• 제목/요약/키워드: Torque evaluation

검색결과 294건 처리시간 0.022초

Clinical presentation of a horse-derived biomaterial and its Biocompatibility: A Clinical Case Report

  • Koo, Ki-Tae;Park, Jang-Yeol;Park, Jun-Seok;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • 제39권sup2호
    • /
    • pp.287-291
    • /
    • 2009
  • Purpose: The objective of this clinical presentation was to present a clinical case series report of socket preservation, sinus augmentation, and bone grafting using a horse-derived biomaterial. Methods: A horse-derived biomaterial was used in 8 patients for different indications including socket preservation following tooth extraction, osseous bone grafting, and sinus augementation procedures. Surgeries were performed by a well trained specialist and clinical radiographs were obtained at designated intervals. Biopsy cores of 2 ${\times}$ 8 mm prior to implant placement was obtained following a healing interval of 4 - 6 months. A clinical and histologic evaluation was performed to evaluate the clinical effectiveness and biocompatibility of the biomaterial. Results: All surgeries in 8 patients were successful with uneventful healing except for one case with membrane exposure that eventually resulted with a positive outcome. Radiographic display of the healing phase during different intervals showed increased radiopacity of granular nature as the healing time increased. No signs of adverse effect or infection was observed clinically and the tissues surrounding the biomaterial seemed well-tolerated with good intentional healing. The augmented sinuses healed uneventfully suggesting in part, good biocompatibility of the biomaterial. Dental implants placed following socket preservation were inserted with high initial torque suggesting good initial stability and bone quality. Conclusions: Our results show that at least on a tentative level, a horse-derived biomaterial may be used clinically in socket preservation, sinus augmentation, bone grafting techniques with good intentional healing and positive results.

하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석 (PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION)

  • 조혜원;김난영;김유리
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

자화침 시스템을 이용한 경락전위 유발효과 및 근피로 회복 평가 (Evaluation of Muscle Fatigue Recovery Effect and Meridian Potential Change using Magnetic Acupuncture System)

  • 김수병;박선우;안순재;이나라;이승욱;민세은;김영호;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권1호
    • /
    • pp.83-92
    • /
    • 2012
  • Objectives : The purpose of this research was to develop the magnetic acupuncture system which used solenoid coil for magnetizing acupuncture needle. The system could generate the meridian electric potential (MEP) similar to the potential by manual acupuncture. Thus, we tried to confirm the therapeutic effect that is caused by the MEP generation. Methods : To confirm the MEP, we stimulated the magnetic acupuncture with at 2Hz, $92.7{\pm}2mT$, PEMFs (Pulsed Electro-Magnetic Fields) at ST37 and measured the evoked potential between ST36 and ST41. Also, we conducted a fatigue recovery test using isokinetic exercise in order to identify the therapeutic effect on musculoskeletal disorders. We chose LR9 as a stimulation point. To observe the state of fatigue, we measured the EMG and analyzed median frequency and peak torque for 20minutes. Results : We observed that MEP which incurred from magnetic acupuncture was higher than he reported MEP induced by manual acupuncture. Moreover, its modes were divided into two types by the direction of magnetic flux. When generating magnetic flux in the direction of acupoint, the positive peak voltage of the MEP was generated. In contrast, negative peak voltage of the MEP was generated whenever meganetic flux generated in the outward direction. As a result of fatigue recovery, the median frequency (MF) of the magnetic acupuncture group were recovered faster than that of the non-stimulation group. However, the peak torques of both groups were not restored until after 20 minutes. Conclusions : We confirmed that the magnetic acupuncture system can lead to the MEP similar to manual acupuncture. Moreover, the MEP had a therapeutic effect on the musculoskeletal disorders.

수중용 TAS윈치 전개/회수 성능 안정화 방안에 관한 연구 (A Study on Stabilization of Underwater TAS Winch System Deploy/Recover Operation Performance)

  • 장호성;조규룡;황재교;이상용;김용태
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.472-482
    • /
    • 2019
  • 본 논문은 수중용 TAS윈치 전개/회수 성능 안정화 방안에 대한 내용을 서술하고 있다. TAS윈치는 함미에 장착되어 자함과 이격되어 운용되는 센서, 예인케이블 및 꼬리로프의 전개/회수 기능을 수행하고, TAS에 대한 전원공급 경로, 수중환경 정보 및 수신된 음향신호 송/수신을 위한 데이터 전송 경로 제공 역할을 수행한다. TAS윈치 시험평가 과정에서 간헐적으로 TAS 전개 중 멈춤현상 및 회전속도 변동현상이 식별되었다. TAS 전개/회수에 필요한 토크를 제공하는 구성요소인 윈치모터에 대한 고장분석 결과, 구성품 중 회전자의 정렬 틀어짐으로 인한 편심현상에 따른 자기장 왜곡이 발생한 것을 확인하였다. 자기장 왜곡 발생 방지를 위해 윈치모터 회전자 및 슬립링 등 윈치모터 구성품의 고정성 향상 방안을 제안하였다. 제안된 방안에 대한 신뢰성 확보를 위해 LBTS 환경에서 TAS윈치 운용환경을 모사하여 TAS윈치 전개/회수 성능을 검증하였다. 최종적으로 TAS윈치 전개/회수 성능 뿐만 아니라 해상에서 TAS윈치를 운용할 경우 요구되는 함 속력 및 타각별 TAS 지속 운용능력과 같은 여러 가지 항목에 대한 해상 시험평가를 수행함으로써 설계 요구조건 만족 및 제안 방안에 대한 타당성을 검증하였다.