• Title/Summary/Keyword: Total Inspection

Search Result 733, Processing Time 0.031 seconds

Report on the Hitchhiker Insect Pests detected from the Foreign Vessels Entering into Korea II (국외에서 출항한 국내 입항 선박에서 검출된 한국 미분포 편승자 해충에 대한 보고 II)

  • Kang, Tae Hwa;Kim, Sang Woong;Hong, Ki-Jeong;Kim, Nam Hee;Cho, Il Kyu;Choi, Deuk-Soo
    • Korean journal of applied entomology
    • /
    • v.60 no.3
    • /
    • pp.269-276
    • /
    • 2021
  • During 15 months from 13. Jul. 2018 to 29. Oct. 2019, we monitored on the hitchhiker insect pests from a total of 306 foreign vessels entering into Korea. As the results, a total of 805 samples of the hitchhiker insects were collected using simply collecting method by hands and identified as 379 species of 78 families under 12 orders on the basis of integrative species identification. Among them, 42 species (67 individuals) of 21 families under seven orders were detected as not-distributed species in South Korea. Of the 42 not-distributed species, seven species were multiply detected in 2018 and 2019, and two species, Erthesina fullo (Pentatomidae, Hemiptera) and Tessaratoma papilosa (Tessaratomidae, Hemiptera) were discovered as regulated insect pest. Therefore, we reported on the 42 not-distributed species in South Korea with the data sheets for the establishment of a monitoring plan on the not-distributed species and the risk assessments on invasive or invasive likelihood species.

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF

Evaluation of the Economic Value of Potential Ecosystem Services of Unexecuted Urban Planning Facilities - Focused on Urban Green Spaces and Urban Forests in Seoul - (미집행 도시계획시설의 잠재적 생태계 서비스 가치평가 - 서울시 공원 및 녹지를 중심으로 -)

  • Park, Jin-Han;Kim, Song-Yi;Heo, Han-Kyul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.4
    • /
    • pp.24-32
    • /
    • 2019
  • According to the Ministry of Land, Infrastructure, and Transport, the total area of unexecuted urban planning facilities in Korea is about $1,257km^2$, of which 47% is the unexecuted urban green space and forests. In the case of Seoul, the total area of unexecuted urban planning facilities is about $66km^2$, which is 5.24% of the total unexecuted area in the entire country. In Seoul, approximately 88% of the total unexecuted area is urban green space and forests, which is higher than the national rate. About 92% of the unexecuted urban planning facilities are long-term unexecuted urban planning facilities that are more than 10 years old. This study assessed the economic value of potential ecosystem services, focusing on the regulation service, supporting service, and cultural service, for urban green space and forests of unexecuted urban planning facilities in Seoul by using meta-regression analysis. As a result, the value of the regulation service provided by the urban green space and forests in Seoul was about 16.39 billion KRW, the value of the supporting service was about 5.8 billion KRW, and the cultural service value was about 7.78 billion KRW. The total value of ecosystem services is about 33.93 billion KRW. The values of regulation service and cultural service were the highest, and that was attributed to the characteristics of the downtown area. The significance of this study is to evaluate the value of ecosystem services for unexecuted urban planning facilities in Seoul. The results of this study can be used not only in the process of urban planning or policymaking but also land compensation methods applying the concept of an ecosystem service payment system.

Natural Occurrence of Fumonisin $B_{1}$ and $B_{2}$ in Corns Imported from U.S.A (미국산 옥수수의 Fumonisin $B_{1}$$B_{2}$ 오염현황)

  • Yu, Chun-Cheol;Oh, Deog-Hwan;Park, Boo-Kil
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.875-879
    • /
    • 1999
  • Eighty corn samples, which imported from U.S.A between 1995 and 1996, were analyzed for fumonisin $B_{1}\;(FB_{1})$ and $B_{2}\;(FB_{2})$ contamination. The total fumonisin level and mean from 80 imported samples showed 0(limited detection level)-$65.9\;{\mu}g/g$ mgand $6.9\;{\mu}g/g$, respectively. $FB_{1}$ was detect in 57 (71.3%) from 80 samples at the concentrations ranging from 0 to $48.8\;{\mu}g/g$, while $FB_{2}$ was detected in 49(61.3%) at concentrations ranging from 0 to $17.1\;{\mu}g/g$. The total fumonisin incidence analyzed from 80 samples were 37.5%, 42.6 and 19.9% for concentrations ranging from below $1\;{\mu}g/g$, between 1.1 and $10\;{\mu}g/g$ and above $30\;{\mu}g/g$, respectively. The total fumonisin level containing below $1\;{\mu}g/g$ from samples imported in 1995 and 1996 was 47.7% (21/44) and 29.4 (10/34), while total fumonisin level containing above $10{\mu}g/g$ was 47.77% (21/44) and 29.4 (10/34), respectively. In the meanwhile, the fumonisin $B_{1}$ and $B_{2}$ containing below $1\;{\mu}g/g$ from 80 samples imported between 1995 and 1996 was 38.8% and 67.5%, while fumonisin $B_{1}$ and $B_{2}$ containing above $10{\mu}g/g$ was 12.5% and 5%, respectively.

  • PDF

Analysis of Neurological Complications on Antegrade Versus Retrograde Cerebral Perfusion in the Surgical Treatment of Aortic Dissection (대동맥 박리에서 전방성 뇌 관류와 역행성 뇌 관류의 신경학적 분석)

  • Park Il;Kim Kyu Tae;Lee Jong Tae;Chang Bong Hyun;Lee Eung Bae;Cho Joon Yong
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.489-495
    • /
    • 2005
  • In the surgical treatment of aortic dissection, aortic arch replacement under total circulatory arrest is often performed after careful inspection to determine the severity of disease progression. Under circulatory arrest, antegrade or retrograde cerebral perfusion is required for brain protection. Recently, antegrade cerebral perfusion has been used more, because of the limitation of retrograde cerebral perfusion. This study is to compare these two methods especially in the respect to neurological complications. Material and Method: Forty patients with aortic dissection involving aortic arch from May 2000 to May 2004 were enrolled in this study, and the methods of operation, clinical recovery, and neurological complications were retrospectively reviewed. Result: In the ACP (antegrade cerebral perfusion) group, axillary artery cannulation was performed in 10 out of 15 cases. In the RCP (retrograde cerebral perfusion) group, femoral artery Cannulation was performed in 24 out of 25 cases. The average esophageal and rectal temperature under total circulatory arrest was $17.2^{\circ}C\;and\;22.8^{\circ}C$ in the group A, and $16.0^{\circ}C\;and\;19.7^{\circ}C$ in the group B, respectively. Higher temperature in the ACP group may have brought the shorter operation and cardiopulmonary bypass time. However, the length of period for postoperative clinical recovery and admission duration did not show any statistically significant differences. Eleven out of the total 15 cases in the ACP group and thirteen out of the total 25 cases in the RCP group showed neurological complication but did not show statistically significant difference. In each group, there were 5 cases with permanent neurological complications. All 5 cases in the ACP group showed some improvements that enabled routine exercise. However all 5 cases in RCP group did not show significant improvements. Conclusion: The Antegrade, cerebral perfusion, which maintains orthordromic circulation, brings moderate degree of hypothermia and, therefore, shortens the operation time and cardiopulmonary bypass time. We concluded that Antegrade cerebral perfusion is safe and can be used widely under total circulatory arrest.

Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석)

  • Ha, Soo-Kyoung;Son, Guk-Won;Yu, Sung-Yong;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.18-28
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of U-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D, agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

Cross-sectional Survey for Prevalence Rate of Scoliosis in Primary, Middle and High School Boys in Pusan City (부산시내 남자 초.중.고등학생의 척추측만증 유병률 측정을 위한 단면조사)

  • Kim, Bok-Yong;Park, Jung-Han;Kim, Poong-Taek
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.217-223
    • /
    • 1988
  • A cross-sectional survey was conducted to determine the prevalence rate of scoliosis in elementary, middle and high school boys in May 1988. The study population included 1,393 male students in Pusan ; 463 students of 4th grade in two elementary schools, 543 students of 1st grade in one middle school and 387 students of 1st grade in one high school. The students of elementary school were screened with inspection by two physicians at the same time and the students of middle and high schools were screened with both inspection by the same physicians and 70mm chest X-ray. Positive students in any one of the two screening tests were measured for height and body weight and asked for the shoulder side on which he carries the school bag. The angle of curvature on X-ray film was measured by Cobb's method. The number of positive students in any one of the two screening tests were 15(3.2%) in elementary schools, 174(32.0%) in middle school and 92(23.8%) in high school. However, positive rates in both tests were only 2.2% for the middle school students and 2.6% for the high school students and among these students 1.1% out of total middle school students and 2.3% of high school students had a curvature equal to or greater than $5^{\circ}$ of Cobb's angle on 70mm chest X-ray film. There was a statistically significant association between the direction of spinal curve and the shoulder side on which one carries school bag among positive students in both screening 1.sts (p<0.05) Mean height and body weight of 281 positive students in any one of two screening tests were compared with the Korean standard for the same age. Mean weight of elementary school students was nearly the same as the standard weight but the height was slightly shorter than the standard. However, both mean height and weight of the middle school students were lower than the standard while those of the high school students were higher. The prevalence rate of scoliosis for the 2nd and 3rd grades of high school is presumed to be higher than that of the 1st grade of high school and the rate for girls will be even higher than the rate for boys of the same age. Thus, scoliosis seems to be an important school health problem. To prevent scoliosis, it is recommeded to reduce the weight of school bag, educate the students to keep a right posture and exercise periodically.

  • PDF

An Experimental Study on Evaluation of Axially Compressive Buckling Strength of Corroded Temporary Steel (부식 손상된 가시설 강재의 축압축 좌굴강도 추정에 관한 실험적 연구)

  • Kim, In Tae;Lee, Myoung Jin;Shin, Chang Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.135-146
    • /
    • 2011
  • Steel structures have been generally painted to prevent corrosion damage. However, the painted film is deteriorated with increase in service life, and then corrosion damage resulting in cross sectional area occurs on steel surface. As a result, the buckling strength of steel structures can be decreased due to the corrosion damages. The evaluation method of the axial buckling strength of columns about a variety of section shapes and supporting conditions have been presented, but evaluation method of buckling strength about irregular nonprismatic columns is not established. In this study, the axial buckling strength of corroded steels was evaluated based on the buckling test results of corroded steel specimens that were cut off at a temporary steel structure. The corroded specimens were picked up total 10 specimens according to various slenderness ratio from the web of a temporary structure's main beam. The length of specimens is 200, 300, 400, 500 and 600mm respectively. The rust productions were removed by the chemical treatment. Then, the surface geometry was measured at intervals of $1{\times}1mm$ by using the optical 3D digitizing system, and the residual thickness of the specimens was calculated. The axial buckling test was performed on 10 corroded specimens and 12 non-corroded specimens under the fixed-fixed support condition. From the test results, the effect of corrosion damages on axial buckling load was investigated. Regardless of corrosion damage degree, the axial buckling strength of corroded specimens and non-corroded specimens was evaluated identically by using minimum average residual thickness or average residual thickness to minus its standard deviation. Reasonable measuring intervals of residual thickness was proposed by using the results to apply for practical works.

Comparison Analysis of The results of IRMA Test among Different Equipment According to Algorithm change. (IRMA 검사법 중 알고리즘 변경에 따른 장비 간 결과값 비교분석)

  • Kim, Jung In;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.43-50
    • /
    • 2019
  • Purpose The principle of nuclear medicine test is divided into two main categories: competition(radioimmunoassay, RIA) and noncompetitive reaction(Immunoradiometric assay, IRMA). It is known that the curve fitting method, which is commonly used in inspection field, uses Spline interpolation in RIA method and Linear interpolation method in IRMA method. Among them, the insulin test using the IRMA test showed a significant difference, especially at low concentrations, despite the same algorithm of linear interpolation between fully automated radio immunoassay analyzers. In this study, we aim to obtain results from applying two different of algorithm using fully automated radio immunoassay analyzers including Gamma pro, Gamma 10, Cobra, and SR300. Materials and Methods A total of 30 test samples were selected for the test of TSH, ferritin, C-peptide, and insulin serum levels. Test was performed by IRMA method. We compared the difference in the results of applying the linear interpolation method and the spline interpolation method to Gamma Pro, Gamma 10, Cobra, and SR300 equipment. Results Two-way ANOVA was used for statistical analysis. The significance level was applied as P <0.05. The results of TSH, ferritin, C-peptide, and insulin tests were compared between the fully automated radio immunoassay analyzers. There was a significant difference between ferritin, C-peptide, and insulin serum levels(P<0.001). TSH didn't show any significant different between the devices(P=0.29). In the difference between linear and spline interpolation, there was no significant difference between insulin test(P=0.08), TSH test(P=0.81), and Ferritin test(P=0.06). However, C-peptide test showed a significant difference(P=0.03). Especially, the insulin test showed significant difference in lower ranges. As a result of comparing and analyzing the difference between the two interpolation methods, the devices in the low concentration group showed significant difference(P<0.001). Conclusion In case of new equipment in the laboratory it is necessary to recognize that there is a difference in the curve fitting method for each automated radio immunoassay analyzers in the low concentration area when the principle of inspection is IRMA method.

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.