• Title/Summary/Keyword: Total Effluent Regulation

Search Result 14, Processing Time 0.024 seconds

Metropolitan Area Development Planning and Environmental Impact Assessment in Korea : With Special Reference to Pusan and Asan-Bay Metropolitan Area Development Planning (광역개발계획과 환경영향평가 : 아산만권 및 부산권 광역개발계획을 중심으로)

  • Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.1
    • /
    • pp.47-57
    • /
    • 1995
  • This study analyzes the problems of environmental laws, development planning laws, Metropolitan Area Development Planning(MADP), and the level of environmental pollution at Pusan and Asan-Bay Metropolitan Area where MADP will be realized in the near future. In order to prevent the environmental pollution by realization of MADP, Environmental Impact Assessment Act and environmental impact assessment systems in Korea should be revised so as to reflect the followings. First, the impact of national landuse planning change on the environment should be considered at the beginning of environmental impact assessment procedures. Second, the overlapping and greater impact of many projects, whose part is the subject of environmental impact assessment, upon surrounding metropolitan area should be simultaneously evaluated and the environmental pollution protection and abatement alternatives must be made according to the above impact of the projects. Thirdly, total effluent regulation of water pollution, air pollution and solid wastes should be enforced based on the self-purification of the metropolitan area environment.

  • PDF

Metropolitan Area Development Planning and Environmental Impact Assessment in Korea with Special Reference to Asan-bay Metropolitan Area Development Planning (광역권 개발과 환경영향평가)

  • Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.3
    • /
    • pp.63-71
    • /
    • 1995
  • This study analyzes the problems of environmental laws, development planning laws, Metropolitan Area Development Planning (MADP), and the level of environmental pollution at Asan-bay metropolitan area, where MADP will be realized in the near future. In order to prevent environmental pollution by the implementation of MADP, the Environmental Impact Assessment (EIA) Act and EIA systems in Korea should be revised so as to reflect the followings. First, the impact of national landuse planning changes on the environment should be considered at the beginning of the EIA procedures. Second, the overlapping and greater impact of many projects upon surrounding metropolitan areas should be simultaneously evaluated, though each project is the subject of EIA, and the environmental pollution protection and abatement alternatives must be made in accordance with the above impact of the projects. Thirdly, total effluent regulation of water pollution, air pollution and solid wastes should be enforced based on the self-purification of the metropolitan area environment.

  • PDF

Evaluation of Effluent Toxicity which were Exempted from Applying of Ecotoxicity Criteria (생태독성기준 미적용 업종 사업장 배출수 생태독성 수준 평가)

  • Kim, Jongmin;Shin, Kisik;Lee, Soohyung;Lee, Jungseo;Lee, Taekjune
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.197-202
    • /
    • 2017
  • This paper aimed to evaluate the test results of acute toxicity on effluent samples which were exempted from applying of ecotoxicity criteria. Total 316 effluent samples which were free from controlling of ecotoxicity regulation, were tested. Ratio of effluent samples which were exceeded the ecotoxicity criteria (TU > 1) indicated 23.7%. This ratio was a little bit higher than previous study (22.7%) on effluent samples which were controlled under ecotoxicity criteria. These results mean that our ecotoxicity management system is not appropriate and applying of ecotoxicity criteria to all effluent samples (82 industry categories) were needed in order to improve our ecotoxicity system. In addition, the same numeric criteria (TU 1 or 2) for all industry categories were proposed in consideration of these results. Ratio of effluent samples which exceeded the ecotoxicity criteria (TU > 1) with D. magna indicated 23.7%. However V. fischeri showed 14.6%. As a acute toxicity test organism, D. magna seemed to be more sensitive than V. fischeri. Ratio of samples which were exceeded TU 1 with D. magna by 24 h exposure period test indicated 35 %, whereas 48 h showed 41%.

Disinfection and Removal of SS and T-P Using DOF (Dissolved Ozone Flotation) (DOF(Dissolved Ozone Flotation)를 이용한 부유물질과 총인의 제거와 소득의 동시효과에 관한 연구)

  • Lee., Byoung-Ho;Kim, Sung-Hyuk;Lee, Sang-Bae;Kim, Mi-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.215-221
    • /
    • 2004
  • Effluent of wastewater treatment plant is to be disinfected to protect drinking water sources. DOF (Dissolved Ozone Flotation) was developed to meet this purpose. DOF was developed by combining DAF system with ozone. DAF system has good floating power with numerous microbubbles, and ozone has strong oxidation capability. And DOF system has good floating power and strong oxidation capability simultaneously. When DOF was applied to secondary wastewater effluent, color of 11CU in raw water which was secondary effluent was reduced to 1CU by the DOF system. Removal rate of other water quality parameters treated by DOF were also higher than that by DAF, which were proved the strength of oxidation capability of ozone. When ozone concentration of 3.3mg/l were applied in DOF system, general aerobic bacteria were reduced to 5CFU/ml from TNTC (Too many Numbers To Count). With the same ozone concentration, total coliform were not detected at all. These figures are under the numbers of drinking water regulation. These microbes were the target parameters of DOF. It was proved that DOF was very effective in disinfection of wastewater treatment plant effluent as well as in removal of color, turbidity, and T-P.

The control of point and non-point source nitrogen to prevent eutrophication of the Nakdong River basin, Korea

  • Kwak, Sunggue;Yun, Zuwhan
    • Membrane and Water Treatment
    • /
    • v.11 no.5
    • /
    • pp.345-351
    • /
    • 2020
  • Eutrophication of surface waters is commonly caused by excessive inputs of nutrients such as nitrogen and phosphorus. Nakdong River basin was chosen as the study area to investigate the effect of point and non-point source pollution of nitrogen on eutrophication in water body. Non-point source inputs of nitrogen accounted for approximately 84% in the total nitrogen input of the upper Nakdong river watershed, which mainly consists of agricultural land and forests. However, point source inputs of nitrogen accounted for 58~85% in the total nitrogen input of the middle and lower watersheds, including urban area. Therefore, for watershed near urban area, control of point source inputs of nitrogen may be an optimal method to control eutrophication. In this respect, the enforcing reduction of nitrogen in the final effluent of wastewater treatment facilities is needed. On the other hand, to enact more stringent nitrogen regulations, the LOT (limit of technology) and environmental impact should be considered. In this study nitrogen data were analyzed to propose new nitrogen regulations.

Application of Ti-salt Coagulant and Sludge Recycling for Phosphorus Removal in Biologically Treated Sewage Effluent (하수종말처리장의 인 처리시설에 티탄염 응집제 적용 및 슬러지 재활용)

  • Kim, Jong Beom;Park, Hee-Ju;Lee, Ki Won;Jo, A Ra;Kim, Myung Wan;Lee, Young Jun;Park, Se Min;Lee, Kwang Young;Shon, Ho Kyong;Kim, Jong-Ho
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.257-262
    • /
    • 2013
  • As the regulation of total phosphorus (T-P) concentration in biologically treated sewage effluent is reduced to 0.2~2 mg/L, flocculation process is recommended to remove T-P. In this study, the performance of Ti-salt coagulant was investigated in terms of dosage and pH in removing phosphorus and the collected sludge after Ti-salt flocculation was calcined to produce titania for effective sludge recycling. The flocculation performance was carried out using two methods: sedimentation and air floatation. Both methods were feasible to apply for Ti-salt flocculation. Ti-salt flocculation was effective in reducing phosphorus concentration in sewage effluent, which showed similar performance of alum ($Al_2(SO_4)_3$). The calcined sludge was recycled to titania which is the widely used metal oxide. Titania produed from Ti-salt sludge indicated similar characteristics of commercially-available P-25 in regard to photocatalytic activity and surface area. Therefore, this can be easily adopted to titania application by replacing P-25.

Problems of lake water management in Korea (한국의 호수 수질관리의 문제점)

  • 김범철;전만식;김윤희
    • Proceedings of the Korean Society of Environment and Ecology Conference
    • /
    • 2003.10a
    • /
    • pp.105-126
    • /
    • 2003
  • In Korea most of annual rainfall is concentrated in several episodic heavy rains during the season of summer monsoon and typhoon. Because of uneven rainfall distribution many dams have been constructed in order to secure water supply in dry seasons. The Han River system has the most dams among Korean rivers, and the river is a series of dams now. Reservoirs need different strategy of water quality control from river water. Autochthonous organic matter and phosphorus should be the major target to be controlled in lakes. In this Paper some problems are discussed that makes efforts of water quality improvement ineffective in lakes of Korea, even after the substantial investment to wastewater treatment facilities.1) Phosphorus is the key factor controlling eutrophication of lakes and the reduction ofphosphors should be the major target of water treatment. However, water quality management strategy in Korea is still stream-oriented, and focused on BOD removal from sewage. Phosphorus removal efficiency remains as low as 10-30%, because biological treatment is adopted for both secondary treatment and advanced treatment. The standard for TP concentration of the sewage treatment plant effluent is 6 mgP/l in most of regions, and 2 mg/l in enforced region near metropolitan water intake point. TP in the effluents of sewage treatment plants are usually 1-2 mg/1, and most of plants meet the effluent regulation without a further phosphorus removal process. The generous TP standard for effluents discourages further efforts to improve phosphorus removal efficiency of sewage treatment. Considering that TP standard for the effluent is below 0.1 mg/l in some countries, it should be amended to below 0.1 mg/l in Korea, especially in the watershed of large lakes.2) Urban runoff and combined sewer overflow are not treated, even though their total loading into lakes can be comparable to municipal sewage discharges on dry days. Chemical coagulation and rapid settling might be the solution to urban runoff in regard of intermittent operation on only rainy days.3) Aggregated precipitation in Korea that is concentrated on several episodic heavyrains per year causes a large amount of nonpoint source pollution loading into lakes. It makes the treatment of nonpoint source discharge by methods of other countries of even rain pattern, such as retention pond or artificial wetland, impractical in Korea.4) The application rate of fertilizers in Korea is ten times as high as the average ofOECD countries. The total manure discharge from animal farming is thought to be over the capacity of soil treatment in Korea. Even though large portion of manure is composted for organic fertilizer, a lot of nutrients and organic matter emanates from organic compost. The reduction of application rate and discharge rate of phosphorus from agricultural fields should be encouraged by incentives and regulations.5) There is a lot of vegetable fields with high slopes in the upstream region of the HanRiver. Soil erosion is severe due to high slopes, and fertilizer is discharged in the form of adsorbed phosphorus on clay surface. The reduction of soil erosion in the upland area should be the major preventive policy for eutrophication. Uplands of high slope must be recovered to forest, and eroded gullies should be reformed into grass-buffered natural streams which are wider and resistant to bank erosion.

  • PDF

Policy Directions of Total Maximum Daily Loads for the Scientific Management of Water Quality (과학적인 수질관리를 위한 오염총량관리제도의 추진 방안)

  • Park, Seok-Soon;Na, Yu-Mee;Na, Eun-Hye
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.2
    • /
    • pp.157-165
    • /
    • 2001
  • This paper presents the policy directions of total maximum daily loads(TMDL), which was recently adopted in Korea, for scientific management of water quality. The basic principles of water quality management are also discussed in this paper, along with the TMDL policy in United States as well as the previous policy in Korea. We discussed several unreasonable points out of the previous approaches, such as regulation of all point sources with equal standards, negligence of an assimilative capacity of the receiving water, and emphasis only on drinking water supply, etc.. For successful applications of the TMDL policy in Korea, the following directions are suggested: 1) the unit drainage basin for each TMDL application should be given, 2) the water body where the water quality standards should be maintained, needs to be guided, 3) the water quality parameters of TMDL should be given, 4) the technical guidances should be given for applications of water quality models, and 5) the seasonal TMDL would be allowed. In order to maximize the benefits of the TMDL policy, the local governments would need to implement the following strategies: 1) the increment of an assimilative capacity of the receiving water, 2) the effective controls of the non-point source pollution, 3) the advanced treatment of the point sources, 4) application of system optimization techniques along with effluent trade, and 5) utilization of watershed management systems.

  • PDF

Reverse Osmosis Treatment of Swine Wastewater with Various Pretreatment Systems (축산 폐수의 전처리 방법과 역삼투압 처리)

  • Park, Soon Ju;Kim, Moon Il;Kim, Do Yun;Chang, Ho Nam;Chang, Seung Teak
    • Clean Technology
    • /
    • v.9 no.2
    • /
    • pp.49-55
    • /
    • 2003
  • The generation of livestock wastewater in Korea amounts to $130,000m^3/day$, 0.43% of the total waste water volume, but which corresponds to 8.6% of total BOD loading. Furthermore this wastewater contains a large amount of nitrogen and phosphorus that are major causes of eutrophication in rivers and lakes. The average volume of livestock wastewater in a Korea's single farm is only $2.5m^3/day$, which necessitates development of a simple and economical process for the removal of nitrogen and phosphorus. Introduction of filtration method removes more than 90% of suspended solids. Subsequent application of reverse osmosis removes more then 95% of total nitrogen and phosphorus in the wastewater. The effluent of this treatment will yield less than 200 mg/L of total nitrogen and 1 mg/L of total phosphorous, which are lower than 260 mg/L of total N and 50 mg/L of total P, the regulation values of Ministry of Environment, Korea. Treating $2m^3/day$ of livestock wastewater was found to be feasible with the application of filtration and reverse osmosis and the electricity requirement was estimated to be about 30 Kwh/month.

  • PDF

Efficiency Assessment of Wastewater Treatment Plant and Groundwater Level by Pump and Treat Technology Applied for Petroleum Contaminated Site (유류오염 지하수 정화를 위한 양수처리법 적용시 지하수위 변화 및 수처리장치의 효율평가)

  • Cho, Chang-Hwan;Kim, Joon-Ho;Park, Min-Kyu;Kim, Tae-Hyung;Choi, Yoen-Soo;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.33-38
    • /
    • 2014
  • This study was performed to evaluate the applicability of pump and treat technology as well as to identify the changes of groundwater level by continuous pumping at the petroleum contaminated site. A total of 9 monitoring wells were installed at the site and the contaminant concentrations, TPH, benzene, toluene, ethylbenzene and xylene, of groundwater were measured. With the results of the groundwater monitoring, a total of 9 wells were set up for pumping contaminated groundwater in 3 locations. The waste water treatment facility with a capacity of $10m^3/hr$ was installed in the site and operated for about 1 year. The concentrations of the contaminated groundwater from the 3 pumping wells were exceeded groundwater regulation for benzene and TPH. However, the effluent concentration of benzene and TPH was under the regulation showing the maximum level of 0.011 mg/L and 1.2 mg/L during the operation periods. Groundwater levels were decreased by continuous pumping and those were not recovered during the operation period. Groundwater levels of PW-1,2, PW-3,4,5,6 and PW-7,8,9 were decreased about 5 m, 0.7 m, 2 m, respectively. The hydraulic conductivity (K) of the region of PW-1,2, PW-3,4,5,6 and PW-7,8,9 was estimated to be $6.143{\times}10^{-5}cm/sec$, $2.675{\times}10^{-5}cm/sec$, $1.198{\times}10^{-4}cm/sec$. Groundwater level was seemed to be affected not by hydraulic conductivity but by morphological effect. These results show that the pump and treat technology has high applicability for the restoration of petroleum contaminated groundwater but needs continuous monitoring to prevent rapid groundwater drawdown.