• Title/Summary/Keyword: Tooth displacement

Search Result 200, Processing Time 0.023 seconds

Sintering of the Crankshaft Position Sensor Wheel

  • Park, J.K.;Park, H.S.;Park, J.S.;Song, K.W.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.401-402
    • /
    • 2006
  • All-surface, all-tooth machining and roll forming of cast iron have been used to manufacture the crankshaft position sensor wheel (CPSW). However, these methods pose many problems such as difficult processing, high material cost, and low tooth precision. Thus, we developed a sintered CPSW with an improved detection ability in order to resolve the problems related with the previous methods of manufacturing CPSW by simplifying the process flow and improving tooth precision. The sintering process is introduced in this study. We conducted an experiment to compare the sintered and roll formed products and analyzed the results to evaluate the reliability of the sintering process. Furthermore, we compared and analyzed stress and displacement in the sintered and roll formed products through the "Finite Element Method(FEM)". According to the experimental and FEM results, the sintered product showed satisfactory mechanical properties. It was less expensive to process and lighter and showed better quality than the roll formed product. The results of this study could be applied to design an optimum CPSW using the sintering process.

  • PDF

Tooth Load Sharing and Deformation Overlap of Helical Gear Pairs for the Manual Transmission of Automobile (수동변속기 헬리컬 기어치의 접촉력 평가를 통한 변형간섭 해석)

  • 박수진;유완석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.190-196
    • /
    • 2003
  • The load sharing and teeth deflection of helical gear system are analyzed to investigate the deformation overlap. The deformation overlap, which is calculated by the results of displacement analysis, is suggested as the basis for the tooth profile modification. Helical gear systems are formulated as contact problems, and solved by elastic contact theory and FEM. The developed computer program, which offers gear teeth deflection and deformation overlap, will be of much help to the improved design of manual transmissions for automobiles.

A STRESS ANALYSIS OF FIXED PROSTHESES WITH DENTAL IMPLANT AND NATURAL TOOTH (임플랜트와 자연치를 지대치로 한 고정성 보철물의 응력분석)

  • Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.447-459
    • /
    • 1993
  • A two dimensional finite element model was constructed to analyze the mechanical behavior of four unit fixed partial dentures (FPD) with a 2nd premolar abutment either employing a rigid or nonrigid connector and a 2nd molar abutment(Branemark implant, IMZ implants and natural tooth). Gap elements were used to model the clearance space of the nonrigid connectors and each components of implants. All FPDs with a implant abutment alter the patterns of stress distribution and displacement, but the magnitude of stress in the periodontium was not greater than that of the control. A FPD with rigid connectors induced the smaller stresses in the periodontium than a FPD with a nonrigid connector. A FPD with a Branemark implant exhibited the more desirable mechanical stress states as compared to the IMZ implants with IME or IMC.

  • PDF

The Thrust and Normal Force Analysis of Hybrid Linear Pulse Motor

  • Yoon, Shin-Yong;Baek, Soo-Hyun;Kim, Yong;Kim, Cherl-Jin
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.2
    • /
    • pp.34-39
    • /
    • 2001
  • This paper described the forces analysis of a hybrid linear pulse motor (HLPM) with high accuracy and repeatability. The HLPM is fed from a phase current by microstepping drive. The finite element method (FEM) is employed for calculating the force. The forces between mover(forcer) and stator(platen) have been calculated using the virtual work method. The detent force, rate of tooth width to tooth pitch and magnetic saturation were analyzed to considered the distortion characteristics of static thrust. The thrust to displacement produced a high pulsating force while the normal force is much higher than the thrust force.

Transmission Error Analysis of Helical Gears in Consideration of Shaft and Bearing Deformation (축과 베어링 변형을 고려한 헬리컬 기어의 전달오차 해석)

  • Park, Chan-Il;Cho, Do-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.10
    • /
    • pp.2194-2200
    • /
    • 2002
  • Transmission error is highly related to gear noise. In order to predict the helical gear noise, transmission error analysis is needed. Up to now, the studies for the transmission error were conducted by the modeling of helical gears only. However, since helical gears are supported by the shaft and bearing, transmission error has the effects of the elements. In this study, the procedure to consider the shaft deformation with bearing stiffness for the transmission error analysis is proposed. To do so, the relationship between gear error and shaft deformation is analytically derived. Shaft deformation with bearing stiffness is analyzed by FEM. It is measured in the experimental test rig by the non-contact displacement sensors. Using the tooth error from tooth modification and the shaft deformation, the effects of shaft on the loaded transmission error are investigated.

Missing teeth after maxillofacial trauma: a case report and management protocol

  • Ramaraj, P.N.;Mahabaleshwara, C.H.;Rohit, Singh;Abhijith, George;Vijayalakshmi, G.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.422-427
    • /
    • 2020
  • Management of maxillofacial trauma includes primary care, in which diagnosis and management of dentoalveolar injury play a vital role. Due to the impact sustained during a maxillofacial injury (whether direct or indirect), dentoalveolar injuries can occur, leading to fracture and displacement of teeth and associated alveolar bone into the surrounding soft tissues and associated structures, such as the maxillary sinus, nasal cavity, upper respiratory tract, tracheobronchial tree, or gastrointestinal tract. Undiagnosed displaced teeth may cause complications such as airway obstruction. This paper reports a case of displaced teeth in the nasal cavity and gastrointestinal tract and highlights the management protocol for displaced teeth secondary to maxillofacial trauma.

FINITE ELEMENT ANALYSIS OF THE INFLUENCE OF ESTHETIC POSTS ON INCISORS (심미 포스트가 전치에 미치는 응력과 변위에 관한 삼차원 유한요소법적 분석)

  • Kwon Tae-Hoon;Hwang Jung-Won;Kim Sung-Hun;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.582-595
    • /
    • 2003
  • Statement of problem : Most posts are metallic, but in response to the need for a post that possesses optical properties compatible with an all-ceramic crown. an esthetic post has been developed. Although there have been many studies about the esthetic post materials, 3-dimensional finite element studies about the stress distribution of them are in rare. Purpose : The purpose of this study is to investigate comparatively the distribution of stresses of the restored, endodontically treated maxillary incisors with the esthetic post materials and the displacement on the cement layer on simulated occlusal loading by using a 3-dimensional finite element analysis model. Material and method : Four 3-dimensional finite element models were constructed in a view of a maxillary central incisor, a post, a core, and the supporting tissues to investigate the stresses in various esthetic posts and cores and the displacement on the cement layer (Model 1 ; Cast gold post and core, Model 2 ; Glass fiber post with composite core, Model 3 ; Zirconia post with composite core. Model 4 ; Zirconia post with ceramic core). Force of 300N was applied to the incisal edge and the cingulum (centric stop point) with the angle of 135-degree to the long axis of the tooth. Results : 1. The stresses and displacement on the incisal edge were higher than on the cingulum 2. The stresses in dentin were the highest in Model 2 (Glass fiber post with composite core), and the second was Model 3, the third Model 1, and the lowest Model 4. 3. The stresses in post and core were the highest in Model 4 (Zirconia post with ceramic core), and the second was Model 1, the third Model 3, and the lowest Model 2. 4. The displacement on the cement layer was the highest in Model 2 (Glass fiber post with composite core), and the second was Model 3, the third Model 1, and the lowest Model 4. Conclusion : When a functional maximum bite force was applied, the distribution of stresses or the esthetic post and core materials and the displacement on the cement layer were a little different. It seems that restoring extensively damaged incisors with esthetic post and core materials would be decided according to the remaining tooth structure.

Development of the Hydraulic Gear Pump for an Elevator (엘리베이터용 기어펌프 개발)

  • Jeong, Seok-Hoon
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.117-124
    • /
    • 2011
  • A gear pump is a type of pump that displaces a volume of fluid by physical or mechanical action, or positive displacement pump. Power is applied to one of the gears and transmitted to a second driven gear via meshing teeth. This paper describes the hydraulic gear pump for an elevator. In gear pump, since geometrically special forms of gear tooth, 'Pulsations' is always caused in the delivery pressure and quantity. In other words, it is found that the number of delivery pressure pulsation per each revolution is always equal to that of the gear-teeth of the gear, which is coincident with the pulsation of the ideal delivery quantity. Some experimental results are given to verify the effectiveness of the developed pump.

상악 매복 견치의 교정학적 고찰

  • Seo, Jeong-Hun
    • The Journal of the Korean dental association
    • /
    • v.25 no.1 s.212
    • /
    • pp.59-70
    • /
    • 1987
  • Orthodontists, in evaluating maxillary impactd canines, must take into consideration the etiology of the problem. First, the possible etiologic factors must be eliminated. Thus some cases can be treated with orthodontic treatment alone without surgical trauma following window opening etc. Now, two cases are reported, which were treated without surgical intervention. Sometimes, impacted canine can be included in a plan for tooth removal due to its severe impaction and displacement. In such case, first premolar can be substituted for canine. One case which was treated by substituting maxillary first premolar for maxillary impacted canine is reported.

  • PDF

ERUPTION GUIDANCE FOR TOOTH GERM OF PREMOLAR DISPLACED BY INFRAOCCLUDED UPPER DECIDUOUS MOLAR (저위교합된 상악 유구치에 의해 변위된 소구치 치배의 맹출유도)

  • Jung, Jung-Hwa;Kim, Young-Jin;Kim, Hyun-Jung;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.390-396
    • /
    • 2012
  • Infraocclusion is defined as tooth whose relative occlusal movement was blocked during the period of active eruption due to ankylosis and so on. Then infraoccluded tooth remains under the occlusal plane composed by adjacent structures showing normal eruption patterns. Untreated infraocclusion may cause: prolonged retention of infraoccluded teeth; extrusion of apposed teeth; destruction of periodontal tissues by occlusal force and food packing; increased sensitivity for dental caries; and disturbances on eruption pathway of succedaneous teeth. Therefore, periodic check-ups and proper treatments are required. There are many treatment options on infraoccluded deciduous molars such as periodic observation, conservative method, restoration and space regaining with extraction of the teeth. The choice of treatment may depend on the presence of succedaneous teeth, time of diagnosis and degree of infraocclusion. In this case report, three patients showing displacement of the second premolars due to infraocclusion of upper second primary molars, were treated by means of space regaining with removable orthodontic appliances and extraction of ankylosed primary molars. All malpositioned permanent premolars in the 3 cases showed ordinary eruption pathways after treatment.