• Title/Summary/Keyword: Torso

Search Result 325, Processing Time 0.016 seconds

Measurement of shoulder motion fraction and motion ratio (견관절 운동 분율의 측정)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2006
  • Purpose : This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. Materials and Methods : We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR(computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was $15^{\circ},\;19^{\circ},\;22^{\circ}$ to the cephald for the parallel scapular spine, and the tilting of torso was external oblique $40^{\circ},\;36^{\circ},\;22^{\circ}$ for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age(20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, $90^{\circ}$ and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. Results : While the arm elevation was $90^{\circ}$, the shoulder motion fraction was 1.22(M), 1.70(W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84, and left was 1.57, 1.32. In right dominant arm(78%), $90^{\circ} and Full motion fraction was 1.58, 1.43, in left(22%) 1.82, 1.94. In generation 20, $90^{\circ} and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28, 60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. Conclusion : The criterior of motion fraction was useful reference for clinical dignosis the shoulder instability.

  • PDF

Characteristics and Significance of the Huirang Daesa Sculpture at Haeinsa Temple in Hapcheon (합천(陜川) 해인사(海印寺) 희랑대사상(希朗大師像)의 특징과 제작 의미)

  • Jeong, Eunwoo
    • MISULJARYO - National Museum of Korea Art Journal
    • /
    • v.98
    • /
    • pp.54-77
    • /
    • 2020
  • Produced during the Goryeo period (718-1392), the statue of the monk Huirang Daesa at Haeinsa Temple in Hapcheon is almost life-size, with a height of 82.4 cm, a width of 66.6 cm at the knees, and a maximum width of 44 cm at the torso (front and back). Notably, it is the only known example of an East Asian Buddhist sculpture made from wood and dry lacquer that was formed by joining the front and back halves. However, a similar technique was used on a dry lacquer statue of the Medicine Buddha at Cheongnyangsa Temple in Bonghwa, which is estimated to date from the late Goryeo or early Joseon period. As such, this technique is thought to represent this particular time period. In an eighteenth-century travelogue about a trip to Mt. Gayasan, the author describes a sculpture that is believed to be the statue of Huirang Daesa at Haeinsa Temple, based on various unique features that closely correspond to the sculpture's current appearance. For example, the sculpture is said to have a hole in the chest and rough, knobby tendons and bones, two features that can still be seen today. Another sculpture of a Buddhist monk who was active in the western regions during the third and fourth century also has a hole in the chest, which is said to be a symbol of spiritual strength. The travelogue also states that the statue was lacquered black at the time, which means that it must have been painted with its present colors some time in the nineteenth century. Over time, the sculpture has been enshrined in various halls of Haeinsa Temple, including Haehaengdang, Jinsangjeon, and later Josajeon (Hall of the Patriarchs), and Bojangjeon. Records show that images of Buddhist monks, or "seungsang," were produced in Korea as early as the Three Kingdoms period (18 BCE-660 CE), but few of these works have survived. At present, only four such sculptures are extant, including the images of Huirang Daesa from the Goryeo period, and those of Monk Naong and Uisang Daesa from the Joseon period. Of these, the sculpture of Huirang Daesa has special significance for its early production date (i.e., CE. tenth century), outstanding production techniques, and superb artistic quality, realistically capturing both the external appearance and internal character of the subject. The tradition of producing, sanctifying, and worshipping statues of monks was prevalent not only in Korea, but also in China and Japan. However, each country developed its own preferred materials and techniques for producing these unique images. For example, while China has a large number of mummified Buddhist images (yuksinbul), Japan produced diverse images with various materials (e.g., dry lacquer, wood, clay) according to period. But despite the differences in materials and techniques, the three nations shared the same fundamental purpose of expressing and honoring the inherent spirituality of the monks.

Development of Eggs, Larvae and Juveniles of the Hypomesus nipponensis (Pisces:Osmeridae) from Western Coastal, Daeho-man (서해안 대호만에 서식하는 빙어 Hypomesus nipponensis의 난발생 및 자치어 형태발달)

  • Jae-Min Park;Dong-Jae Yoo;Jeong-Nam Yu;Seong-Ryul Lim;Dal-Young Kim;Kyeong-Ho Han
    • Korean Journal of Ichthyology
    • /
    • v.36 no.2
    • /
    • pp.120-128
    • /
    • 2024
  • In this study, the characteristics of the early life history were investigated for the Hypomesus nipponensis in the west coast Daeho Bay. Egg's were adhesive eggs that had the property of sinking in water in a circular shape. The size of mature eggs was 0.52~0.66 (average of 0.59±0.03, n=30) mm. The hatching time took 140 hours at a water temperature of 22~23℃. Immediately after hatching, the yolk sac larvae was 4.78~5.60 (average of 5.25±0.26, n=30) mm in total length, and the mouth and anus were not completely opened. On the 7 days after hatching, the preflexion larvae was 5.91~6.64 (6.32±0.21) mm in total length, and the mouth and anus were opened, and feeding activities were started. On the 25 days after hatching, the flexion larvae was 9.70~12.3 (10.2±0.63) mm in total length, and the end of the spine at the tail end began to bend upward. On the 42 days after hatching, the postflexion larvae was 14.1~18.8 (16.9±1.44) mm in total length, and the end of the spine at the tail was completely bent at 45°. On the 56 days after hatching, it reached the integer with 10 dorsal fins, 16 anal fins, 7 ventral fins, and 19 caudal fins. According to the study, there were spot-shaped melanophore vesicles under the pectoral fins during the incubation period, the different positions of the egg yolk compared to the battlefield, the deposition of melanophore vesicles on the back and under the body of the caudal part during the postflexion larvae period, and the absence of melanophore vesicles on the torso between the head and the starting point of the dorsal fin. It was distinguished from related species in that melanophore vesicles were deposited in one row from the back of the body to the caudal part during the juvenile period.

Application of MicroPACS Using the Open Source (Open Source를 이용한 MicroPACS의 구성과 활용)

  • You, Yeon-Wook;Kim, Yong-Keun;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Tae-Sung;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Recently, most hospitals are introducing the PACS system and use of the system continues to expand. But small-scaled PACS called MicroPACS has already been in use through open source programs. The aim of this study is to prove utility of operating a MicroPACS, as a substitute back-up device for conventional storage media like CDs and DVDs, in addition to the full-PACS already in use. This study contains the way of setting up a MicroPACS with open source programs and assessment of its storage capability, stability, compatibility and performance of operations such as "retrieve", "query". Materials and Methods: 1. To start with, we searched open source software to correspond with the following standards to establish MicroPACS, (1) It must be available in Windows Operating System. (2) It must be free ware. (3) It must be compatible with PET/CT scanner. (4) It must be easy to use. (5) It must not be limited of storage capacity. (6) It must have DICOM supporting. 2. (1) To evaluate availability of data storage, we compared the time spent to back up data in the open source software with the optical discs (CDs and DVD-RAMs), and we also compared the time needed to retrieve data with the system and with optical discs respectively. (2) To estimate work efficiency, we measured the time spent to find data in CDs, DVD-RAMs and MicroPACS. 7 technologists participated in this study. 3. In order to evaluate stability of the software, we examined whether there is a data loss during the system is maintained for a year. Comparison object; How many errors occurred in randomly selected data of 500 CDs. Result: 1. We chose the Conquest DICOM Server among 11 open source software used MySQL as a database management system. 2. (1) Comparison of back up and retrieval time (min) showed the result of the following: DVD-RAM (5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) The wasted time (sec) to find some data is as follows: CD ($156{\pm}46$), DVD-RAM ($115{\pm}21$) and Conquest DICOM Server ($13{\pm}6$). 3. There was no data loss (0%) for a year and it was stored 12741 PET/CT studies in 1.81 TB memory. In case of CDs, On the other hand, 14 errors among 500 CDs (2.8%) is generated. Conclusions: We found that MicroPACS could be set up with the open source software and its performance was excellent. The system built with open source proved more efficient and more robust than back-up process using CDs or DVD-RAMs. We believe that the operation of the MicroPACS would be effective data storage device as long as its operators develop and systematize it.

  • PDF

Comparison and Evaluation of the Effectiveness between Respiratory Gating Method Applying The Flow Mode and Additional Gated Method in PET/CT Scanning. (PET/CT 검사에서 Flow mode를 적용한 Respiratory Gating Method 촬영과 추가 Gating 촬영의 비교 및 유용성 평가)

  • Jang, Donghoon;Kim, Kyunghun;Lee, Jinhyung;Cho, Hyunduk;Park, Sohyun;Park, Youngjae;Lee, Inwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.54-59
    • /
    • 2017
  • Purpose The present study aimed at assessing the effectiveness of the respiratory gating method used in the flow mode and additional localized respiratory-gated imaging, which differs from the step and go method. Materials and Methods Respiratory gated imaging was performed in the flow mode to twenty patients with lung cancer (10 patients with stable signals and 10 patients with unstable signals), who underwent PET/CT scanning of the torso using Biograph mCT Flow PET/CT at Bundang Seoul University Hospital from June 2016 to September 2016. Additional images of the lungs were obtained by using the respiratory gating method. SUVmax, SUVmean, and Tumor Volume ($cm^3$) of non-gating images, gating images, and additional lung gating images were found with Syngo,bia (Siemens, Germany). A paired t-test was performed with GraphPad Prism6, and changes in the width of the amplitude range were compared between the two types of gating images. Results The following results were obtained from all patients when the respiratory gating method was applied: $SUV_{max}=9.43{\pm}3.93$, $SUV_{mean}=1.77{\pm}0.89$, and $Tumor\;Volume=4.17{\pm}2.41$ for the non-gating images, $SUV_{max}=10.08{\pm}4.07$, $SUV_{mean}=1.75{\pm}0.81$, and $Tumor\;Volume=3.56{\pm}2.11$ for the gating images, and $SUV_{max}=10.86{\pm}4.36$, $SUV_{mean}=1.77{\pm}0.85$, $Tumor\;Volume=3.36{\pm}1.98$ for the additional lung gating images. No statistically significant difference in the values of $SUV_{mean}$ was found between the non-gating and gating images, and between the gating and lung gating images (P>0.05). A significant difference in the values of $SUV_{max}$ and Tumor Volume were found between the aforementioned groups (P<0.05). The width of the amplitude range was smaller for lung gating images than gating images for 12 from 20 patients (3 patients with stable signals, 9 patients with unstable signals). Conclusion In PET/CT scanning using the respiratory gating method in the flow mode, any lesion movements caused by respiration were adjusted; therefore, more accurate measurements of $SUV_{max}$, and Tumor Volume could be obtained from the gating images than the non-gating images in this study. In addition, the width of the amplitude range decreased according to the stability of respiration to a more significant degree in the additional lung gating images than the gating images. We found that gating images provide information that is more useful for diagnosis than the one provided by non-gating images. For patients with irregular signals, it may be helpful to perform localized scanning additionally if time allows.

  • PDF