• Title/Summary/Keyword: Top floor

Search Result 240, Processing Time 0.022 seconds

A Optimization of Fire Safety Design in Multiplex Cinema Theater (국내 복합상영관 시설의 방재대책에 관한 연구)

  • 허준호;윤명오
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.43-50
    • /
    • 2002
  • 21C, Multiplex Cinema Theater is made from movie industry developed and become a place where we can spend our free time and consuming. But, theater users, who are many and unspecified persons, are short of information on the Multiplex Cinema Theater, so that they may be injured or killed at the occurrence of fire accident. Particularly, Multiplex Cinema Theater is a place that underground space or top floor in highrise building had many people in theaters. However, this problem is difficult to solve that to protect human being and properties at the occurrence of fire accident in the Multiplex Cinema Theater, In order to overcome such problems, Multiplex Cinema Theater need fire protection solutions facilities concerning particulars to pay attention to the safety on a fire and evacuation. This study analysed Multiplex Cinema Theater concept and computer simulation for risk point.

Comparative of Energy-Saving by Green Roof Type on Urban Office Building (도심 오피스건물의 옥상녹화 조성 유형별 건물에너지 절감 비교 연구)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Joo, Chang-Hun;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1437-1446
    • /
    • 2014
  • This study, the urban energy used office building green roof type composition of the target by analyze building energy reductions. Green roof is total 6 types(type A~F) were selected, EnergyPlus the energy simulation programs were used. Top floor of green roof types evaluation, the reduction of the cooling peak load type E(1.26%), type D(1.30%), type C(1.37%), type B(1.45%), type F(1.49%), and heating peak load is type D(1.32%), type E(1.40%), type C(1.47%), type F(1.69%), type B(2.13%) order. Annual cooling load of heating load is reduced more than about 1% effect. The heating load reduction ratio for a maximum of 9% respectively. Cooling peak load of the building energy performance evaluation of type F > type B > type C > type D > type E in the order and in the case of peak loads heating type B > type F > type D > type E>type C order. Annual total energy use reduction of 1.07 to 1.22% and earn, type B in the best good. In primary energy use reductions in the presence of a green roof were in the 4249~4876 kWh/yr. Annual $CO_2$ emissions reductions of unapplied type A were analyzed on average 469.78 kg.

A Study on the Direction of the Interior Deisgn of Welfare Facility -Focus on Cafeteria for Employee- (기업체 복지시설의 실내디자인 방향에 관한 연구 -직원식당을 중심으로-)

  • 오도엽
    • Korean Institute of Interior Design Journal
    • /
    • no.17
    • /
    • pp.22-29
    • /
    • 1998
  • As the trend shows that corporate investment for staff's welfare facilities has increased alongside employee's enhanced economic and conscious level which has resulted from economic growth and industrialization this study aims at analyzing interior design elements in staff's welfare facilites especially in cafeteria and suggesting new directions for designing those spaces. The method and scope of this study in firstly to described general points such as function and role of public food service and interior design elements in staff's cafeteria and then to grasp and analyze the present conditions of the staff's cafeteria for enterprises and financial organizations which has been built after 1990. The conclusion of his study can be summarized as follows : First it is desirable to locate employee's cafeteria on upper or top floor which has relatively good atmosphere. Second it is recommended to make overall atmosphere of employee's cafeteria impressive and in commercial restaurant. Third the separation of service circulation serveries and eating area is necessary. Fourth material for each parts should be easy to maintain and durable. Fifth more illuminance that the regulation is recommended and lighting fixture should be selected in terms of economics and maintenance. Sixth selecting bright and warm colors with partial application of accent colors is effective. Seventh furniture should be harmonized with the ambience of the space and required to be convenient and durable. Eighth to provide visual and auditory pleasure during eating it is desirable to equip the minimal A/V system. In addition diverse aspects such as improving employee's welfare caring for company the way of treating employee an boosting corporate images should be considered when designing staff's cafeteria and interior designer should be able to satis managerial aspects productivity and effectiveness as well as pursuing functional aesthetic facts.

  • PDF

The Progress of Fast Reactor Technology Development in China

  • Yang, Hong-Yi;Xu, Mi
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.220-237
    • /
    • 2004
  • China, as a developing country with a great number of population and relatively less energy resources, reasonably emphasizes the nuclear energy utilization development. For the long term sustainable energy supply, as for nuclear application the basic strategy of PWR-FBR-Fusion has been settled and envisaged. Due to the economy and experience reasons the nuclear power and technology development with a moderate style are kept in China up to now. In China mainland apart from two NPPs with the total capacity of 2.1 GWe in operation, four NPPs are under construction and two NPPs are planned for the Tenth Five Year Plan(2001-2005). Also another one or two NPPs are still in discussion. It could be foreseen that the total nuclear power capacity will reach 8.5GWe before the year 2005 and 14-15 GWe before 2010 respectively. As the first step for the Chinese fast reactor engineering development the 65MWt China Experimental Fast Reactor(CEFR) is under construction. The main components of primary, secondary and tertiary circuits and of fuel handling system have been ordered. The reactor building under construction has reached the top namely 57m above the ground. More than one hundred components and shielding doors have been installed. It is planned that the construction of reactor building with about 40,000$m^2$ floor surface will be completed in the end of the year 2002 and envisaged that the first criticality of the CEFR will be in the end of 2005. The second step of the Chinese fast reactor engineering development is a 300MWe Prototype Fast Breeder Reactor which is only under consideration up to now. Some important technical selections have been settled, but its design has not yet started.

  • PDF

Shaking table test of wooden building models for structural identification

  • Altunisik, Ahmet C.
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.67-77
    • /
    • 2017
  • In this paper, it is aimed to present a comparative study about the structural behavior of tall buildings consisting of different type of materials such as concrete, steel or timber using finite element analyses and experimental measurements on shaking table. For this purpose, two 1/60 scaled 28 and 30-stories wooden building models with $40{\times}40cm$ and $35{\times}35cm$ ground/floor area and 1.45 m-1.55 m total height are built in laboratory condition. Considering the frequency range, mode shapes, maximum displacements and relative story drifts for structural models as well as acceleration, displacement and weight limits for shaking table, to obtain the typical building response as soon as possible, balsa is selected as a material property, and additional masses are bonded to some floors. Finite element models of the building models are constituted in SAP2000 program. According to the main purposes of earthquake resistant design, three different earthquake records are used to simulate the weak, medium and strong ground motions. The displacement and acceleration time-histories are obtained for all earthquake records at the top of building models. To validate the numerical results, shaking table tests are performed. The selected earthquake records are applied to first mode (lateral) direction, and the responses are recorded by sensitive accelerometers. Comparisons between the numerical and experimental results show that shaking table tests are enough to identify the structural response of wooden buildings. Considering 20%, 10% and 5% damping rations, differences are obtained within the range 4.03-26.16%, 3.91-65.51% and 6.31-66.49% for acceleration, velocity and displacements in Model-1, respectively. Also, these differences are obtained as 0.49-31.15%, 6.03-6.66% and 16.97-66.41% for Model-2, respectively. It is thought that these differences are caused by anisotropic structural characteristic of the material due to changes in directions parallel and perpendicular to fibers, and should be minimized using the model updating procedure.

The Post-occupancy Evaluation of Roofgarden at Hospital - A Case Study of Asan Medical Center - (병원 옥상정원의 이용후 평가 - 서울아산병원을 대상으로 -)

  • 김인혜;허근영;최아현;김유일
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.5
    • /
    • pp.58-72
    • /
    • 2003
  • Rooftop greenery has been used as a way to solve urban environmental problems by creating green space in densely populated cities. This study was carried out to suggest more effective designs for roof-garden at hospitals through a post-occupancy evaluation. The roofgarden of Asan Medical Center was evaluated with regards to setting, proximate environmental context, users, and design activity by a multi-method including plan investigations, observations, in-depth interviews and questionnaires. The results are summarized as follows; the users' main activities included resting, walking, and talking. A number of users were observed at shaded spaces sitting on such things as benches, pergolas, and shelters. The satisfaction of the users showed high satisfaction level except in the amount of shade, facilities, and shelter. The variables affecting a overall satisfaction were ‘accessibility’, ‘safety’, ‘quality of surroundings’, and ‘suitability for speculation’. By comparing the design concept with using pattern, designer's intention was not reflected sufficiently in several aspects such as ‘event deck for therapy programs’, ‘grove and path’, and ‘low planters’. This study suggests some design implications; it is necessary to furnish shaded sitting places for passive behaviors and pathways for walking or a light exercise. A wind-break wall with glass windows could widen the users' views in a limited space. Natural shade like tree shade or pergola are more desirable than artificial shades. As for the vertical location of the roofgarden, the middle floor could be better than top area for accessibility. Characteristics of building and users should be considered in detail to provide distinct spaces. Proper technical standards for the greening of artificial ground should be established.

A Study on the Curriculum and Computer Program Subjects in Department of Architecture-related (국내 건축분야 학과의 현황과 컴퓨터 과목에 대한 조사연구)

  • Nam, Yun-Cheol
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.2
    • /
    • pp.27-34
    • /
    • 2013
  • According to current digital and information society, architecture related departments in universities give and educate computer courses to train top-level human resources suiting the needs of the time. The aim of this study is to curriculum of architecture related departments and to use the references for curriculum organization by understanding computer courses for architecture related departments. The results are as follows: (1) There are 100 departments (28.2%) in the field of architecture and 130 departments including an academic system that is the most departments. Also, there are 86 departments (39.8%) in the field of architecture engineering and 117 departments including an academic system. There are 77 departments in the field of interior architecture, which contain 48 departments (62.3%) of two- or three-year bachelor course college. (2) Department in the field of architecture opens a program study course in the second year of the program that is the most courses had been opened. First, most departments selected an order of learning a structure/detail construction techniques of architecture and design skills such as a foundation system and expression of the structure by hand in the first grade and processing it using a computer in the second grade. (3) BIM was opened in only three departments of 31 departments surveyed and was opened in a senior class. The reasons of still lack of BIM are the compatibility deficit of partners such as building structure, building equipment, securing lecturer, and still the dominant point of CAD in the field. (4) Six departments of 31 departments surveyed did not open a program study course as a major. That is to say, it is learned in a basic course or basic liberal arts education requirements (information area) of each department, or in an own program of each department. (5) The program study is only a means to create architectural drawings in department of the field of architecture. Thus, we should remember not only the drawing through the program but also drawing up a floor plan after understanding of methods such as constructional methods, detail drawing, and expression.

A Mechanism to identify Indoor or Outdoor Location for Three Dimensional Geofence (3차원 지오펜스를 위한 실내외 위치 식별 메커니즘)

  • Eom, Young-Hyun;Choi, Young-Keun;Cho, Sungkuk;Jeon, Byungkook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.169-175
    • /
    • 2016
  • Geofence is a virtual perimeter for a real-world geographical area, which could be statically or dynamically established the specified area if necessary. Many geofencing applications incorporate 2D(two-dimensional) map such as the Google map, allowing administrators to define boundaries on top of a satellite view of a specific geographical area. But these applications do not provide 3D(three-dimensional) spatial information as well as 2D location information no matter where indoor or outdoor. Therefore we propose a mechanism to identify indoor or outdoor location for 3D geofence, and implement 3D geofence using smartphone. The proposed mechanism identifies the position information on 3D geofence regardless of indoor or outdoor, inter-floor with only GPS and WiFi. In the near future, 3D geofence as well as LBS are promising applications that become possible when IoT can become organized and connected by location.

Physical Environment Change and Occupancy Evaluation on Green-Remodeled University Dormitory (그린리모델링 기숙사의 물리적환경 변화와 거주자평가)

  • Choi, Yoon-Jung;Lee, Ho-Yeon;Lee, Hyun-Jung;Kim, Won-bae
    • Journal of the Korean housing association
    • /
    • v.28 no.1
    • /
    • pp.37-44
    • /
    • 2017
  • This study focuses on the university dormitory remodeled toward energy efficiency. The study has its purpose on deriving the aspects to be concerned for later green remodeling and enhancing the effects of green remodeling, by analyzing the changes of physical environment, changes of energy consumption amount, and needs of the residents. For this purpose, the study went through the review of project report from government office for green remodeling, field investigation of remodeling elements, and the occupancy evaluation by Focus Group Interview. FGI means interviewing small group of the residents who lived in the subjected dormitories both before and after the remodeling. As results, the elements of green remodeling in targeted dormitories were inner wall insulation, top-floor ceiling insulation, replacement of windows, installment of automatic entrance door and making transfer space connected the entrance door. As the parts of equipment system, EHP high-efficiency cooler, highly efficient radiator, upgraded LED lightings with covers, and automatic control system (only one building) were installed. Energy consumption was declined, and the satisfaction of residents was increased after the green remodeling. However, the aspects which were not improved or unsatisfying also have been detected. Therefore, the study states the suggestions each for the administrators, designers and planners, and residents to concern for enhancing the effects of green remodeling or construction of new dormitories.

Parametric optimization of an inerter-based vibration absorber for wind-induced vibration mitigation of a tall building

  • Wang, Qinhua;Qiao, Haoshuai;Li, Wenji;You, Yugen;Fan, Zhun;Tiwari, Nayandeep
    • Wind and Structures
    • /
    • v.31 no.3
    • /
    • pp.241-253
    • /
    • 2020
  • The inerter-based vibration absorber (IVA) is an enhanced variation of Tuned Mass Damper (TMD). The parametric optimization of absorbers in the previous research mainly considered only two decision variables, namely frequency ratio and damping ratio, and aimed to minimize peak displacement and acceleration individually under the excitation of the across-wind load. This paper extends these efforts by minimizing two conflicting objectives simultaneously, i.e., the extreme displacement and acceleration at the top floor, under the constraint of the physical mass. Six decision variables are optimized by adopting a constrained multi-objective evolutionary algorithm (CMOEA), i.e., NSGA-II, under fluctuating across- and along-wind loads, respectively. After obtaining a set of optimal individuals, a decision-making approach is employed to select one solution which corresponds to a Tuned Mass Damper Inerter/Tuned Inerter Damper (TMDI/TID). The optimization procedure is applied to parametric optimization of TMDI/TID installed in a 340-meter-high building under wind loads. The case study indicates that the optimally-designed TID outperforms TMDI and TMD in terms of wind-induced vibration mitigation under different wind directions, and the better results are obtained by the CMOEA than those optimized by other formulae. The optimal TID is proven to be robust against variations in the mass and damping of the host structure, and mitigation effects on acceleration responses are observed to be better than displacement control under different wind directions.