• Title/Summary/Keyword: Tooth Structure

Search Result 317, Processing Time 0.025 seconds

Implications of specific gene expression patterns in enamel knot in tooth development

  • Kim, Tae-Young;Neupane, Sanjiv;Aryal, Yam Prasad;Lee, Eui-Seon;Kim, Ji-Youn;Suh, Jo-Young;Lee, Youngkyun;Sohn, Wern-Joo;An, Seo-Young;Ha, Jung-Hong;An, Chang-Hyeon;Kim, Jae-Young
    • International Journal of Oral Biology
    • /
    • v.45 no.1
    • /
    • pp.25-31
    • /
    • 2020
  • Enamel knot (EK)-a signaling center-refers to a transient morphological structure comprising epithelial tissue. EK is believed to regulate tooth development in early organogenesis without its own cellular alterations, including proliferation and differentiation. EKs show a very simple but conserved structure and share functions with teeth of recently evolved vertebrates, suggesting conserved signaling in certain organs, such as functional teeth, through the course of evolution. In this study, we examined the expression patterns of key EK-specific genes including Dusp26, Fat4, Meis2, Sln, and Zpld1 during mice embryogenesis. Expression patterns of these genes may reveal putative differentiation mechanisms underlying tooth morphogenesis.

Application of AutoLISP to Electric Motor design (전기 모터설계에의 AutoLISP 응용)

  • Oh, Chul-Soo;Kong, Jeong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.126-129
    • /
    • 1991
  • The effect of each tooth for optimal design of Hybrid permanent magnet step motor is presented on this paper. For this consideration, Hybrid permanent magnet step motor was designed in the first consideration tooth structure on the stator and the rotor and poles structure, as number of teeth on the stator and the rotor and slot depth and pitch of teeth, simulated by AutoLISP. During actual rotating, a chracteristic of Hybrid permanent magnet step motor which designed by AutoLISP program is considered. A chracteristic of Hybrid permanent magnet step motor is considered in change each variable, also. As a result, it was found that characteristic of Hybrid permanent magnet step motor changed in accordance with tooth structure and number of teeth and optimal design is possible by AutoLISP.

  • PDF

Development of the injection mold structure for internal gears (내측기어 성형용 사출성형 금형구조의 개발)

  • Kwon, Y.S.;Jeong, Y.D.
    • Journal of Power System Engineering
    • /
    • v.12 no.6
    • /
    • pp.78-82
    • /
    • 2008
  • Plastic gears are more and more widely used in many industrial machine elements. Plastic gear has higher properties such as light weight, wear resistance, and vibration absorbing ability than metallic gears. But, in case of using an inaccurate plastic gear, its tooth breakage happen and fatigue life is shortened due to increase of applying load and temperature rising on the tooth flank. Inaccuracy of plastic gears such as pitch circle roundness and tooth profile generates vibration and noise. In this study, an internal plastic gears which is molded by a new injection mold structure are developed. The new mold structure is called the HR3P(hot runner type 3plate mold) that has an improved runner system in order to have good filling balance. As a result from this study, an internal gear with very accurate roundness was developed by using design of experiment.

  • PDF

Effects of HA and TiN Coating on the Electrochemical Characteristics of Ti-6Al-4 V Alloys for Bone Plates

  • Oh, Jae-Wook;Choe, Han-Cheol;Ko, Yeong-Mu
    • Journal of Surface Science and Engineering
    • /
    • v.37 no.5
    • /
    • pp.249-252
    • /
    • 2004
  • Effects of HA and TiN coating on the electrochemical characteristics of Ti-6AI-4V alloys for bone plates were investigated using various test methods. Ti-6AI-4V alloys were fabricated by using a vacuum induction furnace and bone plates were made by laser cutting and polishing. HA was made of extracted tooth sintered and then tooth ash was used as HA coating target. The TiN and HA film coating on the surface were carried on using electron-beam physical vapor deposition (EB-PVD) method. The corrosion behaviors of the samples were examined through potentiodynamic method in 0.9% NaCI solutions at $36.5\pm$$1^{\circ}C$ and corrosion surface was observed using SEM and XPS. The surface roughness of TiN coated bone plates was lower than that of tooth ash coated plates. The structure of TiN coated layer showed the columnar structure and tooth ash coated layer showed equiaxed and anisotrophic structure. The corrosion potential of the TiN coated specimen is comparatively high. The active current density of TiN and tooth ash coated alloy showed the range of about $1.0xl0^{-5}$ $A\textrm{cm}^2$, whereas that of the non-coated alloy was$ 1.0xl0^{-4}$ $A\textrm{cm}^2$. The active current densities of HA and TiN coated bone plates were smaller than that of non-coated bone plates in 0.9% NaCl solution. The pitting potential of TiN and HA coated alloy is more drastically increased than that of the non-coated alloy. The pit number and pit size of TiN and HA coated alloy decreased in compared with those of non-coated alloy. For the coated samples, corrosion resistance increased in the order of TiN coated, tooth ash coated, and non-coated alloy.

Types of Mentum Deformity for Chironomus riparius Exposure to DEHP (DEHP에 노출된 Chironomus riparius의 하순기절에 나타난 기형 유형들)

  • Kwak, Inn-Sil;Jeong, Gyeong-Suk
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Induction of morphological deformities in Chironomus riparius larvae was assessed after exposure to 0.3, 1, 10 and 30 ${\mu}g\;L^{-1}$ potential endocrine disruption chemicals, Diethylhexyl phtalate (DEHP). We observed and subdivide types of mentum deformities and counted the incidence of mentum deformities. The mortality was not increased according to concentrations of DEHP, while was depend on the exposed days. The incidence of mentum deformities for MLT (median lateral teeth), LT (lateral teeth), and MIX (MLT+LT) of the mentum morphological structure showed MLT (2.8$\sim$11.4%)>LT (2.8$\sim$2.9%)>MIX (2.8$\sim$3.0%). The type of mentum deformities on C. riparius was classified six groups following exposure to DEHP. The incidence rate was occupied following to tooth addition (4.3%), tooth split (2.8%), tooth deletion (2.4%), tooth fusion (1.4%), $K"{o}hn$ gap (0.5%) and abnormal shape (0.5%). Especially tooth split and tooth fusion were observed in DEHP treated conditions.

A Preview of the Valid Natural Tooth Implantation(NTI) Related with Periodontal Diseases

  • Chang, Sang-Kohn
    • Proceedings of the KACD Conference
    • /
    • 2002.11a
    • /
    • pp.721-721
    • /
    • 2002
  • For about half a century. dental implants made of titanium have developed as a method of restoration for the tooth loss. In these days. the titanium implants seem to be considered as the alternative for the conventional prosthodontics. But its hard to say that the titanium implants are superior to the treatments that preserve the natural tooth. As this is a general opinion among dentists. the implant will not be able to be the alternative for all the prosthetic treatments. Clinically, there are many causes for extracting tooth. The severe destruction of the tooth structure or periodontal diseases leads to inevitable tooth extraction. When the complete cure is doubtful because of narrow intraoral visibility and improper accessibility in approaching to the tooth and periodontal lesion, we. clinicians often inevitably extract tooth. Passive treatments like conventional restoration, curettage or surgical flap cant be the perfect treatments for the tooth that has subgingival root caries or severe periodontal diseases involved furcation. Many clinicians might have been forced to pull out the relatively healthy tooth by the difficulties of approaching to the lesions and poor prognosis. Though the intentional tooth replantation is performed sometimes. as it doesnt have enough scientific foundation. it has not been considered as a popular treatment method yet. I have been felt keenly the necessity of positive tooth preservation, so I have been attempting the treatment that has new concept. calling Natural Tooth Implantation (NTI) clinically. NTI differs from the tooth replantation in the goal for the treatment and biological healing process. Now. I confirm that NT! is a very positive and valid method of tooth preservation. Like you can get from the name. NTI is the dental implant procedure using natural teeth and similar to the healing process of the titanium implants in many aspects. I have been using biocompatible composite resin. DRM. with NTI and got affirmative clinical results from that. So I would like to introduce.roduce.

  • PDF

A CASE REPORT ON PRIMARY INCISOR TREATMENT USING OPEN-FACE STAINLESS STEEL CROWN (Open-face Stainless Steel Crown을 이용한 유전치의 치료에 대한 증례보고)

  • Kim, Jong-Min;Choi, Hyung-Jun;Lee, Jae-Ho;Choi, Byung-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.781-787
    • /
    • 1997
  • In spite of the improvements of the techniques in the field of preventive dentistry, many children still present with extensive destruction of primary anterior teeth. Not only the practioner must consider the pulp state of the primary incisor, but also restore the form, function and esthetics of the tooth. Restorative treatment of primary incisor tooth requires durability, retention and esthetics. Stainless steel crowns used in restoring primary anterior teeth is retentive and durable in comparison with the composite resin, celluloid crown. But they are not esthetic. To enhance the esthetics of the anterior stainless steel crown without reducing its superior retention, an open-face stainless steel crown has been suggested. Several authors have suggested cutting away the labial portion of the stainless steel crown and placing the composite resin in that area. By following this technique, the practioner can prepare a retentive, durable, and esthetic restoration for primary teeth which have suffered from extensive loss of teeth structure. In addition, the single missing primary anterior teeth can be successfully restored by soldering the stainless steel crown together. Open-face stainless steel crown is indicated in the areas of large interproximal lesions involving incisal edge, crown fracture with pulp exposure and congenital malformation of the teeth. By this technique, the practioner can restore primary anterior teeth successfully regardless of the amount of remaining tooth structure, bruxism habit and presence of attrition. In this case, rampant caries with extensive loss of tooth structure and single missing of primary anterior tooth hart been successfully treated with open-face stainless steel crown.

  • PDF

A study on the maximum thrust of the Linear Pulse Motor for the head driver (헤드 구동용 Linear Pulse Motor의 최대 추력에 관한 연구)

  • Kim, Jung-Gyo;Jun, Hee-Deuk;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.70-72
    • /
    • 2002
  • LPM that is used for head driver is problem of miniaturization of construction and cost. This can be achieved by most suitable shape decision. and suitable selection of control system. Specially, in LPM that Full step is mm$\sim$um unit. the large change of thrust receives much effect by tooth number per pole. tooth width and slot width about change of the air gap length. Therefore, this paper presents LPM that use for suitable head driver to reduce of the structure and the cost. to generate maximum thrust of LPM, and finds the proportion of the tooth pitch to tooth width and the slot width about change of the air gap length through FEM analysis. Also, applying different tooth width and slot width that is given as analysis result. this paper presented model that thrust is improved.

  • PDF

Surgical management with intentional replantation on a tooth with palato-radicular groove

  • Forero-Lopez, Jorge;Gamboa-Martinez, Luis;Pico-Porras, Laura;Nino-Barrera, Javier Laureano
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.166-171
    • /
    • 2015
  • A palato-radicular groove (PRG) is a developmental anomaly primarily found in the maxillary lateral incisors. It is a potential communication path between the root canal and the periodontium that decreases the survival prognosis of the affected tooth, therefore compromising the stability of the dental structure in the oral cavity. The aim of this case report is to present an original technique where a PRG was treated by means of intracanal disinfection, PRG sealing with glass ionomer, replantation with intentional horizontal 180 degree rotation of the tooth, and an aesthetic veneer placed to provide adequate tooth morphology. The clinical and biological benefits of this novel technique are presented and discussed.

Stator Shape Optimization for Electrical Motor Torque Density Improvement

  • Kim, Hae-Joong;Kim, Youn Hwan;Moon, Jae-Won
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.570-576
    • /
    • 2016
  • The shape optimization of the stator and the rotor is important for electrical motor design. Among many motor design parameters, the stator tooth and yoke width are a few of the determinants of noload back-EMF and load torque. In this study, we proposed an equivalent magnetic circuit of motor stator for efficient stator tooth and yoke width shape optimization. Using the proposed equivalent magnetic circuit, we found the optimal tooth and yoke width for minimal magnetic resistance. To verify if load torque is truly maximized for the optimal tooth and yoke width indicated by the proposed method, we performed finite element analysis (FEA) to calculate load torque for different tooth and yoke widths. From the study, we confirmed reliability and usability of the proposed equivalent magnetic circuit.