• Title/Summary/Keyword: Total Floor Area

Search Result 246, Processing Time 0.029 seconds

Investigation of Microbial Contamination and Working Environment in University Foodservices (대학급식소 작업시설과 환경의 미생물 오염도 분석 및 작업환경 실태조사)

  • Park, Soon-Hee;Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.23 no.2
    • /
    • pp.180-191
    • /
    • 2017
  • The purpose of this study was to identity the probability of cross-contamination from the environment. For this, we examined foodservices at 20 universities/colleges for microbiological analysis of their working facilities and environment as well as their preventive equipment against cross-contamination. Seventy percent of the 20 foodservices were found to maintain one unified working area, which suggests high probability of contamination of food/utensils/equipment in the cooking area by pre-preparation or dish washing. According to the microbiological analysis, the hygiene acceptance ratio of working facilities in the clean zone was 70%, which was higher than the average 45% hygiene acceptance ratio of working facilities in the contamination operating zone. There was a significant difference in the total plate count (P<0.001) and coliform count (P<0.01), which demonstrates that work tables in the clean zone were in a good state compared to those in the contamination operating zone. In the contamination operating zone, refrigerator shelves had a high probability of cross-contamination. Regarding the floor surface and airborne microbes, cooking areas which should be maintained as clean zones had higher cross-contamination probability than those in the contamination operating zone. So corrective actions such as cleaning and sanitizing, keeping dry floors, lowered temperature and humidity, shoe disinfecting facilities, and checking concentrations, are necessary to manage floor surfaces and airborne microbes in the cooking area.

Analyzing the Change of Indoor Thermal Environment with the Introduction of the Water Space in Exterior Housing (주거 외부 수공간 도입에 따른 실내 온열 환경 변화 분석)

  • Oh, Sang-Mok;Oh, Se-Gyu;Won, Hyun-Seong
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.41-48
    • /
    • 2010
  • This study shows how the water space outside the housing impacts the indoor thermal environment. CFD simulation was used for this experiment to analyze the interior environment focusing on the effect of temperature control and the thermal comfort. A shape of perfect square, which creates the very basic space formation, was used and the simulation was processed looking at the size, distance, and the location of the water space. The results of the experiment are as follows. Firstly, introducing a water space with the same floor area size of the simulation model decreased the indoor temperature by 1 Celsius (3.72%). It was determined the interior environment was considered as a comfort zone when the water space was greater than 70% of the floor area. Secondly, there was not much influence to the level of thermal comfort of the interior environment when the distance to the water space from the housing was greater than 2 meters. Lastly, interpreting the location of water space, the effect of controlling the total areas' temperature was the greatest following with the surrounding of the formation. There barely was any change to the temperature considering the side and the rear of the area.

A study on the suitable of building size in district units plan (지구단위계획(地區單位計劃)에서 건축(建築) 규모설정(規模設定)에 관한 연구(硏究))

  • Lee, Won-Geun;Lee, Jae-Kook;Do, Gyu-Hwan
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.1
    • /
    • pp.39-49
    • /
    • 2003
  • The height provisions, by the urban planning, describe the hightest height per width division, also define oblique line limitation by road without mentioning the highest per width division. Therefore this study will be a basic model for the standard of measuring the highest height per width division analysizing the propriety of current standard of oblique limitation. This technique is prepared to prevent the confusion and to complements the existing planning method. Therefore, it takes more time to establish this new method and to apply it to the existing condition. This study reviewed density control in District Units Plan, based on the guidelines of density, which included height, ratio of total floor to ground area, and land distribution. This study aims to provide efficient analysis by using current oblique limitation provisions Thus, proving the area rations of general residential areas are decreasing. Since the purpose of the District Units Plan is to avoid confusion and help ease the existing problematic conditions which have risen from the two above-mentioned conventional systems, further observation and research on these areas are necessary.

  • PDF

The Regressive Causal Structure of Heating Energy Consumption Affected by Household Income and Housing Characteristics (소득수준과 주택특성에 따른 난방에너지 소비의 역진적 인과구조)

  • Choi, Mack Joong;Chung, I Re
    • Journal of Korea Planning Association
    • /
    • v.53 no.6
    • /
    • pp.101-116
    • /
    • 2018
  • Paying an attention to the issue of energy poverty of low-income households and ensuing regressivity of energy consumption, this study empirically analyzes the effects of both household and housing characteristics on heating energy consumption in an integrated way and identifies their causal structure based on the 2016 Korea Housing Survey data provided by the Korean government. Multiple regression analysis shows that household income and deteriorated level of housing, such as age and degree of cracks have positive effects and floor area of housing has a negative effect on the heating energy consumption per unit area of housing (HECPUH). Path analyses further reveal that the direct effect of household income on HECPUH is offset by the indirect effects that are mediated by deteriorated level and floor area of housing, making the total effect statistically insignificant. As a result, there is no significant difference in HECPUH across all income strata, implying that low-income (high-income) households pay more (less) heating costs relative to their income level, since they reside in the houses with relatively low (high) energy efficiency. To deal with this regressive causal structure of energy consumption, a policy option is recommended to improve energy efficiency of low-income housing through the government assistance in its maintenance and repair.

A Study on the Actual Conditions of the Utilization of Closed Schools in Gyeongnam Area (경남지역 폐교의 활용실태에 관한 연구)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.53-60
    • /
    • 2018
  • The purpose of this study is to present the basic data for the active use of closed schools by analyzing the actual conditions of closed schools in Gyeongnam area. As a method of this study, we examined the population change in Gyeongnam area through the literature survey and the internet site survey, and grasped the characteristics of the policies related to the closed school. Through the homepage survey of the local education financial alerts, we analyzed the contents, location, period after the closure, land area, and total floor area of the closed schools that have been in use or invaluable as of March 2017. As the results, In the case of self-utilization, the utilization rate of educational facilities was overwhelmingly high. In the case of lease utilization, the utilization ratio was higher in the order of education facilities, income increase facilities, and cultural facilities. Overall, 62.8% of the closed schools are located in the base towns (urban areas). The average of the period after the closure was 16.2 years, the land area average was $9,291.1m^2$, and the total area average was $1,153.8m^2$.

A Study on the Areal Analysis of the Sports Center for the Disabled User (장애인의 이용을 고려한 스포츠시설의 면적현황 분석에 관한 연구)

  • Seong, Ki-Chang;Chai, Choul-Gyun;Kang, Tae-Sung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.14 no.4
    • /
    • pp.31-38
    • /
    • 2008
  • As people's interest in the increase of individual leisure time and health grows, their interest in sports is also growing day by day to improve their standards of living. In the midst of the social changes, people's awareness of the disabled's sports activities is changing as well. However, the disabled's full access to public sports centers is restricted due to the shortage of facilities, area and available programs in public sports centers including community gymnasiums. In order to solve this problem, rehabilitation sports centers have been built as part of public sports centers, but the number of rehabilitation sports centers is still small. Besides, the disabled find themselves uncomfortable when using rehabilitation sports centers because most of them are outdated and too small in size. To make matters worse, sports centers for the use of the disabled only have a negative effect on the disabled's making inroads into society by hampering them from being a part of social unification. This study made a comparative analysis on the areal state of indoor gyms and swimming pools, which are the main areal factors of rehabilitation sports centers and public sports centers. Based on this analysis, this study aims to propose a sports center use plan for both the disabled and non-disabled. As a result, the total floor area ratios of indoor gyms for the disabled were found to be higher than those of public sports centers. This is because many indoor gyms for the disabled are not well equipped with resting areas, auxiliary or supporting areas. Regarding swimming pools for the disabled, their total floor area ratios and areas were found to be lower than those of public sports centers because, in many cases, these swimming pools are used for the rehabilitation of the disabled in rehabilitation sports centers. For this reason, swimming area for individual leisure activity or hobby is insufficient.

  • PDF

A Study on the Location and Space Composition of Small Elderly Care Facilities - Focus on the Elderly Care Facilities in Gyeongsangnam-do - (소규모 노인요양시설의 입지 및 공간구성의 실태 고찰 - 경남지역 노인요양시설을 중심으로 -)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.25 no.3
    • /
    • pp.17-25
    • /
    • 2023
  • The purpose of this study is to analyze the location and space composition of small elderly care facilities in gyeongsangnam-do and to present a desirable direction for planning small elderly care facilities. As a research method, the location and spatial composition of 82 facilities for elderly care facilities with a capacity of 10 to 29 installed in Gyeongsangnam-do were investigated. In particular, the location, site area, total floor area, and composition of major rooms of small elderly care facilities were analyzed. The results of the survey and analysis are as follows. First, as for location characteristics, 56.1% of the suburban and rural types, 28.1% of the urban area type, and 12.2% of the mountain type were found in order. Second, in the connection between location and spatial composition, stand-alone facilities accounted for 53.7%, and complex types accounted for 46.3%. Third, the average number of admissions was 23.1, and facilities corresponding to the size of 26-29 admissions were the largest at 41.0%. The total floor area per person was 28.3m2. Fourth, in terms of the spatial composition of facilities, stand-alone facilities accounted for 53.7%, and complex types accounted for 46.3%. Fifth, by the number of people in the bedroom, 49.4% were installed in the order of a four-person room, 25.0% in a three-person room, 18.7% in a two-person room, and 3.5% in a one-person room. In addition, in the bedroom lifestyle, 84.1% of the bed type and 15.9% of the bed + sitting type were found.

A Proposal for expansion of the low-floor bus based on analysis of living area for the handicapped mobility people in Seoul Using R (R을이용한 서울시 교통약자 생활권 분석에 따른 저상버스 확대 제안)

  • Yun, Sang-hee;Kim, Jeong-joon;Jeon, Gwang-il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.195-201
    • /
    • 2017
  • As of 2016, the total traffic usage of handicapped people were 24.8%. Buses (25.6%) have the highest rate of travel, with the exception of "walking (33.5%)" as the main means of transportation for these handicapped people. Therefore, the Seoul Metropolitan Government expanded the low-floor bus, which is a means of transportation for the underbelly, to 30% by 2015, but the satisfaction level of mobility improvement of the underbelly was only 2% To 55%. In fact, increasing the percentage of low-floor buses is merely a superficial solution, and there are many restrictions on solving fundamental problems with limited budgets. Therefore, in this study, we use statistical analysis R, with a simple data manipulation and visualization function, to grasp the living area and life pattern of handicapped people in Seoul city.

Evaluation of adenosine triphosphate testing for on-farm cleanliness monitoring compared to microbiological testing in an empty pig farrowing unit

  • Yi, Seung-Won;Cho, Ara;Kim, Eunju;Oh, Sang-Ik;Roh, Jae Hee;Jung, Young-Hun;Choe, Changyong;Yoo, Jae Gyu;Do, Yoon Jung
    • Journal of Animal Science and Technology
    • /
    • v.62 no.5
    • /
    • pp.682-691
    • /
    • 2020
  • Careful cleaning and disinfection of pigpens is essential to prevent disease spread and avoid the resultant economic losses. Hygiene in pigpens is generally evaluated by visual monitoring supplemented with bacteriological monitoring, which includes counting the total aerobic bacteria (TAB) and/or fecal indicator bacteria (FIB). However, these methods present drawbacks such as time and labor requirements. As adenosine triphosphate (ATP) is ubiquitous in all living organisms including microorganisms, this study aimed to directly compare the results of microbial assessment and ATP quantification, and to suggest possible detailed application methods of the ATP test for hygiene evaluation in pigpens of a farrowing unit. Before and after standard cleaning procedures, samples were collected from the floor corner, floor center, and feeding trough of four pigpens at different time points. No FIB were detected and both the TAB and ATP levels were significantly decreased in the floor center area after cleaning. FIB were continuously detected after cleaning and disinfection of the floor corners, and there was no significant ATP level reduction. The feeding trough did not show any significant difference in these values before and after cleaning, indicating insufficient cleaning of this area. The levels of TAB and ATP after cleaning were significantly correlated and the average ATP value was significantly lower in the absence of FIB than in their presence. In the absence of standard references, a more thorough hygiene management could be achieved evenly by supplementing cleaning or disinfection based on the lowest ATP results obtained at the cleanest test site, which in the present study was the floor center. Overall, these results indicate that the on-farm ATP test can be used to determine the cleanliness status, in addition to visual inspection, as an alternative to laboratory culture-based testing for the presence of microorganisms.

A Study on the Architectural Planning Characteristics of Medical Buildings - Focused on Cheong-ju Area (메디컬빌딩의 건축계획특성 연구 - 청주지역을 중심으로)

  • Baek, Sang Yeol;Kim, Gi Soo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.3
    • /
    • pp.69-77
    • /
    • 2015
  • Purpose: Under a trend of hospitals that repeated expansion in line with fast increasing factors of medical demands in the past, medical buildings where clinic businesses have regularly gathered in one building have exponentially increased since separation of prescribing and dispensing in 2000. Thus, this study aims at analyzing characteristics of architectural plan of the current medical buildings, identifying strengths and weaknesses through Post Occupancy Evaluation and suggesting an architectural planning method of medical buildings to be planned in the future. Methods: Scope of study has been limited to 23 medical buildings that are registered in the building register as medical buildings out of the Class 1 neighborhood facilities build as 5 floors or more in Cheongju region since 2000 and being actually used for the usage. Study method is to define concepts of the medical buildings through literature review and advanced researches, analyze characteristics of architectural plan through drawing analysis and site survey. Results: General characteristics of architectural plans for the medical buildings in Cheongju have been analyzed. There are the most frequencies in general commercial area and semi-residential area, most of them are reinforced concrete structure and the Class 1 neighborhood facilities. Average land area is $482.68m^2$, gross floor area $3720.8m^2$, the number of underground floors level 1.16, the number of floors level 7.76, total number of floors 8.92, the building-to-land ratio 67.28%, floor area ratio 452.6%, height 31.44m, and the number of parked vehicles 24.16. Implications: This research will contribute to the establishment of the planning methods which increase the quality of Medical Buildings in Cheongju.