• 제목/요약/키워드: Top floor

검색결과 238건 처리시간 0.021초

The Hedonic Method in Evaluating Apartment Price: A Case of Ho Chi Minh City, Vietnam

  • NGUYEN, Ha Minh;PHAN, Hung Quoc;TRAN, Tri Van;TRAN, Thang Kiem Viet
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권6호
    • /
    • pp.517-524
    • /
    • 2020
  • The study examines factors affecting apartment prices in the real estate market of Ho Chi Minh City, Vietnam. The study uses primary data based on surveys of customers who have traded successfully, and collects transaction data from real estate trading companies that are the top investors in Ho Chi Minh City real estate market. The collected data include 384 observations in a total of 24 districts, detailing that each district surveyed on a minimum of four projects, each project carried out a survey on a minimum of four apartments. The survey collected 339 valid questionnaires for analysis and model testing. This study employs multivariate regression with the data of 339 observations. The research results reveal that five significant factors affect positively the price of apartments in Ho Chi Minh City - apartment area, toilet and bedroom, apartment floor, reference price, and apartment interior. Besides, there are three significant factors affecting negatively the price of apartments - next price trend, distance to city center, and potential building. From the results, the research proposes solutions in the pricing of apartments in the real estate market in Ho Chi Minh City - better information system, a real estate transaction index, and stricter management of small brokerage activities.

아웃리거 댐퍼시스템의 감쇠와 강성 변화에 따른 지진응답제어 성능평가 (Performance Evaluation of Seismic Response Control of Outrigger Damper System with Variation of Damping and Stiffness)

  • 이령경;김수진;이영락;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제16권3호
    • /
    • pp.107-115
    • /
    • 2016
  • In recent years, an outrigger damper system has been proposed to reduce dynamic responses of tall buildings. However, a study on outrigger damper system is still in its early stages. In this study, time history analysis was performed to investigate the dynamic response control performance of outrigger damper. To do this, a actual scale 3-dimensional tall building model with outrigger damper system has been developed. El Centro earthquake was applied as an earthquake excitation. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. Analysis results, on the top floor displacement response to the earthquake load, was greatly effected by damping value. And acceleration response greatly was effected by stiffness value of damper system. Therefore, it is necessary to select that proper stiffness and damping values of the outrigger damper system.

공연장의 소방시설 설치기준의 개선방안에 관한 연구 (A Study on the Fire Protection System in the Stage)

  • 장상태;이영재
    • 한국화재소방학회논문지
    • /
    • 제13권4호
    • /
    • pp.13-19
    • /
    • 1999
  • 건축물의 면적과 용도에 따른 형식적이고 획일적인 소방시설의 설치기준에 대하여 국내공연장들의 소방 시설 실태를 근거하여 건축물의 특이성에 적합한 방재시설에 대한 보완방법을 신축하고 있는 1900석 규모의 공연장을 사례로 하여 - 최 상층부 소방시설의 방수압력을 고려한 1차 수원의 100%와 예비 가압송수장치 -무대부 개방형 스프링쿨러에서의 측벽형 헤드 보완과 대구경 살수 헤드 -특수감지기의 설치규정 세분화와 첨단 감지기 도입 -무대부와 객석부의 방화구획용 방화막의 설치와 설치에 따른 설치방법 등에 대해 제시하였다.

  • PDF

인접한 쌍둥이 구조물의 진동제어를 위한 점성 감쇠기의 다목적 최적 분포 (Multi-Objective Optimal Distributions of Viscous Dampers for Vibration Control of Adjacent Twin Structures)

  • 류선호;옥승용
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.61-67
    • /
    • 2018
  • This study proposes a new vibration control approach for adjacent twin structures, which is termed as viscous damper asymmetric coupling system in this paper. The proposed system takes a concept that the diagonal bracing viscous dampers are asymmetrically distributed in two buildings to break the behavior symmetry of the twin buildings and then the coupling viscous damper is additionally installed at the top floor of the two buildings to couple both buildings and interactively transfer the asymmetric behavior-caused damping forces into both buildings. These asymmetric damping distributions and interacting damping forces of the connection damper efficiently suppress the overall vibration of the damper-coupled adjacent twin buildings efficiently. Genetic algorithm (GA) based multi-objective optimization technique is adopted for optimal design of the proposed system. In the numerical example of adjacent twin 10-story building structures, the conventional control approach, that is, uniform damping distribution system (UDS) is also taken into account for comparison purpose. The optimization results verify that the proposed system either can improve the control performance over the UDS with the same damping capacity, or can save the damping capacity significantly while maintaining the similar level of control performance to the UDS.

국내 종합병원 진단검사의학과의 면적산정 방법에 대한 연구 - 검사실 사례조사를 중심으로 (A Study on the Space Area Guideline of Clinical Laboratory in Korea - Focused on Laboratory Case Studies)

  • 김영애;송상훈
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권2호
    • /
    • pp.39-47
    • /
    • 2020
  • Purpose: Clinical laboratory of hospital has been demanded to extension or relocation regarding with the test number increase and analyzer development. Space area criteria per test numbers, lab functions, hospital bed and lab staffs are needed for draft space programing. So, the purpose of this study is to provide the space area guideline of clinical laboratory for space calculation in planning and design the spatial environment. Methods: Literature review has been used in checking the standards and guidelines. And questionnaire surveys to laboratory supervisors in hospitals have been conducted for the data collection. 60 answers have been analysed statistically by MS Excel program. Results: The result of this study can be summarized into three way calculations. The first one shows that the basic standard workspace and distance is applied in lab design. The second one shows that average space area criteria resulted from case studies is applied by 19㎡ per one staff, 0.9~1.0㎡ per one bed, and lastly linear length calculation of workbenches and analyzers on the bench top and floor mount, is multiplying it by the sum of the counter depth plus aisle width. Implications: In updating the space area calculation guidelines, it is necessary to cooperate with medical staffs and designers.

물체 운반을 위한 다수 로봇의 협조제어 (Cooperative Control of Mobile Robot for Carrying Object)

  • 정희인;호앙낫민;우창준;이장명
    • 로봇학회논문지
    • /
    • 제10권3호
    • /
    • pp.139-145
    • /
    • 2015
  • This paper proposed a method of cooperative control of three mobile robots for carrying an object placed on a floor together. Each robot moves to the object independently from its location to a pre-designated location for grasping the object stably. After grasping the common object, the coordination among the robots has been achieved by a master-slave mode. That is, a trajectory planning has been done for the master robot and the distances form the master robot to the two slave robots have been kept constant during the carrying operation. The localization for mobile robots has been implemented using the encoder data and inverse kinematics since the whole system does not have the slippage as much as a single mobile robot. Before the carrying operation, the lifting operations are implemented using the manipulators attached on the top of the mobile robots cooperatively. The real cooperative lifting and carrying operations are implanted to show the feasibility of the master-slave mode control based on the kinematics using the mobile manipulators developed for this research.

Mitigation of seismic collision between adjacent structures using roof water tanks

  • Mahmoud, Sayed
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.171-184
    • /
    • 2020
  • The potential of using the roof water tanks as a mitigation measure to minimize the required separation gap and induced pounding forces due to collisions is investigated. The investigation is carried out using nonlinear dynamic analysis for two adjacent 3-story buildings with different dynamic characteristics under two real earthquake motions. For such analysis, nonlinear viscoelastic model is used to simulate forces due to impact. The sloshing force due to water movement is modelled in terms of width of the water tank and the instantaneous wave heights at the end wall. The effect of roof water tanks on the story's responses, separation gap, and magnitude and number of induced pounding forces are investigated. The influence of structural stiffness and storey mass are investigated as well. It is found that pounding causes instantaneous acceleration pulses in the colliding buildings, but the existence of roof water tanks eliminates such acceleration pulses. At the same time the water tanks effectively reduce the number of collisions as well as the magnitude of the induced impact forces. Moreover, buildings without constructed water tanks require wider separation gap to prevent pounding as compared to those with water tanks attached to top floor under seismic excitations.

Seismic responses of base-isolated buildings: efficacy of equivalent linear modeling under near-fault earthquakes

  • Alhan, Cenk;Ozgur, Murat
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1439-1461
    • /
    • 2015
  • Design criteria, modeling rules, and analysis principles of seismic isolation systems have already found place in important building codes and standards such as the Uniform Building Code and ASCE/SEI 7-05. Although real behaviors of isolation systems composed of high damping or lead rubber bearings are nonlinear, equivalent linear models can be obtained using effective stiffness and damping which makes use of linear seismic analysis methods for seismic-isolated buildings possible. However, equivalent linear modeling and analysis may lead to errors in seismic response terms of multi-story buildings and thus need to be assessed comprehensively. This study investigates the accuracy of equivalent linear modeling via numerical experiments conducted on generic five-story three dimensional seismic-isolated buildings. A wide range of nonlinear isolation systems with different characteristics and their equivalent linear counterparts are subjected to historical earthquakes and isolation system displacements, top floor accelerations, story drifts, base shears, and torsional base moments are compared. Relations between the accuracy of the estimates of peak structural responses from equivalent linear models and typical characteristics of nonlinear isolation systems including effective period, rigid-body mode period, effective viscous damping ratio, and post-yield to pre-yield stiffness ratio are established. Influence of biaxial interaction and plan eccentricity are also examined.

아웃리거 댐퍼시스템의 고층건물 지진응답제어 성능 평가 (Evaluation of Vibration Control Performance of Outrigger Damper System for Tall Buildings Subjected to Seismic Load)

  • 윤성욱;이령경;김광일;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제16권1호
    • /
    • pp.95-104
    • /
    • 2016
  • Recently, the concept of damped outrigger system has been proposed for tall buildings. But, structural characteristics and design method of this system were not sufficiently investigated to date. In this study, the dynamic response control performance of outrigger damper has been analyzed. To this end, a simplified analysis model with outrigger damper system has been developed. Use the El Centro seismic(1940, NS) analysis was performed. Analysis results, on the top floor displacement response to the earthquake response, did not have a big effect. However, acceleration response control effect was found to be excellent. The increase of outrigger damper capacity usually results in the improved control performance. However, it is necessary to select that proper stiffness and damping values of the outrigger damper system because, the outrigger damper having large capacity is result in heavy financial burden.

위성의 전이궤도 열해석 (TRANSFER ORBIT THERMAL ANALYSIS FOR SATELLITE)

  • 전형열;김정훈;김성훈;양군호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.227-231
    • /
    • 2007
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication and ocean and meteorological observations. It will be launched by ARIANE 5. Ka-band components are installed on South panel, where single solar array wing is mounted. Radiators, embedded heat pipes, external heat pipe, insulation blankets and heaters are utilized for the thermal control of the satellite. The Ka-band payload section is divided several areas based on unit operating temperature in order to optimize radiator area and maximize heat rejection capability. Other equipment for sensors and bus are installed on North panel. The ocean and meteorological sensors are installed on optical benches on the top floor to decouple thermally from the satellite. During the transfer orbit operation, satellite will be under severe thermal environments due to low dissipation of components, satellite attitudes and LAE(Liquid Apogee Engine) firing. This paper presents temperature and heater power prediction and validation of thermal control design during transfer orbit operation.

  • PDF