• 제목/요약/키워드: Total Knee Replacement Simulator

검색결과 2건 처리시간 0.023초

시뮬레이션을 이용한 슬관절 수술 변수 결정 (Determination of Total Knee Replacement Parameter by Simulation)

  • 윤영수;박세형;이수홍;최귀원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.881-887
    • /
    • 2005
  • A total knee replacement is an extremely 'position-sensitive' operation; a malposition or a malalignment of the components will lead to a breakage of the component, a fracture around the knee prosthesis, and the limitation of range of the motion, etc. In a conventional total knee replacement, surgeons have to select an appropriate prosthesis according to the shape of the surgical region. A wrong selection may give rise to side effects or to need re-operation. Nevertheless, it is so difficult to choose the most proper prosthesis out of various kinds of prosthesis. This paper presents a surgical planning system for the total knee replacement with an operation simulating method in order to determine the parameters for the total knee replacement operation. We select an alignment axis and a resection angle as major operation parameters in the total knee replacement operation, and introduce the method to determine the major operation parameters with the operation simulator we developed. The simulator is used to determine operation parameters for optimized operations, to select the most appropriate prosthesis, and to analyze the prospective problems of the operation.

  • PDF

인공발목관절의 표면 마모 특성 (Surface Tribology of Total Ankle Joint Replacement)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF