• 제목/요약/키워드: Total Flow Control

검색결과 584건 처리시간 0.04초

Joint Scheduling and Flow Control for Multi-hop Cognitive Radio Network with Spectrum Underlay

  • Quang, Nguyen Tran;Dang, Duc Ngoc Minh;Hong, Choong-Seon
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2012년도 한국컴퓨터종합학술대회논문집 Vol.39 No.1(D)
    • /
    • pp.297-299
    • /
    • 2012
  • In this paper, we introduce a joint flow control and scheduling algorithm for multi-hop cognitive radio networks with spectrum underlay. Our proposed algorithm maximizes the total utility of secondary users while stabilizing the cognitive radio network and still satisfies the total interference from secondary users to primary network is less than an accepted level. Based on Lyapunov optimization technique, we show that our scheme is arbitrarily close to the optimal.

보일러 급수펌프용 1500lb 고차압 제어밸브 유량시험 및 수치해석에 관한 연구 (A Study on the Flow Coefficient Test and Numerical Analysis about 1500lb High-Pressure Drop Control Valve for Boiler Feedwater Pump)

  • 이권일;장훈;이치우
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.541-547
    • /
    • 2022
  • Before making a prototype, we predicted the inlet/outlet differential pressure and flow coefficient, which are the most basic design data for the valve through the design and numerical analysis of the trim, which is the most important in the localization development of the 1500Ib high differential pressure control valve used for boiler feed water. As a result, the design value and the analysis value were found to be about 98% similar. The flow field within the fluid velocity of 23m/s to prevent cavitation was also found. The result of the numerical analysis on thermal stress due to the characteristics of valves exposed to high temperatures showed that it was found to be about 18% less than the allowable stress of the bolt fixing the trim. When all loads such as pressure, self-weight, and vibration are applied, however, it is judged to go beyond the currently calculated thermal stress, exceeding the allowable stress.

Cardioplegic Solution의 심근보호 효과에 관한 실험적 연구 (An Experimental Study on the Myocardial Protection Effects of the Cardioplegic Solution)

  • 이종국
    • Journal of Chest Surgery
    • /
    • 제13권4호
    • /
    • pp.321-337
    • /
    • 1980
  • The increasing use of cardioplegic solution for the reduction of ischemic tissue injury requires that all cardiplegic solution be carefully assessed for any protective or damaging properties. This study describes functional, enzymatic and structural assessment of the efficiency of three cardioplegic solutions (Young & GIK, Bretschneider, and $K^{+}$ Albumin solution) in a Modified Isolated Rat Heart Model of cardiopulmonary bypass and ischemic arrest. Isolated rat heart were subjected to a 2-minute period of coronary infusion with a cold cardioplegic or a noncardioplegic solution immediately before and also at the midpoint of a 60-minute period of hypothermic ($10{\pm}1$. C) ischemic cardiac arrest. The results of this study were as follow: 1. Spontaneous heart beat after ischemic arrest occured 16 seconds later after Langendorff reperfusion in the Young & GIK group (n=6), and 40 second later in the Bretschneider group (n=6) and 6 minute later in the $K^{+}$ Albumin group (n=6), and 16 minute later in the control group (non-cardioplegia). A good recovery state of spontaneous heart beat was shown in the Young & GIK and Bretschneider groups. 2. The percentage of recorveries of heart function at 30 minute after postischemic working heart perfusion were : heart rate $91.6{\pm}3.1$% (P<0.01)m oeaj airtuc oressyre $83{\pm}3$% (P<0.01), coronary flow $70{\pm}8$% (P<0.05) and aortic flow flow rate $39{\pm}9.3$% (P<0.05) in the Young & GIK group. This percentage of recoveries of the Young & GIK group was significantly greater than the control group. In the Bretschneider group, the percentage of recoveries were : heart rate $87.8{\pm}7.5$%(P<0.05), peak aortic pressure $71{\pm}2.3$% (P<0.05) and aortic flow rate $33.2{\pm}6.6$%(P<0.05). hte percentage of recoveries were significantly greater than in the control group. In the $K^{+}$ Albumin group, recoveries of heart function were poor. 3. Total CPK leakage was $131.2{\pm}12.75$IU/30 min/gm. dry weight in the control group, $50.65{\pm}12.75$IU in the Young & GIK gruop, $69.40{\pm}32.21$Iu in Bretschneider group, and $103.65{\pm}15.47$IU in the $K^{+}$ Albumin group during the 30 minute postischemic Langendorff reperfusion. Total CPK leakage was significantly less (P<0.001) in the Young & GIK group, than in the control group. 4. Direct correlatin between percentage recovery of aortic flow rate and total amount of CPK leakage from Myocardium was noticed.(Correlation Coefficient r = 0.76, P<0.001). 5. Mild perivascular edema was the only finding of light microscopic study of myocardium after 60 minute ischemic arrest with cold cardioplegic solutions and hypothermla.

  • PDF

감조하천에서의 저수위 유량산정 다중회귀식 개발 (Development of Regression Equation for Water Quantity Estimation in a Tidal River)

  • 이상진;류경식;이배성;윤종수
    • 한국물환경학회지
    • /
    • 제23권3호
    • /
    • pp.385-390
    • /
    • 2007
  • Reliable flow measurement for dry season is very important to set up the in-stream flow exactly and total maximum daily load control program in the basin. Especially, in the points which tidal current effects are dominant because reliability of the low measurement decrease. The reliable measuring methods are needed. In this study, we analysis the water surface elevation difference of water surface elevation. Quantity relationship to consider tidal currents in these regions. It is known that tidal current effects from Nakdong river barrage are dominant in Samrangjin measuring station. We developed multiple regression equation with water surface elevation, quantity, and difference of water surface elevation and compared these results water measured rating curve. All of these regression equation including linear regression equation and log regression equation fits better measured data them existing water surface elevation quantity line and Among three equations, the log regression equation is best to represent the measured the rating curve in Samrangjin point. The log regression equation is useful method to obtain the quantity in the regions which tidal currents are dominant.

홍수조절용량 설정에 따른 증고저수지의 용수공급능력 변화 (Affecting Water Supply Capacity Followed by Allocating Flood Control Volume in Heightening Reservoir)

  • 노재경
    • 한국관개배수논문집
    • /
    • 제17권2호
    • /
    • pp.57-70
    • /
    • 2010
  • This study was performed to analyze the affect of water supply capacity followed by allocating flood control volume in heightening reservoir, of which Baekgog reservoir was selected as a case study in here. Baekgog reservoir is located in Jincheon county, Chungbuk province, of which full water level will be heightened from EL. 100. 1m to EL. 102.1m, and total storage from 21.75M $m^3$ to 26.67M $m^3$. Flood inflow with 200year frequency was estimated to 997 $m^3$/s in peak flow and 22.54M $m^3$ in total volume. Reservoir flood routing was conducted to determine flood limited water levels, which was determined to have scenarios such as EL 97-98-99m in periods of 6.21.-7.20., 7.21.-8.20., and 8.21.-9.20., respectively, EL 97-97-97m, EL 98-98-98m in present reservoir, and EL 99-100-101m, EL 99-99-99m, and EL 100-100-100m in heightened reservoir. Reservoir inflow was simulated by DAWAST model. Annual paddy irrigation requirement was estimated to 33.19M $m^3$ to 2,975ha. Instream flow was allocated to 0.14mm/d from October to April. Operation rule curve was drawn using inflow, irrigation and instream flow requirements data. In case of withdrawal limit reservoir operation using operation rule curve, reduction rates of annual irrigation supply before and after flood control by reservoir were 2.0~4.3% in present size and 1.5~3.6% in heightened size. Reliability on water supply was decreased from 77.3% to 63.6~68.2% in present size and from 81.6% to 72.7~79.5% in heightened size. And reduction rates of water storage at the end of year before and after flood control by reservoir were 7.3~16.5% in present size and 7.7~16.9% in heightened size. But water supplies were done without any water deficiency through withdrawal limit reservoir operation in spite of low flood regulating water level.

  • PDF

Assessment of Total Transfer Capability Using IPLAN: An Application of UPFC for Total Transfer Capability Enhancement

  • Lee Byung Ha;Kim Jung-Hoon;Kwak No-Hong;Lee Woon-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.244-251
    • /
    • 2005
  • Power transfer capability has been recently highlighted as a key issue in many utilities. It is determined by the thermal stability, dynamic stability and voltage stability limits of generation and transmission systems. In particular, voltage stability affects power transfer capability to a great extent in many power systems. This paper presents a tool for determining total transfer capability from a static voltage stability viewpoint using IPLAN, which is a high level language used with the PSS/E program. The tool was developed so as to analyze static voltage stability and to determine the total transfer capability between different areas from a static voltage stability viewpoint by tracing stationary behaviors of power systems. A unified power flow controller (UPFC) is applied for enhancing total transfer capability between different areas from the viewpoint of static voltage stability. Evaluation of the total transfer capability of a practical KEPCO power system is performed from the point of view of static voltage stability, and the effect of enhancing the total transfer capability by UPFC is analyzed.

최적조류계산을 기초로한 총송전용량 결정 (Total Transfer Capability Based on Optimal Power Flow)

  • 김규호;송경빈;이상봉;이상근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.570-571
    • /
    • 2008
  • This paper presents a method for the determination of total transfer capability in interconnected power systems, which is based on sequential quadratic programming (SQP). The objective function is the maximization of the interconnected line flow. To calculate TTC the control variables are the active power of the generating units, the voltage magnitude of the generator, transformer tap settings and SVC setting. The state variables are the bus voltage magnitude, the reactive power of the generating unit, line flows and the tie line flow. The method proposed is applied to the modified IEEE 14 buses model system.

  • PDF

1단 터빈 내 앞전 변형의 영향 하에 공력 특성에 대한 비정상 수치해석적 연구 (Numerical Study on the Unsteady Flow Characteristics under the Effect of Blade Leading Edge Modification in the 1st Stage of Axial Turbine)

  • 김대현;민재홍;정진택
    • 한국유체기계학회 논문집
    • /
    • 제12권1호
    • /
    • pp.22-27
    • /
    • 2009
  • The important problems that arise in the design and performance of the axial flow turbine are the prediction and control of secondary flows. Some progresses have been made on understanding flow conditions that occur when the inlet endwall boundary layer separates at the point in the endwall and rolls up into the horseshoe vortex. And the flows though an axial turbine tend to be extremely complex due to its inherent unsteady and viscous phenomena. The passing wakes generated from the trailing edge of the stator make an interaction with the rotor. Unsteady flow should be considered rotor/stator interactions. The main purpose of this research is control of secondary flow and improvement efficiency in turbine by leading edge modification in unsteady state. When the wake from the stator ran into the modified leading edge of the rotor, the leading edge generated the weak pressure fluctuation by complex passage flows. In conclusion, leading edge modification(bulb2) results in the reduced total pressure loss in the flow field.

PID 제어를 이용한 멀티형 열펌프의 용량조절 (Capacity Modulation of a Multi-Type Heat Pump System Using PID Control)

  • 정대성;김민성;김민수;이원용
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.446-475
    • /
    • 2000
  • Performance of a water-to-water multi-type heat pump system using R22 has been experimentally investigated. Total refrigerant flow rate was adjusted with a variable speed compressor and the refrigerant flow rate for two indoor units were controlled by electronic expansion valves. Evaporator outlet pressure of refrigerant and indoor unit outlet temperatures of secondary fluid were selected as controlled variables. Experiments were carried out for both cooling and heating modes using PID control method. Results show that the multi-type heat pump system can be adequately controlled by keeping control gains at certain levels for various operating conditions.

  • PDF

뉴로퍼지를 이용한 자율운송시스템의 차량합류제어 (Neuro-Fuzzy control of converging vehicles for automated transportation systems)

  • 류세희;박장현
    • 제어로봇시스템학회논문지
    • /
    • 제5권8호
    • /
    • pp.907-913
    • /
    • 1999
  • For an automated transportation system like PRT(Personal Rapid Transit) system or IVHS, an efficient vehicle-merging algorithm is required for smooth operation of the network. For management of merging, collision avoidance between vehicles, ride comfort, and the effect on traffic should be considered. This paper proposes an unmanned vehicle-merging algorithm that consists of two procedures. First, a longitudinal control algorithm is designed to keep a safe headway between vehicles in a single lane. Secondly, 'vacant slot and ghost vehicle' concept is introduced and a decision algorithm is designed to determine the sequence of vehicles entering a converging section considering energy consumption, ride comfort, and total traffic flow. The sequencing algorithm is based on fuzzy rules and the membership functions are determined first by an intuitive method and then trained by a learning method using a neural network. The vehicle-merging algorithm is shown to be effective through simulations based on a PRT model.