• Title/Summary/Keyword: Tooth shape

Search Result 343, Processing Time 0.028 seconds

Visualization of Tooth for Non-Destructive Evaluation from CT Images

  • Gao, Hui;Chae, Oksam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.207-213
    • /
    • 2009
  • This paper reports an effort to develop 3D tooth visualization system from CT sequence images as a part of the non-destructive evaluation suitable for the simulation of endodontics, orthodontics and other dental treatments. We focus on the segmentation and visualization for the individual tooth. In dental CT images teeth are touching the adjacent teeth or surrounded by the alveolar bones with similar intensity. We propose an improved level set method with shape prior to separate a tooth from other teeth as well as the alveolar bones. Reconstructed 3D model of individual tooth based on the segmentation results indicates that our technique is a very conducive tool for tooth visualization, evaluation and diagnosis. Some comparative visualization results validate the non-destructive function of our method.

Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique (프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발)

  • Ullah, Furqan;Lee, Gunn-Soo;Park, Kang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

Effect of Tooth Shape and Unbalanced M.M.F on Static Thrust Force Characteristics of Linear Pulse Motor (리니어 펄스 모터에서 치 형상과 기자력 불평형이 정추력 특성에 미치는 영향)

  • Lee, Dong-Ju;Lee, Eun-Ung;Kim, Seong-Heon;Kim, Seong-Jong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.131-137
    • /
    • 2000
  • 2 phase 8 pole HB-type(flat-type) Linear Pulse Motor can be used as the high precision position actuator because of its many advantages (simple control circuit, high stiffness characteristics, etc). Also, using the microstep drive, its noise and vibration can be reduced considerably and positional resolution may be increased further. But, $20^{\circ}$tapered tooth shape to reduce the normal force have an much effect on the static thrust force characteristics. And, because of hybrid-type LPM, interaction between the permanent magnet and the excitation current have an effect on the various characteristics of LPM. Hence, in this paper, the effect of tooth shape on static thrust force characteristics was analyzed using the air gap permeance by finite element method. For analyzing the effect of unbalance between the m.m.f of permanent magnet and the m.m.f of excitation current, unbalanced m.m.f coefficient $\sigma$ were introduced with the permenace matrix and switching matrix.

  • PDF

A Mechanistic Model for the Prediction of Cutting Forces in Band Sawing (톱기계에서 절삭력 예측을 위한 역학모델)

  • Jung, Hoon;Ko, Tae-Jo;Kim, Hee-Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.145-152
    • /
    • 1998
  • In this research, in order to predict the cutting force using a mechanistic model, specific cutting force was firstly obtained through the cutting experiments. Band sawing process is similar to a milling, that is multi-point cutting. Therefore it is not easy matter to evaluate specific cutting force. Thus, the thickness of workpiec was made smaller than one pitch of the saw in terms of fly cutting in the face milling process. Then the cutting force was predicted by analyzing the geometric shape of a saw tooth The tooth shape used in the research was raker set style that was generally used in band sawing. And a set of teeth is comprised of three teeth, those are ranked as left, straight and right. The mechanistic model was developed in this study considered those shapes of each tooth. From the validation experiments, the predicted cutting forces coincided well with the measured ones. Therefore the predicted cutting forces can be used for the adaptive control of saw engaging feed rate in the band sawing.

  • PDF

A Study on Tooth Profile Modification of Planetary Reducer for 120kW Class Monorail (120kW급 모노레일용 유성기어감속기의 치형수정에 관한 연구)

  • Jeong, Yeong-Sik;Kim, Nam-Kyung;Xu, Zhezhu;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.195-200
    • /
    • 2012
  • In this study, parameters and requirements of an 120kW class monorail planetary gearbox was analysed and the adaptive planetary gearbox design was selected. The specification of the sun gear, planetary gear and carrier was set and the profile & lead was optimized. The mechanical efficiency of the optimized one and the original one was observed. Dynamo-tester system was used to observe the mechanical efficiency of the planetary gearbox. A dynamo unit was connected with the planetary gearbox which straightened through the motor by a coupling. The standard tooth shape planetary gearbox and modified tooth shape planetary gearbox were used as test pieces and the rotation speed was set from 600 to 6000rpm with 600rpm, 2.5min one step. In order to check the mechanical efficiency of the planetary gearbox, the tests were done as follows. 1) The power loss between driving motor and dynamo tester. 2) Temperature variation by different rotation speeds. 3) Noise variation by different rotation speeds.

Types of Mentum Deformity for Chironomus riparius Exposure to DEHP (DEHP에 노출된 Chironomus riparius의 하순기절에 나타난 기형 유형들)

  • Kwak, Inn-Sil;Jeong, Gyeong-Suk
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Induction of morphological deformities in Chironomus riparius larvae was assessed after exposure to 0.3, 1, 10 and 30 ${\mu}g\;L^{-1}$ potential endocrine disruption chemicals, Diethylhexyl phtalate (DEHP). We observed and subdivide types of mentum deformities and counted the incidence of mentum deformities. The mortality was not increased according to concentrations of DEHP, while was depend on the exposed days. The incidence of mentum deformities for MLT (median lateral teeth), LT (lateral teeth), and MIX (MLT+LT) of the mentum morphological structure showed MLT (2.8$\sim$11.4%)>LT (2.8$\sim$2.9%)>MIX (2.8$\sim$3.0%). The type of mentum deformities on C. riparius was classified six groups following exposure to DEHP. The incidence rate was occupied following to tooth addition (4.3%), tooth split (2.8%), tooth deletion (2.4%), tooth fusion (1.4%), $K"{o}hn$ gap (0.5%) and abnormal shape (0.5%). Especially tooth split and tooth fusion were observed in DEHP treated conditions.

A Morphometric Study of Primary Anterior Zirconia Crowns in Korean Tooth Models (한국 유치 모델에서 유전치 지르코니아 크라운의 형태계측학적 연구)

  • Park, Jungha;Lee, Sangho;Lee, Nanyoung;Jih, Myoungkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-56
    • /
    • 2018
  • The purpose of this study was to provide clinical recommendations for restoration with selection of the most similar zirconia crown by 3-dimensional analysis of the shape of the maxillary primary central and lateral incisors in Korean individuals and prefabricated zirconia crowns. The average shape of the sound maxillary primary central and lateral incisors in 300 children was reproduced by 3-dimensional scanning. Zirconia crowns of 4 manufacturers (NuSmile $ZR^{(R)}$ Crown, Cheng $Crowns^{(R)}$, Kinder $Krowns^{(R)}$, and EZ $Pedo^{(R)}$ Crown) were scanned 3-dimensionally, and coordinates for comparison of the shape were measured to evaluate the similarity between the teeth and crowns. The most similar crowns were selected by comparing the mesiodistal length, crown height, crown shape ratio, distance between the same coordinates of a tooth and crown, the radius of curvature of the labial surface, and the volume. As a result of analysis, Cheng $Crowns^{(R)}$ size 3 and NuSmile $ZR^{(R)}$ Crown size 2 were the most similar crowns in the maxillary primary central and lateral incisors, respectively. Scanning the inner surface of the crowns and evaluating the amount of tooth reduction required suggested that an overall lesser amount of tooth reduction compared to that presented by the manufacturer's guidelines should be performed.

Antreior Single Tooth Restoration for Esthetics (전치부 단일 치아의 심미적수복에 관한 증례)

  • Jhang, Young Myung
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.7 no.1
    • /
    • pp.28-31
    • /
    • 1998
  • It is difficult to make an artificial central incisor similar to natural tooth. All ceramic porcelain of this patient is not esthetic, and there is gingival recession due to ill-fitted margin. She has class II division 1 occlusion, so upper central incisors is labioversed. Upper light central incisor is well-characterized but the yellowish brown color of dentin is appeared on the incisal third portion of the central incisor. At 1st trial, the shape and characterization of restoration is good but shade is little dark. At 2nd trial, the shape is better but patient complained on black triangle of mid interdental space, so mesiocervical portion of restoration is overcontoured to compromise the black triangle. Completed metal ceramic crown is in harmony with the adjacent central incisor in aspect of shape, shade, and characterization.

  • PDF

Tooth Profile Design of an Oval Gear According to the Curvature of the Pitch Curve (오벌기어의 피치곡선 곡률에 따른 치형 설계)

  • Lee, Sung-Chul
    • Tribology and Lubricants
    • /
    • v.28 no.1
    • /
    • pp.27-32
    • /
    • 2012
  • Oval gears are typical kinds of non-circular gears and are widely used in flow meters. This paper presents a tooth profile design of an oval gear according to the curvature of the pitch curve. The length of the pitch oval is divided by the number of teeth and the curvature of the divided points is obtained. The tooth profile is designed on the circle of the curvature as if it is the pitch circle of a gear. The teeth of the oval gear have the same module and pressure angle, but the pitch circle of each tooth differs in size. Thus, the teeth on the divided points of the pitch oval are different in shape. This type of oval gear will improve the meshing properties.

A study on the maximum thrust of the Linear Pulse Motor for the head driver (헤드 구동용 Linear Pulse Motor의 최대 추력에 관한 연구)

  • Kim, Jung-Gyo;Jun, Hee-Deuk;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.70-72
    • /
    • 2002
  • LPM that is used for head driver is problem of miniaturization of construction and cost. This can be achieved by most suitable shape decision. and suitable selection of control system. Specially, in LPM that Full step is mm$\sim$um unit. the large change of thrust receives much effect by tooth number per pole. tooth width and slot width about change of the air gap length. Therefore, this paper presents LPM that use for suitable head driver to reduce of the structure and the cost. to generate maximum thrust of LPM, and finds the proportion of the tooth pitch to tooth width and the slot width about change of the air gap length through FEM analysis. Also, applying different tooth width and slot width that is given as analysis result. this paper presented model that thrust is improved.

  • PDF