• Title/Summary/Keyword: Total Flow Control

Search Result 586, Processing Time 0.027 seconds

A scheduling algorithm for ASIC design (ASIC 설계를 위한 스케쥴링 알고리듬)

  • 김기현;정정화
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.7
    • /
    • pp.104-114
    • /
    • 1995
  • In this paper, an intermediate representation HSFG(Hanyang Sequential Flow GRaph) and a new scheduling algorithm for the control-dominated ASIC design is presented. The HSFG represents control flow, data dependency and such constraints as resource constraints and timing constraints. The scheduling algorithm minimizes the total operating time by reducing the number of the constraints as maximal as possible, searching a few paths among all the paths produced by conditional branches. The constraints are substitute by subgraphs, and then the number of subgraphs (that is the number kof the constraints) is minimized by using the inclusion and overlap relation among subgraphs. The proposed algorithm has achieved the better results than the previous ones on the benchmark data.

  • PDF

Loading Rates and Characteristics of Litter from Highway Stormwater Runoff (강우로 인해 고속도로로부터 유출되는 폐기물의 성상, 부하량 및 유출 특성)

  • Kim, Lee-Hyung;Kang, Joohyon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.415-421
    • /
    • 2004
  • Litter wastes on highway runoff are gradually being considered one of the major pollutants of concern in protecting the integrity of receiving waters for beneficial use. The California State Water Resources Control Board has identified in their 303(d) list at least 36 water bodies where trash or litter is considered a pollutant of concern. The first TMDL adopted by the Region 4 (Los Angeles area) of the California State Water Quality Control Board was for trash in the Los Angeles River. The first flush characteristic study was developed to obtain first flush water quality and litter data from representative stormwater runoff from standard highway drainage outfalls in the Los Angeles area. Total captured gross pollutants in stormwater runoff were monitored at six Southern California highway sites over two years. The gross pollutants were 90% vegetation and 10% litter. Approximately 50% of the litter was composed of biodegradable materials. The event mean concentrations show an increasing trend with antecedent dry days and a decreasing trend with total runoff volume or total rainfall. Event mean concentrations were ranged 0.0021 to 0.259g/L for wet gross pollutants and 0.0001 to 0.027g/L for wet litters. The first flush phenomenon was evaluated and the impacts of various parameters such as rainfall intensity, drainage area, peak flow rate, and antecedent dry period on litter volume and loading rates were evaluated. First flush phenomenon was generally observed for litter concentrations, but was not apparent with litter mass loading rates. Litter volume and loading rates appear to be directly related to peak storm intensity, antecedent dry days and total flow volume.

Numerical Studies of a Separator for Stack Temperature Control in a Molten Carbonate Fuel Cell (용융탄산염 연료전지 스택 온도 조절을 위한 분리판에 관한 수치 해석 연구)

  • Kim, Do-Hyung;Kim, Beom-Joo;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.3
    • /
    • pp.305-312
    • /
    • 2011
  • The use of a separator to control stack temperature in a molten carbonate fuel cell was studied by numerical simulation using a computational fluid dynamics code. The stack model assumed steady-state and constant-load operation of a co-flow stack with an external reformer at atmospheric pressure. Representing a conventional cell type, separators with two flow paths, one each for the anode and cathode gas, were simulated under conditions in which the cathode gas was composed of either air and carbon dioxide (case I) or oxygen and carbon dioxide (case II). The results showed that the average cell potential in case II was higher than that in case I due to the higher partial pressures of oxygen and carbon dioxide in the cathode gas. This result indicates that the amount of heat released during the electrochemical reactions was less for case II than for case I under the same load. However, simulated results showed that the maximum stack temperature in case I was lower than that in case II due to a reduction in the total flow rate of the cathode gas. To control the stack temperature and retain a high cell potential, we proposed the use of a separator with three flow paths (case III); two flow paths for the electrodes and a path in the center of the separator for the flow of nitrogen for cooling. The simulated results for case III showed that the average cell potential was similar to that in case II, indicating that the amount of heat released in the stack was similar to that in case II, and that the maximum stack temperature was the lowest of the three cases due to the nitrogen gas flow in the center of the separator. In summary, the simulated results showed that the use of a separator with three flow paths enabled temperature control in a co-flow stack with an external reformer at atmospheric pressure.

Effect of Mori Folium Extract on Improvement of Blood Flow in Ferric Chloride-Induced Carotid Artery Damage Rat Model (염화제2철이 유도하는 경동맥 손상 렛트 모델에서 상엽 추출물의 혈행개선 효과)

  • Kang, Hyun Ju;Jeon, In Hwa;Kwon, Tae Oh;Choi, Jiwon;Kim, Sung Zoo;Jang, Seon Il
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.607-613
    • /
    • 2014
  • In a previous study, we have shown that mulberry leaves (Mori Folium) extract MFE) and its compounds have the antioxidant effect in human red blood cells. However, the possible effect of MFE and its compounds on improvement of blood flow were not reported. Therefore, the aim of this study is to investigate the effects of MFE and its compounds on improvement of blood flow in a rat model of topical ferric chloride ($FeCl_3$)-induced carotid artery damage. The $FeCl_3$ treatment seriously damaged the carotid artery: the walls of the artery, blood flow rate, blood vessel diameter, blood vessel area and blood flow amount. However, administration of MFE or its compound has ameliorated the blood flow and suppressed thrombus in blood vessels. Moreover, the concentrations of serum total cholesterol, triglycerides, and LDL cholesterol in the MET and its compound groups were remarkably reduced in comparison to the control group, and HDL cholesterol concentration was higher in the MET and its compound groups than in the control group. These results suggest that MFE and its compounds ameliorate the thrombosis against blood vessel damage.

Characteristics of Pollutant Concentrations in Runoff Water from a Small Rural Watershed (농촌 소유역 유출수의 오염물질 농도특성)

  • Oh, Kwang-Young;Kim, Jin-Soo;Cho, Jae-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.2
    • /
    • pp.99-108
    • /
    • 2007
  • The purpose of this study was to investigate characteristics of concentrations of pollutants such as TN (Total Nitrogen), TP (Total Phosphorus) and COD (Chemical Oxygen Demand) in outflow from a nonpoint source dominated watershed ($6.7km^2$). Regular flow measurement and water sampling were taken at five-day intervals during two years (February 2002 to January 2004) in the Ingyeong River, a tributary of the Han River. The mean concentrations of pollutants during rainy days were significantly (p<0.05) higher than those during dry days. For dry days, the flow-weighted mean concentration (0.06 mg/L) of TP during paddy irrigation periods were higher than that (0.02 mg/L) during non-irrigation periods. The seasonal mean concentration of TN was highest in spring likely due to nitrogen fertilization, but those of TP and COD were highest in summer due to particulate phosphorus and sediment-associated organic matter caused by increased discharge. The pollutant concentrations significantly increased with discharge, suggesting that the measures to reduce the increase in the concentrations during storms are needed to control nonpoint source pollution.

Influence of Controlling Protozoa on the Degradation and Utilization of Dietary Fibre and Protein in the Rumen and Nitrogenous Flow Entering the Duodenum of Sheep

  • Han, C.Y.;Lu, D.X.;Hu, M.;Tan, Z.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.8
    • /
    • pp.1241-1245
    • /
    • 1999
  • Nine two-year old sheep fitted with rumen and duodenum cannulas were used to study the effect of controlling protozoa flora on the degradation and utilization of dietary fibre and protein in the rumen and on nitrogenous flow to the duodenum. There were three groups in this experiment: defaunation (DF); partial defaunation (PDF); faunation (F) as control. Results showed that: 1,There were no differences between treatments in dietary DM degradation in the rumen, but defaunation and partial defaunation increased the quantity of nitrogenous material in the rumen and the flow of N to duodenum. 2, partial defaunation and defaunation improved the degradabilities of dietary NDF, ADF and HC, but there were no differences between the defaunated and partially defaunated groups. 3, Partial defaunation decreased the degradability of dietary protein in the rumen. There was no difference between defaunated and faunated groups. 4, Defaunation and partial defaunation increased the quantity of total N (TN) and microbial N (MCN) in the rumen and the amounts entering the duodenum. The protozoa N (PN) flow in the faunated group was higher than that in the partially defaunated group, and the amino acid pattern in the digesta at the proximal duodenum in the defaunated group was closer to the ideal amino acid pattern. 5, There were differences in the mole percent of acetic, propionic, total-VFAs and the non-glucogenic to glucogenic VFAs ratio (NGR) value in the rumen fluids. The order was as follows: mole percent of acetate: F>PDF>DF; mole percent of propionate: DF>PDF>F; total-VFAs: PDF>F>DF; NGR: F>PDF>DF.

A Study on the Early Diagnosis of Pneumoconiosis (진폐증의 조기진단에 관한 연구)

  • Lim, Young;Yun, Im-Goung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.3 s.31
    • /
    • pp.262-273
    • /
    • 1990
  • In order to assess the method which is more sensitive one to detect the early change of lung tissue by the inhaled dust, we have performed the various medical examinations such as chest radiography, pulmonary function test, high resolution chest CT, brnchoalveolar lavage and lung biopsy used bronchoscope and ultrathin bronchoscopy examination to 48 persons. The control group were 8 persons who did not exposed to dust, 40 cases of the experimental group have professionally exposed to the mineral dust. The results were as follows 1. The total number of cells in bronchoalveolar lavage was significantly increased in all of the pneumoconiosis group classified by chest and high resolution chest CT. 2. The composition rate of macrophage to the total number of cells in bronchoalveolar lavage fluid was significantly decreased in all of the pneumoconiosis group compared with the control group. 3. The composition rate of neutophils and lymphocytes to the total number of cells in bronchoalveolar lavage fluid was significantly increased in all of the pneumoconiosis group compared with the control group. 4. The forced expiratory volume in one second ($FEV_{1-0}$), maximal mid-expiratory flow (MMF), and maximal voluntary ventilation (MVV) were significantly increased only in the group of the progressed pneumoconiosis relatively. 5. We observed submucosal edema, anthracotic pigmentation and granuloma formation in transbronchial lung biopsy of the suspected pneumoconiosis (category 0/1) case which is thought to the early change of coal workers' pneumoconiosis.

  • PDF

A Study on Multi Level Load Shedding Control Scheme Strategy for Stabilization of the Korean Power System (국내 전력계통 안정화를 위한 다단계 부하차단 제어전략 수립에 관한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • Korean Power System are operating a load shedding system to prevent voltage instability phenomenon caused by severe line contingencies. In order to apply the load shedding scheme should be selected a location, amount, delay time. Current load shedding system is load shedding amount that has been calculated in the steady-state analysis to load shed the total amount in first level, load shedding amount calculated in advance, it is possible to perform an unnecessary load shedding. In this paper, set a multi-level load shedding control strategy step-by-step selection of load shedding amount for the prevention of excessive load shedding. In addition, through a voltage resilience analysis of the power system by applying motor load ratio and sensitivity parameter to selection the multi level load shedding ratio and delay time. For this reason, to take advantage of the limit data of interchange power, by utilizing interface power flow data to set a multi-level load shedding control strategy for the stabilization of the Korean Power System.

An Interference Reduction Scheme Using AP Aggregation and Transmit Power Control on OpenFlow-based WLAN (OpenFlow가 적용된 무선랜 환경에서 AP 집단화 및 전송 파워 조절에 기반한 간섭 완화 기법)

  • Do, Mi-Rim;Chung, Sang-Hwa;Ahn, Chang-Woo
    • Journal of KIISE
    • /
    • v.42 no.10
    • /
    • pp.1254-1267
    • /
    • 2015
  • Recently, excessive installations of APs have caused WLAN interference, and many techniques have been suggested to solve this problem. The AP aggregation technique serves to reduce active APs by moving station connections to a certain AP. Since this technique forcibly moves station connections, the transmission performance of some stations may deteriorate. The AP transmit power control technique may cause station disconnection or deterioration of transmission performance when power is reduced under a certain level. The combination of these two techniques can reduce interference through AP aggregation and narrow the range of interferences further through detailed power adjustment. However, simply combining these techniques may decrease the probability of power adjustment after aggregation and increase station disconnections upon power control. As a result, improvement in performance may be insignificant. Hence, this study suggests a scheme to combine the AP aggregation and the AP transmit power control techniques in OpenFlow-based WLAN to ameliorate the disadvantages of each technique and to reduce interferences efficiently by performing aggregation for the purpose of increasing the probability of adjusting transmission power. Simulations reveal that the average transmission delay of the suggested scheme is reduced by as much as 12.8% compared to the aggregation scheme and by as much as 18.1% compared to the power control scheme. The packet loss rate due to interference is reduced by as much as 24.9% compared to the aggregation scheme and by as much as 46.7% compared to the power control scheme. In addition, the aggregation scheme and the power control scheme decrease the throughput of several stations as a side effect, but our scheme increases the total data throughput without decreasing the throughput of each station.

Calculation of 3-Dimensional Flow Through an Impeller of Centrifugal Compressor (원심압축기 회전차 내부의 3차원 유동해석)

  • ;;Kang, S. H.;Jeon, S. G.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2617-2629
    • /
    • 1995
  • The flow through a centrifugal compressor rotor was calculated using the quasi-3-dimensional and fully 3-dimensional Navier-Stokes solution methods. The calculated results, obtained during the development of the computer codes for both methods are discussed. In the inviscid quasi 3-dimensional analysis, stream function formulation was used for the blade to blade (B-B) plane calculations, and the streamline curvature method was used for the meridional (H-S) plane calculations. In the viscous 3-dimensional flow analysis, a control volume method based on a general rotating curvilinear coordinate system was used to solve the time-averaged Navier-Stokes equations, and a standard k-.epsilon. model was used to obtain eddy viscosity. The quasi-3-dimensional analysis reasonably predicts the pressure distributions and requires much less computation time in the region where viscous effects are not strong; however, it fails to predict velocity field and loss mechanism through the impeller passage. The viscous 3-dimensional flow analysis shows reasonable pressure distributions and typical jet-wake flow field through the impeller passage. Secondary flow and total pressure distributions on cross-sectional planes explain the loss mechanisms through the impeller.