• 제목/요약/키워드: Top Oil Temperature

검색결과 47건 처리시간 0.03초

어선기관의 연료유 절감에 관한 연구 (A Study on The Reduction of Fuel Oil Consumption for Fishing Boat Engine)

  • 이창호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.12-19
    • /
    • 1981
  • As the fuel oil cost covers from 45% to 60% of the total expenditure for fishing boat operation, the energy saving is now an urgent problem to be taken a countermeasure for engineers, manufacturers or specialists engaging in this field. Undertaking a second-hand engine of the trainging ship, the author made several reconstructions to restore its performances. By inserting foot linears of connecting rods the compression ratio was increased and by adjusting both the fuel injection timing and the cooling water outlet temperature, its thermal efficiency was improved. The results of the experimental operation were summarized as follows. 1. By raising the piston top position 0.75mm more than the value of the operating manual, the compression pressure increased 1.3 kg/$cm^2$ and the maximum pressure did 3.4 kg/$cm^2$ at 75% load. 2. At 75% load, the difference of the maximum pressure between each cylinder was decreased from 2.4 kg/$cm^2$ to 1.8 kg/$cm^2$. 3. The fuel consumption was decreased about 8 g/ps.h at 75% load, and about 5.3 g/ps.h at 85% load. 4. The brake thermal efficiency was improved about 1.5% at 75% load and 0.9% at 85% load.

  • PDF

수용가 전력 소비 패턴을 고려한 배전용 변압기 과부하 판정기준 (Overload Criteria of Distribution Transformers Considering the Electric Consumption Patterns of Customers)

  • 윤상윤;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권9호
    • /
    • pp.513-520
    • /
    • 2004
  • In the paper, we summarize the result of the experimental research for the overload criteria of domestic distribution transformers considering the electric consumption patterns of customers. For the basic characteristic data of distribution transformer overload, the actual experiments are accomplished. The field data of loads are surveyed from sample transformers for analyzing the consumption pattern of customer load. The load data acquisition devices are equipped, and the algorithm of load pattern classification is applied. In addition to this efforts, various load pattern data. in past are gathered. Then the representative load pattern of each customer type in domestic is extracted. The final results of overload criterions are presented as tabular form through the results of experiments and survey are combined. The field test of the experiment results is peformed using the special manufactured transformers, which can measure both the load and top-oil temperature of transformer. Through this, we verify that the results of field test are similar to the laboratory one and the Proposed overload criteria can be effectively applied to the real system.

높은 Prandtl 수 유체에서 축회전이 열모세관 유동의 진동에 미치는 영향 (Effect of axial rotation on oscillatory thermocapillary flow in half-zone of high Prandtl number fluid)

  • 전승원;이규정
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2248-2253
    • /
    • 2008
  • A numerical study on oscillatory thermocapillary flow in half-zone has performed to understand the effect of axial rotation. 2d unsteady code is developed to observe the onset of oscillation. 2cs Silicone oil with Prandtl number of 26.5 is used as a working fluid. The critical temperature difference at onset of oscillation is investigated under the different aspect ratios and rotation modes. It is shown that the onset of oscillation is delayed when aspect ratio reduces and rotating speed increases. The oscillatory flow is strongly reduced under top rotation and co-rotation modes, while it is augmented under bottom rotation and counter-rotation modes. It is thought that interaction between return flow and bottom wall is important to explain the oscillatory flow.

  • PDF

변압기를 모델링한 두 개의 동심 원형 실린더 내에서 난류 자연대류의 수치해석 (Numerical analysis of turbulent natural convection in a cylindrical transformer enclosure)

  • 오건제;하수석
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.157-166
    • /
    • 1999
  • Numerical calculations of turbulent natural convection in an enclosure of the 20 kYA oil-immersed transformer model are presented. The transformer is modelled as two concentric cylinders with different heights and diameters. The thermal boundary layers are well represented in the temperature distributions along the wall of the transformer model. The flow stratification between the hot and cold walls can not be seen in the transformer model. The turbulence eddy viscosity has its maximum at the center of the core and its maximum values at the top of the core are larger than those at the bottom of the core.

  • PDF

무선통신을 이용한 배전용 변압기 모니터링 및 진단 장치 개발에 관한 연구 (The Study on the Monitoring and Diagnostic System for Distribution Transformer Using Wireless Communication)

  • 문종필;김재철;최준호;김언석;윤용한;민경래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.214-216
    • /
    • 2001
  • In this paper, we developed the on-line Diagnostic & Monitoring system of distribution transformers using wireless communication. The Diagnostic system consists of the top oil temperature sensing, ambient temperature sensing. load current sensing, acoustic emission peak-value sensing, acoustic emission pulse counter and wireless communication part. The Monitoring system consists of the communication setting, online monitoring and database construction part. The Diagnostic system send the date acquired from the some sensors of the distribution transformers to the host PC. The Monitoring program of the host PC store the data to database. And the Monitoring system estimates the loss of life from the DB. Thus it could be managed the career and the functional lifetime of the transformer more efficiently than existing methodologies.

  • PDF

배전용 변압기 감시를 위한 온라인 데이터 취득 장치 개발 (A Study of Developing the On-line Data Aquisition System for Monitoring the Distribution Transformer)

  • 문종필;김재철;최준호;김언석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.464-466
    • /
    • 2001
  • In this paper, we developed the on-line Data Aquisition System(DAS) of distribution transformers using the hardware and monitoring program. The DAS consists of the top oil temperature sensing part, ambient temperature sensing part, load current sensing part, acoustic emission peak-value sensing part, acoustic emission pulse counter part, micro-processor part and wireless communication part. The Monitoring System consists of the communication setting, online monitoring and database construction part. The DAS send the data acquired from the some sensors of the distribution transformers to the host PC. The monitoring program of the host PC stores the data to database. And the monitoring system estimates the loss of life time for distribution transformer from the DB. Thus, it could be managed the career and the functional lifetime of the transformer more efficiently than existing methodologies.

  • PDF

STUDY OF CORRELATION BETWEEN WETTED FUEL FOOTPRINTS ON COMBUSTION CHAMBER WALLS AND UBHC IN ENGINE START PROCESSES

  • KIM H.;YOON S.;LAI M.-C.
    • International Journal of Automotive Technology
    • /
    • 제6권5호
    • /
    • pp.437-444
    • /
    • 2005
  • Unburned hydrocarbon (UBHC) emissions from gasoline engines remain a primary engineering research and development concern due to stricter emission regulations. Gasoline engines produce more UBHC emissions during cold start and warm-up than during any other stage of operation, because of insufficient fuel-air mixing, particularly in view of the additional fuel enrichment used for early starting. Impingement of fuel droplets on the cylinder wall is a major source of UBHC and a concern for oil dilution. This paper describes an experimental study that was carried out to investigate the distribution and 'footprint' of fuel droplets impinging on the cylinder wall during the intake stroke under engine starting conditions. Injectors having different targeting and atomization characteristics were used in a 4-Valve engine with optical access to the intake port and combustion chamber. The spray and targeting performance were characterized using high-speed visualization and Phase Doppler Interferometry techniques. The fuel droplets impinging on the port, cylinder wall and piston top were characterized using a color imaging technique during simulated engine start-up from room temperature. Highly absorbent filter paper was placed around the circumference of the cylinder liner and on the piston top to collect fuel droplets during the intake strokes. A small amount of colored dye, which dissolves completely in gasoline, was used as the tracer. Color density on the paper, which is correlated with the amount of fuel deposited and its distribution on the cylinder wall, was measured using image analysis. The results show that by comparing the locations of the wetted footprints and their color intensities, the influence of fuel injection and engine conditions can be qualitatively and quantitatively examined. Fast FID measurements of UBHC were also performed on the engine for correlation to the mixture formation results.

에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율 (Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain)

  • 성순경
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.

태양열 이용을 위한 직접접촉식 액-액 열교환기 특성 (Characteristics of Liquid-Liquid Direct Contact Heat Exchanger for a Solar System)

  • 강인석;김종보;강용혁;곽희열
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3276-3286
    • /
    • 1994
  • In most direct contact liquid-liquid heat exchangers, oil or hydrocarbon with a density less than water is normally used as dispersed working fluid. The main difficulty that arises with this arrangement lies in the control of the interface at the top of the column. When it is connected with a solar collector which uses water as its working fluid, the main difficulties arise from the fact that the water can be frozen during winter time. In order to solve these problems and to demonstrate the technical feasibility of a direct contact liquid-liquid heat exchanger, liquids heavier than water with low freezing temperature has been utilized as dispersed phase liquids in a small laboratory scale model made of pyrex glass. In the present investigation, dimethyl phthalate(C/sub 6/H/sub 4/)COOCH/sub 3/)/sub 2/) and diethyl phthalate (C/sub 6/H/sub 4/(CO/sub 2/C/sub 2/H/sub 5/)/sub 2/) are utilized as heavy dispersed phase working fluids. The results of the present investigation the technical in the utilization of heavier dispersed working liquid in the spray-column liquid-liquid heat exchanger for a solar system. The overall average temperature difference along the column is found to be almost half of the initial temperature difference between the dispersed and the continuous phase. Despite the fact that the two phthalates tested in the experiment differ significantly in some of their physical properties, the volumetric heat transfer coefficients in terms of dispersed fluid superficial velocities were found to be similar for both phthalates tested.

자동변속기 윤활용 기어펌프의 가속 수명시험 설계에 관한 연구 (Study on Accelerated Life Test Design for a Gear Type Lubrication Pump for Automatic Transmission)

  • 박종원;정동수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제12권3호
    • /
    • pp.201-213
    • /
    • 2012
  • A gear type lubrication pump is an essential component of the powertrain and has a major role for supplying oil to the gears and bearings in automatic transmission with a hydraulic clutch. Therefore, the durability test code design of lubrication pump is very important to ensure the reliability of the entire transmission and the vehicle. In this study, the design process for the life testing of lubrication pump has been generalized by four steps. The four design steps of the life testing of lubrication pump consist of the configuration of load spectrum, rain flow counting and analysis of load level, the equivalent damage assessment and test code generation. In fact, the load spectrum should be obtained from the field operating condition but that kind of data is the top secret of manufacturers. This is not open to the public in general. So we could use the artificially simulated load spectrum instead of field obtained one and focused on the development of the general process for designing the life test of a gear type lubrication pump. Reliability goals for lubrication pump, pressure, torque, temperature and load spectrum, if present, as appropriate for the given test conditions, accelerated life testing for the lubrication pump can be designed by the developed design steps.