• Title/Summary/Keyword: Total Floor Area

Search Result 247, Processing Time 0.024 seconds

The Secondary Vegeation and Sucession of the Forest Fire Area of Nae-Hak Dong, Mt. Palgong (팔공산 내학동일대의 산화적지의 이차식생과 천이)

  • Cho, Young Ho
    • The Korean Journal of Ecology
    • /
    • v.6 no.1
    • /
    • pp.22-32
    • /
    • 1983
  • The paper is investigation of the secondary vegeation and succession at the forest fire area in Mt. Palgong. The survey was carried out from April, 1981 to Stempter, 1982. The floristic compositions were as follows: 50 families, 116 genera, 127 species, 15 varieties and 3 formae(145 kinds). Among them, the floristic composition of the pine floor vegetation of the unburned area was 43 families, 80 genera, 88 species, 10 varieties and 1 forma(99 kinds), and that of the secondary vegetatiion after forest fire was 46 families, 106 genera, 120 species, 14 varieties and 3 formae(137 kinds). Index of similarity between the burned and unburned area was 0.77. The biological type succeeded in $H-D_1-R_5$type, and the erect form(s) was prevailed. Carex humilis var. nana, Miscanthus sinensis var. purpurascens, and lespedeza cyrtobotrya were dominant species in the $ B_1; and; B_2$ area of the seventh year after forest fire. In the degree of succession, species diversity, and evenness index, DS, H, and e of the $B_1$ area were higher than those of the $B_2$ area. In the soil properties, it assumed that pH, total nitrogen, and available phosphores of the burned area were nearly recovered to those of the unburned area.

  • PDF

A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance (염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구)

  • Oh, Myung-Hwan;Sim, Se-Ra;Lee, Chul-Sung;Chin, Kyung-Il;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

Energy Expenditure in Normal-Weight and Overweight Korean Middle-Aged Women

  • Kim, Wha-Young;Cha, Jin-Young
    • Nutritional Sciences
    • /
    • v.4 no.1
    • /
    • pp.34-38
    • /
    • 2001
  • The purpose of this study was to compare the energy expenditure of normal-weight and overweight Korean middle-aged women (40-60 yr). Middle-aged oveweight ($BMI\;{\geq}\;25$, n= 20) and normal-weight women were ($BMI\;{\leq}\;23$, n = 20) were recruited in Seoul. Anthropometric measurements, body composition, energy intake, daily activity time, and energy costs of some daily activities were measured. Energy expenditure at rest and while reading the newspaper, washing dishes, mopping the floor, and walking on a treadmill at 1.0, 2.0, 3.5mph were measured by indirect calorimeter and total daily energy expenditure was estimated by summation of energy costs of different activities. The overweight group had significantly higher values of body weight, triceps skinfold thickness, thigh circumference, waist circumference, hip circumference, BMI, WTR, WHR, body surface area, percentage body fat, fat mass, fat free mass (FFM), and muscle mass compared to normal-weight group. The energy intakes of both groups were close to RDA and other nutrient intake status was also satisfactory. There were no significant differences in intakes of energy and nutrients between the two groups. Overweight subjects showed lower energy expenditure per kg body weight for reading the newspaper, washing dishes and mopping the floor, and walking on a treadmill at 2.0 and 3.5 mph, however, energy expenditure per kg FFM did not differ between the two groups. Daily energy expenditure for all activities was significantly higher in the overweight compared to the normal-weight group due to higher body weight. Both overweight and normal-weight groups showed negative energy balance between energy intake and energy expenditure, and there was no significant difference in energy balance between the two roups. Total daily energy expenditure correlated highly with FFM and body surface area. The result of present study does not offer an explanation on the energy imbalance and weight gain of overweight women.

  • PDF

Disinfection State and Effective Factors of Foodservice Facilities and Utilities of Elementary Schools in Busan -Based on the Characteristics of Dietitian, Employee and Foodservice- (부산지역 초등학교 급식시설,설비의 소독실태 및 영향요인 -영양사, 조리종사원 및 급식소 특성에 따른-)

  • Kim, Ji-Hyeon;Kim, Lee-Seon;Han, Ji-Suk
    • Journal of the Korean Dietetic Association
    • /
    • v.10 no.1
    • /
    • pp.34-46
    • /
    • 2004
  • The purpose of this study was to investigate disinfection state and effective factors of foodservice facilities and utilities of elementary schools in Busan area. Foodservice facilities and utilities investigated in this study were ceiling, wall, floor, trench, greasetrap, hood, pest and dumb waiter. The questionnaire which was administered to 196 dietitians was used as a survey method. The results were as follows. The washing method of foodservice facilities and utilities was mainly used by detergent washing-natural dry. The disinfection method of foodservice facilities and utilities was mainly sanitized by sodium hypochlorite. Dumb waiter and hood were sanitized by 70% ethyl alcohol and iodine. In washing and disinfection frequencies of foodservice facilities and utilities ceiling was twice/year, wall, hood and pest control facilities were once/week, floor, trench, greasetrap and dumb waiter were everyday, respectively. Floor, trench, greasetrap and dumb waiter were disinfected properly, whereas ceiling, wall, hood and pest were not disinfected properly. The washing method was related to dietitian's marital status and education. The disinfection state was related to dietitian's age and career, having of sanitation check list. The disinfection method was also affected dietitian's marital status, number of employee, duration of foodservice, number of total serving and having of sanitation check list. Therefore based on the results of this study, it should be given to the microbiological study on disinfection of facilities and utilities such as ceiling, wall, floor, trench, greasetrap, hood, pest and dumb waiter and the dietitian and employee's sanitation training also should be conducted continuously.

  • PDF

Estimation Method of the Amount of Demolition Waste through Automated Calculation of Volumetric Spaces using Drones (드론 활용 체적산출 자동화를 통한 해체 폐기물량 예측기법에 관한 연구)

  • Ryu, Jung-Rim;Kim, Hye-Ri;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.681-688
    • /
    • 2022
  • In this study, the process of drone photography, automatic volume calculation, total floor area conversion, and waste calculation was constructed as a QGIS plug-in to predict the demolition waste (DW) generated in an aged area where drawing information or building information is uncertain. Through a case study, the high consistency between the automatically calculated volume using the drone and the BIM volume based on the field measurement was confirmed. Field application was carried out for the planned demolition work site, and the consistency between the drone-based volume and the actual measurement-BIM-based volume was reconfirmed. The waste generation unit was applied and the amount of DW was calculated by setting the floor height and building type, and the entire process was completed within 6 hours. Although the difference between building information and building objects through drones occurred according to the setting of temporary structures, loads, and floor heights, it was found that the actual amount of DW was generated more than the initial estimate. It is expected that measures to improve the accuracy of volume and floor area conversion will be required through case studies in the future.

A Study on the Maintenance Cost Estimation Model of the Apartment Housing (공동주택의 관리비 추정모델 연구)

  • Lee, Kang-Hee;Yang, Jae-Hyuk;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.59-67
    • /
    • 2010
  • The maintenance cost plays a important role to plan the scale of the apartment housing such as a number of household, building area and building type. Therefore, it is required to forecast the cost considering various maintenance characteristics. The maintenance characteristics are floor area, number of household, heating type, site area and etc.. In addition, the maintenance cost are classified into 5 area. These are a personal expense, facility maintenance cost, energy and water cost, insurance and sanitary cost. These five cost area are related with various characteristics and brought up the estimation model using the stepwise multiple regression analysis. The energy and heating cost share over the 50% in the total cost and the personal expense cost shares about 40%. The personal expense cost per area is 5,272 won/$m^2{\cdot}yr$ irregardless of heating type and the district heating type is a higher cost than other type. In facility maintenance cost, the central heating type is 2,015 won/$m^2{\cdot}yr$ and higher than other type. The estimation models have good statistics in each model. Most of the model have a determination coefficient over 0.7 and Durbin Watson value between 1.5 and 2.5.

Prediction of Demand for Photovoltaic Power Plants for Electric Vehicle Operation (전기자동차 운행을 위한 태양광발전소 수요 예측)

  • Choi, Hoi-Kyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.4
    • /
    • pp.35-44
    • /
    • 2020
  • Currently, various policies regarding ecofriendly vehicles are being proposed to reduce carbon emissions. In this study, the required areas for charging electric vehicle (EV) batteries using electricity produced by photovoltaic (PV) power plants were estimated. First, approximately 2.4 million battery EVs, which represented 10% of the total number of vehicles, consume approximately 404 GWh. Second, the power required for charging batteries is approximately 0.3 GW, and the site area of the PV power plant is 4.62 ㎢, which accounts for 0.005% of the national territory. Third, from the available sites of buildings based on the region, Jeju alone consumes approximately 0.2%, while the rest of the region requires approximately 0.1%. Fourth, Seoul, which has the smallest available area of mountains and farmlands, utilizes 0.34% of the site for PV power plants, while the other parts of the region use less than 0.1%. The results of this study confirmed that the area of the PV power plant site for producing battery-charging power generated through the supply of EVs is very small. Therefore, it is desirable to analyze and implement more specific plans, such as efficient land use, forest damage minimization, and safe maintenance, to expand renewable energy, including PV power.

A Comparison Analysis on the Facility Standards and Campus Sizes of the National Universities in Korea and Japan (한·일 국립대학 시설 기준 및 캠퍼스 면적 비교·분석)

  • Choi, Hyeong Ju
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.3
    • /
    • pp.1-15
    • /
    • 2019
  • This study analyzes universities in Japan, which haves many similarities with those in Korea in certain aspects of the educational system and a common problem of reduced university admission resources, Korea's national university facility standards, policy related to nation-level university facility, and practical campus case. Through this, the study aims to examine the difference in the national approach and basic philosophy about university facilities in Korea and Japan, and also identify the major planning factors and improvement directions when establishing plans for university campuses in the future. The results of this study are as follows. First, Korea tends to promote policies related to university facilities by individual projects centered on a major pending problem or issue, while Japan has been shown to promote national university facility policies under a comprehensive mid-to-long-term plan by establishing a maintenance plan aimed at national university facilities every five years. Second, In the case of the university facility areas, the average university facility area of the examined universities in Japan is about 5.6% larger than the average university facility area in Korea. Additionally, the university facility area per student in Japan is about 13% wider than that of Korea. The total floor area of university facilities in Japan is also about 20.7% larger than that of Korea, and the university facility area per student in Japan is about 56.7% wider than that of Korea as well. Among support facilities, the total floor area of dormitories in Korea was 2.5 times wider than that of Japan, however, the acceptance rate of dormitory in Korea was 5.6% higher than Japan. Third, the university facility criteria items and systems of two countries are similar. but there are slight differences in the content such as the method of calculating student capacity, division classification, and the method of calculating the number of teachers.

Analysis of Land Use Characteristics Using GIS DB - A Case Study of Busan Metropolitan City in Korea - (GIS DB를 이용한 토지이용 특성 분석 - 부산광역시 건물 높이 시뮬레이션을 중심으로 -)

  • Min-Kyoung CHUN;Tae-Kyung BAEK
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.3
    • /
    • pp.52-64
    • /
    • 2023
  • As cities continue to develop rapidly, overcrowding, pollution, and urban sanitation problems arise, and the need to separate conflicting uses is emerging. From this perspective, there is no disagreement that urban land use should be planned. Therefore, all activities in land space must be predicted in advance and planned so that land use can be rationally established. This study used the constructed data to compare and analyze the use distribution characteristics of residential, commercial, and industrial areas in Busan Metropolitan City to identify the building area status, total floor area, and floor area ratio by use zone in districts and counties in Busan Metropolitan City. As a result, it was found that the residential area accounted for the largest proportion of the area by use zone at 51%, and that the residential area accounted for the largest proportion at 63% of the total floor area by use zone. And the analysis was conducted using a specialization coefficient that can identify regional characteristics based on land use composition ratio. Because it is difficult to determine the trend of the entire region just by counting the absolute value of the area, the area composition ratio was calculated and compared. Looking at the residential facilities among the specialization coefficients by use area, it is above 1.0 except for Gijang-gun, Sasang-gu, Saha-gu, and Jung-gu. Commercial facilities are over 1.0 except for Gijang-gun, Gangseo-gu, Nam-gu, Sasang-gu, and Saha-gu. Looking at industrial facilities, you can see that the industrial complex distribution area is Gangseo-gu (2.5), Gijang-gun (1.22), Sasang-gu (2.06), and Saha-gu (1.64). In addition, it was found that business facilities and educational welfare facilities were evenly distributed. Land use analysis was conducted through simulation of the current status of building heights according to each elevation in each use area and the height of buildings in each use area. In general, areas over 80m account for more than 43% of Busan City, showing that the distribution of use areas is designated in areas with high altitude due to the influence of topographical conditions.

Study on the Utilization of Sawdust Bedding Barn for Dairy Cows II. Comparision of utilization efficiency of the different depth of sawdust bedding for dairy cows (착유우의 톱밥발효우사 이용 연구 제2보 :착유우 톱밥발효우사의 톱밥상 처리방법에 따른 이용효과 비교)

  • 권두중;권응기;정석근;한정대;정석찬;강승원;강상열;정형섭;장학주
    • Journal of Animal Environmental Science
    • /
    • v.1 no.2
    • /
    • pp.117-124
    • /
    • 1995
  • This study was carried out to investigate the effect of depth of sawdust bedding and ground material in dairy cattle barn. Treatment included the concrete floor with a 10cm or 30cm sawdust and the earth floor with a 30cm sawdust. Eighteen cows were assigned to 3 pens with 16.5㎥/head bedding area. The results obtained were as follows : 1. The temperature of sawdust bed was highest in the earth floor with 30cm sawdust, and the moisture content of sawdust bed was highest in the concrete floor with 10cm sawdust bed. 2. Cows defecate feces 9.2, 8.7 and 9.3 times a day in 10cm sawdust on concrete floor(10S+C), 30cm sawdust on concrete floor(30S+C) and 30cm sawdust on non concrete floor(30S+ NC) respectively. In average, they excreta 9.1 times/day(85.8%) in the sawdust beds and 1.5 times/day(14.2%) in the feeding alley. 3. The ratio of daily water amount deposited vapor to total water amount deposited in sawdust beds was 74.0%, 61.5% and 47.1% in 10S+C, 30S+C and 30S+NC respectively. 4. N.P.K contents in the sawdust beds were higher for 10S+C compared with other treatments. 5. When 30cm of sawdust was applied on the earth ground NO$_3$-N contents in the sawdust bed was 37.7, 14.1 and 15.0ppm in depth of 30, 60 and 90cm under the ground, respectively, indicating some possibility of water pollution.

  • PDF