오일유막의 연료 흡수 및 방출에 관한 연구 (Modeling of Absorption/Desorption of Fuel in Oil film on the Cylinder Liner in SI Engines)

  • 유상석;민경덕
    • 한국자동차공학회논문집
    • /
    • 제7권9호
    • /
    • pp.165-171
    • /
    • 1999
  • An oil layer fuel absorption /desorption modeling was developed. Multi-component fuel model has showed more reasonable condition than single component model. Henry's constant which is related to solubility is the most important variable in the oil layer absorption/desorption mechanism. The oil segments close to the top of the cylinder liner have more significant contribution to the fuel absorption and desorption process than other oil segments. At the warmed-up condition, the effect of the engine speed on the precent fuel absorbed/desorbed is minimal. But at low il film temperature, percent of fuel abosrbed/desorbed is decreased with increasing the engine speed because of low value of molecular diffusion coefficient of fuel. The amount of fuel trapped in the piston crevice is from 2 to 2.3 times larger than that of fuel in the oil fim. However, fuel form oil film slowly desorbs into the combustion chamber compared with fuel from the piston crevices when the engines is cold.

  • PDF

LPG 액정분사 방식의 대형 엔진용 피스톤의 온도분포와 열응력 해석 (Temperature Distribution and Thermal Stress Analyses of a Large LPLi Engine Piston)

  • 임문혁;손재율;이부윤
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.538-550
    • /
    • 2004
  • The convection heat transfer coefficients on the top surface of a large liquid petroleum liquid injection(LPLi) engine piston with the oil gallery are analyzed by solving an inverse thermal conduction problem. The heat transfer coefficients are numerically found so that the difference between analyzed temperatures from the finite element method and measured temperatures is minimized. Using the resulting heat transfer coefficients as the boundary condition, temperature of a large LPLi engine piston is analyzed. With varying cooling water temperature, temperature, stress, and thermal expansion of the piston are analyzed and evaluated.

변압기의 3차원 온도분포 해석 (3-D Analysis of Temperature Distribution in Transformers)

  • 오연호;송기동;선종호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권9호
    • /
    • pp.434-441
    • /
    • 2003
  • This paper deals with the temperature characteristics according to the cooling medium and the duct size in model transformers. For the analysis and the temperature-rise tests, two 400kVA model transformers have been manufactured. One has been filled with the alpha oil as the cooling medium and constructed the duct sizes of $3\textrm{mm}$ and $5\textrm{mm}$ in the low-voltage and high-voltage windings respectively. The other has been filled the beta oil and the duct sizes were $4\textrm{mm}$ and $6\textrm{mm}$. The temperature-rise tests have been performed by the back-to-back method and the load factor has been controlled the range of 90%∼130%. The temperature values have been measured by the thermocouple and from the sixteen points in each transformer. A commercial CFD program "FLUENT" has been used for the analysis of temperature distribution. The geometry of transformer has been modeled to 3-dimensional by using the hybrid calculation mesh including the radiator. And also, the natural convection velocity has been measured at the oil top position, and compared with the calculated results.

에어-오일 냉각방식에 의한 고경도재료의 선삭 (Turning of Hardened Materials Using the Air-oil Cooling System)

  • 정보구;고태조;김희술
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.73-81
    • /
    • 1997
  • The hard turning process defined as a single point turning of materials harder than $H_{R}$C 58 differs from conventional turning because of hardness of the work materials and cutting toos needed in the process. In hard turning, tool life is very short, of the order of a few minutes, during which the cutting tool is subjected to the extremes of stress and temperature. In this regard, it is well known that CBN tool is proper for this process in spite of expensive cost. In this research, we studied the feasibility of the use of the low cost cutting tool such as a aTiN coated tool. To this end, a new cooling system was designed with an air-oil method for reducing tool temperature, which is based on the principle of air vortex flow. That is, the outlet temperature of the air becomes aver 20 .deg. C lower than atmosphere temperature by entering pressurized air of 5kgf/c $m^{2}$ into the inlet. This cooled air ejected to the top of the cutting tool lowered tool temperature, which reduced the wear of a TiN coated tool by the 30% of CBN tool life with respect to the same cutting length.h.

  • PDF

냉동유가 수평 마이크로 핀관내 R-134a의 증발열전달에 미치는 영향 (Influence of Refrigeration Oil on Evaporation Heat Transfer of R-134a in a Horizontal Micro-Fin Tube)

  • 배상철;강태욱;김정훈;정찬영;김종수
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.140-150
    • /
    • 1996
  • CFC-12, which has been used most widely in automobile air conditioners and household refrigerators is scheduled to be phased out soon because of its high ozone depletion potential. Now HFC-134a is suggested as an alternative refrigerant for CFC-12. In this Study, we intended to investigate how PAG oil influence evaporation heat transfer and flow pattern, using R-134a and PAG oil influences evaporation heat transfer and flow pattern, using R-134a and PAG oil in the horizontal miro-fin evaporation tube. Experiments were conducted under the flowing est conditions : mass velocity 86-250kg/$m^2$s, heat flux 5-30 ㎾/$m^2$, oil concentration 0-21 wt.% and saturation temperature 5$^{\circ}C$. Local evaporation heat transfer coefficients were found to be higher at the top, side and bottom of the tube in this order. Average heat transfer coefficients turned out to increase with oil concentration increment up to 3 wt.% oil concentration, whereas heat transfer coefficients gradually decreased over 3 wt.% oil concentration, because of oil-rich liquid film was formed on the heat transfer surface. Flow patterns were rapidly transitioned to annular regimes up to 3 wt.% oil concentration. In case of pure refrigerant, measured heat transfer coefficients in the experiments were similar to those of Kandlikar's correlation.

  • PDF

배전용변압기의 부하운전에 의한 온도 및 유전특성 분석 (Temperature Rise and Dielectric Characteristics of Distribution Transformers with Over-Loading Operation)

  • 김병숙;이병성;송일근;한병성;정종만
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.104-110
    • /
    • 2007
  • 본 논문은 권선내부에 온도계가 설치된 지상변압기를 제작하여 부하운전에 따른 배전용 변압기의 온도상승 특성과 절연유의 유전특성 변화를 관찰하였다. 관찰결과 배전용변압기의 경우 과열점은 세 권선 중 두개의 권선이 접하고 권선의 약 2/3 높이에 위치하고 있으며, 과열점과 절연유 상부 간에 약 $17[^{\circ}C]$의 일정한 온도차를 확인할 수 있었다. 또한 절연유의 정전용량특성은 온도와 선형적인 관계로 감소하는 특성을 보이며, 그 기울기는 열화율과 무관하게 -0.0106의 일정한 값을 관찰할 수 있었다. 이 결과는 수명손실의 정확한 계산과 열화진단을 위한 기구로 활용할 수 있을 것이다.

가스 포일 스러스트 베어링의 하중지지 성능 및 구동 토크에 관한 실험적 연구 (Experimental Study on the Load Carrying Performance and Driving Torque of Gas Foil Thrust Bearings)

  • 김태호;이태원;박문성;박정민;김진성;정진희
    • Tribology and Lubricants
    • /
    • 제31권4호
    • /
    • pp.141-147
    • /
    • 2015
  • Gas foil thrust bearings (GFTBs) have attractive advantages over rolling element bearings and oil film thrust bearings, such as oil-free operation, high speed stability, and high-temperature operation. However, GFTBs have lower load carrying capacity than the other two types of bearings owing to the inherent low gas viscosity. The load carrying capacity of GFTBs depends mainly on the compliance of the foil structure and the formed hydrodynamic wedge, where the gas pressure field is generated between the top foil and the thrust runner. The load carrying capacity of the GFTBs is very important for the suitable design of oil-free turbomachinery with high performance. The aim of the present study is to identify the characteristics of the load carrying performance of GFTBs. A new test rig for the experimental measurements is designed to provide static loads up to 800 N using a pneumatic cylinder. The maximum operating speed of the driving motor is 30,000 rpm. A series of experimental tests—lift-off test, static load performance test, and maximum load capacity test—estimate the performance of a six-pad GFTB, in terms of the static load, driving torque, and temperature. The maximum load capacity is determined by increasing the static load until the driving torque rises suddenly with a sharp peak. The test results show that the torque and temperature increase linearly with the static load. The estimated maximum load capacity per unit area is approximately 80.5 kPa at a rotor speed of 25,000 rpm. The test results can be used as a design guideline for GFTBs for realizing oil-free turbomachinery.

해양에서 유출된 기름의 해변 토양 침투거동에 미치는 영향인자 규명 실험 (Laboratory Study for the Identification of Parameters affecting the Penetration Behavior of Spilled crude oil in a Coastal Sandy Beach)

  • Cheong Jo, Cheong
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제8권1호
    • /
    • pp.81-86
    • /
    • 2003
  • 기름의 침투거동에 관한 정보는 처리대책의 수립 및 생물학적 영향을 최소화 하기 위한 중요한 단서가 된다. 본 연구에서는 사질지형의 조간대 모형을 이용하여 유출된 기름의 토양침투 거동을 파악하고 침투에 미치는 주된 영향인자를 규명하는 것을 목적으로 하여 연구를 수행하였다. 해수와 유출된 원유의 연안 해변 토양 침투거동은 전혀 달랐다. 해수는 파도와 조석의 물리적 작용에 의해서 토양 중으로 침투를 하였으나, 유출된 원유는 파도에 의해서는 침투되지 않고 조석작용에 의해서만 토양 중으로 침투하는 것을 알 수 있었다. 그리고 평방미터당 1 L의 유출유가 표착하였을 경우 약 70%이상의 유분이 토양 표층 2 cm의 부분에 집중되는 침투경향을 나타내었다. 그리고, 유출된 기름의 토양침투에는 온도의 변화에 의존하는 기름의 점도가 강한 영향을 미치는 것을 알 수 있었다.

해양에서 유출된 C중유의 토양 침투 거동 (Penetration Behavior of Spilled Fuel Oil C into Coastal Sandy Beach)

  • 정정조
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제6권3호
    • /
    • pp.37-44
    • /
    • 2003
  • 해상에서 유출된 기름의 조간대 토양 침투에 관한 정보는 유출된 기름의 생태계 피해와 생태계 피해를 최소화하기 위한 처리대책의 수립에 있어서 중요한 단서가 된다. 본 연구에서는 사질지형의 조간대 모형을 이용하여 파도와 조석에 의한 유출된 기름의 토양 침투 거동을 파악하고, 침투에 미치는 주된 영향인자를 규명하는 것을 목적으로 하여 연구를 수행하였다. 해수와 유출된 C중유의 연안 해변 토양 침투는 전혀 다른 거동을 보이는 것을 알 수 있었다. 해수는 파도와 조석의 물리적 작용에 의해서 토양 중으로 침투를 하였으나, 유출된 C중유는 파도에 의해서는 침투되지 않고 조석작용에 의해서만 토양 중으로 침투하는 것을 알 수 있었다. 그리고 평방미터당 1 L의 유출유가 표착하였을 경우 약 80%이상의 유분이 토양 표층 2 cm의 부분에 집중되는 침투경향을 나타내었다. 그리고 유출된 기름의 토양침투에는 온도의 변화에 의존하는 기름의 점도가 강한 영향을 미치는 것을 알 수 있었다.

  • PDF

가솔린기관의 회전수 변화에 따른 실린더 벽면온도 변화 및 기관성능에 관한 연구 (An Study on the Cylinder Wall Temperature and Performance of Gasoline Engine according to Engine Speed)

  • 권기린;오영옥;강남훈
    • 동력기계공학회지
    • /
    • 제6권1호
    • /
    • pp.20-26
    • /
    • 2002
  • The purpose of this study is preventing the stick, scuffing, scratch between piston and cylinder in advance, and obtaining data for duration test in actual engine operation. The temperature gradient in cylinder bore according to coolant temperature were measured using $1.5{\ell}$ class diesel engine. 20 thermocouples were installed 2mm deep inside from cylinder wall near top ring of piston in cylinder block, at which points major thermal loads exist. It is suggested as proper measurement points for engine design by industrial engineers. Under full load and $70^{\circ}$, $80^{\circ}C$ and $90^{\circ}C$ coolant temperature conditions, the temperature in cylinder block and engine oil increased gradually according to the increase of coolant temperature, the siamese side temperature of top dead center is $142^{\circ}C$ in peripheral distribution, that is about $20^{\circ}C$ higher than that at thrust, anti-thrust, and rear side temperature, respectively. The maximum pressure of combustion gas in $70^{\circ}C$ coolant temperature is about 2 bar lower than those of $80^{\circ}C$ and $90^{\circ}C$ coolant temperature. The engine torque in $80^{\circ}C$, $90^{\circ}C$ coolant temperature condition is about 4.9Nm higher than that of $70^{\circ}C$ coolant temperature.

  • PDF