• 제목/요약/키워드: Tooth reduction

검색결과 321건 처리시간 0.024초

Etched Metal Resin Bonded Retainer에 관한 임상적 연구 (A Clinical Study on the Etched Resin Bonded Retainer for Fixed Bridgework)

  • 양재호
    • 대한치과의사협회지
    • /
    • 제21권5호통권168호
    • /
    • pp.395-402
    • /
    • 1983
  • The purpose of this study was to apply the etched metal ceramometal retainer using a composite resin and acid-etch procedure with minimal tooth reduction of abutments for the replacement of one missing anterior or posterior tooth. Author obtained the following conclusions. 1. conservation of tooth structure and minimal chair time and patient expense were the primary advantages of etched metal retainer. 2. This fixed partial denture permitted good esthetic results. 3. This retainer was successfully applied for the replacement of one missing anterior or posterior tooth. 4. Proper retainer etching ws an important procedure. 5. Etched castings could be applied to periodontal splinting and post orthodontic fixation.

  • PDF

Development of the Sub Gear for the Scissors Gear System for Automobile Engines

  • Nakazawa, Katsuhito;Nagata, Toshihiko;Motooka, Naoki
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.756-757
    • /
    • 2006
  • P/M enables the economical production of components for many kinds of gears. Functionally, the sub gear requires high tooth accuracy and bending fatigue strength. The whole tooth profile was sized after sintering to satisfy the gear tooth accuracy specification. The part was redesigned to reduce machining requirements. The required bending fatigue strength was achieved through appropriate material choice and induction of compressive residual stress by shotpeening after carburizing. The P/M sub gear replaced a forged steel gear, satisfied performance requirements, expanded the use of P/M applications and provided over 30% cost reduction.

  • PDF

Alveolar ridge preservation with a collagen material: a randomized controlled trial

  • Schnutenhaus, Sigmar;Doering, Isabel;Dreyhaupt, Jens;Rudolph, Heike;Luthardt, Ralph G.
    • Journal of Periodontal and Implant Science
    • /
    • 제48권4호
    • /
    • pp.236-250
    • /
    • 2018
  • Purpose: Resorption of the alveolar bone is an unavoidable consequence of tooth extraction when appropriate alveolar ridge preservation (ARP) measures are not taken. The objective of this trial was to test the hypothesis that dimensional changes in the alveolar bone after tooth extraction would be reduced by inserting an equine collagen membrane and a collagen cone to fill and seal the alveolus (as ARP), in comparison to extraction with untreated alveoli. Methods: In this randomized clinical trial, 31 patients were directly treated with the collagen material after extraction of a tooth from the maxilla (the ARP group). Twenty-nine patients served as the control group. After extraction, no further treatment (i.e., no socket preservation measures) was performed in the control group. Changes in the alveolar process immediately after extraction and after an 8 (${\pm}1$)-week healing period were evaluated 3-dimensionally. Blinded analyses were performed after superimposing the data from the digitalized impressions and surfaces generated by cone-beam computed tomography. Results: Both the ARP and control groups showed a reduction of bone in the alveolar area after tooth extraction. However, significantly less bone resorption was detected in the clinically relevant buccal region in the ARP group. The median bone reduction was 1.18 mm in the ARP group and 5.06 mm in the control group (P=0.03). Conclusions: The proposed hypothesis that inserting a combination material comprising a collagen cone and membrane would lead to a difference in alveolar bone preservation can be accepted for the clinically relevant buccal distance. In this area, implantation of the collagen material led to significantly less alveolar bone resorption. German Clinical Trials Register at www.drks.de, DRKS00004769.

의치온성시 발생하는 교합 및 수직고경 변화에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON OCCLUSAL AND VERTICAL CHANGES AFTER DENTURE PROCESSING)

  • 김기성;김창회
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.77-90
    • /
    • 1990
  • The purpose of this study was to compare the amount of the vertical pin opening of $33^{\circ}$ resin and $0^{\circ}$ resin teeth during processing and to determine whether the changes in tooth contacts by using articulation ribbon and T-Scan system follow any identifiable pattern, and to determine if there is any correlation between the changes in tooth contacts and the amount of the vertical pin opening after processing. Through statistical analyses on the data from this study, the following conclusions were obtained. 1. The amounts of the vertical pin opening were 0.78m, 0.87mm for $0^{\circ}$ teeth and $33^{\circ}$ teeth, respectively. But there was no significant difference between them. 2. The total number of contact points recorded by articulating ribbon after processing was decreased to 442.5% of that before processing. 3. The mean values for the number of contact points per tooth recorded by articulating ribbon after processing were 4.3 for the second molar, 3.8 for the first molar, 1.3 for the second premolar, 0.8 for the first premolar. The reduction of contact points per tooth became greater moving in an anterior direction. 4. The correlation between the reduction of contact points and the amount of the pin opening after processing was not significant. 5. The mean values for the numbers of contact points per tooth recorded by T-Scan system after processing were 2.2, 2.5, 1.0, and 0.5 at the second molar, the first molar, the second premolar, and the first premolar, respectively. 6. The correlation between the number of contact points by using articulating ribbon and TScan system after processing was not significant.

  • PDF

박용함속치차장치에서 전위가 베어링하중에 미치는 영향 (The effect of addendum modification on bearing load in marine reduction gears)

  • 민우홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.74-80
    • /
    • 1984
  • In the reduction gears for marine propulsion engine such as turbine or high speed diesel engine, the standard involute double helical gears are generally used. However the addendum modification gear can be used in the reduction gear as it has flexibility for gear design on the tooth strength, scoring and operating noise. In this case, the determination of gear shaft bearing load is difficult by the alternation of operating pressure angle. In this paper, the formulas of bearing load according to the arrangements of the reduction gears are derived and the diagrams of operating pressure angle according to the modification coefficient are presented.

  • PDF

한국 유치 모델에서 유전치 지르코니아 크라운의 형태계측학적 연구 (A Morphometric Study of Primary Anterior Zirconia Crowns in Korean Tooth Models)

  • 박정하;이상호;이난영;지명관
    • 대한소아치과학회지
    • /
    • 제45권1호
    • /
    • pp.41-56
    • /
    • 2018
  • 본 연구의 목적은 한국인의 상악 유중절치와 유측절치와 기성 지르코니아 크라운의 형태 및 크기를 3차원적으로 분석함으로써 가장 유사한 지르코니아 크라운을 선별하고 수복시 임상적 지침을 제시하는 것이다. 이를 위해 300명의 어린이의 건전한 상태의 상악 유중절치, 유측절치를 3차원 스캔하여 평균 형태를 재현하였고, 4개의 제조사(NuSmile $ZR^{(R)}$ Crown, Cheng $Crowns^{(R)}$, Kinder $Krowns^{(R)}$, EZ $Pedo^{(R)}$ Crown)의 지르코니아 크라운을 3차원 스캔하여 형태 및 크기 비교를 위한 좌표점을 측정하여 치아와 크라운 형태의 유사성을 평가하였다. 근원심 길이, 절단연에서 치경부까지의 길이, 치관 형태 비율, 같은 좌표에서 치아와 크라운의 거리, 순면의 곡률반경, 그리고 체적을 비교하여 최종적으로 가장 유사한 지르코니아 크라운을 선별하였다. 분석 결과, 상악 유중절치는 Cheng $Crowns^{(R)}$ 3번, 유측절치는 NuSmile $ZR^{(R)}$ Crown 2번이 가장 유사한 형태를 가졌으며, 이 크라운의 내면을 스캔하여 크라운 수복시 필요한 치아 삭제량을 평가한 결과, 기존의 제조사의 가이드라인으로 제시되어 있는 양보다 전반적으로 더 적은 치아 삭제를 시행하는 것을 제안할 수 있다.

로봇용 정밀 감속기 설계 전문가 시스템 개발 (Development of an Expert System for Precision Reducer Design of Robot)

  • 박대현;남원기;장인훈;오세훈;심귀보
    • 한국지능시스템학회논문지
    • /
    • 제17권1호
    • /
    • pp.19-25
    • /
    • 2007
  • 로봇 시스템에서 사용되는 정밀 감속기 중에 사이클로이드 감속기는 높은 성능을 갖추고 있다. 이러한 사이클로이드 감속기를 설계하는 경우에는 많은 요소들을 고려해야 한다. 우선 기본 개념을 바탕으로 치형의 기하학적 분석이 그려져야만 한다. 그리고 기어의 이에 걸리는 하중과 스트레스, 수정계수를 정확히 계산하여야 한다. 마지막으로는 사이클로이드 치의 설계에 활용하기 위한 컴퓨터 소프트웨어는 기하학과 힙의 방정식을 기초로 발전할 필요가 있다. 이 논문에서 사이클로이드 감속기 설계 전문가 시스템은 비주얼C++를 사용하여 개발되어 진다. 그러므로 가장 중요한 요소는 사용자가 간단한 입력값을 넣음으로써 자동으로 구할 수 있다는 것이다.

잇수차가 적은 내접치차의 다목적 최적 설계 (Multi-objective Optimal Desing of Internal Gear with Small Tooth Difference)

  • 최영석;김성근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.808-812
    • /
    • 1996
  • Reduction gear with internal gear pair need functions such as compact size, high reduction ratios, high transmission efficiency, and low noise. Feasible design region of the internal gear pair with a small tooth difference is extremely limited because the internal gear pair is subject to interference in meshing and cutting. Single-objective optimal design can not simulataneously satisfy the manifold requirements of the internal gear pair and can not determine the economical specification of a pinion cutter. Multi-objective optimal design which include the specification of the pinion cutter in design variables is developed, considering the manufacturing error of an internalgear pair and the re-sharpening of the pinion cutter.

  • PDF

EXPERIMENTAL IDENTIFICATION ON A GEAR WHINE NOISE IN THE AXLE SYSTEM OF A PASSENGER VAN

  • Kim, S.J.;Lee, S.K.
    • International Journal of Automotive Technology
    • /
    • 제8권1호
    • /
    • pp.75-82
    • /
    • 2007
  • This paper presents practical work on the reduction of gear whine noise. In order to identify the source of the gear whine noise, transfer paths are searched and analyzed by operational deflection shape analysis and experimental modal analysis. It was found that gear whine noise has an air-borne noise path instead of structure-borne noise path. The main sources of air-borne noise were the two global modes caused by the resonance of an axle system. These modes created a vibro-acoustic noise problem. Vibro-acoustic noise can be reduced by controlling the vibration of the noise source. The vibration of noise source is controlled by the modification of structure to avoid the resonance or to reduce the excitation force. In the study, the excitation force of the axle system is attenuated by changing the tooth profile of the hypoid gear. The modification of the tooth profile yields a reduction of transmission error, which is correlated to the gear whine noise. Finally, whine noise is reduced by 10 dBA.

침탄치차의 쇼트피닝처리가 크랙진전억제에 미치는 영향 (Effects of Shot Peening on Crack Growth Resistance in Carburized Gears)

  • 류성기;정인성
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3227-3235
    • /
    • 1994
  • This paper deals with an evaluation of the residual stress due to shot peening induced in a carburized gear tooth and its application to the fatigue crack propagation problem. A practical method is proposed on the basis of the assumption that the residual stress is caused by the difference of volume expansion in the case and the core, and the influence of both the reduction of retained austenite and the strain due to shot peening are considered. The evaluated residual stress is close to the measured stress, though the surface stress is rather overestimated. The stress intensity factor is computed by the influence function method, and it is shown that the factor is decreased by the residual stress in shot peened gear tooth. The shot peening is fairly effective to the reduction of fatigue crack growth rate. The crack propagation is simulated and the resistance due to shot peening is quantitatively demonstrated and discussed.