• 제목/요약/키워드: Total Energy Usage

검색결과 135건 처리시간 0.022초

마곡지구 하수열에너지이용 타당성 검토 (Feasibility study on district heating Magok area by sewage water heat source)

  • 이영수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.357-362
    • /
    • 2009
  • As a unutilized energy, treated sewage water locates widespread near urban areas. From the previous survey, the sewage water is reported to hold energy potential up to 36,000 Tcal/year, which was 2.1% of the total domestic energy consumption and 9.7% of the energy usage in the household and business sector in 2006. Temperature of the sewage water differs locally, but its range is observed in a range of $20{\sim}25^{\circ}C$ in summer and $8{\sim}13^{\circ}C$ in winter. Since the temperature range of the sewage water has a better seasonal distribution about $5{\sim}10^{\circ}C$ compared to ambient air, it is a promising heat sink for summer or heat source for winter. The sewage water is also a high quality heat source from its abundant quantity and uniform temperature. Considering the ambient temperature of Korea is very low in winter, a heat pump system using the sewage water can be an alternative to prevent problems of capacity deficiency and frost formation.

  • PDF

서브미터링 전력데이터 기반 건물에너지모델의 입력수준별 전력수요 예측 성능분석 (Performance Analysis of Electricity Demand Forecasting by Detail Level of Building Energy Models Based on the Measured Submetering Electricity Data)

  • 신상용;서동현
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.627-640
    • /
    • 2018
  • Submetering electricity consumption data enables more detail input of end use components, such as lighting, plug, HVAC, and occupancy in building energy modeling. However, such an modeling efforts and results are rarely tried and published in terms of the estimation accuracy of electricity demand. In this research, actual submetering data obtained from a university building is analyzed and provided for building energy modeling practice. As alternative modeling cases, conventional modeling method (Case-1), using reference schedule per building usage, and main metering data based modeling method (Case-2) are established. Detail efforts are added to derive prototypical schedules from the metered data by introducing variability index. The simulation results revealed that Case-1 showed the largest error as we can expect. And Case-2 showed comparative error relative to Case-3 in terms of total electricity estimation. But Case-2 showed about two times larger error in CV (RMSE) in lighting energy demand due to lack of End Use consumption information.

고온 생산용 열펌프 사이클 설계 (Study on Design Technology of Heat Pump Cycle for High Temperature Performance)

  • 김종률;김석영;김용민;이공훈;김욱중;이성철;정치영;김종열
    • 에너지공학
    • /
    • 제19권4호
    • /
    • pp.228-233
    • /
    • 2010
  • 기존의 열풍건조기의 효율은 약 30% ~ 50%인 반면, 최적 설계된 열풍-열펌프 건조기 효율은 약 60% ~ 80% 수준이므로 에너지 효율향상과 에너지 절약을 이룰 수 있다. 외국의 여러 사례에서는 기존 대비 약 60% ~ 80%의 에너지를 절약할 수 있으며, 밀폐형 순환방법을 사용하여 건조공기에 포함될 수 있는 환경오염물질의 외부로의 유출을 최소화 할 수 있어 기존의 건조기에 비해서 환경문제에 적극적으로 대응할 수 있을 것을 판단된다. 본 논문에서는 이와 같은 특성을 가진 건조기에 적용하기 위한 고온 생산이 가능한 열펌프를 얻기 위하여 시스템의 사이클을 설계하고 시스템을 구축하여 목표 성능을 만족하는지 여부를 확인하였다. 본 연구에서는 열펌프 복합건조기 적용을 위한 고온용 열펌프 시스템을 설계하고 제작한 후, 성능평가를 수행하여 다음의 결론을 얻었다. (1) 고온생산을 위한 시스템 설계는 2사이클이 가장 우수한 것으로 나타났다. (2) 2사이클 시스템은 저단이 R134a를, 고단이 R124를 냉매로 사용할 경우 가장 적합한 것으로 나타났다. (3) 사이클 운전을 통하여 상용압력으로 간주되는 범위에서 R134a시스템은 $75^{\circ}C$, R124시스템은 $95^{\circ}C$ 생산이 가능한 것으로 나타났다. (4) 수냉식 2사이클 시스템의 성능 시험을 수행한 결과 목표성능을 상회하는 결과를 얻어 고온 생산이 가능한 열펌프 시스템의 설계 및 제작이 가능한 것으로 나타났다.

Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • 제19권4호
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.

염색폐수 처리공정의 온실가스 배출량 산정 및 환경성 평가 (Estimation of Greenhouse Gas Emissions and Environmental Assessment of Dye Wastewater Treatment Process)

  • 신춘환;박도현
    • 한국환경과학회지
    • /
    • 제23권11호
    • /
    • pp.1881-1888
    • /
    • 2014
  • Greenhouse gas (GHG) emissions from dye wastewater treatment processes were estimated by analysing their mass and energy balances, which were then used as baseline information for environmental assessment. The total GHG emissions from dye wastewater treatment plants were divided into direct emissions from the treatment processes and indirect ones from electricity usage. The amounts of $CO_2$, $CH_4$ and $N_2O$ emissions were calculated according to the Intergovernmental Panel on Clime Change (IPCC) guideline for the GHG target management system. For 3 years between 2011 and 2013, direct and indirect emissions were on average 8,742.7 and 7,892.0 Ton.$CO_2eq/year$, respectively, with the former exhibiting 52.6 %. Also, compared to 2012, in 2013, the eco-efficiency indicator by the GHG emissions was found to be more than 1, suggesting that environmental quality was effectively improved.

대학 내 에너지 소비에 따른 온실가스-대기오염 통합 인벤토리 및 대체 에너지 사용 시나리오 분석 (A Study of GHG-AP Integrated Inventories and Alternative Energy Use Scenario of Energy Consumption in the University)

  • 정재형;권오열
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1643-1654
    • /
    • 2014
  • The university is one of the main energy consumption facilities and thereby releases a large amount of greenhouse gas (GHG). Accordingly, efforts for reducing energy consumption and GHG have been established in many local as well as international universities. However, it has been limited to energy consumption and GHG, and has not included air pollution (AP). Therefore, we estimated GHG and AP integrated emissions from the energy consumed by Seoul National University of Science and Technology during the years between 2010 and 2012. In addition, the effect of alternative energy use scenario was analysed. We estimated GHG using IPCC guideline and Guidelines for Local Government Greenhouse Inventories, and AP using APEMEP/EEA Emission Inventory Guidebook 2013 and Air Pollutants Calculation Manual. The estimated annual average GHG emission was $11,420tonCO_{2eq}$, of which 27% was direct emissions from fuel combustion sectors, including stationary and mobile source, and the remaining 73% was indirect emissions from purchased electricity and purchased water supply. The estimated annual average AP emission was 7,757 kgAP, of which the total amount was from direct emissions only. The annual GHG emissions from city gas and purchased electricity usage per unit area ($m^2$) of the university buildings were estimated as $15.4kgCO_{2eq}/m^2$ and $42.4tonCO_{2eq}/m^2$ and those per person enrolled in the university were $210kgCO_{2eq}$/capita and $577kgCO_{2eq}$/capita. Alternative energy use scenarios revealed that the use of all alternative energy sources including solar energy, electric car and rain water reuse applicable to the university could reduce as much as 9.4% of the annual GHG and 34% of AP integrated emissions, saving approximately 400 million won per year, corresponding to 14% of the university energy budget.

Interrelations between Greenhouse Gas (GHG) Emission and Total Floor Area of Buildings -With the Case Study of Public Facilities in Ontario, Canada-

  • Son, Juntae;Chang, Seongju
    • Architectural research
    • /
    • 제19권4호
    • /
    • pp.95-99
    • /
    • 2017
  • Recently, it is becoming increasingly difficult to ignore carbon emission implication of building operations due to the significant rate of energy usage in buildings. In the building sector, our normal expectation implies that large building floor area induces more greenhouse gas (GHG) emission. In this research, the correlation between building total floor areas and GHG emission was explored by simple linear regression and analyzing the yielded residuals for confirming this seemingly obvious conjecture. By looking at the generated regression lines drawn based on the data sets representing public facilities in Ontario, Canada, we were able to confirm that carbon emission rate shows a proportional increase or decrease depending on the total floor area of buildings as has been implied as a conjecture. Some buildings were found to emit significantly large and small amount of GHG, and we addressed potential reasons why those buildings show the deviation from the confirmed proportional interrelation between a building's total floor area and the amount of GHG emission.

산업용 고효율 태양열집열기 개발 필요성 (Status of High-Efficiency Solar Collector for Industrial Utilization)

  • 곽희열
    • 태양에너지
    • /
    • 제18권2호
    • /
    • pp.19-29
    • /
    • 1998
  • 국내 소비 에너지 사용량의 약 97%를 수입에 의존하고 있고, 지구온난화와 관련된 환경문제가 심각하게 대두되고 있는 실정이다. 또한 우리나라 에너지 부문별 소비형태에서 47%를 차지하는 산업용의 에너지 소비는 대부분 유류애 의존하고 있고, 그 중에서도 제조부분의 소비가 91.5%로 나타나고 있어, 이 부분에 대체어네지원의 개발, 대체 시스템의 적용이 절실히 요구되고 있다. 우리 나라에서도 국가적 에너지 절약과 쾌적한 주거환경 및 생활의 편리함을 위해 기존 화석에너지로부터 무공해 청정에너지(Clean Energy)로 그 사용형태가 바뀌어 가는 지금 그 양과 질적인 면에서 무한정이고 무공해인 대체 에너지원으로서의 태양에너지는 다양한 이용분야가 개발되어 실용화되고 있다. 국�K의 경우 대표적으로 평판형 태양열집열기를 이용한 온수급탕 시스템을 들 수 있고, 냉난방, 산업공정열 및 태양열 발전 분야에 대한 실용화 및 타당성 연구가 활발히 진행되고 있다. 따라서 본 고에서는 태양열 시스템의 중요한 구성요소인 고효율 집열기술에서 산업용 응용($70{\sim}150^{\circ}C$)에 적합한 것으로 기대되는 진공유리관형 태양열집열기, 국내 외 기술개발 동향과 산업공정열의 대체 가능성에 대하여 기술하였다.

  • PDF

기후변화 협약 대응을 위한 산업별 온실가스 배출 특성 분석 (An Analysis of Sectoral GHG Emission Intensity from Energy Use in Korea)

  • 정환삼;동야달;심상렬
    • 기술혁신학회지
    • /
    • 제11권2호
    • /
    • pp.264-286
    • /
    • 2008
  • 2006년 우리나라의 에너지 사용은 총수입액(28%), 해외의존(97%), 온실가스배출(83%-year 2004)의 비중을 차지하고 있어, 경제나 환경 정책에서 매우 중요한 산업분야이다. 그러나 현실적으로 국내 에너지사용에 따른 온실가스 배출 추계는 산업별 사용량에 국제기구가 권고한 계수를 곱해 사용하는 수준에 머물고 있다. 이러한 수준으로는 post Kyoto Protocol을 통한 개도국의 참여를 강제하려는 새로운 패러다임에 대응할 논리와 정책을 바르게 수립할 수 없다. 본 연구는 한국은행이 발간한 2000년 산업연관표를 기반으로 이형단위 산업연관표를 작성하고, 이를 통해 경제 구성 부문별로 에너지 사용에 따른 온실가스 배출 특성을 분석하였다. 분석은 네가지 측면에서 이루어졌으며, 이는 섹터별 온실가스 배출 밀도 추정, 각 그룹에서 온실가스 배출을 야기한 연료원별 기여도 측정, 산업별 배출계수의 산정, 그리고 국가 총배출량 추정이다. 여기서 추정한 배출량은 온실가스 배출에 관한 국가 공식 통계치와 비교 검증하였다. 연구 접근법은 에너지의 직접사용 과정에서 배출되는 온실가스의 양 뿐만 아니라 배출을 유발하는 간접원인까지도 분석하고 있어, 최근 확산되고 있는 전과정분석(Life Cycle Analysis) 개념에 적합한 모형이다. 이 모형은 향후 온실가스 저감 정책 수립의 중요한 기반이 될 것으로 기대한다.

  • PDF

건물 부문의 에너지 관리체계 구축수립 기본 방안에 관한 연구 (A Study on Establishment of the Basic Plan to Construct an Integrated Management System of National Building Energy)

  • 유정현;김종엽;황하진
    • 토지주택연구
    • /
    • 제2권4호
    • /
    • pp.379-385
    • /
    • 2011
  • 국내의 건물부문 에너지 소비량은 전체 소비량의 약 25%를 차지하고 있으며, 생활수준의 향상, 세대수의 증가 등에 기인하여 선진국 수준으로 지속적인 증가추세를 보일 것으로 전문가들은 예측하고 있다. 한편 정부는 2009년부터 녹색뉴딜사업의 일환으로 국토 에너지 수자원 건물 등의 각종 기본정보를 체계적으로 일원화시키고 통합 DB를 구축하는 녹색국가 정보인프라 사업을 추진 중에 있다. 특히 건물과 관련해서는 에너지 절약과 온실가스 저감 대책 마련에 효율적으로 대응하기 위한 수단으로, 건물단위의 에너지 소비량 관리를 기본 골자로 하는 건물 에너지 통합관리시스템 구축을 강구중에 있다. 본 연구에서는 국가 건물에너지 통합관리시스템 구축(이하, 통합관리시스템)에 요구되는 추진계획 및 로드 맵 작성을 목적으로, 기존 에너지 소비량 관련 자료 조사 및 전문가 면담 등의 분석을 통하여 통합관리시스템의 목표와 계획 수립에 따른 단계별 전략과제와 핵심과제를 도출하고자 한다. 나아가, 건물부문의 에너지 및 온실가스 통계 마련과 관리를 위한 통합관리센터의 구축과 운영방안 수립에 활용할 수 있는 방안을 제시하여 향후 녹색뉴딜 사업의 육성을 도모하고자 한다.