• Title/Summary/Keyword: Torque Capacity

Search Result 213, Processing Time 0.026 seconds

A Numerical Study on the Automotive Torque Converter(Part II) -Blade Angles and Performances- (자동차용 토크 컨버터의 수치해석적 연구(Part II) -날개각과 성능-)

  • Park, J.I.;Cho, K.R.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.174-184
    • /
    • 1998
  • The situation frequently occurs in which the input torque capacity of the torque converter should be changed. It is known that the modification of the outlet blade angles of the torque converter elements is suitable for such situation with the outer diameter of flow path of the converter maintained. But so far it has been difficult to predict correctly the converter characteristics as well as the effect of outlet angles on torque capacity in the past numerical methods. In the present numerical method introducing the interrow mixing planes, the torque capacity was satisfactorily estimated and it was shown that the torque capacity could be effectively changed by modifying the outlet blade angles of pump and stator.

  • PDF

Design and Flow Analysis of Torque Converter (Torque Converter의 설계 및 유동해석)

  • Park, J. I.;Cho, K. R.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.02a
    • /
    • pp.3-10
    • /
    • 1998
  • The situation frequently occurs in which the input torque capacity of the converter should be changed. It is known that the modification of the ou angles of the torque converter elements is suitable for such situation with diameter of flow path of the converter maintained. But so far it has been, predict correctly the converter characteristics as well as the effects of oulet torque capacity in the past numerical methods. In the present numeric introducing the interrow mixing planes, the torque capacity was satifactorily and it was shown that the torque capacity could be effectively changed by the oulet blade angles of pump and stator.

  • PDF

Analysis of Dynamics Characteristics for Friction Elements in Automatic Transmission (자동변속기 마찰요소의 동특성 해석)

  • 최영종;정우진;김성원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.9-19
    • /
    • 1997
  • In this paper, the modeling and analysis of dynamic characteristics has been carried out for friction clutches and brakes in an automatic transmission. From the operating oil pressure generated by the valve-body, time delay by check valve and the movement of piston has been examined. Also torque capacity and torque transferred at the clutch is studied. Heat capacity and temperature distribution at the reaction plate of clutch are codeled by time-dependent, nonhomogeneous partial differential equation, and brake torque, brake time, and the amount of heat generated are investigated. It is found that the time delay at the check valve is very short but dominant at the spool.

  • PDF

A study on torque measuring technique for track drive unit of earthmoving equipment with very large capacity (대형 건설장비용 주행유닛의 토크 측정기술에 관한 연구)

  • Lee, Yong-Bum;Han, Seung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.4
    • /
    • pp.97-103
    • /
    • 2009
  • Since a demand for an extensive range of earthmoving equipment like a hydraulic excavator with a capacity of 85tons has been asked in construction fields, a performance of its track drive unit has to be verified experimentally. Among the verification of the performances, a torque measurement is at issue, in which a torque meter is utilized widely. However, the very large scaled torque meter is necessary when a discharged torque from the track drive unit is increased significantly. In addition, the price for experimental set-up of a torque meter is too high due to its limitation of the geometry such as long length, and a break down in operation occurs frequently. In this study, to measure a high torque up to 200,000Nm, a new technique was proposed as an alternative of conventional measurement by using a torque meter. The new technique enables to measure the high torque stably in a compact space via a torque arm and two load cells. The experimental results showed a propriety of the proposed torque measuring technique for a track drive unit with very large capacity.

  • PDF

Estimation of ultimate torque capacity of the SFRC beams using ANN

  • Engin, Serkan;Ozturk, Onur;Okay, Fuad
    • Structural Engineering and Mechanics
    • /
    • v.53 no.5
    • /
    • pp.939-956
    • /
    • 2015
  • In this study, in order to propose an efficient model to predict the torque capacity of steel fiber reinforced concrete (SFRC) beams, the existing experimental data related to torsional response of beams is reviewed. It is observed that existing data neglects the effects of some parameters on the variation of torque capacity. Thus, an experimental research was also conducted to obtain the effects of neglected parameters. In the experimental study, a total of seventeen SFRC beams are tested against torsion. The parameters considered in the experiments are concrete compressive strength, steel fiber aspect ratio, volumetric ratio of steel fibers and longitudinal reinforcement ratio. The effect of each parameter is discussed in terms of torque versus unit angle of twist graphs. The data obtained from this experimental research is also combined with the data got from previous studies and employed in artificial neural network (ANN) analysis to estimate the ultimate torque capacity of SFRC beams. In addition to parameters considered in the experiments, aspect ratio of beam cross-section, yield strengths of both transverse and longitudinal reinforcements, and transverse reinforcement ratio are also defined as parameters in ANN analysis due to their significant effects observed in previous studies. Assessment of the accuracy of ANN analysis in estimating the ultimate torque capacity of SFRC beams is performed by comparing the analytical and experimental results. Comparisons are conducted in terms of root mean square error (RMSE), mean absolute error (MAE) and coefficient of efficiency ($E_f$). The results of this study revealed that addition of steel fibers increases the ultimate torque capacity of reinforced concrete beams. It is also found that ANN is a powerful method and a feasible tool to estimate ultimate torque capacity of both normal and high strength concrete beams within the range of input parameters considered.

A Numerical Study of Unsteady Wake Flow Characteristics in a Torque Converter (토크 컨버터 내부의 비정상 후류 유동특성에 대한 수치해석 연구)

  • Won, Chan-Shik;Hur, Nahmkeon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.705-710
    • /
    • 2004
  • In the present study, a transient incompressible viscous turbulent flow is simulated for the automotive torque converter with moving mesh technique. For the analysis, entire torque converter flow passages are modeled. Computed torque ratio, capacity factor and efficiency show a good agreement with the experiment data. The flow instabilities characterized by back-flow and wake etc. appeared in some cascade passages are shown to be Propagating along tangential direction. These flow patterns are mainly influenced by the pump and turbine blade passing and can't be predicted through conventional steady simulation with a mixing plane approach. The understanding of the unsteady flow characteristics in a torque converter achieved in the present study may lead to the optimal design of a torque converter.

  • PDF

A Numerical Study of Unsteady Wake Flow Characteristics in a Torque Converter (토크 컨버터 내부의 비정상 후류 유동특성에 대한 수치해석 연구)

  • Won, Chan-Shik;Hur, Nahm-Keon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.5 s.38
    • /
    • pp.36-41
    • /
    • 2006
  • In the present study, a transient incompressible viscous turbulent flow is simulated for the automotive torque converter with moving mesh technique. For the analysis, entire torque converter flow passages are modeled. Computed torque ratio, capacity factor and efficiency show a good agreement with the experiment data. The flow instabilities characterized by back-flow and wake etc. appeared in some cascade passages are shown to be propagating along tangential direction. These flow patterns are mainly influenced by the pump and turbine blade passing and can't be predicted through conventional steady simulation with a mixing plane approach. The understanding of the unsteady flow characteristics in a torque converter achieved in the present study may lead to the optimal design of a torque converter.

A Study on the Transmitted Torque of Self Clamping Friction Clutch (자기 체결 마찰 클러치의 전달 토크에 관한 연구)

  • Wang, Jee-Seok;Kim, Jong-Do;Yoon, Hee-Jong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1149-1156
    • /
    • 2008
  • The principle of self clamping friction clutch is presented in this paper and the transmitted torque capacity is also calculated. In order to enlarge the friction force, a part of rotating force of driving side is converted to normal force of friction materials by clamping arm. The increased normal force of friction materials assures the large friction force and the transmitted torque capacity of clutch becomes large. The self clamping friction clutch is adopted in the tube type air pressure clutch and the condition of stability is investigated. It is proven that the inclined angle of clamping arm and the friction factor of friction materials are the essential elements in stability and torque capacity of self clamping friction clutch. The transmitted torque capacity of self clamping friction clutch is compared with air pressure clutch. The normal force of friction lining is magnified by 1/(1-k) and the transmitted torque capacity is also magnified with same proportion comparing with air pressure clutch. The larger the friction factor of friction lining, the larger the magnification factor. The longer the clamping arm, the smaller the magnification factor. It must be also noted that the value of k=${\mu}Y/X$ is the criterion of stability. If the value of k=${\mu}Y/X$ is greater than or equal to 1, the self clamping friction clutch is unstable and it can not be used as clutch.

Effect of Configuration of Shaft and Helix Plate on Bearing Capacity of Moderate-size Helical Pile : II. Bearing Capacity Prediction (중소구경 헬리컬 파일의 축과 원판의 형상이 지지력에 미치는 영향 평가 : II. 이론식과 토크에 의한 지지력 예측 비교)

  • Lee, Jongwon;Lee, Dongseop;Na, Kyunguk;Choi, Hangseok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.2
    • /
    • pp.41-47
    • /
    • 2014
  • Various prediction methods for the bearing capacity of helical piles have been introduced with consideration of both the steel shaft and the helix plates attached to the shaft. In this paper, three representative methods, that is, individual bearing method, cylindrical shear method, and torque correlation method are discussed and compared to each other. The prediction methods were verified by comparing with a series of loading test results performed on moderate-size helical piles from the companion paper. As a result, the measured bearing capacity is greater than the bearing capacity predicted by the cylindrical shear method, but smaller than that of the individual bearing method. In addition, the bearing capacity predicted by the torque correlation method is in good agreement with the measured bearing capacity.

Experimental Investigation and Performance Test of Heavy Duty Torque Converter (중부하 토크 컨버터의 실험적 성능분석)

  • Lee, Hae-Jong;kim, Se-Hyun;Lee, Chung-Seub;Lee, Sang-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.690-695
    • /
    • 2004
  • The present study is an investigation on the characteristics of heavy load toque converter by experimental process. To get the dynamic performance, the dynamometer was used with a parameters of speed, torque, oil pressure and oil flux, etc. The torque converter was tested for various input speed, output oil pressure and input oil flow rate. All experiments were investigated in case that the speed ratio is increased. The torque ratio and capacity factor was in inverse proportion to speed. Engine revolution had a more effects at region of low speed ratio. But, the opposite phenomena were represented increase of efficiency. In result of this experiments, the characteristics of torque converter were not influenced by oil pressure and oil flux.

  • PDF