a sub-code. The main code was defined as the code of the main department of treatment, and the sub-code was defined as a code other than the main code. We calculated and compared two ICISS for each patient one by using both the existing code and the other by using a corrected code. We compared the proportions of severe trauma (defined as an ICISS less than 0.9) between when the existing code and the corrected code was used respectively. Results: We reviewed the records of 4287 trauma patients who had been treated from July 2008 to November 2008. The accuracy of the main code, the sub-code of emergency department, main-code, the sub-code of hospitalized patients were 97.1%, 59.8%, 98.2% and 57.0%, respectively. Total accuracy of the main and sub-code of emergency department and of hospitalized patients were 91.4% and 58.6%. The number of severe trauma patients increased from 33 to 49 when the corrected code was used in emergency department and increased from 35 to 60 in hospitalized patients. Conclusion: The accuracy of the sub-code was lower than that of the main code. A missing or incorrect subcode could cause an error in the ICISS and in the number of patients with severe trauma.

COMPARISON OF THE ACCURACY OF STONE CASTS MADE FROM ALGINATE IMPRESSION MATERIAL BY MIXING METHODS AND APPLICATION OF TRAY ADHESIVE (알지네이트 인상재의 혼합방법과 트레이 어드헤시브 도포에 따른 모형의 정확도 비교)

  • Kim Jin-Hyung;Chung Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.492-501
    • /
    • 2001
  • The use of alginate impression materials today is prevalent because of its efficiency and simplicity in clinical settings. Unfortunately, the simplicity of the procedure tends to lull the dentist into a sense of well-being, and lead him into using careless or sloppy technique. Alginate impression materials are used to fabricate diagnostic and preliminary casts, and the final cast. Incorrect use of this material is known to affect the accuracy of the final prosthesis. The purpose of this study was to compare the effect of different mixing methods of alginate impression material and tray adhesive on the accuracy of the stone cast produced by each method. A total of 30 stone casts were produced by using 3 different types of mixing methods (10 stone cast for each mixing method, respectively). The first method utilized an automatic-mixing machine to mix alginate while the second method was carried out manually, strictly following manufacturer's instructions. The third method also involved manual mixing, but did not follow the manufacturer's instructions and was done in a random fashion. Also, 20 additional stone casts were produced by using alginate with or without tray adhesives were included in the study to evaluate effects of tray adhesives on the accuracy of alginate impression. 10 stone casts were produced by adding tray adhesives to the interior surface of the impression tray prior to taking the impression. The other 10 excluded this step. A total of 50 stone casts were analyzed by the three-dimensional measuring machine to measure and compare the dimensional changes of the impression material of each group. The results are as follows. 1. No significant difference was found between the automatic mixing group and the manually-mixing group(p>0.05). 2. For the group that followed manufacturer's instructions, less dimensional changes were record ed than the group that didn't in measuring distanced 4(p<0.05). 3. The group that used tray adhesives showed less dimensional changes(p<0.05). The findings revealed that mechanical methods of mixing alginate impression materials had little influence on dimensional changes. However, it is proven that following manufacturers instructions in alginate impression taking is an important step in acquiring accurate impressions and tray adhesives may play an important role in enhancing the results.

  • PDF

Breast Cancer Screening Behaviors in Working Women (직장여성의 유방암 검진행위 분석)

  • Han, Mi-Yeoun;Chung, Chae-Weon
    • Women's Health Nursing
    • /
    • v.12 no.4
    • /
    • pp.363-370
    • /
    • 2006
  • Purpose: The aim of this study was to analyze breast cancer screening behaviors in working women. Method: A total of 354 women over 20 years of age were recruited from three major occupational settings by convenience sampling. The Champion's Health Beliefs Model Scale-Korean version and a structured questionnaire for measuring regularity and accuracy of breast self-examination(BSE) were used. Data were analyzed using descriptive statistics, $x^$-test, ANOVA, and Duncan post hoc tests. Result: Women who have performed BSE and had both BSE and clinical tests were 49.2% and 32.8%, respectively, while 36.7% of the participants had none of the screening. The screening patterns were significantly different by individual characteristics of age, occupation, experiences of breast disease, education at workplace, and by the level of confidence in health beliefs (p<.01, p<.05). Only 4 % of women performed BSE regularly and the level of accuracy of the BSE was very low as well. Conclusion: Education at the workplace needs to emphasize the recommended guidelines and further increase the quality and results of the BSE for women's health.

  • PDF