• 제목/요약/키워드: Total Disc Replacement

검색결과 20건 처리시간 0.022초

인공 추간판 치환술 후 경추의 생체역학적 특성 (Biomechanical Characteristics of Cervical Spine After Total Disc Replacement)

  • 박원만;주증우;김경수;이기석;김윤혁
    • 대한기계학회논문집A
    • /
    • 제33권7호
    • /
    • pp.637-644
    • /
    • 2009
  • We have analyzed the biomechanical characteristics of cervical spine after total disc replacement using finite element analysis. A finite element model of C2-C7 spinal motion segment was developed and validated by other experimental studies. Two types of artificial discs, semi-constraint and un-constraint, were inserted at C6-C7 segments. Inferior plane of C7 vertebra was fixed and 1Nm of moment were applied on superior plane of C2 vertebra with 50N of compressive load along follower load direction. Mobility of the cervical spine in which each artificial disc inserted was higher than that of intact one in all loading conditions. Also, high mobility at the surgical level after total disc replacement could lead higher facet joint force and ligaments axial stresses. The results of present study could be used to evaluate surgical option and validate the biomechanical characteristics of the implant in total disc replacement in cervical spine.

Cost-Effectiveness Analysis of Cervical Anterior Fusion and Cervical Artificial Disc Replacement in the Korean Medical System

  • Lee, Hyosang;Kim, Ui Chul;Oh, Jae Keun;Kim, Taehyun;Park, Sohee;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권1호
    • /
    • pp.83-89
    • /
    • 2019
  • Objective : This study is a retrospective cost-benefit analysis of cervical anterior interbody fusion and cervical artificial disc replacement, which are the main surgical methods to treat degenerative cervical disc disease. Methods : We analyzed 156 patients who underwent anterior cervical disc fusion and cervical artificial disc replacement from January 1, 2008 to December 31, 2009, diagnosed with degenerative cervical disc disorder. In this study, the costs and benefits were analyzed by using quality adjusted life year (QALY) as the outcome index for patients undergoing surgery, and a Markov model was used for the analysis. Only direct medical costs were included in the analysis; indirect medical costs were excluded. Data were analyzed with TreeAge Pro $2015^{TM}$ (TreeAge Software, Inc, Williamstown, MA, USA). Results : Patients who underwent cervical anterior fusion had a total cost of KRW 2501807/USD 2357 over 5 years and obtained a utility of 3.72 QALY. Patients who underwent cervical artificial disc replacement received 4.18 QALY for a total of KRW 3685949/USD 3473 over 5 years. The cumulative cost-effectiveness ratio of cervical spine replacement surgery was KRW 2549511/QALY (USD 2402/QALY), which was lower than the general Korean payment standard. Conclusion : Both cervical anterior fusion and cervical artificial disc replacement are cost-effective treatments for patients with degenerative cervical disc disease. Cervical artificial disc replacement may be an effective alternative to obtain more benefits.

Total Disc Replacement in Lumbar Degenerative Disc Diseases

  • Park, Chun Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권5호
    • /
    • pp.401-411
    • /
    • 2015
  • More than 10 years have passed since lumbar total disc replacement (LTDR) was introduced for the first time to the world market for the surgical management of lumbar degenerative disc disease (DDD). It seems like the right time to sum up the relevant results in order to understand where LTDR stands on now, and is heading forward to. The pathogenesis of DDD has been currently settled, but diagnosis and managements are still controversial. Fusion is recognized as golden standard of surgical managements but has various kinds of shortcomings. Lately, LTDR has been expected to replace fusion surgery. A great deal of LTDR reports has come out. Among them, more than 5-year follow-up prospective randomized controlled studies including USA IDE trials were expected to elucidate whether for LTDR to have therapeutic benefit compared to fusion. The results of these studies revealed that LTDR was not inferior to fusion. Most of clinical studies dealing with LTDR revealed that there was no strong evidence for preventive effect of LTDR against symptomatic degenerative changes of adjacent segment disease. LTDR does not have shortcomings associated with fusion. However, it has a potentiality of the new complications to occur, which surgeons have never experienced in fusion surgeries. Consequently, longer follow-up should be necessary as yet to confirm the maintenance of improved surgical outcome and to observe any very late complications. LTDR still may get a chance to establish itself as a substitute of fusion both nominally and virtually if it eases the concerns listed above.

Comparative Analysis between Total Disc Replacement and Posterior Foraminotomy for Posterolateral Soft Disc Herniation with Unilateral Radiculopathy : Clinical and Biomechanical Results of a Minimum 5 Years Follow-up

  • Kim, Kyoung-Tae;Cho, Dae-Chul;Sung, Joo-Kyung;Kim, Young-Baeg;Kim, Du Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권1호
    • /
    • pp.30-39
    • /
    • 2017
  • Objective : To compare the clinical outcomes and biomechanical effects of total disc replacement (TDR) and posterior cervical foraminotomy (PCF) and to propose relative inclusion criteria. Methods : Thirty-five patients who underwent surgery between 2006 and 2008 were included. All patients had single-level disease and only radiculopathy. The overall sagittal balance and angle and height of a functional segmental unit (FSU; upper and lower vertebral body of the operative lesion) were assessed by preoperative and follow-up radiographs. C2-7 range of motion (ROM), FSU, and the adjacent segment were also checked. Results : The clinical outcome of TDR (group A) was tended to be superior to that of PCF (group B) without statistical significance. In the group A, preoperative and postoperative upper adjacent segment level motion values were $8.6{\pm}2.3$ and $8.4{\pm}2.0$, and lower level motion values were $8.4{\pm}2.2$ and $8.3{\pm}1.9$. Preoperative and postoperative FSU heights were $37.0{\pm}2.1$ and $37.1{\pm}1.8$. In the group B, upper level adjacent segment motion values were $8.1{\pm}2.6$ and $8.2{\pm}2.8$, and lower level motion values were $6.5{\pm}3.3$ and $6.3{\pm}3.1$. FSU heights were $37.1{\pm}2.0$ and $36.2{\pm}1.8$. The postoperative FSU motion and height changes were significant (p<0.05). The patient's satisfaction rates for surgery were 88.2% in group A and 88.8% in group B. Conclusion : TDR and PCF have favorable outcomes in patients with unilateral soft disc herniation. However, patients have different biomechanical backgrounds, so the patient's biomechanical characteristics and economic status should be understood and treated using the optimal procedure.

The Option of Motion Preservation in Cervical Spondylosis: Cervical Disc Arthroplasty Update

  • Chang, Chih-Chang;Huang, Wen-Cheng;Wu, Jau-Ching;Mummaneni, Praveen V.
    • Neurospine
    • /
    • 제15권4호
    • /
    • pp.296-305
    • /
    • 2018
  • Cervical disc arthroplasty (CDA), or total disc replacement, has emerged as an option in the past two decades for the management of 1- and 2-level cervical disc herniation and spondylosis causing radiculopathy, myelopathy, or both. Multiple prospective randomized controlled trials have demonstrated CDA to be as safe and effective as anterior cervical discectomy and fusion, which has been the standard of care for decades. Moreover, CDA successfully preserved segmental mobility in the majority of surgical levels for 5-10 years. Although CDA has been suggested to have long-term efficacy for the reduction of adjacent segment disease in some studies, more data are needed on this topic. Surgery for CDA is more demanding for decompression, because indirect decompression by placement of a tall bone graft is not possible in CDA. The artificial discs should be properly sized, centered, and installed to allow movement of the vertebrae, and are commonly 6 mm high or less in most patients. The key to successful CDA surgery includes strict patient selection, generous decompression of the neural elements, accurate sizing of the device, and appropriately centered implant placement.

SVM 기법을 이용한 쉴드 TBM 디스크 커터 교환 주기 예측 (Prediction of replacement period of shield TBM disc cutter using SVM)

  • 나유성;김명인;김범주
    • 한국터널지하공간학회 논문집
    • /
    • 제21권5호
    • /
    • pp.641-656
    • /
    • 2019
  • 본 연구에서는 쉴드 TBM (Tunnel Boring Machine) 터널 디스크 커터의 적절한 교체 시기를 예측하기 위한 방법으로 머신러닝 기법을 사용한 방법을 제안하였으며, 이를 위해 국내 기 시공된 쉴드 TBM 현장의 데이터를 이용하여 다양한 머신러닝 알고리즘 중 SVM (Support Vector Machine)을 이용하여 예측 모델을 구축하고 그 성능을 평가하였다. 지반 조건별 디스크 커터의 마모와 높은 상관성을 갖는 TBM 기계 데이터와 디스크 커터 교체 이력을 분류하고, 이들을 SVM의 변수로 사용하여 3종류의 분류 함수를 적용하여 각각 학습을 한 후 예측을 수행한 결과, 각 지반 조건에 대해서 3종류의 SVM 분류 함수 중 전체적으로 RBF (Radial Basis Function) SVM의 예측성능이 가장 우수하며(평균적으로 80%의 정확도, 10% 오분류율), 지반 조건별로 구분 시 디스크 커터 교체 데이터의 수가 많을수록 예측 결과가 좋은 것으로 나타났다. 향후 많은 데이터를 축적하고 이를 모두 활용하여 학습모델을 지속적으로 발전시켜 나간다면 이와 같은 디스크 커터 교환주기를 예측하기 위한 머신러닝 기법의 실무 적용성이 매우 클 것으로 기대한다.

Treatment of Temporomandibular Joint Disorder by Alloplastic Total Temporomandibular Joint Replacement

  • Roh, Young-Chea;Lee, Sung-Tak;Geum, Dong-Ho;Chung, In-Kyo;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권6호
    • /
    • pp.412-420
    • /
    • 2013
  • The literature on alloplastic total temporomandibular joint (TMJ) replacement is encouraging, with acceptable improvement of treatment outcomes in terms of both pain level and jaw function. This is a case report on patients who suffered from degenerative joint disease and ankylosis after mandibular condyle fracture or prior TMJ surgery and were treated by TMJ replacement with condyle prosthesis. We obtained good results from the procedures, including total TMJ replacement.

Rare Intractable Cervicalgia Related to Exaggerated Disc Height Distraction : Report of Two Cases and Literature Review

  • Choi, Man Kyu;Kim, Sung Bum;Lee, Jun Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권4호
    • /
    • pp.530-536
    • /
    • 2018
  • We present two cases of unexpected postoperative intractable cervicalgia due to over-sized implant insertion during simple anterior cervical decompression and fusion (ACDF) or artificial disc replacement (ADR). These patients experienced severe cervicalgia mostly related to their neck motion even after standard cervical operations. In both cases, the restored disc heights after the operations were prominently greater than the preoperative disc heights. The patients had not responded to any of the conservative treatments, and unloading of these excessively distracted segments through ultimate revision surgery led to dramatic pain relief. This report emphasizes the increase in distractional forces that takes place after a standard ACDF or ADR, as well as the importance of a proper sized implant. It also includes the reviews of other biomechanical or clinical reports dealing with this issue, thereby cautioning the surgeons not to disregard these factors, which might have an adverse effect in patients with cervicalgia even after radiographically successful cervical procedures.

추간판 치환술이 요추분절에 미치는 생체역학적 영향 : 유한요소해석 (Biomechanical Effect of Total Disc Replacement on Lumbar Spinal Segment : A Finite Element Analysis)

  • 박원만;김기택;홍규표;김윤혁;오택열
    • 한국CDE학회논문집
    • /
    • 제13권1호
    • /
    • pp.58-66
    • /
    • 2008
  • The artificial discs have recently used to preserve the motion of the treated segment in lumbar spine surgery. However, there have been lack of biomechanical information of the artificial discs to explain current clinical controversies such as long-term results of implant wear and excessive facet contact forces. In this study, we investigated the biomechanical effects of three artificial implants on the lumbar spinal segments by finite element analysis. The finite element model of intact lumbar spine(L1-S) was developed and the three implants were inserted in L4-L5 segment of the spine model. 5 Nm of flexion and extension moments were applied on the superior plate of L1 with 400 N of compressive load. Excessive motions and high facet contact forces at the surgical level were generated in the all three implanted models. In the flexion, the peak von-Mises stresses in the semi-constrained type implant was higher than those in the un-constrained type implant which would cause wear on the polyethylene core. The results of the study would provide a biomechanical guideline for selecting optimal surgical approach or evaluating the current design of the implants, or developing a new implant.